Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONTRAST MEDIA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Post-Flight Microbial Analysis of Samples from the International Space Station Water Recovery System and Oxygen Generation System

The Regenerative, Environmental Control and Life Support System (ECLSS) on the International Space Station (ISS) includes the the Water Recovery System (WRS) and the Oxygen Generation System (OGS). The WRS consists of a Urine Processor Assembly (UPA) and Water Processor Assembly (WPA). This report describes microbial characterization of wastewater and surface samples collected from the WRS and OGS subsystems, returned to KSC, JSC, and MSFC on consecutive shuttle flights (STS-129 and STS-130) in 2009-10. STS-129 returned two filters that contained fluid samples from the WPA Waste Tank Orbital Recovery Unit (ORU), one from the waste tank and the other from the ISS humidity condensate. Direct count by microscopic enumeration revealed 8.38 x 104 cells per mL in the humidity condensate sample, but none of those cells were recoverable on solid agar media. In contrast, 3.32 x lOs cells per mL were measured from a surface swab of the WRS waste tank, including viable bacteria and fungi recovered after S12 days of incubation on solid agar media. Based on rDNA sequencing and phenotypic characterization, a fungus recovered from the filter was determined to be Lecythophora mutabilis. The bacterial isolate was identified by rDNA sequence data to be Methylobacterium radiotolerans. Additional UPA subsystem samples were returned on STS-130 for analysis. Both liquid and solid samples were collected from the Russian urine container (EDV), Distillation Assembly (DA) and Recycle Filter Tank Assembly (RFTA) for post-flight analysis. The bacterium Pseudomonas aeruginosa and fungus Chaetomium brasiliense were isolated from the EDV samples. No viable bacteria or fungi were recovered from RFTA brine samples (N= 6), but multiple samples (N = 11) from the DA and RFTA were found to contain fungal and bacterial cells. Many recovered cells have been identified to genus by rDNA sequencing and carbon source utilization profiling (BiOLOG Gen III). The presence of viable bacteria and fungi from WRS and OGS subsystems demonstrates the need for continued monitoring of ECLSS during future ISS operations and investigation of advanced antimicrobial controls.

Birmele, Michele N.↗

Tip-growing cells of the moss Ceratodon purpureus Are gravitropic in high-density media

Gravity sensing in plants and algae is hypothesized to rely upon either the mass of the entire cell or that of sedimenting organelles (statoliths). Protonemata of the moss Ceratodon purpureus show upward gravitropism and contain amyloplasts that sediment. If moss sensing were whole-cell based, then media denser than the cell should prevent gravitropism or reverse its direction. Cells that were inverted or reoriented to the horizontal displayed distinct negative gravitropism in solutions of iodixanol with densities of 1.052 to 1.320 as well as in bovine serum albumin solutions with densities of 1.037 to 1.184 g cm(-3). Studies using tagged molecules of different sizes and calculations of diffusion times suggest that both types of media penetrate through the apical cell wall. Estimates of the density of the apical cell range from 1.004 to 1.085. Because protonemata grow upward when the cells have a density that is lower than the surrounding medium, gravitropic sensing probably utilizes an intracellular mass in moss protonemata. These data provide additional support for the idea that sedimenting amyloplasts function as statoliths in gravitropism.

NASA Discipline Plant Biology↗

Contrast and harmonic imaging improves accuracy and efficiency of novice readers for dobutamine stress echocardiography

BACKGROUND: Newer contrast agents as well as tissue harmonic imaging enhance left ventricular (LV) endocardial border delineation, and therefore, improve LV wall-motion analysis. Interpretation of dobutamine stress echocardiography is observer-dependent and requires experience. This study was performed to evaluate whether these new imaging modalities would improve endocardial visualization and enhance accuracy and efficiency of the inexperienced reader interpreting dobutamine stress echocardiography. METHODS AND RESULTS: Twenty-nine consecutive patients with known or suspected coronary artery disease underwent dobutamine stress echocardiography. Both fundamental (2.5 MHZ) and harmonic (1.7 and 3.5 MHZ) mode images were obtained in four standard views at rest and at peak stress during a standard dobutamine infusion stress protocol. Following the noncontrast images, Optison was administered intravenously in bolus (0.5-3.0 ml), and fundamental and harmonic images were obtained. The dobutamine echocardiography studies were reviewed by one experienced and one inexperienced echocardiographer. LV segments were graded for image quality and function. Time for interpretation also was recorded. Contrast with harmonic imaging improved the diagnostic concordance of the novice reader to the expert reader by 7.1%, 7.5%, and 12.6% (P < 0.001) as compared with harmonic imaging, fundamental imaging, and fundamental imaging with contrast, respectively. For the novice reader, reading time was reduced by 47%, 55%, and 58% (P < 0.005) as compared with the time needed for fundamental, fundamental contrast, and harmonic modes, respectively. With harmonic imaging, the image quality score was 4.6% higher (P < 0.001) than for fundamental imaging. Image quality scores were not significantly different for noncontrast and contrast images. CONCLUSION: Harmonic imaging with contrast significantly improves the accuracy and efficiency of the novice dobutamine stress echocardiography reader. The use of harmonic imaging reduces the frequency of nondiagnostic wall segments.

Non-NASA Center↗

New imaging technology: measurement of myocardial perfusion by contrast echocardiography

Myocardial perfusion imaging has long been a goal for the non-invasive echocardiographic assessment of the heart. However, many factors at play in perfusion imaging have made this goal elusive. Harmonic imaging and triggered imaging with newer contrast agents have made myocardial perfusion imaging potentially practical in the very near future. The application of indicator dilution theory to the coronary circulation and bubble contrast agents is fraught with complexities and sources of error. Therefore, quantification of myocardial perfusion by non-invasive echocardiographic imaging requires further investigation in order to make this technique clinically viable.

NASA Program Biomedical Research and Countermeasur↗

Micro-Horn Arrays for Ultrasonic Impedance Matching

Thin-layered structures containing arrays of micromachined horns, denoted solid micro-horn arrays (SMIHAs), have been conceived as improved means of matching acoustic impedances between ultrasonic transducers and the media with which the transducers are required to exchange acoustic energy. Typically, ultrasonic transducers (e.g., those used in medical imaging) are piezoelectric or similar devices, which produce small displacements at large stresses. However, larger displacements at smaller stresses are required in the target media (e.g., human tissues) with which acoustic energy is to be exchanged. Heretofore, efficiencies in transmission of acoustic energy between ultrasonic transducers and target media have been severely limited because substantial mismatches of acoustic impedances have remained, even when coupling material layers have been interposed between the transducers and the target media. In contrast, SMIHAs can, in principle, be designed to effect more nearly complete acoustic impedance matching, leading to power transmission efficiencies of 90 percent or even greater. The SMIHA concept is based on extension, into the higher-frequency/ lower-wavelength ultrasonic range, of the use of horns to match acoustic impedances in the audible and lower-frequency ultrasonic ranges. In matching acoustic impedance in transmission from a higher-impedance acoustic source (e.g., a piezoelectric transducer) and a lowerimpedance target medium (e.g., air or human tissue), a horn acts as a mechanical amplifier. The shape and size of the horn can be optimized for matching acoustic impedance in a specified frequency range. A typical SMIHA would consist of a base plate, a face plate, and an array of horns that would constitute pillars that connect the two plates (see figure). In use, the base plate would be connected to an ultrasonic transducer and the face plate would be placed in contact with the target medium. As at lower frequencies, the sizes and shapes of the pillars could be tailored for impedance matching in a specified ultrasonic frequency range. In a design that would be simplest to implement by micromachining, the horns would have constant cross-sectional areas as shown in the upper part of the figure. In this case, the dimensions of the horns could be chosen on the basis of a Mason equivalent-circuit model (a simplified model, well-known in the piezoelectric-transducer art, in which the electrical and mechanical dynamics, including electromechanical couplings, are expressed as electrical circuit elements that can include inductors, capacitors, and lumped-parameter complex impedances.) In a more complex, more nearly optimum design, the cross-sectional area of each horn would be either stepped or made to vary as a continuous function of through-the thickness position, as shown in the lower part of the figure.

Rao, Shanti↗

Bioreactor perfusion system for the long-term maintenance of tissue-engineered skeletal muscle organoids

Three-dimensional skeletal muscle organ-like structures (organoids) formed in tissue culture by fusion of proliferating myoblasts into parallel networks of long, unbranched myofibers provide an in vivo-like model for examining the effects of growth factors, tension, and space flight on muscle cell growth and metabolism. To determine the feasibility of maintaining either avian or mammalian muscle organoids in a commercial perfusion bioreactor system, we measured metabolism, protein turnover. and autocrine/paracrine growth factor release rates. Medium glucose was metabolized at a constant rate in both low-serum- and serum-free media for up to 30 d. Total organoid noncollagenous protein and DNA content decreased approximately 22-28% (P < 0.05) over a 13-d period. Total protein synthesis rates could be determined accurately in the bioreactors for up to 30 h and total protein degradation rates could be measured for up to 3 wk. Special fixation and storage conditions necessary for space flight studies were validated as part of the studies. For example, the anabolic autocrine/paracrine skeletal muscle growth factors prostaglandin F2alpha (PGF2alpha) and insulin-like growth factor-1 (IGF-1) could be measured accurately in collected media fractions, even after storage at 37 degrees C for up to 10 d. In contrast, creatine kinase activity (a marker of cell damage) in collected media fractions was unreliable. These results provide initial benchmarks for long-term ex vivo studies of tissue-engineered skeletal muscle.

NASA Discipline Musculoskeletal↗

Plating isolation of various catalase-negative microorganisms from soil

A unique plating procedure was developed that allows isolation, but not enumeration, of representatives of the catalase-negative soil microflora. The numbers recovered, however, are low as compared to the numbers recovered when the modified dilution-to-extinction isolation procedure is used. The latter procedure provides prolonged inoculation in sealed tubes containing a nutritionally rich broth medium over small submerged agar slants. In contrast, the plating procedure utilizes nutritionally minimal media and the shorter incubations mandated by the inherent problems associated with plating.

Labeda, D. P.↗

Objective appraisal of tolerance to ventriculography with various radiocontrast media (according to electronystagmography data)

The vestibulo oculomotor reflex (nystagmus) was recorded by means of electronystagmography in 33 neurosurgical patients in dynamics prior to and after ventriculography. For contrasting the ventricular system a water soluble medium (Conrey, dimer X or Amipak) was used in 18 patients and contrast mixtures of water soluble agents in combination with Myodil emulsion in 15. It was established that after ventriculography with water soluble media the trunk vestibular reactions in all types of nystagmus grew frequently and sharply and the vestibulovegetative reactions increased markedly.

Blagoveshchenskaya, N. S.↗

Cultured rat vascular smooth muscle cells are resistant to methylamine toxicity: no correlation to semicarbazide-sensitive amine oxidase

Methylamine (MA), a component of serum and a metabolite of nicotine and certain insecticides and herbicides, is metabolized by semicarbazide-sensitive amine oxidase (SSAO). MA is toxic to cultured human umbilical vein and calf pulmonary artery endothelial cells. Endothelial cells, which do not exhibit endogenous SSAO activity, are exposed to SSAO circulating in serum. In contrast, vascular smooth muscle cells (VSMC) do exhibit innate SSAO activity both in vivo and in vitro. This property, together with the critical localization of VSMC within the arterial wall, led us to investigate the potential toxicity of MA to VSMC. Cultured rat VSMC were treated with MA (10-5 to 1 M). In some cultures, SSAO was selectively inhibited with semicarbazide or MDL-72145 [(E)-2-(3,4-dimethoxyphenyl)-3-fluoroallylamine]. Cytotoxicity was measured via MTT, vital dye exclusion, and clonogenic assays. MA proved to be toxic to VSMC only at relatively high concentrations (LC(50) of 0.1 M). The inhibition of SSAO with semicarbazide or MDL-72145 did not increase MA toxicity, suggesting that the production of formaldehyde via tissue-bound, SSAO-mediated MA metabolism does not play a role in the minimal toxicity observed in isolated rat VSMC. The omission of fetal calf serum (FCS), which contains high SSAO activity, from media similarly showed little effect on cytotoxicity. We conclude that VSMC--in contrast to previous results in endothelial cells--are relatively resistant to MA toxicity, and SSAO does not play a role in VSMC injury by MA.

Amine Oxidase (Copper-Containing)/metabolism↗

Increased Arginine and Ornithine Flux in Islets of Langerhans Cultured in a Microgravity Model System

Microgravity is associated with alterations in protein metabolism of both muscle and bone. That pancreas-derived insulin is essential to the normal maintenance of body protein balance is well known. The importance of altered endocrine pancreas function in microgravity is not yet established. We proposed to examine the influence of a microgravity model system, the High Aspect Ratio Vessel (HARV) upon islets of Langerhans from Wistar Furth rats. Islets were cultured in the HARV for 48 hr in Medium-199 and contrasted to static control islets (PLATE). Nitrogenous compounds elaborated into the media (micromoles/ml) were analyzed at 0 and 48 hr of culture and compared to PLATE with a 2-way ANOVA (HARV vs Hour).

Tobin, B. W.↗

Detection of Pollution Caused by Solid Wastes

To develop a means of detecting pollution, it s necessary to know something about the source and nature of the pollution. The type of pollution rising from solid wastes differs considerably from hat from liquid wastes or that from gaseous wastes ni its effect on the immediate environment. It may be "defined" by a series of negatives. When solid wastes are discarded on land, the resulting pollution is not land pollution in the sense of air and water pollution. For one thing, the solid wastes do not become a "part" of the land in that the wastes are neither intimately mixed nor homogenized into the land as are liquid and gaseous wastes into their respective media. The waste particles retain not only their chemical identity but also their visible (i.e., physical) characteristics. When buried, for example, the soil is under, above, and around the solids, because the wastes are there as discrete units. Secondly, solid wastes neither diffuse nor are they carried from the place at which they were deposited. In other words they remain stationary, providing of course the disposal site is land and not moving water. In a given area, solid wastes be not distributed uniformly over that area. Even the solid wastes falling into the specification of letter meets these specifications. In contrast liquid and gaseous wastes become intimately mixed, homogenized, and even dissolved in their media. Because solid wastes remain stationary, pollution constituted by their presence is highly localized and heavily concentrated, even to the extent that the pollution could be termed "micro" when compared to the macro-pollution arising from liquid and gasequs wastes.

Golueke, Clarence G.↗

Carbon Nanotube Anodes Being Evaluated for Lithium Ion Batteries

The NASA Glenn Research Center is evaluating the use of carbon nanotubes as anode materials for thin-film lithium-ion (Li) batteries. The motivation for this work lies in the fact that, in contrast to carbon black, directed structured nanotubes and nanofibers offer a superior intercalation media for Li-ion batteries. Carbon lamellas in carbon blacks are circumferentially oriented and block much of the particle interior, rendering much of the matrix useless as intercalation material. Nanofibers, on the other hand, can be grown so as to provide 100-percent accessibility of the entire carbon structure to intercalation. These tubes can be visualized as "rolled-up" sheets of carbon hexagons (see the following figure). One tube is approximately 1/10,000th the diameter of a human hair. In addition, the high accessibility of the structure confers a high mobility to ion-exchange processes, a fundamental for the batteries to respond dynamically because of intercalation.

Raffaelle, Ryne P.↗

Two-Layer, Full-Color Electroluminescent Display

Full-color, matrix-addressed electroluminescent display uses three different color phosphors located in two separate, superimposed layers to provide higher brightness, better contrast ratio, and higher resolution. Design used for such transparent, flat-panel display media as thin-film electroluminescent phosphors, liquid crystals, or light-emitting diodes.

Robertson, J. B.↗

Note on the forward-scatter approximation

An asymptotic expansion in inverse powers of the wave number is derived for an integral of a type often encountered in the theory of wave propagation in inhomogeneous media. The procedure, which is essentially a forward-scatter approximation, yields all the terms of the expansion. In contrast, the conventional forward-scatter approximation is found to yield correctly only the first term of the expansion.

Wenzel, A. R.↗

Seismic Study of the Dynamics of the Solar Subsurface from SoHO Observations

In collaboration with Dr. Baudin, we have developed and refined the new observational methodology for local helioseismology known as time-distance analysis. Global helioseismology study the solar oscillations as a superposition of resonant modes, whose properties (mode frequencies) reflect the global structure of the sun (sound speed stratification, rotation rate, etc). In contrast, local helioseismology look at the solar oscillations as wave packets whose propagation will be affected by perturbations of the media sampled. These local perturbations (sound speed or velocity flows) will modify the propagation time, that in turn can be used as a diagnostic tool for a given region. From a data reduction perspective, the processing of solar dopplergrams that result in time-distance maps, i.e. propagation times as a function of distance between bounces at the surface, is radically different from the methodology used for global mode analysis. We have, in a first step, further develop the programs needed to carry out such analysis. We have then applied them to NMI data set, and explore the trade-off between various averaging and filtering approaches - steps required to improve the signal-to-noise ratio of correlation maps - and the resulting stability and precision of the fitted propagation times. While excessive averaging (whether over space, propagation distance, or time) will reduce the diagnostic potential of the method, insufficient averaging lead to unstable fits, or uncertainties so large as to hide the information we seek. In a second phase, we have developed the analysis methodology required to infer local properties from perturbation in time propagation. Namely, we have developed time-distance inversion techniques, with an emphasis on inferences of velocity flows from time anomalies. Note also that during the period covered by this grant, all the investigators on this proposal (i.e., Drs. Baudin, Eff-Darwich, Korzennik, and Noyes) took part in the organization of the SOHO 6 /GONG 99 Workshop: Structure and Dynamics of the Interior of the Sun and Sunlike Stars, held on June 1-4 1999 at the Boston Park Plaza Hotel in Boston, Massachusetts, USA. it was very well attended by more than 160 participants from 26 countries from all over the world. The proceedings were published in two volumes as ESA SP-418, with Sessions I-III in Volume 1, and Sessions IV-VI in Volume 2 (1,000 pages in total). The complete contents are also included in digital form on a CD-ROM included with Volume 1. This CD-ROM also contains additional multi-media material that complements some of the contributions.

Korzennik, Sylvain G.↗

Evaluation of various cleaning methods to remove bacillus spores from spacecraft hardware materials

A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. Metal coupons (1 cm x 2.5 cm) were precleaned and inoculated with 5.8 x 10(3) cultivable Bacillus subtilis spores, which are commonly found on spacecraft surfaces and in the assembly environments. The inoculated coupons were subsequently cleaned using: (1) 70% isopropyl alcohol wipe; (2) water wipe; (3) multiple-solvent flight-hardware cleaning procedures used at the Jet Propulsion Laboratory (JPL); (4) Johnson Space Center-developed ultrapure water rinse; and (5) a commercial, semi-aqueous, multiple-solvent (SAMS) cleaning process. The biological cleaning effectiveness was measured by agar plate assay, sterility test (growing in liquid media), and epifluorescent microscopy. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.

Spores, Bacterial/metabolism↗

Prolactin variants in ram adenohypophyses vary with season

Secretion of PRL in sheep is affected by photoperiod being highest during the spring and summer, lowest in fall and winter. The objectives of this study were to determine if 1) the production of variant forms of PRL, and 2) immuno- and bioactivities of PRL (iPRL and bPRL) differ during times of the year selected to represent periods of low, transitional and high PRL secretion. Twelve mature rams were maintained on pasture and killed in October, December, and April (n = 4/month). Individual pituitary glands were dispersed, cells obtained, and fixed for immunocytochemical flow cytometry, extracted with 0.01 N NaHCO3 or cultured in serum-free, defined media. The Mr of PRL extracted from cells immediately following dispersion ranged from 14-140K, with significantly more bands greater than 40K being detected from rams sacrificed in December than from those killed in October and April (P less than 0.01). No bands of PRL greater than 25K were observed when samples were reduced with beta-mercaptoethanol prior to electrophoresis, indicating that the high Mr forms were disulfide-linked aggregates. Culture media from October and April contained variants of PRL that ranged from 22-40K but those greater than 25K were generally not observed from cells harvested during December. Extracts of cells after 24 h in culture contained fewer high Mr species during December than had been present in initial extracts from that month. In contrast, during April more high Mr intracellular forms were present after culture than had been detected prior to culture during that month. The percentage of lactotrophs averaged 50.0 +/- 2.5, 47.4 +/- 5.7, and 59.4 +/- 5.5 for October, December, and April, respectively. Initial lactotroph content (pg/lactotroph) of iPRL was higher (P = 0.06) in April (46.0 +/- 17.0) when compared to October and December (8.0 +/- 2.0 and 20.0 +/- 10.0, respectively). In contrast, the bPRL content of initial extracts was higher (P = 0.05) in December (267.0 +/- 68.0) than in October (101.0 +/- 35.0), but not than in April (190.0 +/- 70.0). Although iPRL and bPRL concentrations in culture media were similar for the 3 months, the intracellular iPRL (P less than 0.001) and bPRL (P less than 0.0001) content after culture was greatest during April. In summary, in addition to the well-documented seasonal changes in blood concentrations of PRL, different molecular forms of PRL were found within the pituitary at different times of the year and seasonal variations in iPRL and bPRL did not occur in parallel.

Non-NASA Center↗

Growth of Three Lettuce Cultivars in NASA's HDU PEM During the 2010 DRATS Test

NASA's 2010 Desert Research and Technology Studies (DRATS) of the VEGGIE Food Production System in the Habitat Demonstration Unit (HDU) Pressurized Excursion Module (PEM) was the first operational evaluation of salad crop production technology in a NASA analog test. Rooting media and slow release fertilizers were evaluated for three lettuce cultivars that had shown promise as candidates for a surface based food production system. These tests involved comparing growth, color and quality of the lettuce cultivars grown under VEGGIE LED array (Orbitec, Madison, WI) or Biomass Production System for Education ((BSEe), Orbitec, Madison, WI) compact fluorescent lamps using a gravity feed water delivery system. Mission relevant conditions of CO2, temperature and RH were maintained using controlled environment chambers (EGC, Chagrin Falls, OH). Growth data was obtained for the two red leaf lettuce cultivars, Outredgeous and Firecracker, and the green Bibb lettuce cultivar, Flandria. Growth and quality was evaluated using different concentrations (7.5 g/L and 15 g/L) of commercial slow release fertilizer (Osmocote Plus 15-9-12, Scotts, Maryville, OH) and Nutricote 18-6-8 (Florikan, Sarasota, FL) in either a peat/vermiculite media (sunshine LP5 MiX, Sungro, Bellview, WA) or calcined montmorillonite clay [(arcillite,)Turface Proleague, Profile LLC, Buffalo Grove, IL]. The commercial peat/vermiculite mix generally resulted in larger plants than those grown in arcillite. Increasing the concentration of Osmocote from 7.5 to 15 g/L increased the height, dry mass, and leaf area of lettuce cultivars. In contrast, there was a decrease in growth parameters when concentration of Nutricote was increased from 7.5 to 15 g/L. The best growth was obtained with the 7.5 g/L Nutricote using a commercial peat/vermiculite mixture. This media was used for field testing VEGGIE plant system in the 2010 DRAT test. The VEGGIE nutrient delivery system worked well, was able to be maintained by multiple operators with a minimum of training, and supported excellent lettuce growth for the duration of the 14-day test. The operational DRAT field testing in the HDU identified light quality issues related to morphology and pigment development that will need to be addressed through additional testing. Feedback from the crew, ground support personnel, and human factors leads was uniformly positive on the psychological value of having the crop production system in the pressurized excursion module. Data are being used to design a plant atrium with LED lighting to evaluate salad crop growth during NASA's 2011 DRATS test.

Stutte, Gary W.↗