Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CREDIT EXPOSURES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Computing for Finance

The finance sector is one of the driving forces for the use of distributed or Grid computing for business purposes. The speakers will review the state-of-the-art of high performance computing in the financial sector, and provide insight into how different types of Grid computing – from local clusters to global networks - are being applied to financial applications. They will also describe the use of software and techniques from physics, such as Monte Carlo simulations, in the financial world. There will be four talks of 20min each. The talk abstracts and speaker bios are listed below. This will be followed by a Q&A; panel session with the speakers. From 19:00 onwards there will be a networking cocktail for audience and speakers. This is an EGEE / CERN openlab event organized in collaboration with the regional business network rezonance.ch. A webcast of the event will be made available for subsequent viewing, along with powerpoint material presented by the speakers. Attendance is free and open to all. Registration is mandatory via www.rezonance.ch, including for CERN staff. 1. Overview of High Performance Computing in the Financial Industry Michael Yoo, Managing Director, Head of the Technical Council, UBS Presentation will describe the key business challenges driving the need for HPC solutions, describe the means in which those challenges are being addressed within UBS (such as GRID) as well as the limitations of some of these solutions, and assess some of the newer HPC technologies which may also play a role in the Financial Industry in the future. Speaker Bio: Michael originally joined the former Swiss Bank Corporation in 1994 in New York as a developer on a large data warehouse project. In 1996 he left SBC and took a role with Fidelity Investments in Boston. Unable to stay away for long, he returned to SBC in 1997 while working for Perot Systems in Singapore. Finally, in 1998 he formally returned to UBS in Stamford following the merger with SBC and has remained with UBS for the past 9 years. During his tenure at UBS, he has had a number of leadership roles within IT in development, support and architecture. In 2006 Michael relocated to Switzerland to take up his current role as head of the UBS IB Technical Council, responsible for the overall technology strategy and vision of the Investment Bank. One of Michael's key responsibilities is to manage the UBS High Performance Computing Research Lab and he has been involved in a number of initiatives in the HPC space. 2. Grid in the Commercial WorldFred Gedling, Chief Technology Officer EMEA and Senior Vice President Global Services, DataSynapse Grid computing gets mentions in the press for community programs starting last decade with Seti@Home. Government, national and supranational initiatives in grid receive some press. One of the IT-industries' best-kept secrets is the use of grid computing by commercial organizations with spectacular results. Grid Computing and its evolution into Application Virtualization is discussed and how this is key to the next generation data center. Speaker Bio: Fred Gedling holds the joint roles of Chief Technology Officer for EMEA and Senior Vice President of Global Services at DataSynapse, a global provider of application virtualisation software. Based in London and working closely with organisations seeking to optimise their IT infrastructures, Fred offers unique insights into the technology of virtualisation as well as the methodology of establishing ROI and rapid deployment to the immediate advantage of the business. Fred has more than fifteen years experience of enterprise middleware and high-performance infrastructures. Prior to DataSynapse he worked in high performance CRM middleware and was the CTO EMEA for New Era of Networks (NEON) during the rapid growth of Enterprise Application Integration. His 25-year career in technology also includes management positions at Goldman Sachs and Stratus Computer. Fred holds a First Class Bsc (Hons) degree in Physics with Astrophysics from the University of Leeds and had the privilege of being a summer student at CERN.3. Opportunities for gLite in finance and related industriesAdam Vile, Head of Grid, HPC and Technical Computing, Excelian Ltd.gLite, the Grid software developed by the EGEE project, has been exceedingly successful as an enabling infrastructure, and has been a massive success in bringing together scientific and technical communities to provide the compute power to address previously incomputable problems. Not so in the finance industry. In its current form gLite would be a business disabler. There are other middleware tools that solve the finance communities compute problems much better. Things are moving on, however. There are moves afoot in the open source community to evolve the technology to address other, more sophisticated needs such as utility and interactive computing. In this talk, I will describe how Excelian is providing Grid consultancy services for the finance community and how, through its relationship to the EGEE project, Excelian is helping to identify and exploit opportunities as the research and business worlds converge. Because of the strong third party presence in the finance industry, such opportunities are few and far between, but they are there, especially as we expand sideways into related verticals such as the smaller hedge funds and energy companies. This talk will give an overview of the barriers to adoption of gLite in the finance industry and highlight some of the opportunities offered in this and related industries as the ideas around Grid mature. Speaker Bio: Dr Adam Vile is a senior consultant and head of the Grid and HPC practice at Excelian, a consultancy that focuses on financial markets professional services. He has spent many years in investment banking, as a developer, project manager and architect in both front and back office. Before joining Excelian he was senior Grid and HPC architect at Barclays Capital. Prior to joining investment banking, Adam spent a number of years lecturing in IT and mathematics at a UK University and maintains links with academia through lectures, research and through validation and steering of postgraduate courses. He is a chartered mathematician and was the conference chair of the Institute of Mathematics and its Applications first conference in computational Finance. 4. From Monte Carlo to Wall Street Daniel Egloff, Head of Financial Engineering Computing Unit, Zürich Cantonal Bank High performance computing techniques provide new means to solve computationally hard problems in the financial service industry. First I consider Monte Carlo simulation and illustrate how it can be used to implement a sophisticated credit risk management and economic capital framework. From a HPC perspective, basic Monte Carlo simulation is embarrassingly parallel and can be implemented efficiently on distributed memory clusters. Additional difficulties arise for adaptive variance reduction schemes, if the information content in a sample is very small, and if the amount of simulated date becomes huge such that incremental processing algorithms are indispensable. We discuss the business value of an advanced credit risk quantification which is particularly compelling in these days. While Monte Carlo simulation is a very versatile tool it is not always the preferred solution for the pricing of complex products like multi asset options, structured products, or credit derivatives. As a second application I show how operator methods can be used to develop a pricing framework. The scalability of operator methods relies heavily on optimized dense matrix-matrix multiplications and requires specialized BLAS level-3 implementations provided by specialized FPGA or GPU boards. Speaker Bio: Daniel Egloff studied mathematics, theoretical physics, and computer science at the University of Zurich and the ETH Zurich. He holds a PhD in Mathematics from University of Fribourg, Switzerland. After his PhD he started to work for a large Swiss insurance company in the area of asset and liability management. He continued his professional career in the consulting industry. At KPMG and Arthur Andersen he consulted international clients and implemented quantitative risk management solutions for financial institutions and insurance companies. In 2002 he joined Zurich Cantonal Bank. He was assigned to develop and implement credit portfolio risk and economic capital methodologies. He built up a competence center for high performance and cluster computing. Currently, Daniel Egloff is heading the Financial Computing unit in the ZKB Financial Engineering division. He and his team is engineering and operating high performance cluster applications for computationally intensive problems in financial risk management.

BUSINESS VALUE↗

Regulatory perspective of boiling water reactor peak reactivity credit in spent fuel storage and transportation - 14592

The U.S. Nuclear Regulatory Commission (NRC) performs reviews of applications for spent nuclear fuel transportation packages and storage casks to ensure pertinent safety regulations are met. Among other acceptance criteria, these regulations require that the package be subcritical under a variety of normal, off-normal and accident conditions. Currently, all spent nuclear fuel transportation packages and storage casks assume fresh fuel (i.e., the fuel is unirradiated) in their criticality safety analyses for boiling water reactor (BWR) fuels. Reviews using this conservative assumption are less complex. The fresh fuel assumption for BWR fuel does not allow the presence of gadolinium (often called the 'fresh fuel no-Gad' assumption), an integral burnable absorber present in nearly all BWR fuel assemblies. More recently, applicants began requesting credit for the reactivity reduction due to depletion. This credit is commonly referred to as 'burnup credit' (BUC). As of today, NRC recommends that only analyses for Pressurized Water Reactor (PWR) spent fuel implement BUC. This is due to the fact there is limited directly applicable data available to benchmark codes for depletion and reactivity calculations for BWR BUC analyses, and determining the most reactive irradiation conditions is much less straightforward than for PWR BUC analyses. Similar to what was done for PWR BUC, the NRC staff and its contractors have begun identifying and prioritizing significant technical issues so that a technical basis for the allowance of BWR BUC can be developed. BWR fuel exhibits a peak in reactivity where initial gadolinium is depleted. Crediting burnup at this point is generally referred to as using a 'peak reactivity method'. This is a conservative approach and a method routinely used in BWR spent fuel pool criticality analyses. NRC is implementing a two-phased approach in investigating BWR BUC. Phase 1 investigates peak reactivity credit and Phase 2 evaluates BUC at a typical discharge exposure. This paper discusses peak reactivity credit and its history in regulatory analyses, challenges the NRC expects in reviewing an application requesting peak BWR reactivity credit for a spent fuel transportation package or storage cask, the work that is being performed by NRC contractors to address these challenges, and future work on peak reactivity credit and full BWR BUC. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Pressurization Analysis for Heating of a Screw Top Utility Can Loaded With Plutonium Oxide Powder by a 1273 K Fire

The documented safety analysis for the Savannah River National Laboratory (SRNL) evaluates the consequences of a postulated 1273 K fire in a glovebox. The radiological dose consequences for a pressurized release of plutonium oxide powder during such a fire depend on the maximum pressure that is attained inside the oxide storage containers. The oxide storage configuration selected for analysis is can/bag/can, comprised of oxide powder inside an 8.38 × 10 -6 m 3 stainless steel B vial inside 0.006 kg of polyethylene bagging inside a one-quart screw top utility can of the type commonly used to package solvents or rubber cements. To enable evaluation of the dose consequences, temperature and pressure transients have been calculated for exposure of a typical set of storage containers to the fire. The pressurization analysis credits venting to and from the B vial but does not credit venting or leakage from the can. Due to the low rate of venting from the B vial into the can gas space, the can pressure is nearly independent of the B vial pressure. Calculated maximum pressures are compared to the utility can burst pressure. In lieu of a structural analysis of the utility cans, burst pressures and leakage rates were measured using compressed nitrogen gas. The measured gauge burst pressure was 0.250 ± 0.043 MPa. The measured burst pressures are lower than the calculated maximum pressure due to fire exposure, indicating that the utility cans could burst during exposure to a 1273 K fire.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Target Control and Protection Systems Lessons from SNS Operations

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory has been in operations since 2006 and proposes a project to build a Second Target Station (STS) to effectively double potential scientific output. The SNS target controls operate in a harsh environment which includes high radiation, exposure to gaseous radionuclides, and activated liquid mercury and mercury vapor. These conditions necessitate protective interlocks and credited controls for protection functions to ensure proper response to off-normal conditions. In order to inform the design of target controls for the STS, we have examined lessons learned during SNS operations regarding the design and implementation of the control and protection systems for the first target station (FTS). This paper will examine various aspects of the performance of the target control and protection systems including reliability, maintainability and sustainability given the challenging environment created by 1.4 MW operations. Specific topics include distributed control of various target subsystems, response to loss of power, selection of nuclear grade instrumentation, and applying these lessons to the design for the STS project.

Humphreys, Dana↗

The Advancement of Cool Roof Standards in China from 2010 to 2015

Since the initiation of the U.S.-China Clean Energy Research Center-Building Energy Efficiency (CERC-BEE) cool roof research collaboration between the Lawrence Berkeley National Laboratory Heat Island Group and Chinese institutions in 2010, new cool surface credits (insulation trade- offs) have been adopted in Chinese building energy efficiency standards, industry standards, and green building standards. JGJ 75-2012: Design Standard for Energy Efficiency of Residential Buildings in Hot Summer and Warm Winter Zone became the first national level standard to provide cool surface credits. GB/T 50378-2014: Assessment Standard for Green Building is the first national level green building standard that offers points for heat island mitigation. JGJ/T 359-2015: Technical Specification for Application of Architectural Reflective Thermal Insulation Coating is the first industry standard that offers cool coating credits for both public and residential buildings in all hot-summer climates (Hot Summer/Cold Winter, Hot Summer/Warm Winter). As of December 2015, eight provinces or municipalities in hot-summer regions have credited cool surfaces credits in their residential and/or public building design standards; five other provinces or municipalities in hot-summer regions recommend, but do not credit, the use of cool surfaces in their building design standards. Cool surfaces could be further advanced in China by including cool roof credits for residential and public building energy efficiency standards in all hot-summer regions; developing a standardized process for natural exposure and aged-property rating of cool roofing products; and adapting the U.S.-developed laboratory aging process for roofing materials to replicate solar reflectance changes induced by natural exposure in China.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tax Credits for Clean Electricity: The Distributional Impacts of Supply-Push Policies in the Power Sector

We evaluate distributional and efficiency consequences of the bulk power clean electricity tax credits authorized by the 2022 Inflation Reduction Act. To do so, we link detailed electricity capacity expansion, computable general equilibrium, microsimulation, and air pollution models to estimate economic welfare and health incidence across demographic groups. We evaluate trade-offs between policy efficiency and income progressivity by comparing the tax credits to cap-and-trade policies. The tax credits encourage increased clean electricity investment, resulting in a reallocation of capital from elsewhere in the economy, higher prices for capital and other goods, lower power prices, and lower emissions. The tax credits yield progressive outcomes for economic welfare at the expense of efficiency while all modeled policies demonstrate progressivity in health impacts. The health benefits, absent climate benefits, exceed total policy costs and provide greater benefits for low-income and historically marginalized households given coincidence of household locations and emissions exposure intensity.

distributional impacts↗

Fire- and Water-Resistant Prefilter

The goal of this project was to modify existing LLNL ceramic HEPA filter technology to create ceramic prefilters, which could first be implemented in nuclear facilities or hospitals and universities. The objectives were as follows: 1) Demonstrate sealing technology capable of withstand ≥ 400°C, 2) Design and fabricate a ceramic prefilter unit for flow rates ≥ 50 cfm, 3) Test prefilter prototype filtration efficiency and pressure drop before and after a relevant thermal exposure. Concurrently to prototype creation was a preliminary effort to develop a custom nuclear prefilter sealant, improving upon what is commercially available. An advantage to using prefilters that are not credited for HEPA filtration, but to protect HEPA filters in nuclear ventilation systems, is that absolute qualified performance to HEPA standards (e.g. pressure drop, filtration efficiency) is not required. This prefilter prototype aligns our technology with the more viable, lower risk market entry point which can be used to establish costs, performance and manufacturing principles necessary to overcome the primary market barrier.

36 MATERIALS SCIENCE↗

Quantification of reactivity margin in BWR spent fuel pools

Boiling water reactor (BWR) spent fuel pool (SFP) criticality safety analyses typically use the in-core k{sub inf} criterion methodology to demonstrate margin to safety. This method models all the fuel in the SFP with a limiting lattice design at a peak reactivity just above a specific in-core k{sub inf} limit. To bound all the fuel in the pool and future fuel with reasonable margin, these limits are often set conservatively high compared to the peak reactivities of actual BWR bundle designs. When current regulatory expectations are met for the quantification of bias and uncertainty adders to the criticality analyses, some results are quantified that are close to the 0.95 in-rack reactivity limit required by 10CFR50.68. The small margins being calculated in the criticality safety analyses have resulted in concerns that SFPs have less margin to safety than was present in the past; however, inherent in the peak reactivity in-core k{sub inf} criterion methodology used to assess these margins is a very conservative model of the fuel. While it is known that all the fuel in a BWR SFP is typically burned well past its peak reactivity exposure, it has been unknown how much reactivity margin could be quantified if bundles were modeled more realistically by accounting for their actual discharge exposure profiles, operational void fractions, control histories, and depletion fuel temperatures. In this study, fuel bundles were depleted to their explicit nodal discharge exposure while accounting for actual operational conditions defined by GEH/GNF's core simulator code, PANACEA. The use of these depleted isotopics in the criticality safety analysis is commonly referred to as taking 'burn-up credit' in the analysis. This paper provides a quantification of the reactivity margin available from burn-up credit in two currently operating BWR spent fuel pools. The evaluation demonstrates that many of the bundles in these storage configurations are significantly below the in-rack reactivity limit, even with the necessary bias and uncertainty adders included. The utilization of BWR burnup credit appears to be an attractive solution to consider when evaluating options for reduced neutron absorber credit or for quantifying additional margin to the regulatory in-rack k{sub eff} limit. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Apparent Monte Carlo Source Convergence Problem with BWR Fuel Depleted with Partial Control Blade Insertion

Oak Ridge National Laboratory (ORNL) and the US Nuclear Regulatory Commission (NRC) have initiated a multiyear project to investigate application of burnup credit (BUC) to boiling-water reactor (BWR) fuel in storage and transportation casks and spent fuel pools (SFPs). Ideally, a single combination of all operating parameters including moderator density and axial burnup profiles, control blade exposure, and others can be identified to allow a simple, bounding approach to BWR BUC. One aspect of this investigation involves examining the effect of control blade insertion during operation on discharged assembly reactivity. In the course of these calculations, an apparent source convergence problem was discovered for fuel that has experienced partial blade insertion for the entire lifetime of the assembly. The source convergence problem appears not to impact k{sub eff}, but it manifests in predictions of the axial fission density profile. This phenomenon is of interest in identifying areas of concern with BWR BUC since it has not been studied as thoroughly as BUC for pressurized-water (PWR) reactor fuel. There may also be interest in this configuration for further study of a realistic source Monte Carlo convergence problem as opposed to some earlier manufactured source convergence problems through careful selection of initial conditions. This summary presents the depletion conditions used to generate the problem, a description of the models, a background based on well-behaved calculations, the identification of the problem, and attempts made to resolve the problem. Only a brief description of the depletion conditions and models is possible within the limited scope of this summary. Finally, conclusions are presented. This summary identifies a source convergence problem in the process of investigating BUC for BWR spent fuel. The depletion scenario which created the depleted fuel and burnable absorber compositions included a control blade inserted in the bottom 14 nodes throughout the entire depletion. This insertion is slightly over half the length of the assembly, and it appears to create two regions of nearly equal reactivity. As expected, one region is near the top of the assembly, and the other region is near the middle of the assembly. This node includes significant {sup 239}Pu generation as a result of rodded operation, but it is also the top node of the full lattice zone. While the calculated k{sub eff} values appear to be statistically equivalent, the axial neutron production profile varies significantly among independent simulations of the same model. A range of standard approaches has been used to attempt to resolve the source convergence problem and determine the true axial neutron production profile. This profile is of interest in cask criticality safety analysis because it influences the interaction among assemblies loaded in the cask. The forthcoming SCALE 6.2 release will include source convergence testing based on Shannon entropy, which may assist in identifying these types of problems in the future. It should be noted that this source convergence problem results from the depletion conditions and the final distribution of fissile and absorber material within the discharged fuel assembly. The results, while entirely generated within the SCALE code system, are representative of any Monte Carlo program attempting to calculate k{sub eff} for such a system. The most important conclusion of this work is that the BUC criticality safety community must be aware of the potential for this type of source convergence problem. Analysts must approach such partially rodded scenarios with caution and critically examine the results. Fortunately, it is extremely unlikely that BWR assemblies would experience the bladed operation necessary to create this particular source convergence problem. These results may also have some bearing on the analysis of PWR BUC for new plant designs such as AP1000 that incorporate significant rodded operations. In a broader context, the source convergence problem identified here could have been magnified if it had occurred in a Monte Carlo depletion simulation. It may be possible to identify this type of problem in a depletion calculation by comparing the apparently converged fluxes between steps to ensure that no oscillations or other serious shifts are occurring. The depletion calculations performed in this work were performed with a two-dimensional deterministic code and are therefore not subject to this problem. These results may also raise questions about the validity of 2D depletion models with extruded geometry in the 3D k{sub eff} calculation. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

3013 Inner Can Lid Leak Test System Development

Contained in this report is a description of the 3013 inner container lid leak detection system, a listing of the data collected to validate the system and a statistical analysis of collected data. The 3013 Container Surveillance Program provides assessment criteria and evaluates 3013 containers selected from the storage inventory for potential degradation mechanisms. The 3013 outer container is the boundary credited to prevent release of material to the environment. The integrity of the outer container is only at risk if the inner container loses its seal and allows corrosive gases to diffuse into the outer container. To date, the determination of potential outer container exposure to corrosive gases has been through comparison of the gas analysis of the annular space and the inner container. If the two volumes have the same gas composition and pressure, then the inner container may have leaked. The leak detection system described in this report will provide a direct measurement of the integrity of the inner container, and if approved, will provide for the elimination of gas analysis. The inner container lid leak testing system consists of two basic parts: the Agilent leak testing instrument and the leak test fixture. The test fixture base provides the connection between the leak test instrument and the test sample. This connection allows helium to flow into the leak detector when a leak path exists in the test sample allowing leak measurement to be performed. The tests reported here were conducted in a cold lab using a configuration very similar, but not identical to, the configuration anticipated when installed in a glove box. A total of sixty-five leak rate measurements were made on 10 containers and the data is included in the report. The data analysis shows that the leak detection system can identify leaks in the lid, including the weld and heat affected zone of 3013 inner containers, during destructive examination. The measurements taken support that a 3013 IC lid with a leak rate value greater than 2.0 x 10 -7 atm cc/sec will be identified using the leak test system prior to introduction into a glove box. These results from the baseline for future tests of the leak test system after it is installed in the glove box for use as part of surveillance DE.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stabilization of Residual Contamination with Alternative Materials - 19404

Since 2015, Savannah River National Laboratory (SRNL) in conjunction with Florida International University (FIU) have been investigating the applicability of intumescent coatings as radiological contamination fixatives for stabilization of residual materials after decontamination efforts have concluded. Intumescent coatings are designed to prevent heat transfer to a protected substrate and are typically used in both the aerospace industry to protect components from thermal shock and in building design to protect building joints that may fail in the event of a fire. For this work, these materials are examined for their ability to reduce worker risk by fixating residual contamination and lower the impact of a release in a scenario that breaches containment of a contaminated building and subsequently induces a large-scale fire by crediting their fire-retardant attributes. Initial studies of intumescent coatings and commercial fixatives included performance in direct flame, varied environmental conditions (20-110 F or -6.67 C, 10-95% relative humidity), adhesion studies to stainless steel after curing in varied environmental conditions, and radiological exposure. Of all the materials tested, many were found to be inadequate in one or more of these areas. These materials failed in one or more of three characteristic ways: 1) through delamination at reduced temperatures (≤40 F or 4.44 C) or from even moderate handling, 2) melting off the substrate at elevated temperatures (≥90 F or 32.22 C), 3) proving to be flammable and promote smoke propagation. Failure in these ways results in the potential for a subsequent release of the fixated contamination in the event of water presence/absence or direct flame. Using these results as a platform for the best in class identified material that did not experience failure in any of these tests, SRNL and FIU targeted the plutonium-238 contaminated hot cells within Savannah River Site (SRS) Building 235-F as a characteristic test bed to benchmark an intumescent coating used as a contaminant fixative. Through discussion with the SRS 235-F Risk Reduction personnel, appropriate hazards and performance metrics were discussed and a cold demonstration was performed in a hot cell mockup located at SRS. The application methods were proven functional in the cold mock up, and these intumescent coatings were subsequently utilized in the Savannah River Site Building 235-F's Plutonium Fuel Form (PuFF) Facility to aid in stabilization of plutonium-238 in both a contaminated hot cell and Entry Hood in September 2018. Presented in this work is the overview of the application process, associated working considerations for introduction of equipment and materials into the facility, lessons learned, and lifetime monitoring data to date. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solar-Reflective “Cool” Walls: Benefits, Technologies, and Implementation

Raising the albedo (solar reflectance) of a building’s walls reduces unwanted solar heat gain in the cooling season. This saves electricity and lowers peak power demand by decreasing the need for air conditioning. It can also cool the outside air, which can mitigate the urban heat island effect and also improve air quality by slowing the reactions that produce smog. This project quantified the energy savings, peak demand reduction, urban cooling, and air quality improvements attainable from solar-reflective “cool” walls in California; collaborated with industry to assess the performance of existing cool-wall technologies, and to develop innovative cool-wall solutions; and worked with state and federal government agencies, utilities, and industry to create a cool-wall infrastructure, including application guidelines, a product rating program, incentives, and building code credits. Simulations indicate that cool walls provide annual energy savings, peak demand reduction, annual emission reduction, and summer heat island mitigation benefits comparable to those yielded by cool roofs, and are helpful across California and in most of the southern half of the United States (that is, in U.S. climate zones 1—4). Natural exposure trials conducted at three sites in California and another three sites across the United States indicate that cool-wall materials tend to stay clean and reflective. Significant advances were made in novel cool-wall technologies, such as fluorescent cool pigments that expand the color palette for cool-wall products. We prepared guidelines for the climate- and building-appropriate use of cool walls, convened a stakeholder workshop, and created a working group. Ongoing efforts seek to introduce or expand cool-wall provisions in building energy standards, green building programs, and energy efficiency incentive programs, and to develop a cool-wall product rating system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar-Reflective “Cool” Walls: Benefits, Technologies, and Implementation

Raising the albedo (solar reflectance) of a building’s walls reduces unwanted solar heat gain in the cooling season. This saves electricity and lowers peak power demand by decreasing the need for air conditioning. It can also cool the outside air, which can mitigate the urban heat island effect and also improve air quality by slowing the reactions that produce smog. This project quantified the energy savings, peak demand reduction, urban cooling, and air quality improvements attainable from solar-reflective “cool” walls in California; collaborated with industry to assess the performance of existing cool-wall technologies, and to develop innovative cool-wall solutions; and worked with state and federal government agencies, utilities, and industry to create a cool-wall infrastructure, including application guidelines, a product rating program, incentives, and building code credits. Simulations indicate that cool walls provide annual energy savings, peak demand reduction, annual emission reduction, and summer heat island mitigation benefits comparable to those yielded by cool roofs, and are helpful across California and in most of the southern half of the United States (that is, in U.S. climate zones 1—4). Natural exposure trials conducted at three sites in California and another three sites across the United States indicate that cool-wall materials tend to stay clean and reflective. Significant advances were made in novel cool-wall technologies, such as fluorescent cool pigments that expand the color palette for cool-wall products. We prepared guidelines for the climate- and building-appropriate use of cool walls, convened a stakeholder workshop, and created a working group. Ongoing efforts seek to introduce or expand cool-wall provisions in building energy standards, green building programs, and energy efficiency incentive programs, and to develop a cool-wall product rating system.

utility incentives↗

Infiltration Effects on Residential Pollutant Concentrations for Continuous and Intermittent Mechanical Ventilation Approaches

The prevailing residential ventilation standard in North America, American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Standard 62.2, specifies volumetric airflow requirements as a function of the overall size of the home and the number of bedrooms, assumes a fixed, minimal amount of infiltration, and requires mechanical ventilation to achieve the remainder. The standard allows for infiltration credits and intermittent ventilation patterns that can be shown to provide comparable performance. Whole-house ventilation methods have a substantial effect on time-varying indoor pollutant concentrations. If alternatives specified by Standard 62.2, such as intermittent ventilation, are used, short-term pollutant concentrations could exceed acute health standards even if chronic health standards are met.The authors present a methodology for comparing ASHRAE- and non-ASHRAE-specified ventilation scenarios on relative indoor pollutant concentrations. We use numerical modeling to compare the maximum time-averaged concentrations for acute exposure relevant (1-hour, 8-hour, 24-hour ) and chronic exposure relevant (1-year) time periods for four different ventilation scenarios in six climates with a range of normalized leakage values. The results suggest that long-term concentrations are the most important metric for assessing the effectiveness of whole-house ventilation systems in meeting exposure standards and that, if chronic health exposure standards are met, acute standards will also be met.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SRNL's Lessons Learned from the University of Nevada Reno{sup TM} Nuclear Packaging Internships - 19464

The U.S. Department of Energy's Packaging Certification Program (DOE PCP) and the University of Nevada, Reno (UNR) Mechanical Engineering Department have developed an accredited, graduate level nuclear packaging certificate. The mission is to ensure that the DOE staff and users of PCP services are knowledgeable and competent in packaging and transportation activities. Since 2008, the Savannah River National Laboratory (SRNL) has been teaching two classes for the DOE PCP Packaging University. This paper introduces a recently added third class, where SRNL provided Site Supervisors, targeted toward engineering interns. As part of ensuring a future workforce, the Packaging Technology and Transportation Engineering Group (PT and TE) at Savannah River National Laboratory (SRNL) normally employs two to three summer interns each year. The internships provide SRNL innovative s performing valuable research and support work related to package certification. It also provides SRNL the opportunity to bring in perspective engineers on 'trial-basis.' The interns benefit by learning valuable career skills and gaining exposure to a broad-based career field in the field of packaging. As part of the job specific training, the summer interns are provided an overview of package design, testing, and certification. This includes package operations, containment vessel leak testing, and SARP preparation. Two years ago, SRNL recognized the efficiency of using the SRNL-taught courses for the summer interns working in SRNL PT and TE. SRNL requested that UNR allow the PT and TE two summer interns, who were rising college juniors, to enroll in the SRNL-taught courses for graduate credit. UNR agreed and allowed the interns to enroll under a special admission status. Since that time, UNR developed a new class within the Graduate Certificate in Nuclear Packaging (GCNP), for the summer intern research work. This new class offers a formalized framework for the summer interns to conduct research, while ensuring that the research is performed in a rigor consistent with an accredited college level setting. Last summer, the SRNL PT and TE had three summer interns - all participating in the new course, UNR ME-699 Nuclear Packaging Summer Internship - with each earning three graduate credits from UNR in mechanical engineering. This paper provides a brief overview of the DOE PCP Packaging University/ UNR GCNP, a discussion of SRNL's use of summer interns as a tool to recruit and train the future workforce, and lessons learned from having last year's three SRNL PPT and TE summer interns enroll in the UNR Packaging Internship Class. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Final corrective action study for the former CCC/USDA facility in Ramona, Kansas.

Past operations at a grain storage facility formerly leased and operated by the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) in Ramona, Kansas, resulted in low concentrations of carbon tetrachloride in groundwater that slightly exceed the regulatory standard in only one location. As requested by the Kansas Department of Health and Environment, the CCC/USDA has prepared a Corrective Action Study (CAS) for the facility. The CAS examines corrective actions to address groundwater impacted by the former CCC/USDA facility but not releases caused by other potential groundwater contamination sources in Ramona. Four remedial alternatives were considered in the CAS. The recommended remedial alternative in the CAS consists of Environmental Use Control to prevent the inadvertent use of groundwater as a water supply source, coupled with groundwater monitoring to verify the continued natural improvement in groundwater quality. The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) has directed Argonne National Laboratory to prepare a Corrective Action Study (CAS), consistent with guidance from the Kansas Department of Health and Environment (KDHE 2001a), for the CCC/USDA grain storage facility formerly located in Ramona, Kansas. This effort is pursuant to a KDHE (2007a) request. Although carbon tetrachloride levels at the Ramona site are low, they remain above the Kansas Tier 2 risk-based screening level (RBSL) and the U.S. Environmental Protection Agency (EPA) maximum contaminant level (MCL) of 5 {micro}g/L (Kansas 2003, 2004). In its request for the CAS, the KDHE (2007a) stated that, because of these levels, risk is associated with potential future exposure to contaminated groundwater. The KDHE therefore determined that additional measures are warranted to limit future use of the property and/or exposure to contaminated media as part of site closure. The KDHE further requested comparison of at least two corrective action alternatives to the 'no-action' alternative, as the basis for the Draft Corrective Action Decision for the site. The history and nature of the contamination and previous investigations are summarized in Section 2. Also included in Section 2 is an evaluation of human and environmental targets and potential exposure pathways. Section 3 describes the corrective action goals and applicable or relevant and appropriate requirements (ARARs). Section 4 describes four alternatives, Section 5 analyzes the alternatives in detail, and Section 6 compares the alternatives. Section 6 also includes a summary and a recommended corrective action.

54 ENVIRONMENTAL SCIENCES↗

Estimation of Dose from Potential Radionuclide Emissions from the Sample Preparation Laboratory at the Materials and Fuels Complex

The Sample Preparation Laboratory (SPL) at the Materials and Fuels Complex will perform sample preparation, examination, and mechanical-property testing of highly irradiated materials. The purpose of this report is to document calculation of the estimated dose at public receptor locations from potential radionuclide releases to the atmosphere from SPL. Atmospheric dispersion and dose calculations were performed with the computer model CAP88-PC Version 4 in accordance with the requirements of Code of Federal Regulations (CFR), Title 40, “Protection of the Environment,” Part 61, “National Emission Standards for Hazardous Air Pollutants (NESHAPs),” Subpart H, “National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities” (40 CFR 61, Subpart H 2010). Emission potentials were calculated based on the methodology in 40 CFR Part 61, Appendix D and additional guidance/approval by EPA Region 10 [see letter from Donald Dossett (EPA Region 10) to Tim Safford (DOE-ID), Oct 19, 2017 (CCN 241475)] for solid materials that undergo heating. Estimates of total effective dose are based on low-level chronic exposure. The potential maximum dose to a member of the public was calculated to be 0.02 mrem/year based on an estimated 16 g of the 30 kg source term (0.053%) being exposed to very high temperatures associated with electrical-discharge machining (EDM) and the remaining material heated to 100°C. Calculations show the maximum dose could be as high as 0.05 mrem/year if the remaining material were heated to 1400°C (i.e., the melting point of stainless steel). The potential maximum dose to a public receptor from emissions at SPL is not expected to exceed 0.1 mrem/year (1% of the standard) so long as the material impacted by EDM does not exceed 56 g (3.5 times the expected mass of 16 g and less than 0.2% of the total source term), and the remaining material is not heated to temperatures greater than 1400°C. It should be noted that credit for HEPA filtration does not impact the dose results because the dose is dominated by radionuclides that have exceeded their boiling point; thus, no credit for HEPA filtration may be applied to the emission factor.

99 GENERAL AND MISCELLANEOUS↗

Holographic Optical Data Storage

Although the basic idea may be traced back to the earlier X-ray diffraction studies of Sir W. L. Bragg, the holographic method as we know it was invented by D. Gabor in 1948 as a two-step lensless imaging technique to enhance the resolution of electron microscopy, for which he received the 1971 Nobel Prize in physics. The distinctive feature of holography is the recording of the object phase variations that carry the depth information, which is lost in conventional photography where only the intensity (= squared amplitude) distribution of an object is captured. Since all photosensitive media necessarily respond to the intensity incident upon them, an ingenious way had to be found to convert object phase into intensity variations, and Gabor achieved this by introducing a coherent reference wave along with the object wave during exposure. Gabor's in-line recording scheme, however, required the object in question to be largely transmissive, and could provide only marginal image quality due to unwanted terms simultaneously reconstructed along with the desired wavefront. Further handicapped by the lack of a strong coherent light source, optical holography thus seemed fated to remain just another scientific curiosity, until the field was revolutionized in the early 1960s by some major breakthroughs: the proposition and demonstration of the laser principle, the introduction of off-axis holography, and the invention of volume holography. Consequently, the remainder of that decade saw an exponential growth in research on theory, practice, and applications of holography. Today, holography not only boasts a wide variety of scientific and technical applications (e.g., holographic interferometry for strain, vibration, and flow analysis, microscopy and high-resolution imagery, imaging through distorting media, optical interconnects, holographic optical elements, optical neural networks, three-dimensional displays, data storage, etc.), but has become a prominent am advertising, and security medium as well. The evolution of holographic optical memories has followed a path not altogether different from holography itself, with several cycles of alternating interest over the past four decades. P. J. van Heerden is widely credited for being the first to elucidate the principles behind holographic data storage in a 1963 paper, predicting bit storage densities on the order of 1/lambda(sup 3) with source wavelength lambda - a fantastic capacity of nearly 1 TB/cu cm for visible light! The science and engineering of such a storage paradigm was heavily pursued thereafter, resulting in many novel hologram multiplexing techniques for dense data storage, as well as important advances in holographic recording materials. Ultimately, however, the lack of such enabling technologies as compact laser sources and high performance optical data I/O devices dampened the hopes for the development of a commercial product. After a period of relative dormancy, successful applications of holography in other arenas sparked a renewed interest in holographic data storage in the late 1980s and the early 1990s. Currently, with most of the critical optoelectronic device technologies in place and the quest for an ideal holographic recording medium intensified, holography is once again considered as one of several future data storage paradigms that may answer our constantly growing need for higher-capacity and faster-access memories.

Timucin, Dogan A.↗