An Assessment of NASA Glenn's Aeroacoustic Experimental and Predictive Capabilities for Installed Cooling Fans

Quiet, high performance electronics cooling fans are needed for both commercial applications and future manned space exploration missions. Researchers at NASA Glenn focusing on aircraft engine noise, have long been familiar with the challenge of reducing fan noise without sacrificing aerodynamic performance. Is it possible to capitalize on the lessons-learned in aircraft engine noise reduction to identify inexpensive ways to improve the aerodynamic and acoustic performance of electronics cooling fans? Recent tests at NASA Glenn have begun to look for answers to this question. The overall aerodynamic and acoustic performance of a commercially available, spaceflight qualified 80 mm diameter axial flow fan has been measured using an automated plenum in accordance with ISO 10302 in the hemi-anechoic chamber of NASA Glenn s Acoustical Testing Laboratory. These measurements are complemented by detailed aerodynamic measurements of the inlet, exhaust, and rotor wake regions of the fan using Particle Image Velocimetry and hot-wire probes. A study of preliminary results yielded recommendations for system designers, fan manufacturers, and researchers.

Koch, L. Danielle↗

An Assessment of NASA Glenn's Aeroacoustic Experimental and Predictive Capabilities for Installed Cooling Fans: Aerodynamic Performance - Part 1

Driven by the need for low production costs, electronics cooling fans have evolved differently than the bladed components of gas turbine engines which incorporate multiple technologies to enhance performance and durability while reducing noise emissions. Drawing upon NASA Glenn's experience in the measurement and prediction of gas turbine engine aeroacoustic performance, tests have been conducted to determine if these tools and techniques can be extended for application to the aerodynamics and acoustics of electronics cooling fans. An automated fan plenum installed in NASA Glenn's Acoustical Testing Laboratory was used to map the overall aerodynamic and acoustic performance of a spaceflight qualified 80 mm diameter axial cooling fan. In order to more accurately identify noise sources, diagnose performance limiting aerodynamic deficiencies, and validate noise prediction codes, additional aerodynamic measurements were recorded for two operating points: free delivery and a mild stall condition. Non-uniformities in the fan s inlet and exhaust regions captured by Particle Image Velocimetry measurements, and rotor blade wakes characterized by hot wire anemometry measurements provide some assessment of the fan aerodynamic performance. The data can be used to identify fan installation/design changes which could enlarge the stable operating region for the fan and improve its aerodynamic performance and reduce noise emissions.

VanZante, Dale E.↗

Reliability Assessment of Cooling Fans for PV Inverters: Testing, Modeling, and Case Studies

The reliability of photovoltaic (PV) inverters is critical for long-term solar system performance, with cooling fan failures frequently leading to costly downtime. While much research exists on general cooling fan reliability, little attention has been given to fans operating within PV inverters and their unique environmental challenges. Here, this article proposes a comprehensive methodology to address this gap. First, a failure mode and effects analysis is performed on fans to identify the key failure mechanisms in PV applications, their corresponding stressors, and the models necessary for lifetime prediction. Second, an accelerated life test is designed and conducted to collect valuable experimental data for PV inverter fans in a reasonable amount of time. Third, a mathematical conversion of dynamic mission profiles into effective constant stress levels is derived. Fourth, case studies are given, showcasing lifetime estimates that account for geographic variations in mission profile data. The results demonstrate that this integrated approach leads to an accurate reliability assessment for PV inverter cooling fans.

accelerated life testing (ALT)↗

Cool and Quiet: Partnering to Enhance the Aerodynamic and Acoustic Performance of Installed Electronics Cooling Fans: A White Paper

Breathtaking images of distant planets. Spacewalks to repair a telescope in orbit. Footprints on the moon. The awesome is made possible by the mundane. Every achievement in space exploration has relied on solid, methodical advances in engineering. Space exploration fuels economic development like no other endeavor can. But which advances will make their way into our homes and businesses? And how long will it take? Answers to these questions are dependent upon industrial involvement in government sponsored research initiatives, market demands, and timing. Recognizing an opportunity is half the battle. This proposal describes the framework for a collaborative research program aimed at improving the aerodynamic and acoustic performance of electronics cooling fans. At its best, the program would involve NASA and academic researchers, as well as corporate researchers representing the Information Technology (IT) and fan manufacturing industries. The momentum of space exploration, the expertise resultant from the nation's substantial investment in turbofan noise reduction research, and the competitiveness of the IT industry are intended to be catalysts of innovation.

Koch, L. Danielle↗

CFD MODELING AND ANALYSIS FOR A-AREA AND H-AREA COOLING TOWERS

Mechanical draft cooling towers are designed to cool process water via sensible and latent heat transfer to air. Heat and mass transfer take place simultaneously. Heat is transferred as sensible heat due to the temperature difference between liquid and gas phases, and as the latent heat of the water as it evaporates. Mass of water vapor is transferred due to the difference between the vapor pressure at the air-liquid interface and the partial pressure of water vapor in the bulk of the air. Equations to govern these phenomena are discussed here. The governing equations are solved by taking a computational fluid dynamics (CFD) approach. The purpose of the work is to develop a three-dimensional CFD model to evaluate the flow patterns inside the cooling tower cell driven by cooling fan and wind, considering the cooling fans to be on or off. Two types of the cooling towers are considered here. One is cross-flow type cooling tower located in A-Area, and the other is counterflow type cooling tower located in H-Area. The cooling tower located in A-Area is mechanical draft cooling tower (MDCT) consisting of four compartment cells as shown in Fig. 1. It is 13.7m wide, 36.8m long, and 9.4m high. Each cell has its own cooling fan and shroud without any flow communications between two adjacent cells. There are water distribution decks on both sides of the fan shroud. The deck floor has an array of about 25mm size holes through which water droplet falls into the cell region cooled by the ambient air driven by fan and wind, and it is eventually collected in basin area. As shown in Fig. 1, about 0.15-m thick drift eliminator allows ambient air to be humidified through the evaporative cooling process without entrainment of water droplets into the shroud exit. The H-Area cooling tower is about 7.3 m wide, 29.3 m long, and 9.0 m high. Each cell has its own cooling fan and shroud, but each of two corner cells has two panels to shield wind at the bottom of the cells. There is some degree of flow communications between adjacent cells through the 9-in gap at the bottom of the tower cells as shown in Fig. 2. Detailed geometrical dimensions for the H-Area tower configurations are presented in the figure. The model was benchmarked and verified against off-site and on-site test results. The verified model was applied to the investigation of cooling fan and wind effects on water cooling in cells when fans are off and on. This report will discuss the modeling and test results.

42 ENGINEERING↗

Development of Inboard Nacelle for the XB-36 Airplane

A series of investigations of several 1/14-scale models of an inboard nacelle for the XB-36 airplane was made in the Langley two-dimensional low-turbulence tunnels. The purpose of these investigations was to develop a low-drag wing-nacelle pusher combination which incorporated an internal air-flow system. As a result of these investigations, a nacelle was developed which had external drag coefficients considerably lower than the original basic form with the external nacelle drag approximately one-half to two-thirds of those of conventional tractor designs. The largest reductions in drag resulted from sealing the gaps between the wing flaps and nacelle, reducing the thickness of the nacelle training-edge lip, and bringing the under-wing air inlet to the wing leading edge. It was found that without the engine cooling fan adequate cooling air would be available for all conditions of flight except for cruise and climb at 40,000 feet. Sufficient oil cooling at an altitude of 40,000 feet may be obtained by the use of flap-type exit doors.

Nuber, Robert J.↗

Navier-Stokes Simulation of Airconditioning Facility of a Large Modem Computer Room

NASA recently assembled one of the world's fastest operational supercomputers to meet the agency's new high performance computing needs. This large-scale system, named Columbia, consists of 20 interconnected SGI Altix 512-processor systems, for a total of 10,240 Intel Itanium-2 processors. High-fidelity CFD simulations were performed for the NASA Advanced Supercomputing (NAS) computer room at Ames Research Center. The purpose of the simulations was to assess the adequacy of the existing air handling and conditioning system and make recommendations for changes in the design of the system if needed. The simulations were performed with NASA's OVERFLOW-2 CFD code which utilizes overset structured grids. A new set of boundary conditions were developed and added to the flow solver for modeling the roomls air-conditioning and proper cooling of the equipment. Boundary condition parameters for the flow solver are based on cooler CFM (flow rate) ratings and some reasonable assumptions of flow and heat transfer data for the floor and central processing units (CPU) . The geometry modeling from blue prints and grid generation were handled by the NASA Ames software package Chimera Grid Tools (CGT). This geometric model was developed as a CGT-scripted template, which can be easily modified to accommodate any changes in shape and size of the room, locations and dimensions of the CPU racks, disk racks, coolers, power distribution units, and mass-storage system. The compute nodes are grouped in pairs of racks with an aisle in the middle. High-speed connection cables connect the racks with overhead cable trays. The cool air from the cooling units is pumped into the computer room from a sub-floor through perforated floor tiles. The CPU cooling fans draw cool air from the floor tiles, which run along the outside length of each rack, and eject warm air into the center isle between the racks. This warm air is eventually drawn into the cooling units located near the walls of the room. One major concern is that the hot air ejected to the middle isle might recirculate back into the cool rack side and cause thermal short-cycling. The simulations analyzed and addressed the following important elements of the computer room: 1) High-temperature build-up in certain regions of the room; 2) Areas of low air circulation in the room; 3) Potential short-cycling of the computer rack cooling system; 4) Effectiveness of the perforated cooling floor tiles; 5) Effect of changes in various aspects of the cooling units. Detailed flow visualization is performed to show temperature distribution, air-flow streamlines and velocities in the computer room.

Source record↗

Cooling methods for medium voltage drive systems

In one aspect, a medium voltage power converter includes a cabinet having: a power cube bay to house a plurality of power cubes, each of the plurality of power cubes adapted within a corresponding enclosure and comprising a low frequency front end stage, a DC link and a high frequency back end stage, the plurality of power cubes to couple to a high speed machine; and a plurality of first barriers adapted to isolate and direct a first flow of cooling air through one of the plurality of power cubes; and a transformer bay having at least one transformer to couple between a utility connection and the plurality of power cubes, the transformer bay including a plurality of cooling fans to cool the at least one transformer.

Ledezma, Enrique↗

An algorithmic approach to predicting mechanical draft cooling tower fan speeds from infrasound signals

Mechanical draft cooling towers (MDCTs) serve a critical heat management role in a variety of industries. For nuclear reactors in particular, the consistent, predictable operation of MDCTs is required to avoid damage to infrastructure and reduce the potential for catastrophic failure. Accurate, reliable measurement of MDCT fan speed is therefore an important maintenance and safety requirement. To that end, we have developed an algorithm for automatically predicting the rotational speeds of multiple, simultaneously operating fan rotors using contactless, infrasound measurements. The algorithm is based on identifying the blade passing frequencies (BPFs), their harmonics, as well as the motor frequencies (MFs) for each fan in operation. Using the algorithm, these frequencies can be automatically identified in the acoustic waveform’s short-time Fourier transform spectrogram. Attribution is aided by a set of filters that rely on the unique spectral and temporal characteristics of fan operation, as well as the intrinsic frequency ratios of the BPF harmonics and the BPF/MF signals. The algorithm was tested against infrasound data acquired from infrasound sensors deployed at two research reactors: the Advanced Test Reactor (ATR) located at Idaho National Laboratory (INL) and the High Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory (ORNL). After manually identifying the MDCT gearbox ratio, the algorithm was able to quickly yield fan speeds at both reactors in good agreement with ground truth. Ultimately, this work demonstrates the ease by which MDCT fans may be monitored in order to optimize operational conditions and avoid infrastructure damage.

42 ENGINEERING↗

Recovery Act: Federspiel Controls (now Vigilent) and State of California Department of General Services Data Center Energy Efficient Cooling Control Demonstration. Final technical project report

Eight State of California data centers were equipped with an intelligent energy management system to evaluate the effectiveness, energy savings, dollar savings and benefits that arise when powerful artificial intelligence-based technology measures, monitors and actively controls cooling operations. Control software, wireless sensors and mesh networks were used at all sites. Most sites used variable frequency drives as well. The system dynamically adjusts temperature and airflow on the fly by analyzing real-time demands, thermal behavior and historical data collected on site. Taking into account the chaotic interrelationships of hundreds to thousands of variables in a data center, the system optimizes the temperature distribution across a facility while also intelligently balancing loads, outputs, and airflow. The overall project will provide a reduction in energy consumption of more than 2.3 million kWh each year, which translates to $240,000 saved and a reduction of 1.58 million pounds of carbon emissions. Across all sites, the cooling energy consumption was reduced by 41%. The average reduction in energy savings across all the sites that use VFDs is higher at 58%. Before this case study, all eight data centers ran the cooling fans at 100% capacity all of the time. Because of the new technology, cooling fans run at the optimum fan speed maintaining stable air equilibrium while also expending the least amount of electricity. With lower fan speeds, the life of the capital investment made on cooling equipment improves, and the cooling capacity of the data center increases. This case study depicts a rare technological feat: The same process and technology worked cost effectively in eight very different environments. The results show that savings were achieved in centers with diverse specifications for the sizes, ages and types of cooling equipment. The percentage of cooling energy reduction ranged from 19% to 78% while keeping temperatures substantially within the limits recommended by the American Society of Heating, Refrigeration, and Air-Conditioning Engineers (ASHRAE) for data center facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal Design and Analysis for the Cryogenic MIDAS Experiment

The Materials In Devices As Superconductors (MIDAS) spaceflight experiment is a NASA payload which launched in September 1996 on the Shuttle, and was transferred to the Mir Space Station for several months of operation. MIDAS was developed and built at NASA Langley Research Center (LaRC). The primary objective of the experiment was to determine the effects of microgravity and spaceflight on the electrical properties of high-temperature superconductive (HTS) materials. The thermal challenge on MIDAS was to maintain the superconductive specimens at or below 80 K for the entire operation of the experiment, including all ground testing and 90 days of spaceflight operation. Cooling was provided by a small tactical cryocooler. The superconductive specimens and the coldfinger of the cryocooler were mounted in a vacuum chamber, with vacuum levels maintained by an ion pump. The entire experiment was mounted for operation in a stowage locker inside Mir, with the only heat dissipation capability provided by a cooling fan exhausting to the habitable compartment. The thermal environment on Mir can potentially vary over the range 5 to 40 C; this was the range used in testing, and this wide range adds to the difficulty in managing the power dissipated from the experiment's active components. Many issues in the thermal design are discussed, including: thermal isolation methods for the cryogenic samples; design for cooling to cryogenic temperatures; cryogenic epoxy bonds; management of ambient temperature components self-heating; and fan cooling of the enclosed locker. Results of the design are also considered, including the thermal gradients across the HTS samples and cryogenic thermal strap, electronics and thermal sensor cryogenic performance, and differences between ground and flight performance. Modeling was performed in both SINDA-85 and MSC/PATRAN (with direct geometry import from the CAD design tool Pro/Engineer). Advantages of both types of models are discussed. Correlation of several models to ground testing and flight data (where available) is presented. Both SINDA and PATRAN models predicted the actual thermal performance of the experiment well, even without post-flight correlation adjustments of the models.

Amundsen, Ruth McElroy↗

Large-Scale Simulations and Detailed Flow Field Measurements for Turbomachinery Aeroacoustics

The presentation is a review of recent work in highly loaded compressors, turbine aeroacoustics and cooling fan noise. The specific topics are: the importance of correct numerical modeling to capture blade row interactions in the Ultra Efficient Engine Technology Proof-of-Concept Compressor, the attenuation of a detonation pressure wave by an aircraft axial turbine stage, current work on noise sources and acoustic attenuation in turbines, and technology development work on cooling fans for spaceflight applications. The topic areas were related to each other by certain themes such as the advantage of an experimentalist s viewpoint when analyzing numerical simulations and the need to improve analysis methods for very large numerical datasets.

VanZante, Dale↗

Safety considerations in the design of Spacelab refrigerator/freezer

A vapor compression refrigerator/freezer has been designed for Spacelab to conduct life sciences experiments. It is equipped with different safety features to eliminate all probable types of failures. The whole Freon loop is enclosed in a second containment so that any leakage of Freon can be contained. The unit is provided with an 'Emergency On' switch to actuate during backup mode which provides the spacecraft power directly to the compressor and the cooling fans while removing the power supply and all normal control elements from the circuit. During this mode, the compressor runs continuously when operating as a freezer (-22 C) and is controlled by a thermostat to cycle when operating as a refrigerator (4 C). It has a push button switch at the front panel to momentarily power the thermometer by a battery to monitor the inside temperature during an emergency. It has a door switch which shuts off the internal cooling fans when the door is opened. All the important critical performance data will be downlinked through a data connector to monitor during mission.

Hye, A.↗