Metal-binding amino acid ligands commonly found in metalloproteins differentially fractionate copper isotopes
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
An experimental study is described to measure the isotopic enrichment of boron. Xenon ions from 100 eV to 1.5 keV were used to sputter a boron nitride target. An ion gun was used to generate the ion beam. The ion current density at the target surface was approximately 30 microA/sq cm. Xenon ions impinged on the target surface at 50 deg angle to the surface normal. Since boron nitride is an insulator, a flood electron gun was used in our experiments to neutralize the positive charge buildup on the target surface. The sputtered secondary ions of boron were detected by a quadrupole mass spectrometer. The spectrometer entrance aperture was located perpendicular to the ion beam direction and 10 mm away from the target surface. The secondary ion flux was observed to be enriched in the heavy isotopes at lower ion energies. The proportion of heavy isotopes in the sputtered secondary ion flux was found to decrease with increasing primary ion energy from 100 to 350 eV. Beyond 350 eV, light isotopes were sputtered preferentially. The light isotope enrichment factor was observed to reach an asymptotic value of 1.27 at 1.5 keV. This trend is similar to that of the isotopic enrichment observed earlier when copper was sputtered with xenon ions in the same energy range.
Sputtering of boron nitride with xenon ions was investigated using secondary ion (SIMS) and secondary neutral (SNMS) mass spectrometry. The ions generated from the ion gun were incident on the target at an angle of 50' with respect to the surface'normal. The energy of ions ranged from 100 eV to 3 keV. A flood electron gun was used to neutralize the positive charge build-up on the target surface. The intensities of sputtered neutral and charged particles, including single atoms, molecules, and clusters, were measured as a function of ion energy. Positive SIMS spectra were dominated by the two boron isotopes whereas BN- and B- were the two major constituents of the negative SIMS spectra. Nitrogen could be detected only in the SNMS spectra. The intensity-energy curves of the sputtered particles were similar in shape. The knees in P-SIMS and SNMS intensity-energy curves appear at around I keV which is significantly higher that 100 to 200 eV energy range at which knees appear in the sputtering of medium and heavy elements by ions of argon and xenon. This difference in the position of the sputter yield knee between boron nitride and heavier targets is due to the reduced ion energy differences. The isotopic composition of secondary ions of boron were measured by bombarding boron nitride with xenon ions at energies ranging from 100 eV to 1.5 keV using a quadrupole mass spectrometer. An ion gun was used to generate the ion beam. A flood electron gun was used to neutralize the positive charge buildup on the target surface. The secondary ion flux was found to be enriched in heavy isotopes at lower incident ion energies. The heavy isotope enrichment was observed to decrease with increasing primary ion energy. Beyond 350 eV, light isotopes were sputtered preferentially with the enrichment increasing to an asymptotic value of 1.27 at 1.5 keV. The trend is similar to that of the isotopic enrichment observed earlier when copper was sputtered with xenon ions in the same energy range.
An experimental study is described to measure low-energy (less than 600 eV) sputtering yields of molybdenum with xenon ions using Rutherford backscattering spectroscopy (RBS) and secondary neutral mass spectroscopy (SNMS). An ion gun was used to generate the ion beam. The ion current density at the target surface was approximately 30 (micro)A/sq cm. For RBS measurements, the sputtered material was collected on a thin aluminum strip which was mounted on a semi-circular collector plate. The target was bombarded with 200 and 500 eV xenon ions at normal incidence. The differential sputtering yields were measured using the RBS method with 1 MeV helium ions. The differential yields were fitted with a cosine fitting function and integrated with respect to the solid angle to provide the total sputtering yields. The sputtering yields obtained using the RBS method are in reasonable agreement with those measured by other researchers using different techniques. For the SNMS measurements, 150 to 600 eV xenon ions were used at 50deg angle of incidence. The SNMS spectra were converted to sputtering yields for perpendicular incidence by normalizing SNMS spectral data at 500 eV with the yield measured by Rutherford backscattering spectrometry. Sputtering yields as well as the shape of the yield-energy curve obtained in this manner are in reasonable agreement with those measured by other researchers using different techniques. Sputtering yields calculated by using two semi-spherical formulations agree reasonably well with measured data. The isotopic composition of secondary ions were measured by bombarding copper with xenon ions at energies ranging from 100 eV to 1.5 keV. The secondary ion flux was found to be enriched in heavy isotopes at low incident ion energies. The heavy isotope enrichment was observed to decrease with increasing impact energy. Beyond 700 eV, light isotopes were sputtered preferentially with the enrichment remaining nearly constant.
Secondary ion mass spectrometry was used to study oxygen implanted in the surface of copper from the Long Duration Exposure Facility (LDEF). Oxidation that occurred in orbit shows a characteristic oxygen isotope composition, depleted in O-18. The measured depletion is comparable to the predicted depletion (45 percent) based on a model of the gravitational separation of the oxygen isotopes. The anomalous oxygen was contained within 10nm of the surface. Tray E10 was calculated to have received 5.14 x 10(exp 21) atoms of oxygen cm(sup -2) during the LDEF mission and so there is sufficient anomalous implanted oxygen present in the surface to obtain a reliable isotopic profile.
The fragmentation of target nuclei by relativistic protons and heavy ions is described within the context of a simple abrasion-ablation-final-state interaction model. Abrasion is described by a quantum mechanical formalism utilizing an optical model potential approximation. Nuclear charge distributions of the excited prefragments are calculated by both a hypergeometric distribution and a method based upon the zero-point oscillations of the giant dipole resonance. Excitation energies are estimated from the excess surface energy resulting from the abrasion process and the additional energy deposited by frictional spectator interactions of the abraded nucleons. The ablation probabilities are obtained from the EVA-3 computer program. Isotope production cross sections for the spallation of copper targets by relativistic protons and for the fragmenting of carbon targets by relativistic carbon, neon, and iron projectiles are calculated and compared with available experimental data.
As the core of a massive star collapses to form a neutron star, the flux of neutrinos in the overlying shells of heavy elements becomes so great that, despite the small cross section, substantial nuclear transmutation is induced. Neutrinos excite heavy elements and even helium to particle unbound levels. The evaporation of a single neutron or proton, and the back reaction of these nucleons on other species present, significantly alters the outcome of traditional nucleosynthesis calculations leading to a new process: nu-nucleosynthesis. Modifications to traditional hydrostatic and explosive varieties of helium, carbon, neon, oxygen, and silicon burning are considered. The results show that a large number of rare isotopes, including many of the odd-Z nuclei from boron through copper, owe much of their present abundance in nature to this process.
Depth profiles of O-16 and O-18/O-16 were measured on stainless steel nuts and copper sheet (from a grounding strap) recovered from the leading edge of LDEF (Tray E10). The measurements were obtained by dynamic SIMS (secondary ion mass spectrometry) using a VG Isolab 54 ion microprobe. Plots of O-18/O-16 against time, show large depletions of up to a factor of 2 compared to the O-18/O-16 value at sea level. The O-16 current decreases by 2 orders of magnitude in the interior of the metal, and the corresponding profile of anomalous O-16 is strongly peaked in the outer few tens of nanometers of the surface. This depth scale is a tentative one based on estimated sputtering rates. Plots of O-18/O-16 against 1/O-16 should be linear if two isotopically distinct components, one of variable concentration (orbital component) and one of fixed concentration (normal oxygen), are mixed. Data to be presented at the meeting show departures from linearity which result from variability in the concentration of normal oxygen, but may also arise from the implantation of oxygen with a range of fractionation due to the decaying orbit of the LDEF, sputtering of the surface by atomic oxygen, and the different momenta of the two isotopes due to their equal velocities. The potential for using this method as a means of identifying exposure to low-Earth orbit, de-convoluting the effects of space exposure from terrestrial contamination, and using the implanted anomolous oxygen as a means of studying the atomic oxygen density and upper atmosphere temperature height profile will be discussed at the meeting.
The objectives of this experiment are to collect and isotopically analyze interstellar gas atoms around the orbit of the Earth for the purpose of obtaining new data relevant to understanding nucleosynthesis, and to study the dynamics of the interstellar wind inside the heliosphere and the isotopic composition of the interstellar medium outside the heliosphere. The experiment hardware will act as a set of simple cameras with high-purity copper-beryllium collecting foils serving as the film. The experiment housing will mount and thermally control the foils, establish the viewing angles and viewing direction, provide baffling to reject ambient neutral particles, provide a voltage grid to reject ionospheric charged particles, sequence collecting foils, control exposure times, and protect the foils from contamination during the deployment and retrieval of the LDEF. After being returned to Earth, the entrapped atoms can be analyzed by mass spectroscopy to determine the relative abundance of the different isotopes of helium and neon. An attempt will also be made to detect argon.
The Interstellar Gas Experiment (IGE) is designed to collect particles of the interstellar gas - a wind of interstellar media particles moving in the vicinity of the solar system. These particles will be returned to earth where the isotopic ratios of the noble gases among these particles will be measured. IGE was designed and programmed to expose 7 sets of six copper-beryllium metallic collecting foils to the flux of neutral interstellar gas particles which penetrate the heliosphere to the vicinity of the earth's orbit. These particles are trapped in the collecting foils and will be returned to earth for mass-spectrographic analysis when Long Duration Exposure Facility (LDEF) on which IGE was launched, is recovered.
Work done in several areas to advance the state of the art of magnetic mass spectrometers is described. The calculations and data necessary for the design of inhomogeneous field mass spectrometers, and the calculation of ion trajectories through such fields are presented. The development and testing of solid state ion detection devices providing the capability of counting single ions is discussed. New techniques in the preparation and operation of thermal-ionization ion sources are described. Data obtained on the concentrations of copper in rainfall and uranium in air samples using the improved thermal ionization techniques are presented. The design of a closed system static mass spectrometer for isotopic analyses is discussed. A summary of instrumental aspects of a four-stage mass spectrometer comprising two electrostatic and two 90 deg. magnetic lenses with a 122-cm radius used to study the interaction of ions with solids is presented.
The mineralogy and isotopic composition of sulfur found in hydrothermal deposits associated with five groups of vents along the ridge axis of the East Pacific Rise near 21 deg N latitude are investigated. Solid samples of mixed sulfides and sulfates from mounds, chimneys and the surrounding sediment as well as fresh basaltic glass were examined with a portable X-ray fluorescence spectrometer and by scanning electron microscopy, X-ray diffractometry, and electron microprobe analysis. For the three vents of exit temperature close to 350 C, the chimneys are found to be rich in copper sulfides, while for those of temperatures around 300 C, zinc sulfide is found to predominate. The major sulfides found in the chimneys include wurtzite, chalcopyrite, pyrite and cubanite, with anhydrite the dominant sulfate. Significant mineralogical differences are found between active and inactive vents. The isotopic composition of sulfur in anhydrites from active vents is observed to be close to that of sea water and consistent with a derivation from sea water sulfate. The isotopic composition of sulfur in the sulfide minerals is explained in terms of precipitation from solutions with reduced sulfur derived from basalts or basaltic magmas, and sea water sulfate. Finally, the deposits are interpreted as the results of the mixing of H2S-dominated hydrothermal fluids with cold sea water near the sea floor.
Ge-70 and Ge-74 isotopes were successfully separated from natural Ge, and were zone purified. Several highly enriched, high purity Ge-70 and Ge-74 single crystals were grown by the vertical Bridgman method. The growth system was designed for reliable growth of low dislocation density, high purity Ge single crystals of about 4 g weight. A Ge-70 and a Ge-74 crystal were selected for complete characterization. In spite of the large surface-to-volume ratio of these ingots, both Ge-70 and Ge-74 crystals contain low electrically active chemical net-impurity concentrations of about 2 x 10 exp 12/cu cm, which is 2 orders of magnitude better than that of Ge-74 crystals previously grown by two different groups. Isotopic enrichment of the Ge-70 and the Ge-74 crystals is 96.3 percent and 96.8 percent, respectively. The residual donors and acceptors present in both crystals were identified as phosphorus and copper, respectively. In addition, less than 10 exp 11/cu cm Ga, Al, and In were found in the Ge-70 crystal.
In 1975 the University of Alabama in Huntsville proposed an experiment for the Long Duration Exposure Facility (LDEF) designed to investigate the effects of the collision of the ambient orbital atmosphere, mainly consisting of atomic oxygen, with satellite surfaces travelling at about 8 km per second. In 1989, the potential for recovery of significant data from A0114 on a wide variety of materials was recognized and funding for three years of data analysis was appropriated. Some significant or unique findings from the experiment A0114 include: numerous measurements of oxidation rates of surfaces under fast O atom bombardment, including Si, Ge, GaAs, SiC, and optical quality metal films; measurement of the stable attitude of the LDEF spacecraft in orbit using the gas dynamics pinhole camera; description of the formation of thick oxide films on copper at 20 C with fast oxygen; measurement of erosion rates of Kapton and other polymers at space station lifetime atomic oxygen fluences (10(exp 22) atoms/sq cm); and measurement of the cosmogenic isotopes Be-7 on spacecraft surfaces.
High energy proton induced nuclear reaction products are examined using seven elements, namely: aluminum, silicon, nickel, copper, zirconium, tantalum, and tungsten. We detected activities due to Na-22 from Al, Co-56 and Co-57 from Ni, Co-58 from Cu, and Y-88 from Zr targets. No induced activity was observed in Si, Ta, and W, most probably due to the long cooling times. Only the Zr sample contained a weak Be-7 peak, although Ta and W were also located at the leading edge of the spacecraft. Gamma-rays of individual isotopes were measured using a high-resolution Ge(Li) solid state detector coupled to a 4096-multichannel analyzer. Activities were calculated for Co-56 (846 keV) and Co-57 (122 and 136 keV's) at the time of the entry of the spacecraft and found to be 0.014 +/- 0.005 c/s-g, 0.018 +/- 0.002 c/s-g, and 0.0024 +/- 0.0007 c/s-g, respectively.
High energy proton induced nuclear reaction products are examined using seven elements, namely, Aluminum, Silicon, Nickel, Copper, Zirconium, Tantalum, and Tungsten. The samples were in the form of plates, 2 x 2 x 1/8 inches. Activities due to Na-22 from Al, Co-56 and Co-57 from Ni, Co-58 from Cu, and Y-88 from Zr targets were detected. No induced activity was observed in Si, Ta, and W, most probably due to the long cooling times. Only the Zr sample contained a weak Be-7 peak, although Ta and W were also located at the leading edge of the spacecraft. Gamma-rays of individual isotopes were measured using high-resolution Ge(Li) solid state detector coupled to 4096-multichannel analyzer. Activities were calculated for Co-56 (846 keV) and Co-57 (122 and 136 keV's) at the time of the entry of the spacecraft and found to be 0.014 plus or minus 0.005 c/sec. g, 0.018 plus or minus 0.002 c/sec. g, and 0.0024 plus or minus 0.0007 c/sec. g, respectively.
Inductively coupled plasma-mass spectrometry (ICP-MS) is a highly sensitive technique sometimes used for the trace determination of silicon at a mass-to-charge (m/z) ratio of 28, the most abundant natural isotope of silicon. Unfortunately, ICP-MS is unable to differentiate between other sources of m/z 28 and false positive results for silicon will result when other sources of m/z 28 are present. Nitrogen was a major source of m/z 28 and contributes to the m/z 28 signal when hydrazine sample or nitric acid preservative is introduced into the plasma. Accordingly, this work was performed to develop a sample preparation step coupled with an ICP-MS analysis that minimized non-silicon sources of m/z 28. In the preparatory step of this method, the hydrazine sample was first decomposed predominately to nitrogen gas and water with copper-catalyzed hydrogen peroxide. In the analysis step, ICP-MS was used without nitric acid preservative in samples or standards. Glass, a potential source of silicon contamination, was also avoided where possible. The method was sensitive, accurate, and reliable for the determination of silicon in monopropellant grade hydrazine (MPH) in AF-E-332 elastomer leaching tests. Results for silicon in MPH were comparable to those reported in the literature for other studies.