Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CORONARIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Coronary artery analysis: Computer-assisted selection of best-quality segments in multiple-phase coronary CT angiography

Purpose: The authors are developing an automated method to identify the best-quality coronary arterial segment from multiple-phase coronary CT angiography (cCTA) acquisitions, which may be used by either interpreting physicians or computer-aided detection systems to optimally and efficiently utilize the diagnostic information available in multiple-phase cCTA for the detection of coronary artery disease. Methods: After initialization with a manually identified seed point, each coronary artery tree is automatically extracted from multiple cCTA phases using our multiscale coronary artery response enhancement and 3D rolling balloon region growing vessel segmentation and tracking method. The coronary artery trees from multiple phases are then aligned by a global registration using an affine transformation with quadratic terms and nonlinear simplex optimization, followed by a local registration using a cubic B-spline method with fast localized optimization. The corresponding coronary arteries among the available phases are identified using a recursive coronary segment matching method. Each of the identified vessel segments is transformed by the curved planar reformation (CPR) method. Four features are extracted from each corresponding segment as quality indicators in the original computed tomography volume and the straightened CPR volume, and each quality indicator is used as a voting classifier for the arterial segment. A weighted voting ensemble (WVE) classifier is designed to combine the votes of the four voting classifiers for each corresponding segment. The segment with the highest WVE vote is then selected as the best-quality segment. In this study, the training and test sets consisted of 6 and 20 cCTA cases, respectively, each with 6 phases, containing a total of 156 cCTA volumes and 312 coronary artery trees. An observer preference study was also conducted with one expert cardiothoracic radiologist and four nonradiologist readers to visually rank vessel segment quality. The performance of our automated method was evaluated by comparing the automatically identified best-quality segments identified by the computer to those selected by the observers. Results: For the 20 test cases, 254 groups of corresponding vessel segments were identified after multiple phase registration and recursive matching. The AI-BQ segments agreed with the radiologist’s top 2 ranked segments in 78.3% of the 254 groups (Cohen’s kappa 0.60), and with the 4 nonradiologist observers in 76.8%, 84.3%, 83.9%, and 85.8% of the 254 groups. In addition, 89.4% of the AI-BQ segments agreed with at least two observers’ top 2 rankings, and 96.5% agreed with at least one observer’s top 2 rankings. In comparison, agreement between the four observers’ top ranked segment and the radiologist’s top 2 ranked segments were 79.9%, 80.7%, 82.3%, and 76.8%, respectively, with kappa values ranging from 0.56 to 0.68. Conclusions: The performance of our automated method for selecting the best-quality coronary segments from a multiple-phase cCTA acquisition was comparable to the selection made by human observers. This study demonstrates the potential usefulness of the automated method in clinical practice, enabling interpreting physicians to fully utilize the best available information in cCTA for diagnosis of coronary disease, without requiring manual search through the multiple phases and minimizing the variability in image phase selection for evaluation of coronary artery segments across the diversity of human readers with variations in expertise.

61 RADIATION PROTECTION AND DOSIMETRY↗

Computerized analysis of coronary artery disease: Performance evaluation of segmentation and tracking of coronary arteries in CT angiograms

Purpose: The authors are developing a computer-aided detection system to assist radiologists in analysis of coronary artery disease in coronary CT angiograms (cCTA). This study evaluated the accuracy of the authors’ coronary artery segmentation and tracking method which are the essential steps to define the search space for the detection of atherosclerotic plaques. Methods: The heart region in cCTA is segmented and the vascular structures are enhanced using the authors’ multiscale coronary artery response (MSCAR) method that performed 3D multiscale filtering and analysis of the eigenvalues of Hessian matrices. Starting from seed points at the origins of the left and right coronary arteries, a 3D rolling balloon region growing (RBG) method that adapts to the local vessel size segmented and tracked each of the coronary arteries and identifies the branches along the tracked vessels. The branches are queued and subsequently tracked until the queue is exhausted. With Institutional Review Board approval, 62 cCTA were collected retrospectively from the authors’ patient files. Three experienced cardiothoracic radiologists manually tracked and marked center points of the coronary arteries as reference standard following the 17-segment model that includes clinically significant coronary arteries. Two radiologists visually examined the computer-segmented vessels and marked the mistakenly tracked veins and noisy structures as false positives (FPs). For the 62 cases, the radiologists marked a total of 10191 center points on 865 visible coronary artery segments. Results: The computer-segmented vessels overlapped with 83.6% (8520/10191) of the center points. Relative to the 865 radiologist-marked segments, the sensitivity reached 91.9% (795/865) if a true positive is defined as a computer-segmented vessel that overlapped with at least 10% of the reference center points marked on the segment. When the overlap threshold is increased to 50% and 100%, the sensitivities were 86.2% and 53.4%, respectively. For the 62 test cases, a total of 55 FPs were identified by radiologist in 23 of the cases. Conclusions: The authors’ MSCAR-RBG method achieved high sensitivity for coronary artery segmentation and tracking. Studies are underway to further improve the accuracy for the arterial segments affected by motion artifacts, severe calcified and noncalcified soft plaques, and to reduce the false tracking of the veins and other noisy structures. Methods are also being developed to detect coronary artery disease along the tracked vessels.

60 APPLIED LIFE SCIENCES↗

Evaluation of Coronary Artery Disease and Coronary Anomalies with a Handheld Smartphone

The purpose of this study was to determine the diagnostic accuracy of an iPhone for evaluation of the coronary arteries on coronary CT angiography (CTA) in comparison to a standard clinical workstation. Fifty coronary CTA exams were selected to include a range of normal and abnormal cases including both coronary artery disease (CAD) of varying severity and coronary artery anomalies. Two cardiac radiologists reviewed each exam on a standard clinical workstation initially and then on an iPhone 6 after a washout period. Coronary stenosis was evaluated on a 4-point scale and presence of coronary anomalies was recorded. Two additional cardiac radiologists reviewed all cases in consensus on the standard workstation and these results were used as the reference standard. When reader results were compared to the reference standard, there was no significant difference in agreement for per-vessel stenosis scores using either the iPhone or standard clinical workstation. The intraobserver intertechnology agreement on a per-vessel basis for obstructive CAD were 97.4% (299/307, kappa = 0.777) and 97.5% (317/325, kappa = 0.804) for the two readers. All cases of coronary anomalies were identified by both readers regardless of the device used. Coronary CTA examinations can be interpreted on a smartphone with diagnostic accuracy comparable to a standard workstation. 3D visualization app on the iPhone may facilitate urgent coronary CTA review when a workstation is not available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Coronary Heart Disease Screening in Asymptomatic Hodgkin Lymphoma Patients Using Coronary Computed Tomography Angiography: Results and Risk Factor Analysis

Purpose: To prospectively investigate the coronary artery status using coronary CT angiography (CCTA) in patients with Hodgkin lymphoma treated with combined modalities and mediastinal irradiation. Methods and Materials: All consecutive asymptomatic patients with Hodgkin lymphoma entered the study during follow-up, from August 2007 to May 2012. Coronary CT angiography was performed, and risk factors were recorded along with leukocyte telomere length (LTL) measurements. Results: One hundred seventy-nine patients entered the 5-year study. The median follow-up was 11.6 years (range, 2.1-40.2 years), and the median interval between treatment and the CCTA was 9.5 years (range, 0.5-40 years). Coronary artery abnormalities were demonstrated in 46 patients (26%). Coronary CT angiography abnormalities were detected in nearly 15% of the patients within the first 5 years after treatment. A significant increase (34%) occurred 10 years after treatment (P=.05). Stenoses were mostly nonostial. Severe stenoses were observed in 12 (6.7%) of the patients, entailing surgery with either angioplasty with stent placement or bypass grafting in 10 of them (5.5%). A multivariate analysis demonstrated that age at treatment, hypertension, and hypercholesterolemia, as well as radiation dose to the coronary artery origins, were prognostic factors. In the group of patients with LTL measurements, hypertension and LTL were the only independent risk factors. Conclusions: The findings suggest that CCTA can identify asymptomatic individuals at risk of acute coronary artery disease who might require either preventive or curative measures. Conventional risk factors and the radiation dose to coronary artery origins were independent prognostic factors. The prognostic value of LTL needs further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dependence of Coronary 3-Dimensional Dose Maps on Coronary Topologies and Beam Set in Breast Radiation Therapy: A Study Based on CT Angiographies

Purpose: In left-side breast radiation therapy (RT), doses to the left main (LM) and left anterior descending (LAD) coronary arteries are usually assessed after delineation by prior anatomic knowledge on the treatment planning computed tomography (CT) scan. In this study, dose sensitivity due to interindividual coronary topology variation was assessed, and hot spots were located. Methods and Materials: Twenty-two detailed heart models, created from heart computed tomography angiographies, were fitted into a single representative female thorax. Two breast RT protocols were then simulated into a treatment planning system: the first protocol comprised tangential and tumoral bed beams (TGs{sub T}B) at 50 + 16 Gy, the second protocol added internal mammary chain beams at 50 Gy to TGs{sub T}B (TGs{sub T}B{sub I}MC). For the heart, the LAD, and the LM, several dose indicators were calculated: dose-volume histograms, mean dose (D{sub mean}), minimal dose received by the most irradiated 2% of the volume (D{sub 2%}), and 3-dimensional (3D) dose maps. Variations of these indicators with anatomies were studied. Results: For the LM, the intermodel dispersion of D{sub mean} and D{sub 2%} was 10% and 11%, respectively, with TGs{sub T}B and 40% and 80%, respectively, with TGs{sub T}B{sub I}MC. For the LAD, these dispersions were 19% (D{sub mean}) and 49% (D{sub 2%}) with TGs{sub T}B and 35% (D{sub mean}) and 76% (D{sub 2%}) with TGs{sub T}B{sub I}MC. The 3D dose maps revealed that the internal mammary chain beams induced hot spots between 20 and 30 Gy on the LM and the proximal LAD for some coronary topologies. Without IMC beams, hot spots between 5 and 26 Gy are located on the middle and distal LAD. Conclusions: Coronary dose distributions with hot spot location and dose level can change significantly depending on coronary topology, as highlighted by 3D coronary dose maps. In clinical practice, coronary imaging may be required for a relevant coronary dose assessment, especially in cases of internal mammary chain irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Corrected coronary opacification decrease from coronary computed tomography angiography: Validation with quantitative 13N-ammonia positron emission tomography

Background: To assess the functional relevance of a coronary artery stenosis, corrected coronary opacification (CCO) decrease derived from coronary computed tomography angiography (CCTA) has been proposed. The present study aims at validating CCO decrease with quantitative 13N-ammonia positron emission tomography (PET) myocardial perfusion imaging (MPI). Methods and Results: This retrospective study consists of 39 patients who underwent hybrid CCTA/PET-MPI. From CCTA, attenuation in the coronary lumen was measured before and after a stenosis and corrected to the aorta to calculate CCO and its decrease. Relative flow reserve (RFR) was calculated by dividing the stress myocardial blood flow (MBF) of a vessel territory subtended by a stenotic coronary by the stress MBF of the reference territories without stenoses. RFR was abnormal in 11 vessel territories (27%). CCO decrease yielded a sensitivity, specificity, negative predictive value, positive predictive value, and accuracy for prediction of an abnormal RFR of 73%, 70%, 88%, 47%, and 70%, respectively. Conclusions: CCTA-derived CCO decrease has moderate diagnostic accuracy to predict an abnormal RFR in PET-MPI. However, its high negative predictive value to rule out functional relevance of a given lesion may confer clinical implications in the diagnostic work-up of patients with a coronary stenosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Coronary vascular age: An alternate means for predicting stress-induced myocardial ischemia in patients with suspected coronary artery disease

Background: Coronary artery calcium (CAC) can be used to estimate vascular age in adults, providing a convenient transformation of CAC from Agatston units into a year’s scale. We investigated the role of coronary vascular age in predicting stress-induced myocardial ischemia in subjects with suspected coronary artery disease (CAD). Methods: A total of 717 subjects referred to CAC scoring and {sup 82}Rb PET/CT stress-rest myocardial perfusion imaging for suspected CAD were studied. CAC score was measured according to the Agatston method and coronary vascular age by equating estimated CAD risk for chronological age and CAC using the formula 39.1 + 7.25 × ln(CAC + 1). Results: Stress-induced ischemia was present in 105 (15%) patients. Mean chronological age, CAC score, and coronary vascular age were higher (all P < .001) in patients with ischemia compared to those without. At incremental analysis, the global Chi square increased from 41.26 to 68.77 (P < .001) when chronological age was added to clinical variables. Including vascular age in the model, the global Chi square further increased from 68.77 to 106.38 (P < .001). Adding chronological age to clinical data, continuous net reclassification improvement (cNRI) was 0.57, while adding vascular age to clinical data and chronological age cNRI was 0.62. At decision curve analysis, the model including vascular age was associated with the highest net benefit compared to the model including only clinical data, to the model including chronological age and clinical data, and to a strategy considering that all patients had ischemia. The model including vascular age also showed the largest reduction in false-positive rate without missing any ischemic patients. Conclusions: In subjects with suspected CAD, coronary vascular age is strongly associated with stress-induced ischemia. The communication of a given vascular age would have a superior emotive impact improving observance of therapies and healthier lifestyles.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-H-CAMPUS-IeP2-03: Development of 3D Printed Coronary Phantoms for In-Vitro CT-FFR Validation Using Data from 320- Detector Row Coronary CT Angiography

Purpose: To validate Computed Tomography Fractional Flow Reserve (CT-FFR) measurements with accurate 3D printed coronary phantoms. Methods: DICOM data from four phases in two patients imaged with a standard 320 × 0.5mm coronary CT acquisition (70–80% cardiac cycle) underwent semi-automated segmentation using a research workstation. Both patients had a >50% stenosis from the clinical image interpretation. Each volume was saved as a Stereo Lithographic (STL) file with 250 micron resolution. The 3D geometries were qualitatively assessed; the best of the four phases was 3D printed using a Stratasys Eden260V printer in Tango+, a rubber-like material that roughly emulates mechanical properties of human vasculature. We connected the model to a programmable pump and measured the pressure drop using pressure sensors embedded proximal and distal to the arterial stenosis. Next, the STL files used for the 3D printed models were uploaded in the ANSYS meshing tool (ICEM CFD 16.1). A standard meshing process was applied and the meshed geometry was directly imported in the ANSYS Fluent for Computational Flow Dynamics simulations. The CFD simulations were used to calculate the CT-FFR and compared to the bench top FFR measured in the 3D printed phantoms. Results: FFR-CT measurements and phantoms were completed in within an hour after the segmentation. Patient 1 had a 60% stenosis that resulted in a CT-FFR of 0.68. The second case had a 50% stenosis and a CT-FFR of 0.75. The average bench top FFR measurements were 0.72 and 0.80, respectively. Conclusion: This pilot investigation demonstrated the use of a bench-top coronary model for CT-FFR validation. The measurements and the CFD simulations agreed within 6%. Project supported by Support: Toshiba America Medical Systems Corp.and NIH grant R01-EB002873. Project supported by Toshiba America Medical Systems Corp.and partial support from NIH grant R01-EB002873.

60 APPLIED LIFE SCIENCES↗

Coronary calcium score influences referral for invasive coronary angiography after normal myocardial perfusion SPECT

Background: In patients with normal SPECT but persistent complaints, invasive angiography may exclude obstructive coronary disease. We assessed whether high coronary artery calcium (CAC) scores are associated with increased referral for invasive angiography following normal SPECT. Methods and results: 2286 consecutive patients (mean age 60 ± 12, 39% male) with normal SPECT were assessed. All patients underwent simultaneous CAC scoring. Patients were categorized into four groups based on their CAC score: CAC = 0 (n = 694), CAC 1 to 100 (n = 891), CAC 101 to 400 (n = 368), and CAC >400 (n = 333). The decision to perform angiography was left to the discretion of treating physician. Follow-up angiography was confined to the first 60 days after SPECT. Occurrence of MACE (late revascularization, myocardial infarction or death) was recorded. Overall, 100 patients (4.4%) underwent early angiography with increasing rates in higher CAC score groups (1.0%, 2.6%, 8.4%, and 11.7%), respectively, P < .001). A CAC score >400 (OR 3.56, 95% CI 2.19 to 5.77, P < .001) was independently associated with referral to angiography. Similarly, CAC score >400 was an independent predictor for MACE (HR 9.26, 95% CI 5.06 to 16.93). Early angiography did not influence prognosis (HR 1.57, 95% CI 0.91 to 2.73). Conclusions: CAC scoring impacts clinical decision-making and increases referral rates for invasive angiography after normal SPECT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic coronary calcium scoring using noncontrast and contrast CT images

Purpose: Calcium scoring is widely used to assess the risk of coronary heart disease (CHD). Accurate coronary artery calcification detection in noncontrast CT image is a prerequisite step for coronary calcium scoring. Currently, calcified lesions in the coronary arteries are manually identified by radiologists in clinical practice. Thus, in this paper, a fully automatic calcium scoring method was developed to alleviate the work load of the radiologists or cardiologists. Methods: The challenge of automatic coronary calcification detection is to discriminate the calcification in the coronary arteries from the calcification in the other tissues. Since the anatomy of coronary arteries is difficult to be observed in the noncontrast CT images, the contrast CT image of the same patient is used to extract the regions of the aorta, heart, and coronary arteries. Then, a patient-specific region-of-interest (ROI) is generated in the noncontrast CT image according to the segmentation results in the contrast CT image. This patient-specific ROI focuses on the regions in the neighborhood of coronary arteries for calcification detection, which can eliminate the calcifications in the surrounding tissues. A support vector machine classifier is applied finally to refine the results by removing possible image noise. Furthermore, the calcified lesions in the noncontrast images belonging to the different main coronary arteries are identified automatically using the labeling results of the extracted coronary arteries. Results: Forty datasets from four different CT machine vendors were used to evaluate their algorithm, which were provided by the MICCAI 2014 Coronary Calcium Scoring (orCaScore) Challenge. The sensitivity and positive predictive value for the volume of detected calcifications are 0.989 and 0.948. Only one patient out of 40 patients had been assigned to the wrong risk category defined according to Agatston scores (0, 1–100, 101–300, >300) by comparing with the ground truth. Conclusions: The calcified lesions in the noncontrast CT images can be detected automatically by using the segmentation results of the aorta, heart, and coronary arteries obtained in the contrast CT images with a very high accuracy.

60 APPLIED LIFE SCIENCES↗

Emerging Role of Coronary Computed Tomography Angiography in Lipid-Lowering Therapy: a Bridge to Image-Guided Personalized Medicine

Purpose of Review: To summarize the current status of coronary computed tomography angiography (CTA) in the assessment of coronary plaques and discuss the ability of serial coronary CTA to quantitatively measure changes in the plaque burden in response to lipid-lowering therapy. Recent Findings: Recent advances in coronary CTA have allowed identification of high-risk coronary features in acute coronary syndrome and measurement of changes in the coronary plaque burden with good reproducibility. Statin therapy may delay plaque progression and change some plaque features. However, the clinical relevance of quantitative changes in coronary plaques and the optimal methods to reduce the plaque burden remain unclear. Summary: Despite guideline-directed lipid-lowering therapy, adverse events still occur in substantial numbers of patients receiving statins. Coronary CTA is noninvasive and has high diagnostic performance in patients with coronary artery disease, making change in the plaque burden an applicable biomarker for individualized assessment of future risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relation between quantitative coronary CTA and myocardial ischemia by adenosine stress myocardial CT perfusion

Background: Coronary-computed tomography angiography (CTA) has limited accuracy to predict myocardial ischemia. Besides luminal area stenosis, other coronary plaque morphology and composition parameters may help to assess ischemia. With the integration of coronary CTA and adenosine stress CT myocardial perfusion (CTP), reliable information regarding coronary anatomy and function can be derived in one procedure. This analysis aimed to investigate the association between coronary stenosis severity, plaque composition and morphology and the presence of ischemia measured with adenosine stress myocardial CTP. Methods and Results: 84 patients (age, 62 ± 10 years; 48% men) who underwent sequential coronary CTA and adenosine stress myocardial CT perfusion were analyzed. Automated quantification was performed in all coronary lesions (quantitative CTA). Downstream myocardial ischemia was assessed by visual analysis of the rest and stress CTP images and defined as a summed difference score of ≥1. One or more coronary plaques were present in 146 coronary arteries of which 31 (21%) were ischemia-related. Of the lesions with a stenosis percentage <50%, 50%-70%, and >70%, respectively, 9% (6/67), 18% (9/51), and 57% (16/28) demonstrated downstream ischemia. Furthermore, mean plaque burden, plaque volume, lesion length, maximal plaque thickness, and dense calcium volume were significantly higher in ischemia-related lesions, but only stenosis severity (%) (OR 1.06; 95% CI 1.02-1.10; P = .006) and lesion length (mm) (OR 1.26; 95% CI 1.02-1.55; P = .029) were independent correlates. Conclusions: Increasing stenosis percentage by quantitative CTA is positively correlated to myocardial ischemia measured with adenosine stress myocardial CTP. However, stenosis percentage remains a moderate determinant. Lumen area stenosis and lesion length were independently associated with ischemia, adjusted for coronary plaque volume, mean plaque burden, maximal lesion thickness, and dense calcium volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Distinct expression patterns of Flk1 and Flt1 in the coronary vascular system during development and after myocardial infarction

Highlights: • Flk1 is expressed in ECs with an epicardial-to-endocardial transmural gradient. • Flt1 is homogeneously expressed in ECs in neonatal and adult mouse hearts. • Flk1 is transiently induced but Flt1 is maintained in coronary vessels after MI. • The kinetics of Flk1 and Flt1 after MI recapitulates that in cardiac development. The coronary vascular system is critical for myocardial growth and cardiomyocyte survival. However, the molecular mechanism regulating coronary angiogenesis remains elusive. Vascular endothelial growth factor (VEGF) regulates angiogenesis by binding to the specific receptors Flk1 and Flt1, which results in different functions. Despite the importance of Flk1 and Flt1, their expression in the coronary vasculature remains largely unknown due to the lack of appropriate antibodies for immunostaining. Here, we analyzed multiple reporter mice including Flk1-GFP BAC transgenic (Tg), Flk1-LacZ knock-in, Flt1-DsRed BAC Tg, and Flk1-GFP/Flt1-DsRed double Tg animals to determine expression patterns in mouse hearts during cardiac growth and after myocardial infarction (MI). We found that Flk1 was expressed in endothelial cells (ECs) with a pattern of epicardial-to-endocardial transmural gradients in the neonatal mouse ventricle, which was downregulated in adult coronary vessels with development. In contrast, Flt1 was homogeneously expressed in the ECs of neonatal mouse hearts and expression was maintained until adulthood. After MI, expression of both Flk1 and Flt1 was induced in the regenerating coronary vessels at day 7. Intriguingly, Flk1 expression was downregulated thereafter, whereas Flt1 expression was maintained in the newly formed coronary vessels until 30 days post-MI, recapitulating their expression kinetics during development. This is the first report demonstrating the spatiotemporal expression patterns of Flk1 and Flt1 in the coronary vascular system during development and after MI; thus, this study suggests that these factors have distinct and important functions in coronary angiogenesis.

60 APPLIED LIFE SCIENCES↗

Personalized and uncertainty-aware coronary hemodynamics simulations: From Bayesian estimation to improved multi-fidelity uncertainty quantification

Non-invasive simulations of coronary hemodynamics have improved clinical risk stratification and treatment outcomes for coronary artery disease, compared to relying on anatomical imaging alone. However, simulations typically use empirical approaches to distribute total coronary flow amongst the arteries in the coronary tree, which ignores patient variability, the presence of disease, and other clinical factors. Further, uncertainty in the clinical data often remains unaccounted for in the modeling pipeline. We present an end-to-end uncertainty-aware pipeline to (1) personalize coronary flow simulations by incorporating vessel-specific coronary flows as well as cardiac function; and (2) predict clinical and biomechanical quantities of interest with improved precision, while accounting for uncertainty in the clinical data. We assimilate patient-specific measurements of myocardial blood flow from clinical CT myocardial perfusion imaging to estimate branch-specific coronary artery flows. Simulated noise in the clinical data is used to estimate the joint posterior distributions of the model parameters using adaptive Markov Chain Monte Carlo sampling. Additionally, the posterior predictive distribution for the relevant quantities of interest is determined using a new approach combining multi-fidelity Monte Carlo estimation with non-linear, data-driven dimensionality reduction. This leads to improved correlations between high- and low-fidelity model outputs. Our framework accurately recapitulates clinically measured cardiac function as well as branch-specific coronary flows under measurement noise uncertainty. We observe substantial reductions in confidence intervals for estimated quantities of interest compared to single-fidelity Monte Carlo estimation and state-of-the-art multi-fidelity Monte Carlo methods. This holds especially true for quantities of interest that showed limited correlation between the low- and high-fidelity model predictions. In addition, the proposed multi-fidelity Monte Carlo estimators are significantly cheaper to compute than traditional estimators, under a specified confidence level or variance. The proposed pipeline for personalized and uncertainty-aware predictions of coronary hemodynamics is based on routine clinical measurements and recently developed techniques for CT myocardial perfusion imaging. The proposed pipeline offers significant improvements in precision and reduction in computational cost.

Bayesian parameter estimation↗

Diagnostic value of stress thallium-201/rest technetium-99m-sestamibi sequential dual isotope high-speed myocardial perfusion imaging for the detection of haemodynamically relevant coronary artery stenosis

Background: The aim of this study was to determine the diagnostic accuracy of stress thallium-201/rest technetium-99m-sestamibi sequential dual-isotope high-speed myocardial perfusion imaging (DI-HS-MPI) against invasively determined fractional flow reserve (FFR). Methods: Fifty-four consecutive patients prospectively underwent DI-HS-MPI before invasive coronary angiography. Perfusion was scored visually by summed stress score on a patient and coronary territory basis. Significant coronary artery disease (CAD) was defined by the presence of ≥ 90% stenosis/occlusion or fractional flow reserve ≤ 0.80 for coronary stenosis ≥ 50%. Results: FFR was measured in 69 of 162 coronary vessels, with 1.28 ± 0.56 vessels assessed/patient. Sensitivity, specificity, and diagnostic accuracy of MPI for the detection of significant CAD were 92.8%, 69.2%, and 81.4%, on a patient basis, and 83.7%, 90.4%, and 88.8% by coronary territory. Conclusions: DI-HS-MPI accurately detects functionally significant CAD as defined by using FFR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗