Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CRLB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

On the theoretical limitations in estimating thickness of a plate-like structure from a full-field single-tone response Lamb wave measurement

A persistent question in wavenumber analysis in the estimation of thickness from a steady-state wave field is identifying the theoretical sensitivity of the system. Here, a well-known trade-off between spatial frequency/wavenumber resolution and thickness resolution exists. The current work presents a calculation of the Cramer-Rao Lower bound (CRLB), specifically as applied to thickness estimates, for a 2-dimensional multi-mode waveform in Gaussian noise. Cases of near-field and far-field excitation are considered, and transducer position with respect to the scan area is also varied. Additionally, we consider the CRLB in a plate with multiple sources, simulated as sources placed on the boundary of the plate. We conclude by presenting the CRLB values in terms of frequency for various thicknesses, and by presenting optimal excitation frequencies for a nominal thickness, based on the CRLB.

47 OTHER INSTRUMENTATION↗

Cramer-Rao Lower Bound for SoOp-R-Based Root-Zone Soil Moisture Remote Sensing

Signals of opportunity (SoOp) reflectometry (SoOp-R) is a maturing field for geophysical remote sensing as evidenced by the growing number of airborne and spaceborne experiments. As this approach receives more attention, it is worth analyzing SoOp-R’s capabilities to retrieve subsurface soil moisture (SM) by leveraging communication and navigation satellite transmitters. In this research, the CRLB is used to identify the effects of variable SoOp-R parameters on the best achievable estimation error for root-zone soil moisture (RZSM). This study investigates the use of multiple frequency, polarization, and incidence angle measurement configurations on a two-layered dielectric profile. The results also detail the effects of variable SM conditions on the capability of SoOp-R systems to predict subsurface SM. The most prevalent observation is the importance of using at least two frequencies to limit uncertainties from subsurface SM estimates. If at least two frequencies are used, the CRLB of a profile is retrievable within the root-zone depending on the surface SM content as well as the number of independent measurements of the profile. For a depth of 30 cm, it is observed that a CRLB corresponding to 4% RZSM estimation accuracy is achievable with as few as 2 dual-frequency-based SoOp-R measurements. For this depth, increasing number of measurements provided by polarization and incidence angle allow for sensing of increasingly wet SM profile structures. This study, overall, details a methodology by which SoOp-R receiver system can be designed to achieve a desired CRLB using a trade-off study between the available measurements and SM profile.

Signals of Opportunity (SoOp)↗

Uncertainty amplification due to density/refractive index gradients in background-oriented schlieren experiments

Here, we theoretically analyze the effect of density/refractive index gradients on the measurement precision of background-oriented schlieren (BOS) experiments by deriving the Cramer–Rao lower bound (CRLB) for the 2D centroid estimation process. A model is derived for the diffraction limited image of a dot viewed through a medium containing density gradients that includes the effect of the experimental parameters such as the magnification and f-number. It is shown using the model that nonlinearities in the density gradient field lead to blurring of the dot image. This blurring amplifies the effect of image noise on the centroid estimation process, leading to an increase in the CRLB and a decrease in the measurement precision. The ratio of position uncertainties of a dot in the reference and gradient images is shown to be a function of the ratio of the dot diameters and dot intensities. We termed this parameter the amplification ratio (A F ), and a methodology for reporting position uncertainties in tracking-based BOS measurements is proposed. The theoretical predictions of the dot position estimation variance from the CRLB are compared to ray tracing simulations, and agreement is obtained. The uncertainty amplification is also demonstrated on experimental BOS images of flow induced by a spark discharge, where it is seen that regions of high amplification ratio correspond to regions of density gradients. This analysis elucidates the dependence of the position uncertainty on density and refractive index gradient-induced distortion parameters, provides a methodology for accounting its effect on uncertainty quantification and provides a framework for optimizing experiment design.

42 ENGINEERING↗

Near-Efficient and Non-Asymptotic Multiway Inference

We establish non-asymptotic efficiency guarantees for tensor decomposition–based inference in count data models. Under a Poisson framework, we consider two related goals: (i) parametric inference , the estimation of the full distributional parameter tensor, and (ii) multiway analysis , the recovery of its canonical polyadic (CP) decomposition factors. Our main result shows that in the rank-one setting, a rank-constrained maximum-likelihood estimator achieves multiway analysis with variance matching the Cramér–Rao Lower Bound (CRLB) up to absolute constants and logarithmic factors. This provides a general framework for studying “near-efficient” multiway estimators in finite-sample settings. For higher ranks, we illustrate that our multiway estimator may not attain the CRLB; nevertheless, CP-based parametric inference remains nearly minimax optimal, with error bounds that improve on prior work by offering more favorable dependence on the CP rank. Numerical experiments corroborate near-efficiency in the rank-one case and highlight the efficiency gap in higher-rank scenarios.

97 MATHEMATICS AND COMPUTING↗

Theoretical and simulated performance for a novel frequency estimation technique

A low complexity, open-loop, discrete-time, delay-multiply-average (DMA) technique for estimating the frequency offset for digitally modulated MPSK signals is investigated. A nonlinearity is used to remove the MPSK modulation and generate the carrier component to be extracted. Theoretical and simulated performance results are presented and compared to the Cramer-Rao lower bound (CRLB) for the variance of the frequency estimation error. For all signal-to-noise ratios (SNR's) above threshold, it is shown that the CRLB can essentially be achieved with linear complexity.

Crozier, Stewart N.↗

Error Analysis of Combined Optical-Flow and Stereo Passive Ranging

The motion of an imaging sensor causes each imaged point of the seem to describe a time trajectory on the image plane. The trajectories of all imaged points are reminiscent of a flow (eg, of liquid) which is the source of the term "optical flow". Optical-flow ranging is a method by which the stream of two-dimensional images obtained from a forward-looking forward-moving passive sensor is used to compute range to points in the field of view. Another well-known ranging method consists of triangulation based on stereo images obtained from at least two stationary sensors. In this paper we analyze the potential accuracies of a combined optical flow and stereo passive-ranging system in the context of helicopter nap-of-the-earth obstacle avoidance. The Cramer-Rao lower bound (CRLB) is developed for the combined system under the assumption of a random angular misalignment common to both cameras of a stereo pair. It is shown that the range accuracy degradations caused by misalignment is negligible for a combined optical-flow and stereo system as compared with a monocular optical-flow system.

Barniv, Yair↗

Three-Dimensional Single-Molecule Localization Microscopy in Whole-Cell and Tissue Specimens

Super-resolution microscopy techniques are versatile and powerful tools for visualizing organelle structures, interactions, and protein functions in biomedical research. However, whole-cell and tissue specimens challenge the achievable resolution and depth of nanoscopy methods. We focus on three-dimensional single-molecule localization microscopy and review some of the major roadblocks and developing solutions to resolving thick volumes of cells and tissues at the nanoscale in three dimensions. These challenges include background fluorescence, system- and sample-induced aberrations, and information carried by photons, as well as drift correction, volume reconstruction, and photobleaching mitigation. We also highlight examples of innovations that have demonstrated significant breakthroughs in addressing the abovementioned challenges together with their core concepts as well as their trade-offs.

59 BASIC BIOLOGICAL SCIENCES↗