Engineering PapersSearch

SEARCH · Engineering Papers

Results for “COOLING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Cooling Matters: Benchmarking Large Language Models and Vision-Language Models on Liquid-Cooled Versus Air-Cooled H100 GPU Systems

The unprecedented growth in artificial intelligence (AI) workloads, recently dominated by large language models (LLMs) and vision-language models (VLMs), has intensified power and cooling demands in data centers. This study benchmarks LLMs and VLMs on two HGX nodes, each with 8× NVIDIA H100 graphics processing units (GPUs), using liquid and air cooling. Leveraging GPU Burn, Weights & Biases, and IPMItool, we collect detailed thermal, power, and computation data. Results show that the liquid-cooled systems maintain GPU temperatures between 41-50$^\circ$C, while the air-cooled counterparts fluctuate between 54-72$^\circ$C under load. This thermal stability of liquid-cooled systems yields 17% higher performance (54 TFLOPs/ GPU vs. 46 TFLOPs/GPU), performance-per-watt, reduced energy overhead, and greater system efficiency than the air-cooled counterparts. These findings underscore the energy and sustainability benefits of liquid cooling, offering a compelling path forward for hyperscale data centers seeking to optimize AI infrastructure. https://github.com/iscaas/Cooling-Matters.

Latif, Imran

Geospatial characterization of low-temperature heating and cooling demand in residential, commercial, manufacturing, agricultural, and data center sectors for potential geothermal applications in the United States

Thermal demand for heating and cooling has been predominantly supplied by fossil fuel combustion in the United States, although low-carbon alternatives are extensively available including geothermal, solar thermal, and waste heat. Here, this study analyzed end-use energy consumption, fuel expenditure, and data center commissioned power data to geospatially characterize the U.S. low-temperature heating and cooling demand at the county level in residential, commercial, manufacturing, agricultural, and data center sectors and understand potential opportunities for geothermal applications. In the analysis, the regional-scale energy consumption data was incorporated with system efficiencies to address actual demand and was then disaggregated with weighting factors to the county level. The results indicated that total low-temperature heating and cooling demand is 16.7 EJ, combining heating demand of 10.8 EJ and cooling demand of 5.9 EJ. Overall, 59.9 % (10 EJ) of the low-temperature heating and cooling demand occurred in the residential sector. The heating and cooling demand visualized in maps represented that the geospatial distribution of heating and cooling demand in the residential and commercial sectors is governed by the number of housing units and climate zone designations, while heating and cooling demand in the manufacturing, agricultural, and data center sectors is dependent on the number and location of facilities. The results also demonstrated that geothermal heat pumps are broadly used in the residential and commercial sectors for heating and cooling in the U.S. Midwest, South, and Northeast regions but are limited in the West, implying great decarbonization potential in the future.

15 GEOTHERMAL ENERGY

Power generation-cooling water Nexus: Impacts of cooling water shortage on power system operation - a simulation case study in Illinois, U.S

Cooling water shortage, frequently attributed to drought and heat waves, poses a significant threat to the operations of thermoelectric power plants and further poses a challenge for the entire power system and environmental stakeholders. Recognizing the critical nexus between power generation and cooling water availability and the potential ability of power generations to adjust generation schedules during cooling water shortages, this paper introduces a security-constrained unit commitment and economic dispatch model considering water-energy nexus. In specific, the model is augmented with a unit-level cooling water requirement (CWR) model and multi-level cooling water availability (CWA) constraints. The unit-level CWR model quantifies the cooling water withdrawal per MWh of power generation, taking into account factors such as thermoelectric generation technologies, cooling system technologies, and environmental parameters. The multi-level CWA constraints incorporate pump-level, plant-level, watershed-level, and forced minimum power constraints, utilizing data derived from actual-based cooling water shortage scenarios. Using a simulation case study in Illinois, United States, this research examines the reliability, economic, and environmental implications of cooling water shortages on power system operations. The results show that Illinois may experience 10-15% daily load curtailment and severe congestion between certain regions from the east to central during cooling water shortages, while once-through and wet-tower units experience a 52% and 17% reduction in power generation. In conclusion, overall cooling water withdrawal decreases by 24-38% as severity intensifies.

Cooling water shortage

Where to cool off: a geospatial framework for placement of cooling centers

Indoor cooling is essential to reduce heat stress and increase passive survivability during heatwaves. Although air conditioning (AC) is recommended for maintaining indoor thermal comfort, low- and medium-income households in the U.S. often do not own an AC and/or limit AC usage to reduce energy consumption and associated costs, thereby risking their health and safety. With the frequency and intensity of heatwaves increasing, cooling centers are considered an appropriate alternative to indoor cooling and a possible mitigation strategy to prevent adverse health impacts of heat exposure. However, these centers are limited in numbers and not always accessible. This requires (i) developing a geospatial framework using physical and social factors for optimal siting of cooling centers to meet future needs and (ii) ranking of existing and potential cooling centers (schools, libraries, religious institutions) based on their accessibility among vulnerable populations and proximity to healthcare facilities. We developed and deployed a geospatial framework based on the Multi-criteria Decision Analysis approach in five U.S. cities (Los Angeles (LA), Phoenix, Austin, Atlanta, Miami) to evaluate the effectiveness of the framework in ranking cooling centers based on accessibility and population coverage. The results revealed that (i) access to cooling centers varies across cities and 32.2–50.7% of centers are within walking distance of the most vulnerable populations, (ii) vulnerable populations exposed to Urban Heat Island (UHI) effects are more likely to experience energy burden, and (iii) about 21.2–49.4% of population with high energy burden have access to these centers. Considering that more cooling centers are needed to assist energy burdened households alleviate heat exposure impacts, the framework developed herein could be adapted to incorporate other factors (e.g. health impacts, policies) to assess site suitability of existing shelters, identify potential sites for new cooling centers, and geo-target communities where energy efficient emerging technologies could be deployed to reduce heat stress.

58 GEOSCIENCES

Cool rooms for indoor heat resilience: Evaluating affordable cooling strategies in heat-stressed California homes

Extreme heat conditions pose significant indoor survivability challenges for resource-constrained communities, which often lack access to cooling, have poorly insulated homes, and face compounding socioeconomic vulnerabilities. Moreover, concurrent power outages worsen health risks and heat-related illnesses. It is therefore crucial to develop innovative and affordable cooling approaches to protect vulnerable populations. This study assesses the efficacy of “cool rooms”– a designated space within a home equipped with passive and low-power active cooling measures to maintain safe indoor temperatures during extreme heat events and power disruptions. Using a physics-based building energy modeling approach, we evaluate the efficacy of various retrofit packages in maintaining thermal safety within the cool room under recent extreme heat conditions. The results indicate that passive measures can reduce 64% of hours with unmet standard effective temperatures, while the combination of passive and low-power active measures with built-in batteries further cuts this to 86%. Nevertheless, these strategies remain insufficient to maintain indoor thermal safety during extended outages. In contrast, integrating a solar-powered mini-split heat pump, whose technical potential was evaluated in this study, reduces indoor air temperatures below the 28 °C overheating threshold and significantly improves indoor habitability. The localized cool room strategy also offers potential for grid resilience by reducing peak electricity demand by up to 70% compared to whole house cooling during heat waves. The findings can inform the development of actionable heat mitigation plans and retrofit policies for residential communities with relatively low adoption of air conditioning such as warm marine climates.

Cool room

Overall Cooling Effectiveness of Internally Cooled Additively Manufactured Blades

Power generation gas turbine blades must utilize highly effective cooling schemes to withstand moderate heat loads for long operating times. Prior work indicates that gas turbines in the 5-10 MW range primarily utilize internal cooling to prevent further increase of aerodynamic losses that result from film cooling, but few studies focus solely on internal cooling. In this study, three additively manufactured internal cooling designs were tested in the 50 percent span section of the National Experimental Turbine (NExT) blade: a baseline cooling design with pin-fin arrays and rib turbulators, a double wall design with impingement jets and serpentine channels, and an incremental impingement design. The designs were tested in a high-speed linear cascade at exit Reynolds numbers ranging from 700,000 to 1,400,000 at an exit Mach of 0.8. In addition, freestream turbulence and build angle effects on cooling performance were studied.

gas turbine blades

Numerical Simulation of a Natural Convection–Driven Air-Cooled Reactor Cavity Cooling System Experiment

Ensuring the efficient removal of decay heat from the reactor vessel is essential for the safety of advanced reactor technologies. Several Generation-IV concepts incorporate variations in the reactor vessel cooling systems to achieve this objective. High-temperature gas-cooled reactors utilize a reactor cavity cooling system (RCCS), a passive ex-vessel system designed to operate without active components or external power during accident conditions. The RCCS removes decay heat primarily through radiative and convective heat transfer mechanisms. Here, this study presents a comprehensive validation of a computational fluid dynamics Reynolds-averaged Navier-Stokes model for the University of Wisconsin-Madison air-cooled RCCS facility. Validation was conducted for both high- and low-power natural convection cases under a uniform heating profile. Near-wall resolution was found to be critical for accurately modeling natural convection in the RCCS; employing an all-𝑦 + wall treatment resulted in wall temperature discrepancies exceeding 50 °⁢𝐶 compared to a wall-resolved mesh. Thermal-hydraulic behaviors under natural and forced convection conditions were compared within the heated cavity and RCCS. A turbulence model sensitivity analysis indicated that low-Reynolds number k-ɛ, k-ω shear stress transport (SST), and Reynolds stress transport models produce similar wall temperature predictions. A buoyancy modeling sensitivity study revealed that the Boussinesq approximation significantly underpredicted thermal-hydraulic behavior in the RCCS. Based on these findings, modeling recommendations are provided. The validated data set along with identified sensitivities refine the modeling of natural convection in the RCCS. The information produced by this study supports RCCS design, optimization, and safety evaluations, enabling the calibration and verification of reduced-order thermal-hydraulic models.

22 - GENERAL STUDIES OF NUCLEAR REACTORS

Thermal Performance of a Conduction-Cooled CCT Dipole ReBCO Magnet: Several Cycles of Cool-Down and Thermal Gradient Measurements

Here, this paper presents experimental results from conduction-cooled thermal testing of a ReBCO canted cosine theta (CCT) magnet (C2), originally designed and fabricated at LBNL using CORC cables. While the performance of the coil under liquid helium and nitrogen environments has been previously established, this study explores its behavior under conduction cooling using a large test cryostat at The Ohio State University. The magnet, measuring 613 mm in length and weighing ∼75 kg, consists of four helical layers wound with ReBCO-based CORC wire and was thermally anchored to a copper cold ring supported by a G-10 strongback. Cooling was provided by two Sumitomo RDK-415D cryocoolers, offering a combined 3 W at 4.2 K and 150 W at 77 K. Multiple thermal cycles were performed, with cooldown durations of up to 45 hours. Final base temperatures of approximately 10.8 K (at the coil edge) and 12.0 K (at the coil center) were achieved, with an axial temperature difference of approximately 1.2 K. The warm-up period extended over approximately 24.6 hours. Voltage measurements from all four layers were recorded during cooldown and warmup. The system demonstrated stable cooldown performance, repeatable gradients, and good thermal anchoring. These results support the feasibility of conduction cooling in large-scale HTS magnets, aligning with broader goals for “green” cryogen-free accelerator technologies and paving the way for more sustainable, scalable, and energy-efficient high-field magnet systems in next-generation particle accelerators.

Canted cosine theta magnets

Cooling Design and Thermal Analysis for Thermal Shields of a Cryocooler-Cooled Superconducting ECR Ion Source MARS-D Magnet

Here, a demonstrative NbTi based Mixed Axial and Radial field System (MARS-D) is being developed for a next-Generation Electron Cyclotron Resonance Ion Source (ECRIS) at Lawrence Berkeley National Laboratory (LBL), which employs a novel closed-loop coil design scheme that more efficiently utilizes conductor fields and extend the application of NbTi for high frequency (up to 45 GHz) ECR operation. The NbTi MARS-D magnet consists of a single hexagonally shaped closed-loop coil and a set of auxiliary solenoids. A cryostat for cooling the MARS-D magnet is under design at LBL. The MARS-D magnet working around 4.2 K will be bath-cooled in liquid helium using multiple two-stage cryocoolers. An intermediate temperature thermal radiation shield is adopted to reduce the heat leakage imposed on 4.2 K coil cold mass from room temperature. The thermal shield is conduction-cooled by the first-stage cold heads of four two-stage cryocoolers and the cold head of a single-stage cryocooler shared with nine binary leads. The temperature in the area of the shield that warm ends of HTS leads are mounted on is expected no higher than 60 K, which is limited by maximum allowable working temperature of HTS leads. The paper presents thermal analysis on the thermal radiation shield including heat loads and effects of eddy current induced during quench on its material selection.

ECRIS

High-fidelity forced convection simulations of the University of Wisconsin–Madison air-cooled reactor cavity cooling system

Among the various types of advanced nuclear technologies that exist, high-temperature gas-cooled reactors (HTGRs) stand out for their co-generation capabilities and exceptional passive safety systems. HTGRs rely on a reactor cavity cooling system (RCCS) to remove decay heat from the reactor pressure vessel (RPV) during the course of long-term transients. Several studies have focused on experimental and numerical modeling of the RCCS; however, the literature reveals a notable gap when it comes to high-fidelity simulations such as direct numerical simulations (DNS) or large eddy simulation (LES) models of the RCCS. An LES model was developed for forced convection inside the RCCS so as to obtain a high-fidelity representation of the RCCS at a scale never before attempted. Furthermore, the LES model was compared against three different Reynolds-averaged Navier–Stokes (RANS) models (Realizable k − ϵ, k − ω SST, and Reynolds stress model [RSM]). This comparison verified the robustness and accuracy of the turbulence modeling approach of the RANS models for the RCCS. Finally, based on the comparison between the LES and the RANS models, the k − ω SST RANS model of the experimental facility was developed and compared against the available experimental data.

22 - GENERAL STUDIES OF NUCLEAR REACTORS

Challenges and Optimization of Mu2e Proton Target Design with Radiative Cooling

Mu2e, the Muon-to-Electron Conversion Experiment, aims to identify physics beyond the Standard Model, namely, the conversion of muons to electrons without the emission of neutrinos. The muons are produced from pions generated in a production target when it is hit by an 8 GeV proton beam from the Fermilab Booster/Main Injector. The proton target design space is strongly constrained by a one-year operating lifetime and the need for radiative cooling in a vacuum environment. Uncertainties in the lifetime of the existing baseline design – a monolithic, segmented tungsten target – are large, particularly due to unknown impacts of radiation damage at the very high proton fluences expected in the experiment. We have begun evaluation of a new design utilizing Inconel 718 over the WL10 used in the existing target design. As a result, the structural design of the target has evolved significantly. This evolution focuses on lowering the target temperature, minimizing obstruction to muons, increasing structural stability, maximizing fatigue lifetime, simplifying the fabrication process, and more. The thermal management, structural stability and fatigue lifetime are emphasized here. These optimizations have led to a promising new target design for the Mu2e experiment.

Liu, Z. [Fermilab]

Overall Cooling Effectiveness of Internally Cooled Additively Manufactured Blades

By utilizing additive manufacturing, novel internal cooling designs can be quickly and cheaply vetted to enhance blade cooling performance. This improvement allows for higher turbine inlet temperatures while reducing the amount of coolant needed, therefore increasing the overall efficiency of small industrial gas turbines.

additive manufacturing

Corrigendum to “Cool Rooms for Indoor Heat Resilience: Evaluating Affordable Cooling Strategies in Heat-Stressed California Homes” [Building and Environment 287 (2026) 113877]

The authors regret an error in the acknowledgments section regarding the U.S. Department of Energy Solar Energy Technologies Office award number. The previously listed grant number, 2597–1625, was incorrect. The corrected acknowledgment should read: “This work was supported by the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of Building Technologies of the United States Department of Energy (DOE), under Contract No. DE-AC02–05CH11231. This material is based upon work supported by the U.S. Department of Energy's Office of Energy Efficiency and Renewable Energy (EERE) under the Solar Energy Technologies Office Award Number DE-EE00040384. Any opinions, findings, and conclusions or recommendations expressed in this material are those of the author(s) and do not necessarily reflect the views of the Department of Energy.” The authors would like to apologise for any inconvenience caused.

Malik, Jeetika

Data Center Immersion Cooling: A Case Study and Summary of High-Performance Computing Cooling Technologies

The future of High Performance Computing (HPC) is carved out for all high-performance facilities. As computer processing increases exponentially, especially with the demand for AI training, more speed will equate to more computing density and ultimately more power draw and resource demand. Sandia National Laboratories has not seen or known of anything that would lead us to think this might change in the next 5 to 10 years.

97 MATHEMATICS AND COMPUTING

A prototype cooling blanket for mitigating occupant overheating risk in a hot indoor environment: Modeling and assessments

Conventional ways of cooling a room or an entire house for occupant thermal comfort during summer consume a significant amount of energy and are vulnerable to overheating risk during power outages that lead to loss of cooling system operations. This study investigates a low-power cooling blanket, as a Personal Cooling System (PCS), that covers the upper human body for direct cooling during a five-day heat wave in a single-family house. A modeling framework is developed for evaluating the thermal and energy performance of the cooling blanket, which builds upon the co-simulation of three models: a house energy model, a personal thermal comfort model, and a cooling blanket model. Simulation results show that under the power outage scenario, the cooling blanket can greatly reduce the occupant heat stress with a reduction of daily hours of exceedance (discomfort hours defined as TSV>2) by up to 17.2 h (a 95.3 % improvement from the baseline power outage without the blanket). The cooling blanket, equipped with an innovative electrocaloric heat pump (COP as high as 10.1) consumes 6.31 W and can be operated by a portable battery for several days. The cooling blanket consumes only 0.28 % of the electricity of a central air-conditioning system running to provide cooling for the whole house during the five-day heatwave period. The findings justify further research of electrocaloric wearable PCS as low-power effective cooling to ensure thermal survivability of occupants during extreme indoor environments.

Electrocaloric heat pump

Case Study of Integrating High-Temperature Heat Pump with LiBr-H2O Absorption Chiller for Data Center Liquid Cooling

Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity

Wang, Pengtao [ORNL] (ORCID:0000000214713429)

Direct numerical simulations of turbulent premixed cool flames: Global and local flame dynamics analysis

The cool flame dynamics, especially in turbulent flows, is of great interest for both practical application and fundamental research. Here, in this study, a series of direct numerical simulations of turbulent premixed n-C 7 H 16 /O 2 /O 3 /N 2 cool flames are performed, with the focus on the influence of turbulence intensity (u'/S L , where S L is the laminar flame speed) on the flame structure as well as the global and local cool flame dynamics. It is found that the cool flame front is considerably wrinkled by turbulence at high u'/S L , leading to significantly thickened turbulent cool flame brush and largely altered local reactivity compared with the reference laminar flame. However, the turbulent flame structure in the temperature space is found to be insensitive to u'/S L . Besides, with increasing u'/S L , the normalized turbulent cool flame speed (S L /S L ) is monotonically increased, attributed to substantial augmentation on the flame surface area (A T /A L ), while the stretching factor (I 0 ) remains almost constant and is smaller than 1. The underlying mechanisms for such variations are revealed through local flame dynamics analysis. Specifically, the local flame displacement speed S d is found to be strongly negatively correlated with flame curvature; meanwhile, such negative correlation and the probability distribution function (PDF) of flame curvature are barely influenced by u'/S L , leading to a weak dependence of I 0 on u'/S L . In contrast, the PDF of the tangential strain rate is found to span a much wider range and shift to the positive side as u'/S L increases, suggesting that the enhanced tangential strain rate is the main cause for the increase in surface area of the turbulent premixed cool flame. Finally, the influence of equivalence ratio on above findings is found to be insignificant, indicating that although the local reactivity of turbulent premixed cool flames is altered due to the differential diffusion, the resultant flame- stretch interaction is insensitive to the equivalence ratio. This study presents some unique cool flame dynamics that are distinct from hot flames, which can help improve the understanding and modeling of turbulent cool flames.

Cool flames

Integrated-photonics-based systems for polarization-gradient cooling of trapped ions

Trapped ions are a promising modality for quantum systems, with demonstrated utility as the basis for quantum processors and optical clocks. However, traditional trapped-ion systems are implemented using complex free-space optical configurations, whose large size and susceptibility to vibrations and drift inhibit scaling to large numbers of qubits. In recent years, integrated-photonics-based systems have been demonstrated as an avenue to address the challenge of scaling trapped-ion systems while maintaining high fidelities. While these previous demonstrations have implemented both Doppler and resolved-sideband cooling of trapped ions, these cooling techniques are fundamentally limited in efficiency. In contrast, polarization-gradient cooling can enable faster and more power-efficient cooling and, therefore, improved computational efficiencies in trapped-ion systems. While free-space implementations of polarization-gradient cooling have demonstrated advantages over other cooling mechanisms, polarization-gradient cooling has never previously been implemented using integrated photonics. In this paper, we design and experimentally demonstrate key polarization-diverse integrated-photonics devices and utilize them to implement a variety of integrated-photonics-based polarization-gradient-cooling systems, culminating in the first experimental demonstration of polarization-gradient cooling of a trapped ion by an integrated-photonics-based system. By demonstrating polarization-gradient cooling using an integrated-photonics-based system and, in general, opening up the field of polarization-diverse integrated-photonics-based devices and systems for trapped ions, this work facilitates new capabilities for integrated-photonics-based trapped-ion platforms.

atom optics