Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COPPER DETECTORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Surface purity control during XMASS detector refurbishment

The XMASS project aims at detecting dark matter, pp and {sup 7}Be solar neutrinos, and neutrino less double beta decay using large volume of pure liquid xenon. The first physics target of the XMASS project is to detect dark matter with 835 kg liquid xenon. After the commissioning runs, XMASS detector was refurbished to minimize the background contribution mainly from PMT sealing material and we restarted data taking in November 2013. We report how we control surface purity, especially how we prevent radon daughter accumulation on the detector copper surface, during XMASS detector refurbishment. The result and future plan of XMASS are also reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of an ultra-low-background proportional counter for measuring {sup 37}Ar

An ultra-low-background proportional counter design has been developed at Pacific Northwest National Laboratory (PNNL) using clean materials, primarily electro-chemically-purified copper. This detector, along with an ultra-low-background counting system (ULBCS), was developed to complement a new shallow underground laboratory (30 meters water-equivalent) at PNNL. The ULBCS design includes passive neutron and gamma shielding, along with an active cosmic-veto system. This system provides a capability for making ultra-sensitive measurements to support applications like age-dating soil hydrocarbons with {sup 14}C/{sup 3}H, age-dating of groundwater with {sup 39}Ar, and soil-gas assay for {sup 37}Ar to support On-Site Inspection (OSI). On-Site Inspection is a key component of the verification regime for the Comprehensive Nuclear-Test-Ban Treaty (CTBT). Measurements of radionuclides created by an underground nuclear explosion are valuable signatures of a Treaty violation. For OSI, the 35-day half-life of {sup 37}Ar, produced from neutron interactions with calcium in soil, provides both high specific activity and sufficient time for inspection before decay limits sensitivity. This work describes the calibration techniques and analysis methods developed to enable quantitative measurements of {sup 37}Ar samples over a broad range of proportional counter operating pressures. These efforts, along with parallel work in progress on gas chemistry separation, are expected to provide a significant new capability for {sup 37}Ar soil gas background studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent production of the K{sup +}π{sup 0} system by K{sup +} mesons on copper nuclei in the OKA detector

In a sample of ∼5 × 10{sup 9} positive kaon collisions with copper nuclei, the events of coherent production of K{sup +}π{sup 0} pairs are selected, the contributions of the Coulomb and strong production mechanisms are discriminated, and the corresponding cross sections are determined. The phase shift difference between the Coulomb and strong amplitudes is obtained.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulations for Tracking Cosmogenic Activation in Germanium and Copper

High-purity germanium (HPGe) detectors housed in copper cryostats and shielding materials are used in measurements of the extraordinarily rare nuclear decay process, neutrinoless double-beta decay (0νββ), and for dark matter searches. Cosmogenic production of 68Ge and 60Co in the germanium and copper represent an irreducible background to these experiments as the subsequent decays of these isotopes can mimic the signals of interest. These radioactive isotopes can be removed by chemical and/or isotopic separation, but begin to grow-in to the material after separation until the material is moved deep underground. This work is motivated by the need to have a reliable, experimentally benchmarked simulation tool for evaluating shielding materials used during transportation and near-surface manufacturing of experiment components. The resulting simulations tool has been used to enhance the effectiveness of an existing transport shield used to ship enriched germanium from the separations facility to the detector manufacturing facility.

Aguayo, Estanislao↗

Controlling Low-Rate Signal Path Microdischarge for an Ultra-Low-Background Proportional Counter

ABSTRACT Pacific Northwest National Laboratory (PNNL) has developed an ultra-low-background proportional counter (ULBPC) made of high purity copper. These detectors are part of an ultra-low-background counting system (ULBCS) in the newly constructed shallow underground laboratory at PNNL (at a depth of ~30 meters water-equivalent). To control backgrounds, the current preamplifier electronics are located outside the ULBCS shielding. Thus the signal from the detector travels through ~1 meter of cable and is potentially susceptible to high voltage microdischarge and other sources of electronic noise. Based on initial successful tests, commercial cables and connectors were used for this critical signal path. Subsequent testing across different batches of commercial cables and connectors, however, showed unwanted (but still low) rates of microdischarge noise. To control this noise source, two approaches were pursued: first, to carefully validate cables, connectors, and other commercial components in this critical signal path, making modifications where necessary; second, to develop a custom low-noise, low-background preamplifier that can be integrated with the ULBPC and thus remove most commercial components from the critical signal path. This integrated preamplifier approach is based on the Amptek A250 low-noise charge-integrating preamplifier module. The initial microdischarge signals observed are presented and characterized according to the suspected source. Each of the approaches for mitigation is described, and the results from both are compared with each other and with the original performance seen with commercial cables and connectors.

low noise↗

Nuclear activation analysis of zirconium-90 isomeric and ground-state reactions at the OMEGA Laser Facility

Nuclear activation is a well-established technique for inferring neutron yields in laser direct-drive deuterium–tritium (DT) and deuterium–deuterium (D 2 ) implosions at the OMEGA Laser Facility. Zirconium has long been considered an excellent candidate for measuring DT neutron fusion yields by observing decays of the 90 Zr(n,2n) 89 Zr ground-state reaction. As it has a higher energy threshold than present activation detectors utilizing copper, zirconium provides a means to infer primary neutron yields that are less susceptible to being skewed due to neutron scattering within the experimental environment. However, with a 78.41-h half-life, it is not operationally practical to utilize this reaction for OMEGA experiments, which have a 1-h shot cycle. Zirconium’s 90 Zr(n,2n) 89 mZr reaction presents itself as a viable candidate to infer neutron yields within a shot cycle, given its half-life of 4.16 min. Here, we present an overview of the approach and methodology, utilizing first principles techniques, to infer the primary neutron yields from OMEGA DT fusion experiments by using both the isomeric and the ground-state reaction. Yields inferred from both reactions are compared, which are in good agreement between the two.

Activation analysis↗

Response of an implantable MOSFET dosimeter to {sup 192}Ir HDR radiation

New in vivo dosimetry methods would be useful for clinical HDR brachytherapy. An implantable MOSFET Dose Verification System designed by Sicel Technologies, Inc. was examined for use with {sup 192}Ir HDR applications. This investigation demonstrated that varying the dose rate from 22 to 84 cGy/min did not change detector response. The detectors exhibited a higher sensitivity to {sup 192}Ir energies than {sup 60}Co energies. A nonlinear accumulated dose effect was characterized by three third-order polynomials fit to data from detectors placed at three different distances from the source. The detectors were found to have minimal rotational angular dependence. A strong longitudinal angular dependence was found when the detector's copper coil and electronics assembly were aligned between the MOSFETs and incident radiation. This orientation showed a 16% decrease in response relative to other orientations tested.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Majorana Project

Working as part of a collaborative team, PNNL is bringing its signature capability in ultra-low-level detection to help search for a rare form of radioactive decay-never before detected-called "neutrinoless double beta decay" in germanium. If observed, it would demonstrate neutrinos are Majorana-type particles. This discovery would show neutrinos are unique among fundamental particles, having a property whereby the matter and anti-matter version of this particle are indistinguishable. Physicist John L. Orrell explains how they rely on the Shallow Underground Laboratory to conduct the research.

74 ATOMIC AND MOLECULAR PHYSICS↗

A preliminary investigation into the electrodeposition and synthesis of radiopure Copper–Chromium alloys for rare-event physics detector systems

Current investigations into neutrinoless double beta decay and the direct detection of dark matter require increasingly sensitive detector systems that demand ultra-low background materials. These requirements have previously been attained using ultra-radiopure electroformed (EF) copper. However, pure copper possesses high ductility and relatively low strength, which necessitates the need for large amounts of material and extra care during fabrication to help minimize galling and mechanical failure. Furthermore, we investigate an alloying alternative to pure EF copper by examining low wt% copper chrome (Cu–Cr) solid solution alloys, with inquiries into alloy hardness, strength, and radiopurity. Alloyed Cu–Cr layered samples are shown to exhibit significantly increased hardness compared to EF copper, for example showing a 50% increase in exhibited hardness using less than 1% Cr by weight, with limited negative impact to the material’s radiopurity.

Background↗

Rutherford-in-Copper-Channel Conductor for the MARCO Solenoidal Detector Magnet

MARCO will be a superconducting solenoid for a new particle physics detector of the upcoming Electron Ion Collider (EIC) at Brookhaven National Laboratory (NY, USA). The design field at the interaction point is 2.0 T with a nominal current of about 4 kA at 4.5 K. For this magnet, an aluminumstabilized conductor was considered at the very preliminary design phase. After that, since the lack of manufacturers able to deal with aluminum extrusion, copper has been chosen as stabilizer. Thanks to a dedicated design effort, the copper stabilizer and accompanying material choices provided acceptable hadronic interaction length. The conductor is based on a NbTi Rutherford cable that is soldered in a U-shaped copper profile. Here, this paper goes through the definition of the conductor crosssection according to the project requirements and the supplier capabilities. Its characteristics will be detailed and discussed, in particular the RRR and the yield strength of the copper channel needed for protection and mechanics respectively. Finally, a proposal on how to make the joint between two conductors is presented.

Stacchi, Francesco [Commissariat a l'Energie Atomi↗

First result of the experimental search for the 9.4 keV solar axion reactions with {sup 83}Kr in the copper proportional counter

The experimental search for solar hadronic axions is started at the Baksan Neutrino Observatory of the Institute for Nuclear Researches of Russian Academy of Science (BNO INR RAS). It is assumed that axions are created in the Sun during M1 transition between the first thermally excited level at 9.4 keV and the ground state in {sup 83}Kr. The experiment is based on axion detection via resonant absorption process by the same nucleus in the detector. The big copper proportional counter filled with krypton is used to detect signals from axions. The experimental setup is situated in the deep underground low background laboratory. No evidence of axion detection were found after the 26.5 days data collection. Resulting new upper limit on axion mass is m{sub A} ≤ 130 eV at 95% C.L.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effects of activation by proton irradiation on silicon particle detector electric characteristics

After irradiation with 7 and 9 MeV protons, activation-induced effects were encountered in measurements of current-voltage (IV) and capacitance-voltage (CV) characteristics for Czochralski and float-zone grown silicon particle detectors prepared on printed circuit boards with copper electrodes. With the present detector construction, the {sup 30}Si(p,n){sup 30}P and {sup 63}Cu(p,n){sup 63}Zn reactions induce dominant interference in such measurements. The daughter nuclides are positron emitters with half-lives of 2.5 and 38.5 min, respectively, and the slowing down of the emitted positrons generates a significantly large concentration of electron-hole pairs in the detector volume increasing the leakage current level and decreasing the breakdown voltage. The observed time-dependent characteristics were verified by modeling the activation of the detector structure and the resulting leakage current. As a result, the electrical measurements cannot be performed immediately after irradiation due to silicon activation, and, generally, materials becoming easily activated should be avoided in the detector concept.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Use of Electrodeposition for Sample Preparation and Rejection Rate Prediction for Assay of Electroformed Ultra High Purity Copper for 232Th and 238U Prior to Inductively Coupled Plasma Mass Spectrometry (ICP/MS)

The search for neutrinoless double beta decay in 76Ge has driven the need for ultra-low background Ge detectors shielded by electroformed copper of ultra-high radiopurity (<0.1µBq/kg). Although electrodeposition processes are almost sophisticated enough to produce copper of this purity, to date there are no methods sensitive enough to assay it. Inductively-coupled plasma mass spectrometry (ICP/MS) can detect thorium and uranium at femtogram levels, but in the past, this assay has been hindered by high copper concentrations in the sample. Electrodeposition of copper samples removes copper from the solution while selectively concentrating thorium and uranium contaminants to be assayed by ICP/MS. Spiking 232Th and 238U into the plating bath simulates low purity copper and allows for the calculation of the electrochemical rejection rate of thorium and uranium in the electroplating system. This rejection value will help to model plating bath chemistry.

copper, electroformation, germanium, thorium, uran↗

Results of experiments devoted to searches for 2K capture on {sup 78}Kr and for the double-beta decay of {sup 136}Xe with the aid of proportional counters

A brief description of two low-background setups deployed at the Baksan Neutrino Observatory (Institute for Nuclear Research, Russian Academy of Sciences) and intended for searches for two types of double-beta decay of inert-gas isotopes-2K capture on {sup 78}Kr and the double-beta decay of {sup 136}Xe-is given. The two setups in question have similar structures and employ identical large high-pressure copper proportional counters as detectors. Upon a treatment of data from measurements with krypton samples differing in the content of the isotope {sup 78}Kr, the spectrum for an enriched sample revealed an excess of events at a statistical-significance level of about two standard deviations (2{sigma}). If one attributes this excess to 2K(2{nu}) capture on {sup 78}Kr, the respective half-life is T{sub 1/2} = 1.4{sub -0.7}{sup +2.3} Multiplication-Sign 10{sup 22} yr at a 90% C.L. A treatment of data from measurements with xenon samples differing in content of the isotope {sup 136}Xe led to the appearance of an excess of events in the spectrum for an enriched sample at a statistical-significance level of about 2.2{sigma}. If one assumes that this excess is due to the two-neutrino double-beta decay of {sup 136}Xe, then the respective half-life is T{sub 1/2} = 5.8{sub -1.8}{sup +4.7} Multiplication-Sign 10{sup 21} yr.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Intense pulsed light annealing of copper zinc tin sulfide nanocrystal coatings

A promising method for forming the absorber layer in copper zinc tin sulfide [Cu{sub 2}ZnSnS{sub 4} (CZTS)] thin film solar cells is thermal annealing of coatings cast from dispersions of CZTS nanocrystals. Intense pulsed light (IPL) annealing utilizing xenon flash lamps is a potential high-throughput, low-cost, roll-to-roll manufacturing compatible alternative to thermal annealing in conventional furnaces. The authors studied the effects of flash energy density (3.9–11.6 J/cm{sup 2}) and number of flashes (1–400) during IPL annealing on the microstructure of CZTS nanocrystal coatings cast on molybdenum-coated soda lime glass substrates (Mo-coated SLG). The annealed coatings exhibited cracks with two distinct linear crack densities, 0.01 and 0.2 μm{sup −1}, depending on the flash intensity and total number of flashes. Low density cracking (0.01 μm{sup −1}, ∼1 crack per 100 μm) is caused by decomposition of CZTS at the Mo-coating interface. Vapor decomposition products at the interface cause blisters as they escape the coating. Residual decomposition products within the blisters were imaged using confocal Raman spectroscopy. In support of this hypothesis, replacing the Mo-coated SLG substrate with quartz eliminated blistering and low-density cracking. High density cracking is caused by rapid thermal expansion and contraction of the coating constricted on the substrate as it is heated and cooled during IPL annealing. Finite element modeling showed that CZTS coatings on low thermal diffusivity materials (i.e., SLG) underwent significant differential heating with respect to the substrate with rapid rises and falls of the coating temperature as the flash is turned on and off, possibly causing a build-up of tensile stress within the coating prompting cracking. Use of a high thermal diffusivity substrate, such as a molybdenum foil (Mo foil), reduces this differential heating and eliminates the high-density cracking. IPL annealing in presence of sulfur vapor prevented both low- and high-density cracking as well as blistering. However, grain growth was limited even after annealing with 400 flashes. This lack of grain growth is attributed to a difficulty of maintaining high sulfur vapor pressure and absence of alkali metal impurities when Mo foil substrates are used.

36 MATERIALS SCIENCE↗

Surrogate Distributed Radiological Sources—Part II: Aerial Measurement Campaign

In this second part of a multipaper series, we present results from outdoor aerial measurements of surrogate distributed gamma-ray sources. Here we detail the design, manufacture, and testing of 300 individual ~7 mCi Cu-64 sealed sources at the Washington State University (WSU) research reactor and their deployment in various source patterns (each comprising up to 100 point sources) during the aerial measurement campaign. We show the results of two such measurements, in which approximate source shapes and qualitative source intensities can be seen from the count rate versus position plots, even without performing reconstructions. We also detail our efforts in ground-truthing the deployed sources and comparing measured gamma-ray data to model predictions. In particular, we compare measured versus expected count data using the Poisson deviance formalism of Part I to evaluate whether the fielded surrogate point-source arrays “look like” their truly continuous distributed source analogs. More generally, we find that the point-source array technique provides high source placement accuracy, relative ease of quantifying the true source configuration, scalability to source dimensions of ≲100 m, ease of reconfiguration and removal, and relatively low dose to personnel. Finally, we consider potential improvements and generalizations of the point-source array technique for future measurement campaigns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗