Ultrastable low-noise current amplifier: A novel device for measuring small electric currents with high accuracy

An ultrastable low-noise current amplifier (ULCA) is presented. The ULCA is a non-cryogenic instrument based on specially designed operational amplifiers and resistor networks. It involves two stages, the first providing a 1000-fold current gain and the second performing a current-to-voltage conversion via an internal 1 MΩ reference resistor or, optionally, an external standard resistor. The ULCA’s transfer coefficient is highly stable versus time, temperature, and current amplitude within the full dynamic range of ±5 nA. The low noise level of 2.4 fA/√Hz helps to keep averaging times short at small input currents. A cryogenic current comparator is used to calibrate both input current gain and output transresistance, providing traceability to the quantum Hall effect. Within one week after calibration, the uncertainty contribution from short-term fluctuations and drift of the transresistance is about 0.1 parts per million (ppm). The long-term drift is typically 5 ppm/yr. A high-accuracy variant is available that shows improved stability of the input gain at the expense of a higher noise level of 7.5 fA/√Hz. The ULCA also allows the traceable generation of small electric currents or the calibration of high-ohmic resistors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Expanding the bandwidth of the ultra-low current amplifier using an artificial negative capacitor

The bandwidth and low noise characteristics are often contradictory in ultra-low current amplifier, because an inevitable parasitic capacitance is paralleled with the high value feedback resistor. In order to expand the amplifier’s bandwidth, a novel approach was proposed by introducing an artificial negative capacitor to cancel the parasitic capacitance. The theory of the negative capacitance and the performance of the improved amplifier circuit with the negative capacitor are presented in this manuscript. The test was conducted by modifying an ultra-low current amplifier with a trans-impedance gain of 50 GΩ. The results show that the maximum bandwidth was expanded from 18.7 Hz to 3.3 kHz with more than 150 times of increase when the parasitic capacitance (∼0.17 pF) was cancelled. Meanwhile, the rise time decreased from 18.7 ms to 0.26 ms with no overshot. Any desired bandwidth or rise time within these ranges can be obtained by adjusting the ratio of cancellation of the parasitic and negative capacitance. This approach is especially suitable for the demand of rapid response to weak current, such as transient ion-beam detector, mass spectrometry analysis, and fast scanning microscope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noise Erasure in Quantum-Limited Current Amplifiers

Superconducting quantum interference devices (SQUIDs) are extraordinarily sensitive to magnetic flux and thus make excellent current amplifiers for cryogenic applications. One such application of high interest to Sandia is the set-up and state read-out of quantum dot based qubits, where a qubit state is read out from a short current pulse (microseconds to milliseconds long) of approximately 100 pA, a signal that is easily corrupted by noise in the environment. A Parametric SQUID Amplifier can be high bandwidth (in the GHz range), low power dissipation (less than 1pW), and can be easily incorporated into multi-qubit systems. In this SAIL LDRD, we will characterize the noise performance of the parametric amplifier front end -- the SQUID -- in an architecture specific to current readout for spin qubits. Noise is a key metric in amplification, and identifying noise sources will allow us to optimize the system to reduce its effects, resulting in higher fidelity readout. This effort represents a critical step in creating the building blocks of a high speed, low power, parametric SQUID current amplifier that will be needed in the near term as quantum systems with many qubits begin to come on line in the next few years.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cost-Effective Three-Phase Current Amplifier Interface for Real-time Simulator with Relays in-the-Loop

This paper presents a prototype of a simple and cost-effective design using a high-power monolithic power amplifier that allows the relay in-the-loop connectivity for protection and control applications using a real-time simulator. This low-cost amplifier interface increases the number of protective relays in-the-loop connected with the real-time simulator, expanding the scalability of protection devices that could be tested. The amplifier control design was developed in abc coordinates and utilizes integral and proportional-resonant controllers to provide a good tracking of both the fundamental component as the dc component that might be present during fault conditions. To validate the prototype, the current signals and tripping time of a relay interfaced with the current amplifier were compared against a reference relay connected to the low-voltage interface. Both protective relays were set with a U3 Very Inverse time overcurrent curve. The experimental results exhibited similar behaviors for the breaker currents, validating the amplifier interface prototype.

Ferrari Maglia, Max↗

Increased Speed: 3D Silicon Sensors. Fast Current Amplifiers

The authors describe techniques to make fast, sub-nanosecond time resolution solid-state detector systems using sensors with 3D electrodes, current amplifiers, constant-fraction comparators or fast wave-form recorders, and some of the next steps to reach still faster results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Kinetic Inductance Ammeter with Coplanar Waveguide Input Structure for Magnetic Flux Focusing

We propose a multiplexible kinetic inductance ammeter, which uses a high-quality-factor, superconducting, lumped-element, kinetic inductance resonator as a current sensor, a short, superconducting coplanar waveguide (CPW) for current input, and a CPW transmission line for the sensor readout. The resonator consists of an interdigitated capacitor and a superconducting loop that inductively couples to the input CPW. Current running through the central line of the input CPW generates magnetic fields which are focused into the gaps of the input CPW. These magnetic fields can be measured collectively as the magnetic flux through the superconducting loop. The kinetic inductance of the superconducting loop depends on the screening current for the magnetic flux, so the input current is converted to a change in the frequency of the resonator. We analyze the response and noise of a kinetic inductance ammeter with a high-resistivity NbN loop.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Single-Event Effect Testing of the Linear Technology LTC6103HMS8#PBF Current Sense Amplifier

The LTC6103HMS8#PBF (henceforth abbreviated as LTC6103) current sense amplifier from Linear Technology was tested for both destructive and non-destructive single-event effects (SEE) using the heavy-ion cyclotron accelerator beam at Lawrence Berkeley National Laboratory (LBNL) Berkeley Accelerator Effects (BASE) facility. During testing, the input voltages and output currents were monitored to detect single event latch-up (SEL) and single-event transients (SETs).

single-event effects (SEE)↗

Lowering Ammeter Input Impedance

Feedback circuit operates in conjunction with sensitive microammeter or other current-measuring instrument to reduce input impedance of composite circuit. In contrast with older current-amplifier circuits, current much less subject to drift and noise, calibration not necessary, and values of components not critical.

Siegel, C. M.↗

Secondary electron yields of solar system ices

The secondary electron yields of H2O, CO2, NH3, and CH3OH ices have been measured as a function of electron beam energy in the 2- to 30-keV energy range. The ices were produced on a liquid-nitrogen-cooled cold finger and transferred under vacuum to a SEM where the yield measurements were made. The imaging capabilities of the SEM provide a means of correlating the yield measurements with the morphology of the ices and are also used to monitor charging effects. The yields were determined by measuring the amplified current from a secondary electron detector and calibrating this current signal with the amplified current signal from samples of metals with known secondary electron yields. Each of the measured yields is found to decrease with an increase in energy in the 2- to 30-keV range. Estimates are given for the maximum secondary electron yield Y(max) of each ice and the energy at which this maximum yield occurs. Implications for the charging of solar system ice grains are discussed.

Suszcynsky, David M.↗

Noise Evaluation of Various High-gain, Very-low-noise Current Sense Amplifier Circuits

We report an evaluation of three different electronic topologies for a high-gain, very-low-noise current sense amplifier (CSA) for use in remote sensing applications. The circuits in question were built from commercially available parts and were evaluated for their performance in an interface to a photodetector used in NASA’s Lunar Flashlight infrared spectrometer spacecraft. Through constraints on the test environment, we were able to reduce the impact of systematic noise sources by making them common mode to the measurement. The parts compared were based on the ADA4530-1, the LTC6240, and the LSK389A. We determined which of the three different versions of the CSA had superior noise performance for selection for use on the instrument. Two tests and simulations of each board compare and contrast functionality and performance, both qualitatively and quantitatively, and based on those results, we show that the ADA4350-1 out-performed the opposing components.

Foor, David↗

Nonuniform Ionic and Electronic Transport of Ceramic and Polymer/Ceramic Hybrid Electrolyte by Nanometer-Scale Operando Imaging for Solid-State Battery

Replacing the liquid electrolyte in lithium batteries with solid-state ion conductor is promising for next-generation energy storage that is safe and has high energy density. In this work, nanometer-resolution ionic and electronic transport imaging of Li 3 PS 4 (LPS), a solid-state electrolyte (SSE), is reported. This nm resolution is achieved by using a logarithm-scale current amplifier that enhances the current sensitivity to the fA range. Large fluctuations of ion current—one to two orders of magnitude on the LPS and on the LPS region of a polymer/LPS bulk hybrid SSE—that must be mitigated to eliminate Li dendrite formation and growth, are found. This ion current fluctuation is understood in terms of highly anisotropic transport kinetic barriers along the different crystalline axes due to different grain orientations in the polycrystalline and glass ceramic materials. The results on the bulk hybrid SSE show a sharp transition of ionic and electronic transport at the LPS/polymer boundary and decreases in average ionic current with decreasing polyimine particle size and with extensive cycling. The results elucidate the mechanism of polyimine extension into interparticles to prevent Li dendrite growth. This work opens up novel characterization of charge transport, which relates to Li plating and stripping for solid-state-batteries.

Li3PS4↗