Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COOLING TIME”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Thermospheric Heating and Cooling Times During Geomagnetic Storms, Including Extreme Events

We present the first quantitative calculations of thermospheric heating and cooling times for geomagnetic storms of different intensity, including extreme events. We utilize the neutral mass density database of the CHAllenging Mini‐satellite Payload and Gravity Recovery And Climate Experiment missions to produce thermospheric global system response to geomagnetic storms caused by coronal mass ejections via superposed epoch analysis during May 2001 to December 2015. Storm events are grouped in five different categories based on the minimum value of the SYM‐H index. We calculate the time from storm onset for the thermosphere to reach maximum intensification (heating time) and the time from onset for the thermosphere to recover (cooling time). We find that heating and cooling times decrease as storm intensity increases and the effect is more pronounced for the cooling times. For extreme storms, the thermospheric heating time is 9.5 hr, while the cooling time is 22 hr.

Zesta, Eftyhia↗

The cooling time scales of growing sunspots

The evolution of brightness and magnetic fields of growing sunspots is studied. Growing sunspots are found to be brighter (or less dark) than stable sunspots with the same magnetic field strength. From comparison of brightness and magnetic fields of a growing sunspot with those of stable sunspots, a dynamical parameter, the cooling time, of the growing sunspot is obtained. Ten growing sunspots are studied, and cooling times of 0.5 to 9 hr are found. Two models, the inhibition model and the Alfven wave model, give cooling times of about 0.05 hr, based on linear theory. The discrepancy between theory and observation may be due to the fact that the observed sunspots are in the nonlinear regime.

Chou, Dean-Yi↗

Effect of Interlayer Cooling Time, Constraint and Tool Path Strategy on Deformation of Large Components Made by Laser Metal Deposition with Wire

Laser metal deposition with wire (LMD-w) is a developing additive manufacturing (AM) technology that has a high deposition material rate and efficiency and is suitable for fabrication of large aerospace components. However, control of material properties, geometry, and residual stresses is needed before LMD-w technology can be widely adopted for the construction of critical structural components. In this study, we investigated the effect of interlayer cooling time, clamp constraints, and tool path strategy on part distortion and residual stresses in large-scale laser additive manufactured Ti-6Al-4V components using finite element method (FEM). The simulations were validated with the temperature and the distortion measurements obtained from a real LMD-w process. We found that a shorter interlayer cooling time, full clamping constraints on the build plates, and a bidirectional tool path with 180° rotation minimized part distortion and residual stresses and resulted in symmetric stress distribution.

36 MATERIALS SCIENCE↗

Multi-stage pulse tube cryocooler with acoustic impedance constructed to reduce transient cool down time and thermal loss

The cool down time for a multi-stage, pulse tube cryocooler is reduced by configuring at least a portion of the acoustic impedance of a selected stage, higher than the first stage, so that it surrounds the cold head of the selected stage. The surrounding acoustic impedance of the selected stage is mounted in thermally conductive connection to the warm region of the selected stage for cooling the acoustic impedance and is fabricated of a high thermal diffusivity, low thermal radiation emissivity material, preferably aluminum.

Gedeon, David R.↗

Process Variability Effects on Tensile Response in Injection Molded, Fluorinated Thermoplastics

The mechanical properties of fluorinated thermoplastics (i.e., tensile strength and elongation) can vary with changes in injection molding processing parameters. Four fluoropolymers are examined: poly(vinylidene fluoride) (PVDF) and random poly(vinylidene fluoride-co-chlorotrifluoroethylene) (PVDF-CTFE) with three CTFE concentrations. Dog bones were manufactured with various cylinder dwell times and mold cooling times to assess the manufacturing sensitivity to the tensile response. Dwell and cooling times increasingly impact mechanical performance as CTFE concentration increases. Specimens exhibit higher tensile strength as a function of injection order. The first injected specimen exhibits the lowest tensile strength and highest elongation in all copolymers. This trend becomes more pronounced among fluoropolymers with higher CTFE concentration and lower weight-averaged molecular weight. Parallel plate rheology was used to obtain the zero-shear viscosity as a function of material type, process, and injection order. We found that in the copolymers, the first injected sample exhibited a lower zero-shear viscosity than the next, which indicates a lower molecular weight in the first injected specimen. This phenomenon was not presented for the PVDF homopolymer. Copolymer mechanical uncertainties are hypothesized to result from the shorter molecular weight chains extruding out of the specimens' sides as a flash due to higher mobility with CTFE segments.

36 MATERIALS SCIENCE↗

Process Variability Effects on Tensile Response in Injection Molded, Fluorinated Thermoplastics

The mechanical properties of fluorinated thermoplastics (i.e., tensile strength and elongation) can vary with changes in injection molding processing parameters. Four fluoropolymers are examined: poly(vinylidene fluoride) (PVDF) and random poly(vinylidene fluoride-co-chlorotrifluoroethylene) (PVDF-CTFE) with three CTFE concentrations. Dog bones were manufactured with various cylinder dwell times and mold cooling times to assess the manufacturing sensitivity to the tensile response. Dwell and cooling times increasingly impact mechanical performance as CTFE concentration increases. Specimens exhibit higher tensile strength as a function of injection order. The first injected specimen exhibits the lowest tensile strength and highest elongation in all copolymers. This trend becomes more pronounced among fluoropolymers with higher CTFE concentration and lower weight-averaged molecular weight. Parallel plate rheology was used to obtain the zero-shear viscosity as a function of material type, process, and injection order. We found that in the copolymers, the first injected sample exhibited a lower zero-shear viscosity than the next, which indicates a lower molecular weight in the first injected specimen. This phenomenon was not present for the PVDF homopolymer. Copolymer mechanical uncertainties are hypothesized to result from the shorter molecular weight chains extruding out of the specimens’ sides as a flash due to higher mobility with CTFE segments.

36 MATERIALS SCIENCE↗

Thermal Non-equilibrium Consistent with Widespread Cooling

Time correlation analysis has been used to show widespread cooling in the solar corona; this cooling has been interpreted as a result of impulsive (nanoflare) heating. In this work, we investigate wide-spread cooling using a 3D model for a solar active region which has been heated with highly stratified heating. This type of heating drives thermal non-equilibrium solutions, meaning that though the heating is effectively steady, the density and temperature in the solution are not. We simulate the expected observations in narrowband EUV images and apply the time correlation analysis. We find that the results of this analysis are qualitatively similar to the observed data. We discuss additional diagnostics that may be applied to differentiate between these two heating scenarios.

Winebarger, A.↗

Thermal Non-equilibrium Consistent with Widespread Cooling

Time correlation analysis has been used to show widespread cooling in the solar corona; this cooling has been interpreted as a result of impulsive (nanoflare) heating. In this work, we investigate wide-spread cooling using a 3D model for a solar active region which has been heated with highly stratified heating. This type of heating drives thermal non-equilibrium solutions, meaning that though the heating is effectively steady, the density and temperature in the solution are not. We simulate the expected observations in narrowband EUV images and apply the time correlation analysis. We find that the results of this analysis are qualitatively similar to the observed data. We discuss additional diagnostics that may be applied to differentiate between these two heating scenarios.

Winebarger, A.↗

Cooling of solar flares plasmas. 1: Theoretical considerations

Theoretical models of the cooling of flare plasma are reexamined. By assuming that the cooling occurs in two separate phase where conduction and radiation, respectively, dominate, a simple analytic formula for the cooling time of a flare plasma is derived. Unlike earlier order-of-magnitude scalings, this result accounts for the effect of the evolution of the loop plasma parameters on the cooling time. When the conductive cooling leads to an 'evaporation' of chromospheric material, the cooling time scales L(exp 5/6)/p(exp 1/6), where the coronal phase (defined as the time maximum temperature). When the conductive cooling is static, the cooling time scales as L(exp 3/4)n(exp 1/4). In deriving these results, use was made of an important scaling law (T proportional to n(exp 2)) during the radiative cooling phase that was forst noted in one-dimensional hydrodynamic numerical simulations (Serio et al. 1991; Jakimiec et al. 1992). Our own simulations show that this result is restricted to approximately the radiative loss function of Rosner, Tucker, & Vaiana (1978). for different radiative loss functions, other scaling result, with T and n scaling almost linearly when the radiative loss falls off as T(exp -2). It is shown that these scaling laws are part of a class of analytic solutions developed by Antiocos (1980).

Cargill, Peter J.↗

The Relationship Between Dose Rate and Decay Heat for Spent Nuclear Fuel Casks

Decay heat and dose rate are two important limits used for determining the allowable contents of spent fuel (SNF) in dry storage systems and transportation packages. While the decay heat limit is used to maintain fuel cladding integrity and ensure retrievability, dose rates are used to demonstrate compliance with regulatory requirements on radiation protection. Because both dose rate and decay heat result from decay of radioisotopes in SNF, this study is an attempt to examine the relationship between dose rate and decay heat for a given cask design. Dose rates were evaluated for 198 cask configurations, that include various SNF system designs (e.g., storage, transfer, transport), SNF characteristics (e.g., fuel types, burnup, cooling time), and loading maps (e.g., uniform loading, zone loading), while a constant decay heat was maintained. The decay heat was calculated using US Nuclear Regulatory Commission (NRC) Regulatory Guide (RG) 3.54, Revision 2, and verified using ORIGEN sequence within SCALE code system. The ORIGEN outputs were used as source terms in the dose analysis using 198 different configurations. A computer script was developed to calculate the cooling time necessary to achieve a given decay heat for a given enrichment, assembly average burnup, assembly mass, and in-core history using a rootfinder algorithm. Initially the computer script was developed to provide cooling time and burnup calculations directly to the analysis of dose rates and decay heats, so a comparison between Used Nuclear Fuel-Storage Transportation and Disposal Analysis Resource Data System (UNF-ST&DARDS) results and RG3.54 data was made; results are included in the appendix to this document. However, an iterative approach was used to compute cooling time, and its accuracy did not depend on the results of the RG3.54r2 algorithm, although the algorithm was still used. The results of the evaluation presented herein clearly demonstrate that a given decay heat does not correspond to a unique dose rate for a variety of cask and package designs. There is no clear pattern to develop a correlation between decay heat and the source terms. Depending on burnup, enrichment, cask type, and loading pattern, dose rates varied for the exact same decay heat—in some cases by 400% for a given cask. For cases in which decay heat was held constant through selection of the appropriate cooling time, dose rates would decrease with increasing burnup, and in other cases, dose rates would increase. The large variation in dose rates for a constant decay heat indicates that casks loaded based on decay heat—that is allowing any burnup, cooling time, and enrichment combinations that yield the qualified decay heat limit(s) —cannot ensure that an Independent Spent Fuel Storage Installation or a spent fuel transportation package will meet the regulatory limits set forth by the respective regulations, i.e., 10 CFR 72 or 10 CFR 71.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lunar composition as a clue to the early history of the solar system.

The apparent conflict of the low iron content of the moon with the hypothesis of lunar capture is shown to be reconcilable if, in the inner solar system, iron condensations are assumed to conglomerate into planetary cores before the silicates condense to form a number of iron-poor moons. In the outer solar system, there would be no such fractionation, and, in the asteroid belt, the situation should be intermediate and quite complex. A crucial parameter is the ratio of coalescence time to cooling time, which depends on the density of the solar nebula. Also of importance are nonuniform cooling and condensation, as well as the outward transport of volatiles and their dissipation from the solar system. The model can explain also other features of the planets and asteroids.

Singer, S. F.↗

Real-time gas cooling of flowing liquid lithium limiter for the EAST

A novel continuously flowing liquid lithium limiter (FLiLi) which employs an in-vessel electro-magnetic pump to drive liquid Li flowing on the surface of limiter has been successfully designed and tested in the experimental advanced superconducting tokamak (EAST) device in 2014. In order to better control the surface temperature, an upgraded design and the real-time gas cooling were performed in 2016. Two kinds of cooling gas, helium (He) and argon (Ar) were tested on the FLiLi system prior to the experiment. It was found that the cooling rates of He and Ar at 2.5 MPa are 34.2 °C/min, 10.2 °C/min or 31.7 °C/kL and 28.1 °C/kL, respectively. The cooling performance of He is more effective than Ar. Experimental results show that the real-time He cooling could effectively contain the FLiLi surface temperature increase and prevent the strong passive evaporation of lithium during plasma discharges. Limiter heat flux up to 0.2 MW/m2 was removed during ohmic discharge with 2.5 MPa He gas. Finally, Because of the upgraded design and real-time gas cooling, the surface of FLiLi was not damaged by heat flux after entire plasma discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Over-Luminous Elliptical Galaxies

We have completed a first draft of a paper on the galaxy group ESO3060170, the hottest known fossil group. We have submitted a first draft of the paper but the final completion is delayed due to several issues mentioned by the referee that we wish to revisit and discuss in more detail. The XMM data was combined with Chandra data which allowed a rich set of projects. The paper discusses the north-south elongation which is similar to that of the central dominant galaxy as well as the galaxy distribution. We detect an X-ray 'finger' or small tail emanating from the central galaxy to the north, suggesting motion of the galaxy within the elongated gravitational potential. The overall agreement between XMM and Chandra data are excellent (although the XMM data extend to larger radii). Both data sets show a cool core centered on the dominant galaxy. Surprisingly, - the temperature maps and detailed spectra indicate that the finger of gas is NOT cool, but has the same temperature as the ambient gas. We extracted surface brightness profiles, deprojected gas density profiles, cooling time profiles, and entropy profiles. There is a sharp discontinuity in gas temperature where the surface brightness profile starts to rise rapidly at 10 kpc. This produces a decrease in the cooling time and the gas entropy within 10 kpc. The central cooling time (within 10 kpc) is less than 109 years and falls to almost half that value in the inner 5 kpc. Despite the very short cooling time, we find no evidence (even with the excellent statistics from XMM-Newton) for multi-phased gas, i.e., a cooling flow. We find two 'edges' associated with the gas distribution (common in peaked X-ray groups and galaxies). On large scales, the temperature profile is flat and disagrees with the profile predicted by Loken et al. (2003) from detailed numerical simulations. We studied the galaxy distribution within one virial radius. The galaxy concentration associated with the group is detectable only within 0.3 of the virial radius (450 kpc) given the available depth of the optical galaxy catalogs at present. We have derived total mass and gas mass distributions (from the X-ray data) and find the gas fraction approaches a constant 8% (for H0 = 70).

Mushotsky, Richard↗

Over-Luminous Elliptical Galaxies

We have completed a first draft of a paper on the galaxy group ES03060170, the hottest known fossil group. We have submitted a first draft of the paper but the final completion is delayed due to several issues mentioned by the referee that we wish to revisit and discuss in more detail. The XMM data was combined with Chandra data which allowed a rich set of projects. The paper discusses the north-south elongation which is similar to that of the central dominant galaxy as well as the galaxy distribution. We detect an X-ray "finger" or small tail emanating from the central galaxy to the north, suggesting motion of the galaxy within the elongated gravitational potential. The overall agreement between XMM and Chandra data are excellent (although the XMM data extend to larger radii). Both data sets show a cool core centered on the dominant galaxy. Surprisingly, the temperature maps and detailed spectra indicate that the finger of gas is NOT cool, but has the same temperature as the ambient gas. We extracted surface brightness profiles, deprojected gas density profiles, cooling time profiles, and entropy profiles. There is a sharp discontinuity in gas temperature where the surface brightness profile starts to rise rapidly at 10 kpc. This produces a decrease in the cooling time and the gas entropy within 10 kpc. The central cooling time (within 10 kpc) is less than l0(exp 9) years and falls to almost half that value in the inner 5 kpc. Despite the very short cooling time, we find no evidence (even with the excellent statistics from XMM-Newton) for multi-phased gas, i.e., a cooling flow. We find two "edges" associated with the gas distribution (common in peaked X-ray groups and galaxies). On large scales, the temperature profile is flat and disagrees with the profile predicted by Loken et al. (2003) from detailed numerical simulations. We studied the galaxy distribution within one virial radius. The galaxy concentration associated with the group is detectable only within 0.3 of the virial radius (450 kpc) given the available depth of the optical galaxy catalogs at present. We have derived total mass and gas mass distributions (from the X- ray data) and find the gas fraction approaches a constant 8% (for Ho = 70).

Mushotzky, Richard↗

Disruption thermal load mitigation with shattered pellet injection on the Joint European Torus (JET)

Disruption mitigation remains a critical, unresolved challenge for ITER. To aid in addressing this challenge, a shattered pellet injection (SPI) system was installed on JET and experiments conducted at a range of thermal energy fractions and stored energies in excess of 7 MJ. The primary goals of these experiments were to investigate the efficacy of the SPI on JET and the ability of the plasma to assimilate multiple pellets. Single pellet injections produced a saturation in total radiated energy (Wrad) with increasing injected neon content, suggesting total radiation of stored thermal energy. Further increases in injected neon quantities resulted in reduced cooling times and current quench (CQ) durations, indicating higher impurity assimilation. No significant variation in CQ duration or W rad was observed when varying the deuterium content at fixed neon quantities. Additionally, higher assimilation, inferred by shorter CQ durations, was measured when a mechanical punch was used to launch the pellets and this was attributed to a lower pellet velocity leading to higher solid content in the pellet plume and larger fragments penetrating deeper into the plasma. Radiation asymmetries averaged over the cooling time were inferred from Emis3D and ranged from 1.6 to 1.9. Asymmetries averaged over the entire disruption sequence were found to increase at higher thermal energy fractions. The radiated energy fractions decreased with increasing thermal energy fractions but this trend was eliminated when toroidal asymmetries were accounted for with Emis3D. Pure deuterium pellets were able to produce cooling times of up to 75 ms with a gradual loss in thermal stored energy of up to 80%. Experiments with multiple pellet injection indicated W rad can be increased through pellet superposition and density can be increased with an additional D2 injection without a reduction in W rad . KPRAD modelling accurately reproduced the cooling times and the CQ duration at high thermal energies. Assimilation estimates from KPRAD indicated CQ rates scale strongly whilst W rad scales weakly and saturates with assimilated neon content. Comparable W rad can be achieved with lower assimilated neon quantities as longer cooling times are attained. Thus reduced neon content can be preferential in a thermal load mitigation scheme as it may reduce radiation asymmetries and prevent flash melting.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗