In-situ relative calibration of Bragg crystals with Monte Carlo line ratio analysis
X-ray line emission spectra can thoroughly characterize hot plasmas, especially when line shapes and ratios convey distinct aspects of plasma conditions. However, the high spectral resolution required for observing line shapes is often at odds with the large bandwidth required to observe many line ratios across a wide spectral range. One strategy to obtain high spectral resolution over a wide bandwidth is to use multiple crystals with calibrated reflectivity so that line intensities across different crystals can be compared. Here, we explore the use of a low-resolution, wide-bandwidth mica survey spectrometer to infer relative reflectivity of two high-resolution, narrow-bandwidth quartz crystals. Finally, a Monte Carlo error analysis determines comparable x-ray line ratios measured from both spectrometers, resulting in an in situ calibration factor and associated uncertainty for the relative reflectivity of the high-resolution crystals.
Modeling Ti–6Al–4V using crystal plasticity, calibrated with multi-scale experiments, to understand the effect of the orientation and morphology of the α and β phases on time dependent cyclic loading
Classically, crystal plasticity modeling has used a range of constitutive equations, in which the incorporation of additional physics-based relationships typically results in additional model parameters. These additional parameters need to be reliably calibrated, which often necessitates the use of a range of experimental data acquired at multiple length scales. In this work, a crystal plasticity based finite element (CPFE) model for a dual-phase Titanium alloy, Ti–6Al–4V, is developed. The α and β phases of the microstructure are explicitly modeled. The model is calibrated using a systematic optimization routine and experimental data that consist of macroscopic stress-strain curves coupled with lattice strains on different crystallographic planes for the two phases. These experimental data were obtained from in situ high energy X-ray diffraction experiments for multiple material pedigrees, with varying crystallographic orientation distribution and β volume fractions. Depending on the thermomechanical-processing route and the heat treatment used to manufacture the alloy, Ti–6Al–4V can exist in a wide number of microstructural forms, which often results in the α and β phases either having well aligned slip systems (following the Burgers orientation relationship (BOR)) or possessing no alignment of the slip systems across the interphase boundary (not following the BOR). In this study, the fully-calibrated CPFE model is used to gain a comprehensive understanding of the deformation behavior of Ti–6Al–4V, specifically, the effect of microstructures that follow the BOR (or not) on time-dependent cyclic loading (including the effects of dwell hold times).
Direct sensitivity analysis on the parameterization of crystal plasticity models
Various methods for calibrating crystal plasticity finite element (CPFE) models lead to non-unique input parameter values, which subsequently introduce uncertainty in the predicted mechanical response. Sensitivity analysis (SA) conducted on crystal plasticity models is used to identify how variability in these parameters contribute to output uncertainty. Traditional SA on CPFE parameters uses simplified surrogate models to save computational time. However, the accuracy of the surrogate models depends on the quantity of training data used, and any modeling error can propagate into the SA results, potentially affecting their reliability. In this work, the elementary effects test (EET) method, a global SA technique using direct CPFE simulations was employed, and the results obtained were compared with the First Order Second Moment (FOSM) method. ExaConstit, an open-source GPU-enabled CPFE code, was used to perform the simulations and direct SA. The EET method was accurately able to capture the non-linear effects of all the input parameters on the output and is a valuable approach for reliably attributing parameter sensitivities in CPFE models. Based on the results, efficient strategies to perform future parameter calibration and SA are discussed. Additionally, the SA trends observed in different single crystal orientations closely mirrored the activity of the slip systems.
Non-deterministic Calibration of Crystal Plasticity Model Parameters.
Abstract not provided.
High-throughput constitutive model calibration for crystal plasticity finite element model
Explore the source record for details and available documents.
Calibrating Curved Crystals Used for Plasma Spectroscopy
The throughput and resolving power of an X-ray spectrometer that uses a curved crystal as the diffraction element is determined primarily by the crystal X-ray reflectivity properties. This poster presents a measurement technique for these crystal parameters using a simple diode source to produce a narrow spectral band. The results from measurements on concave elliptical polyethylene terephthalate (PET) crystals and convex potassium acid phthalate (KAP) crystals show large variations in the key parameters compared to those from the flat crystal.
A macro-micro approach for identifying crystal plasticity parameters for necking and failure in nickel-based alloy haynes 282
Here, this work develops a two-scales macro-micro approach to address the challenge in calibrating crystal plasticity microstructural models when samples undergo necking prior to fracture. The crystal plasticity models are crucial for predicting the materials’ plastic deformation and failure at the microstructure level, identifying the materials’ intrinsic properties as well as investigating the microstructure-properties relationships. However, after necking occurs, the experimentally measured stress-strain curves fail to reflect the materials ‘true’ stress-strain behavior and cannot be directly fitted into crystal plasticity models. The proposed macro-micro approach employs a top-down strategy to address this challenge, which has been studied with experimental tests on precipitation-strengthened Ni-based superalloy Haynes® 282®. In this approach, a macro rate-dependent anisotropic plasticity model with Voce-type hardening and Rice-Tracey damage law is first utilized to model the deformation and failure of the tensile bar, and calibrated by matching the stress-strain curves, necking strain, and reduction of area. Especially, to match the testing results under different applied strain rates, the rate-sensitivity parameter m and saturation stress in the elasticity model are modified to incorporate dependence on the local strain rate. Then, the ‘true’ stress-strain behaviors are extracted from the necking zone of the macro-model, which are used to calibrate a micro-model with explicit microstructures and governed by an extended crystal plasticity law. The consistency between the micro-model and macro-model are enforced during calibration. The calibration outcomes from the crystal plasticity model elucidate the materials intrinsic properties for slip, hardening, and failure, which is vital for further investigations into the microstructure-properties relationship and for accurate prediction of the material behavior under various test and service conditions.
Comparison of dislocation density tensor fields derived from discrete dislocation dynamics & crystal plasticity simulations of torsion.
Abstract not provided.
An asynchronous parallel high-throughput model calibration framework for crystal plasticity finite element constitutive models
Crystal plasticity finite element model (CPFEM) is a powerful numerical simulation in the integrated computational materials engineering toolboxes that relates microstructures to homogenized materials properties and establishes the structure–property linkages in computational materials science. However, to establish the predictive capability, one needs to calibrate the underlying constitutive model, verify the solution and validate the model prediction against experimental data. Bayesian optimization (BO) has stood out as a gradient-free efficient global optimization algorithm that is capable of calibrating constitutive models for CPFEM. Here in this paper, we apply a recently developed asynchronous parallel constrained BO algorithm to calibrate phenomenological constitutive models for stainless steel 304 L, Tantalum, and Cantor high-entropy alloy.
Calibrations of flat alkali acid phthalate crystals between 650 and 2400 eV using synchrotron radiation
Explore the source record for details and available documents.
Developing small vacuum spark as an x-ray source for calibration of an x-ray focusing crystal spectrometer
A new technique of x-ray focusing crystal spectrometers' calibration is the desired result. For this purpose the spectrometer is designed to register radiated copper K{alpha} and K{beta} lines by using a flat {alpha}-quartz crystal. This experiment uses pre-breakdown x-ray emissions in low vacuum of about 2.5-3 mbar. At this pressure the pinch will not form so the plasma will not radiate. The anode material is copper and the capacity of the capacitor bank is 22.6 nF. This experiment designed and mounted a repetitive triggering system to save the operator time making hundreds of shots. This emission amount is good for calibration and geometrical adjustment of an optical crystal x-ray focusing spectrometer.
Calibration of the OHREX high-resolution imaging crystal spectrometer at the Livermore electron beam ion traps
We report the calibration of the Orion High-Resolution X-ray (OHREX) imaging crystal spectrometer at the EBIT-I electron beam ion trap at Livermore. Two such instruments, dubbed OHREX-1 and OHREX-2, are fielded for plasma diagnostics at the Orion laser facility in the United Kingdom. The OHREX spectrometer can simultaneously house two spherically bent crystals with a radius of curvature of r = 67.2 cm. The focusing properties of the spectrometer allow both for larger distance to the source due to the increase in collected light and for observation of extended sources. OHREX is designed to cover a 2.5°–3° spectral range at Bragg angles around 51.3°. The typically high resolving powers at these large Bragg angles are ideally suited for line shape diagnostics. For instance, the nominal resolving power of the instrument (>10 000) is much higher than the effective resolving power associated with the Doppler broadening due to the temperature of the trapped ions in EBIT-I. The effective resolving power is only around 3000 at typical EBIT-I conditions, which nevertheless is sufficient to set up and test the instrument’s spectral characteristics. We have calibrated the spectral range for a number of crystals using well known reference lines in the first and second order and derived the ion temperatures from these lines. We have also made use of the 50 μm size of the EBIT-I source width to characterize the spatial focusing of the spectrometer.
Data for "In-Situ Relative Calibration of Bragg Crystals with Monte Carlo Line Ratio Analysis"
Explore the source record for details and available documents.
Performance and Calibration of the Crystal Calorimeter of the BABAR Detector
Explore the source record for details and available documents.
Absolute calibration of the conical crystal configuration of the zinc spectrometer (ZSPEC) at the OMEGA laser facility
In this study, we present the absolute calibration of the conical crystal for the zinc spectrometer (ZSPEC), an x-ray spectrometer at the OMEGA laser facility at the Laboratory for Laser Energetics. The ZSPEC was originally designed to measure x-ray Thomson scattering using flat or cylindrically curved highly oriented pyrolytic graphite crystals centered around Zn He-alpha emission at 9 keV. To improve the useful spectral range and collection efficiency of the ZSPEC, a conical highly annealed pyrolytic graphite crystal was fabricated for the ZSPEC. The conically bent crystal in the Hall geometry produces a line focus perpendicular to the spectrometer axis, corresponding to the detector plane of electronic detectors at large scale laser facilities such as OMEGA, extending the useful range of the spectrometer to 7–11 keV. Further, using data collected using a microfocus Mo x-ray source, we determine important characteristics of ZSPEC such as the dispersion, spatial resolution, and absolute sensitivity of the instrument. A ray-trace model of ZSPEC provides another point of agreement in calculations of the ZSPEC dispersion and crystal response.
Absolute throughput calibration of multiple spherical crystals for the Orion High-REsolution X-ray spectrometer (OHREX)
We present absolute throughput analysis of several crystals for the Orion High-REsolution X-ray (OHREX) imaging crystal spectrometer using ray tracing and experimental measurements. The OHREX spectrometer is a high-resolution x-ray spectrometer designed to measure spectral line shapes at the Orion laser facility. The spectrometer is fielded with up to two spherical crystals simultaneously covering two independent spectral ranges. Each crystal has a nominal radius of curvature of R = 67.2 cm and is fielded at a nominal Bragg angle of 51.3°. To cover different bands of interest, several different crystals are available, including Ge (111), KAP, and several cuts of quartz, whose resolving power λ/Δλ exceeds 10 000. The calibrated response of the available crystals has previously been reported from measurements at the EBIT-I electron beam ion trap at Lawrence Livermore National Laboratory. Here, we model the absolute throughput of each crystal using ray tracing and verify the results using experimental data for the quartz $(10\bar{1}1)$ crystal.
Bayesian calibration of a physics-based crystal plasticity and damage model
In this work, we present a model parameter calibration procedure for a physics-based crystal plasticity model. The calibration process utilizes a powerful statistics-based Bayesian calibration method. Calibration of the crystal plasticity parameters makes use of experimentally-measured data, i.e. compressive stress–strain response, from $\langle$100$\rangle$ and $\langle$123$\rangle$ single crystal copper dynamically loaded via Kolsky bar tests. The calibration of damage parameters is achieved using experimentally-measured free-surface velocity history data from plate impact test on $\langle$100$\rangle$ and $\langle$110$\rangle$ single crystal copper, which generates shock compression followed by dynamic tensile failure. A validation assessment is then carried out by comparing the calibrated model predictions and experimental measurements of the dynamic tensile damage generated in an impacted bicrystal copper plate. Lastly, a model-informed rationale for the experimentally-observed dependence of the spatial distribution of ductile damage (porosity) on crystallography is provided.