Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CVR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Conservation Voltage Reduction (CVR) via Two-Timescale Control in Unbalanced Power Distribution Systems

Voltage control devices are employed in power distribution systems to reduce the power consumption by operating the system closer to the lower acceptable voltage limits; this technique is called conservation voltage reduction (CVR). The different modes of operation for system’s legacy devices (with binary control) and new devices (e.g. smart inverters with continuous control) coupled with variable photovoltaic (PV) generation results in voltage fluctuations which makes it challenging to achieve CVR objective. This paper presents a two-timescale control of feeder’s voltage control devices to achieve CVR that includes (1)a centralized controller operating in a slower time-scale to coordinate voltage control devices across the feeder and (2) local controllers operating in a faster timescale to mitigate voltage fluctuations due to PV variability. The centralized controller utilizes a three-phase optimal power flow model to obtain the decision variables for both legacy devices and smart inverters. The local controllers operate smart inverters to minimize voltage fluctuations and restore nodal voltages to their reference values by adjusting the reactive power support. The proposed approach is validated using the IEEE-123 bus (medium-size) and R3-12.47-2 (large-size) feeders. It is demonstrated that the proposed approach is effective in achieving the CVR objective for unbalanced distribution systems.

optimal control, distributed generation, fluctuati↗

An iterative bidirectional gradient boosting approach for CVR baseline estimation

Here this paper presents a novel Iterative Bidirectional Gradient Boosting Model (IBi-GBM) for estimating the baseline of Conservation Voltage Reduction (CVR) programs. In contrast to many existing methods, we treat CVR baseline estimation as a missing data retrieval problem. The approach involves dividing the load and its corresponding temperature profiles into three periods: pre-CVR, CVR, and post-CVR. To restore the missing load profile during the CVR period, the method employs a three-step process. First, a forward-pass GBM is executed using data from the pre-CVR period as inputs. Subsequently, a backward-pass GBM is applied using data from the post-CVR period. The two restored load profiles are reconciled, considering pre-calculated weights derived from forecasting accuracy, and only the leftmost and rightmost points are retained. The newly restored points are then included as inputs for the subsequent iteration. This iterative procedure continues until the original load data in the CVR period is fully restored. We develop IBi-GBM using actual smart meter and Supervisory Control and Data Acquisition (SCADA) data. Our results demonstrate that IBi-GBM exhibits robust performance across various data resolutions and in different seasons and outperforms existing methods by achieving a 1-2% reduction in normalized Root Mean Square Error (nRMSE).

42 ENGINEERING↗

An Iterative Bidirectional Gradient Boosting Algorithm for CVR Baseline Estimation

This paper presents a novel iterative, bidirectional, gradient boosting (bidirectional-GB) algorithm for estimating the baseline of the Conservation Voltage Reduction (CVR) program. We define the CVR baseline as the load profile during the CVR period if the substation voltage is not lowered. The proposed algorithm consists of two key steps: selection of similar days and iterative bidirectional-GB training. In the first step, preand post-event temperature profiles of the targeted CVR day are used to select similar days from historical non-CVR days. In the second step, the pre-event and post-event similar days are used to train two GBMs iteratively: a forward-GBM and a backwardGBM. After each iteration, the two generated CVR baselines are reconciled and only the first and the last points on the reconciled baseline are kept. The iteration repeats until all CVR baseline points are generated. We tested two gradient boosting methods (i.e., GBM and LighGBM) with two data resolutions (i.e., 15and 30-minute). The results demonstrate that both the accuracy and performance of the algorithm are satisfactory.

Lee, Han Pyo↗

Evaluation of Conservation Voltage Reduction (CVR) on a National Level

Conservation Voltage Reduction (CVR) is a reduction of energy consumption resulting from a reduction of feeder voltage. While there have been numerous CVR systems deployed in North America there has been little substantive analytic analysis of the effect; the majority of the published results are based on empirical field measurements. Since these results are based on empirical measurements it is difficult to extrapolate how this technology will behave on the various types of distribution feeders found throughout the nation. This report has utilized the Taxonomy of Prototypical feeder developed under the Modern Grid Initiative (MGI), now the Modern Grid Strategy (MGS), in order to estimate the benefits of CVR on multiple distribution feeder types. This information will then be used to determine an estimate of the national benefits of a wide scale deployment of CVR.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordinated Use of Smart Inverters with Legacy Voltage Regulating Devices in Distribution Systems with High Distributed PV Penetration — Increase CVR Energy Savings

This paper studies the coordinated use of smart inverters with legacy voltage regulating devices to help increase the energy savings from conservation voltage reduction (CVR) in distribution systems with high photovoltaic penetration. Two voltage optimization algorithms are developed to evaluate the CVR benefit by considering two types of smart inverter functions: aggregated reactive power control and autonomous volt/VAR control. In each algorithm, smart inverters are coordinately controlled with the operation of legacy voltage regulating devices including load tap changers and capacitor banks. Both algorithms are tested on representative utility distribution system models. In conclusion, simulation results demonstrate that the proposed algorithms can achieve around 1.8-3.6% energy savings when only using legacy voltage regulating devices and an additional 0.3-0.9% when adding smart inverters.

14 SOLAR ENERGY↗

Smart Grid-Enabled CVR: An Advanced Application for Distribution Management Systems

A multilevel, multitasking smart grid-enabled conservation of voltage reduction (CVR) control and optimization methodology is proposed for advanced distribution management system (ADMS) platforms. The first level deals with the centralized optimization of volt/VAR optimization (VVO) devices; the second-level is for voltage control in the local domain or decentralized control; and the third level assesses the energy savings and CVR factor.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effects of Distributed Energy Resources on Conservation Voltage Reduction (CVR)

Conservation Voltage Reduction (CVR) is one of the cheapest technologies which can be intelligently leveraged to provide considerable energy savings. The addition of renewables in the form of distributed resources can affect the entire power system, but more importantly, affects the traditional substation control schemes at the distribution level. This paper looks at the effect on energy consumption, peak load reduction, and voltage profile changes due to the addition of distributed generation in a distribution feeder using combinations of volt var control. An IEEE 13-node system is used to simulate the various cases. Energy savings and peak load reduction for different simulation scenarios are compared.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Event-Driven Predictive Approach for Real-Time Volt/VAR control with CVR in solar PV rich Active Distribution Network

The focus of this paper is on analyzing the impact of conservation voltage reduction in the presence of active devices such as solar photovoltaic (PV) and developing controls that leverage these distributed energy resources. An event-driven predictive approach for real-time volt/volt-ampere reactive (VAR) optimization, along with local two-level adaptive volt/VAR droop-based control algorithm for advanced distribution management systems, is introduced. The methodology covers aggregated and autonomous controls under different timescale operations, including the impact and effect of unpredicted events such as cloud transients on PV power production. In addition, the control schemes include the uncertainties in PV power generation and load power demand. The proposed methodology is validated in a real-time framework using the real-time digital simulator platform through co-simulation with models based on Python and OpenDSS (Open Distribution System Simulator). The developed methodology is tested on the modified IEEE 123-feeder test system. The results reveal that the proposed methodology works well in the presence of high penetrations of PV power, produces significant energy savings, and mitigates over-/undervoltage problems.

14 SOLAR ENERGY↗

Photovoltaic Impact Assessment of Smart Inverter Volt-VAR Control on Distribution System Conservation Voltage Reduction and Power Quality

This report presents an impact assessment study of distributed photovoltaic (PV) with smart inverter Volt-VAR control on conservation voltage reduction (CVR) energy savings and distribution system power quality. CVR is a methodology of flattening and lowering a distribution system voltage profile in order to conserve energy. Traditional CVR relies on operating utility voltage regulators and switched capacitors. However, with the increased penetration of distributed PV systems, smart inverters provide the new opportunity to control local voltage and power factor by regulating the reactive power output, leading to a potential increase in CVR energy savings. This report proposes a methodology to implement CVR scheme by operating voltage regulators, capacitors, and autonomous smart inverter Volt-VAR control in order to achieve increased CVR benefit. Power quality is an important consideration when operating a distribution system, especially when implementing CVR. It is easy to measure the individual components that make up power quality, but a comprehensive method to incorporate all of these values into a single score has yet to be undertaken. As a result, this report proposes a power quality scoring mechanism to measure the relative power quality of distribution systems using a single number, which is aptly named the 'power quality score' (PQS). Both the CVR and PQS methodologies were applied to two distribution system models, one obtained from the Hawaiian Electric Company (HECO) and another obtained from Pacific Gas and Electric (PG&E). These two models were converted to the OpenDSS platform using previous model conversion tools that were developed by NREL. Multiple scenarios including various PV penetration levels and smart inverter densities were simulated to analyze the impact of smart inverter Volt-VAR support on CVR energy savings and feeder power quality. In order to analyze the CVR benefit and PQS, an annual simulation was conducted for each scenario.

14 SOLAR ENERGY↗

Analysis of Conservation Voltage Reduction under Inverter-Based VAR-Support [Slides]

Conservation voltage reduction (CVR) is a common technique used by utilities to strategically reduce demand during peak periods. As penetration levels of distributed generation (DG) continue to rise and advanced inverter capabilities become more common, it is unclear how the effectiveness of CVR will be impacted and how CVR interacts with advanced inverter functions. In this work, we investigated the mutual impacts of CVR and DG from photovoltaic (PV) systems (with and without autonomous Volt-VAR enabled). The analysis was conducted on an actual utility dataset, including a feeder model, measurement data from smart meters and intelligent reclosers, and metadata for more than 30 CVR events triggered by the utility over the year. The installed capacity of the modeled PV systems represented 66% of peak load, but reached instantaneous penetrations reached up to 2.5x the load consumption over the year. While the objectives of CVR and autonomous Volt-VAR are opposed to one another, this study found that their interactions were mostly inconsequential since the CVR events occurred when total PV output was low.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A physics study for negative void reactivity in compact supercritical CO{sub 2}-cooled fast reactor

A compact S-CO{sub 2}-cooled fast reactor which has negative Coolant Void Reactivity (CVR) has been investigated. A negative CVR is important for the gas cooled fast reactor as an inherent safety mechanism to prevent the sudden positive reactivity insertion when the loss of coolant accident happens. An alternative solution to reduce the CVR is investigated in this study by using O-17 instead of O-16 in UO{sub 2} fuel. By using O-17 in the fuel, it is found that the CVR can even be negative. Impacts of the radial reflector on the CVR are also evaluated for the small SCO{sub 2} cooled fast reactor in this study. We have considered a pure lead (Pb) reflector and a lead magnesium eutectic (LME) reflector as alternative radial reflectors of the S-CO 2-cooled fast reactor. It has been shown that, with the LME radial reflector, the CVR can be negative, while the pure lead reflector provides a slightly positive CVR. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices: Preprint

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Evaluating Conservation Voltage Reduction: An Application of GridLAB-D: an Open Source Software Package

Voltage Reduction (CVR) is the reduction of energy consumption resulting from a reduction of the service voltage. While there have been numerous CVR deployments in North America, there has been little substantive analytic analysis of the effect; the majority of the published results are based on empirical field measurements. Due to the lack of analytic study, it is difficult to determine the impacts of CVR outside of sites that have conducted demonstration projects. This panel paper will examine a framework for the analysis of CVR using the open source software package GridLAB-D. An open source simulation environment is used to highlight the effectiveness of open source software programs and their ability to be used for evaluating multi-disciplinary smart grid technologies.

Schneider, Kevin P.↗

Maximizing the Benefits of Volt/VAR Optimization in the Presence of Community Energy Storage

This paper reports on the need for coordinating smart grid volt/volt-ampere reactive (VAR) control (VVC) and community energy storage (CES) to maximize the benefits of both approaches. It addresses a key application of volt/VAR optimization (VVO): the conservation of voltage reduction (CVR). The lack of coordination among network controls, such as VVO, and asset controls at the community battery storage system can lead to detrimental effects on grid operation. A smart grid-enabled VVC uses the VVO to perform the CVR operation. VVO can perform numerous tasks for advanced distribution management systems with coordination of the system operator. To achieve the optimal VVC solution, we use a particle swarm optimization driven VVO method. The test system has been simulated for two scenarios-during light loading and high loading condition-with and without the CES system. In both scenarios, the operation of CVR and CES have been performed considering different case studies. The outcomes of the simulated results demonstrate that significant improvement in peak load-demand reduction is achieved by the proposed VVC and CES system with reduced system losses.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stochastic DG Placement for Conservation Voltage Reduction Based on Multiple Replications Procedure

Conservation voltage reduction (CVR) and distributed-generation (DG) integration are popular strategies implemented by utilities to improve energy efficiency. This paper investigates the interactions between CVR and DG placement to minimize load consumption in distribution networks, while keeping the lowest voltage level within the predefined range. The optimal placement of DG units is formulated as a stochastic optimization problem considering the uncertainty of DG outputs and load consumptions. A sample average approximation algorithm-based technique is developed to solve the formulated problem effectively. A multiple replications procedure is developed to test the stability of the solution and calculate the confidence interval of the gap between the candidate solution and optimal solution. The proposed method has been applied to the IEEE 37-bus distribution test system with different scenarios. The numerical results indicate that the implementations of CVR and DG, if combined, can achieve significant energy savings.

24 POWER TRANSMISSION AND DISTRIBUTION↗