Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONFIGURATION CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Software and Firmware-logic Design for the PIP-II Machine Protection System Mode and Configuration Control at Fermilab

The PIP-II Machine Protection System (MPS) requires a dedicated set of tools for configuration control and management of the machine modes and beam modes of the accelerator. The protection system reacts to signals from various elements of the machine according to rules established in a setup database in the form of a Look-Up-Table filtered by the program Mode Controller. This is achieved in accordance with commands from the operator and governed by the firmware logic of the MPS. This paper describes the architecture, firmware logic, and implementation of the program mode controller.

43 PARTICLE ACCELERATORS↗

Reticular Structural Diversification of Zirconium Metal–Organic Frameworks Through Angular Ligand Configuration Control

Reticular chemistry offers practical guidelines for enlarging and enriching the arsenal of metal–organic frameworks (MOFs). However, reticular expansion to access mesoporous structures remains challenging due to limitations in achieving precise control over both the size and configuration during building units’ extension. Herein, we combine ligand isomerization and functionalization strategies to regulate the ligand configuration by systematically replacing aryl C–H groups with N atoms, resulting in angular dicarboxylate ligands with various symmetries. The assembly between a 4,4′-(pyridine-2,6-diyl)dibenzoic acid ligand (1N, C 2 symmetry) and 12-connected Zr 6 cluster leads to the formation of a pseudo ftw topology framework (NU-2611), where one pair of nose-to-nose 1N ligands resembles a tetra-topic ligand. When a 6,6′-(1,3-phenylene)dinicotinic acid ligand (2N, C S symmetry) was used, another pseudo ftw network NU-2612 was obtained with a 2-fold framework interpenetration. Interestingly, the planar [2,2′:6′,2″-terpyridine]-5,5″-dicarboxylic acid ligand (3N, C 2V symmetry) yielded an intriguing mesoporous Zr-MOF with kag topology. NU-2613 represents the first example of kag Zr-MOF designed to include large, well-defined mesopores. The diversity of these MOFs was further enhanced through post-synthetic metalation of linkers. Particularly, metalation of the chelating 3N ligand with Fe 3+ in NU-2613 enables efficient catalytic transformation within the functionalized channels. This work contributes insight into the reticular expansion of Zr-MOFs by finely-tuning the ligand planarity, advancing the structure diversification of mesoporous frameworks for specific applications.

Cluster chemistry↗

Techno-economic evaluation of emission control configurations for AMP/PZ-based post-combustion CO 2 capture

Minimizing the environmental impacts of amine-based post-combustion carbon capture technologies is essential for regulatory compliance and public acceptance. Experimental campaigns at RWE's CO 2 capture pilot plant in Niederaussem using CESAR1 demonstrated that combining existing emission abatement technologies can substantially reduce the concentration of amines and degradation products in the CO 2 -depleted flue gas to below the detection limit of an infrared spectrometer. The campaign confirmed that a proprietary dry bed technology (OEASE aerozone™) or a second water wash can reduce AMP and PZ emissions to below 1 mg/Nm 3 . However, an acid or chemically active wash downstream of the water wash is necessary to reduce NH 3 emissions to very low levels (<2 mg/Nm 3 ). Combining a dry bed with an acid wash significantly reduces both the required acid solution and the resulting acid waste. The techno-economic analysis indicates that implementing emission mitigation technologies provides substantial environmental benefits for the CESAR1 process, with only a marginal increase (<1 €/tCO 2 ) in both the carbon capture cost (CCC) and CO 2 avoidance cost (CAC). The additional capital cost associated with extra column packing is offset by operational cost savings from reduced solvent losses. For stringent emission permits targeting NH 3 , a configuration combining a dry bed upstream of the water wash followed by an acid wash achieves the best balance between emission control and cost efficiency. This configuration results in a Levelized Cost of Electricity (LCOE) of 143 €/MWh, a CCC of 45.4 €/tCO 2 , and a CAC of 88.4 €/tCO 2 .

AMP↗

Local Atomic Configuration Control of Superconductivity in the Undoped Pnictide Parent Compound BaFe 2 As 2

Emergent superconductivity is strongly correlated with the symmetry of local atomic configuration in the parent compounds of iron-based superconductors. While chemical doping or hydrostatic pressure can change the local geometry, conventional approaches do not provide a clear pathway in predictably tuning the detailed atomic arrangement due to the parent compound’s complicated structural deformation in the presence of the tetragonal-to-orthorhombic phase transition. Here, we demonstrate a systematic approach to manipulate local structural configurations in BaFe 2 As 2 epitaxial thin films by controlling two independent structural factors, orthorhombicity (in-plane anisotropy) and tetragonality (out-of-plane/in-plane balance), from lattice parameters. We tune superconductivity without doping utilizing both structural factors separately and controlling local tetrahedral coordination in the designed thin film heterostructures with substrate clamping and biaxial strain. We further show this allows quantitative control of the structural phase transition, the associated magnetism, and superconductivity in parent material BaFe 2 As 2 . Furthermore, this approach will advance the development of tunable thin film superconductors in a reduced dimension.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Kirigami Engineering—Nanoscale Structures Exhibiting a Range of Controllable 3D Configurations

Abstract Kirigami structures provide a promising approach to transform flat films into 3D complex structures that are difficult to achieve by conventional fabrication approaches. By designing the cutting geometry, it is shown that distinct buckling‐induced out‐of‐plane configurations can be obtained, separated by a sharp transition characterized by a critical geometric dimension of the structures. In situ electron microscopy experiments reveal the effect of the ratio between the in‐plane cut size and film thickness on out‐of‐plane configurations. Moreover, geometrically nonlinear finite element analyses (FEA) accurately predict the out‐of‐plane modes measured experimentally, their transition as a function of cut geometry, and provide the stress–strain response of the kirigami structures. The combined computational–experimental approach and results reported here represent a step forward in the characterization of thin films experiencing buckling‐induced out‐of‐plane shape transformations and provide a path to control 3D configurations of micro‐ and nanoscale buckling‐induced kirigami structures. The out‐of‐plane configurations promise great utility in the creation of micro‐ and nanoscale systems that can harness such structural behavior, such as optical scanning micromirrors, novel actuators, and nanorobotics. This work is of particular significance as the kirigami dimensions approach the sub‐micrometer scale which is challenging to achieve with conventional micro‐electromechanical system technologies.

Zhang, Xu↗

Flexible Operation of Microgrids Through Operator-Configurable Microgrid Controllers

Microgrids are becoming critical assets in power distribution systems. This is partly due to the resiliency and reliability challenges faced by power distribution systems in the last decade and partly due to the increased integration of distributed energy resource assets, such as solar photovoltaic. This increased need for microgrids has created a multitude of needs for microgrid controllers. Most microgrid controllers in the past decade have been uniquely programmed or custom programmed to meet the needs of a specific microgrid. Currently, IEEE standards aim to integrate the needs and capabilities of microgrid controllers under a unified umbrella. But the standards do not recommend necessary or appropriate software development practices for microgrid controllers. In addition, the programmable nature and maintenance of controllers are also key characteristics that fall outside the coverage of the standards. In this paper, we present the best software practices that utility engineers and microgrid operators should consider in the microgrid software platform. This paper can be used as an information document for developing documentation of controller requirements and assessing microgrid controller requirements.

Banshee microgrid↗

System Health and Status Reporting is Used to Improve Infrastructure Systems at the Hanford Site - 20449

Reliable physical infrastructure systems are vital to completing the clean-up mission and the start-up and commissioning of new nuclear waste processing facilities at the Hanford Site. Key infrastructure systems at Hanford include water, sewer, and electrical utilities, roads, telecommunications/network systems, and fire systems. All of the infrastructure systems are non-nuclear, General Service systems that are being maintained under formal engineering configuration control and none are specifically credited in any documented safety analysis (DSA). Starting in calendar year 2017, the Hanford Site's infrastructure and services contractor started producing system health and status reports for a total of 15 critical infrastructure systems as means to get a better understanding of each system's health and how it could be improved to ensure better and more reliable service delivery. As the reporting, tracking, and use of the metrics has matured, the number of systems for which reports are being developed has been expanded to a total of 23. Each of the critical infrastructure systems are assigned primary and alternate design authorities that complete qualifications on each assigned system. The design authorities actively manage and maintain configuration control on each of their systems and track metrics associated with availability, maintenance (corrective and preventive), and configuration of the technical baseline. The metrics are based on the principles established in Chapter V of DOE O 420.1C, Facility Safety, [1] and have been tailored as appropriate to each of the key infrastructure systems. An overall assessment of system health is performed and documented on a routine basis (e.g., quarterly). Included in this documentation is a quantitative score for each of the metrics (i.e., availability, maintenance, configuration management) along with results of system walk-downs, description of any permanent design modifications, identification of new or emerging issues and vulnerabilities affecting the system, and an assessment by the design authority of actions necessary to improve the system health score. The overall status scores are calculated using a formula and based on a pre-determined grading scale, a color is assigned for simple presentation. The information gained from developing the reports is being used to (1) assist with making timely and better informed decisions through the use of solid technical bases that are increasing the overall reliability and capabilities of the Site's infrastructure systems as new expense and capital projects in the Reliability Projects Investment Portfolio (RPIP) are prioritized and executed; (2) feed the risk management program, and (3) integrate the technical content of Master Plans that describe the Site's needs for the system and the system's capabilities to meet those future needs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Controlling magnetic configuration in soft–hard bilayers probed by polarized neutron reflectometry

Hard/soft magnetic bilayer thin films have been widely used in data storage technologies and permanent magnet applications. The magnetic configuration and response to temperatures and magnetic fields in these heterostructures are considered to be highly dependent on the interfacial coupling. However, the intrinsic properties of each of the layers, such as the saturation magnetization and layer thickness, also strongly influence the magnetic configuration. Changing these parameters provides an effective method to tailor magnetic properties in composite magnets. Here, we use polarized neutron reflectometry (PNR) to experimentally probe the interfacial magnetic configurations in the hard/soft bilayer thin films: L1 0 -FePt/A1-FePt, [Co/Pd]/CoPd, [Co/Pt]/FeNi, and L1 0 -FePt/Fe, all of which have a perpendicular magnetic anisotropy in the hard layer. These films were designed with different soft and hard layer thicknesses (t soft and t hard ) and saturation magnetization (M$_s^{soft}$ and M$_s^{hard}$). The influences of an in-plane magnetic field (H ip ) and temperature (T) are also studied using a L1 0 -FePt/A1-FePt bilayer sample. Comparing the PNR results to the micromagnetic simulations reveals that the interfacial magnetic configuration is highly dependent on t soft , M$_s^{soft}, and the external factors (H ip and T) and has a relatively weak dependence on t hard and M$_s^{hard}$. Key among these results, for thin t soft , the hard and soft layers are rigidly coupled in the out-of-plane direction and then undergo a transition to relax in-plane. This transition can be delayed to larger t soft by decreasing M$_s^{soft}$. Understanding the influence of these parameters on the magnetic configuration is critical to designing functional composite magnets for applications.

36 MATERIALS SCIENCE↗

System for fast draining of an airfan heat exchanger and methods of using the same

A system for draining an airfan heat exchanger includes an airfan heat exchanger including a housing, a pressurized gas source fluidly coupled to the airfan heat exchanger and configured to hold a purging gas at a predetermined pressure, and a controller configured to control delivery of the purging gas to the airfan heat exchanger. The pressurized gas source is configured to provide a flow of the purging gas to the airfan heat exchanger and thereby drain water held in the airfan heat exchanger. The purging gas to the airfan will cause the airfan to drain quickly avoiding potential damage to the airfan from freezing of the water during cold weather.

Jahnke, Fred C.↗

Supervisory genset control in range-extended electric vehicle

A controls system for a range-extended electric vehicle comprising an overall system control unit, an engine control module configured to control a range extender of the range-extended electric vehicle, power electronics configured to control a generator of the range-extended electric vehicle, and a supervisory control module coupled between the overall system control unit and the engine control module and the power electronics, the supervisory control module configured to receive information from the overall system control unit and provide commands to the engine control module and the power electronics.

Li, Ke↗

Real-time optimization of multi-cell industrial evaporative cooling towers using machine learning and particle swarm optimization

Existing electrical generating stations must operate with greater flexibility due to increasing renewable energy penetration on the electrical grid, and many coal-fired power stations have transitioned away from baseload operation to load-following operation to aid in grid stability. In cases where multiple independently controlled cooling tower cells are used in parallel for the cooling purposes of such stations, there is an opportunity to increase plant efficiency through data-driven optimization across their full load ranges. This work presents a novel application of real-time optimization using machine learning and particle swarm optimization on a multi-cell induced-draft cooling tower servicing a coal-fired power station under variable load. This is the first work to demonstrate simultaneous optimization of a multi-cell cooling tower, in addition to using machine learning for closed-loop control on a cooling tower. A novel control configuration is presented that ensures original control logic is not adversely affected and that the overall plant process is not disrupted using only existing hardware and operational data. To verify this methodology, the 12 independent cooling tower cells are simulated in parallel using historic operating data to demonstrate the effectiveness of real-time optimization compared to current practice. An artificial neural network is trained to predict overall cooling tower power consumption using only operational data and ambient conditions with an R2 value of greater than 0.96. The real-time optimization using particle swarm yields 6.7% annual energy usage savings compared to current practices, although the extent of the real-time savings varies greatly with both plant load and environmental conditions. This is particularly significant for a variable load situation because frequent ramping typically results in reduced overall efficiency. Furthermore, this proposed AI-based solution presents an opportunity to improve the overall heat rate of a load-following coal-fired power plant without the need to perform extensive first-principles modeling or add additional hardware to the cooling tower, resulting in more resources conserved and less overall emissions per unit of electricity generated.

42 ENGINEERING↗

Extension and Validation of NEMA-Style Dual-Ring Controller in SUMO

Until recently, SUMO users could not model the behavior of a ring-and-barrier traffic signal via existing signal types, which left North American SUMO users without the direct ability to capture traffic dynamics of their local networks. This work presents the methods, implementation overview, and validation of a 'dual-ring' NEMA style traffic controller which has recently been added to the main SUMO code base. A brief explanation of the 'dual-ring' implementation is also provided as context for those new to this type of traffic controller. The foundation for this work was presented at the SUMO User Conference 2021 by researchers at the US Department of Energy's National Renewable Energy Laboratory, but was not integrated into SUMO code base at the time. Following the initial inclusion of the controller to SUMO, the authors began validation of the SUMO controller against an Econolite software-in-the-loop (SIL) traffic signal controller configured with actual setup parameters from controllers in a real-world three-intersection corridor in Tuscaloosa, Alabama, USA. This paper documents the process of adding new features to the controller code as well as validating their implementation through simulation-based and automated grey-box testing is presented in this paper. Key features such as fully-actuated operation, various timing offset plans, proper next-phase fit algorithms and more, have been added and validated against this SIL system. Though not an exhaustive demonstration of features, this work is intended make more users aware of this extension of SUMO capabilities.

MATHEMATICS AND COMPUTING↗

Approach to Quality Assurance for Complex Environmental Modeling - 20407

A strong Quality Assurance (QA) program for complex environmental modeling is essential for regulatory and public acceptance and trust, but it does not have to be onerous. Neptune and Company, Inc. (Neptune) has developed a strong QA program that improves transparency, traceability, reproducibility, and therefore, defensibility and trust. Neptune's QA program has evolved over the past 27 years, transitioning from an ad hoc QA program, to a program that is currently Nuclear Quality Assurance-1 (NQA-1) compliant, and will soon be NQA-1/DOE approved for DOE EM modeling work. In addition, Neptune is a qualified laboratory assessor and qualified auditor for reference materials, a proficiency testing provider, and fully complies with the Environmental Protection Agency (EPA) QA program. Neptune's President and CEO, Kelly Black, was recently named the Chairperson of the International Organization for Standardization (ISO) Technical Committee 69, Application of Statistical Methods. A strong QA program has been developed for Neptune's radiological performance assessment (PA) program. Although pieces of their QA program are currently in development, their current program includes document control using Subversion, issue tracking and work flow tracking using JIRA, and transparency and traceability via a system of 'calc sheets' for documentation of all data analysis and modeling combined with 'check print' documentation of QA checking, and rigorous model testing and configuration control. All work is reviewed by an independent subject matter expert who is not associated with the collection and assembly of information, for an internal peer review. The program is enforced with a handful of Standard Operation Procedures (SOPs), Work Instructions, QA Project Plans (QAPPs), and Quality Management Plans (QMPs) that are updated frequently, with required annual training and acknowledgment. In addition, effective communication of modeling approaches and results to clients and stakeholders are integral to their QA program. Many of their models are built using the GoldSim modeling platform, for which their models are well-known for their level of transparency, documentation, and QA traceability. This level of QA is also applied to their process-level models. Neptune has taken some lessons learned from the extremely rigorous QA program required for the Yucca Mountain Project (YMP), and imposed the YMP requirements of complete traceability, transparency, and reproducibility, but avoided the inflexibility of a QA program that likely contributed to the suspect e-mails in 2005 that resulted in loss of trust in the YMP, and in nuclear waste disposal (and nuclear power) in general. There are far too many examples of loss of public trust due to poor QA that could have been easily avoided with a simple and straight-forward QA program combined with stakeholder engagement. The purpose of this paper is to share features of Neptune's Radiological Performance Assessment program QA program, and some of their QA related lessons learned over the past 27 years of QA for complex environmental modeling. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Synchronized electric meter having an atomic clock

Smart electric meters configured to perform fast, time-synchronized electrical energy measurements at the consumer-level are disclosed herein. In some embodiments, a smart electric meter includes circuitry configured to measure an electrical value at a location of an end user in a power system. The smart electric meter can further include an atomic clock configured to output a timing signal, and a controller configured to receive (a) the measured electrical value from the circuitry and (b) the timing signal from the atomic clock. The controller can further (a) process the electrical value to generate meter data and (b) generate a time tag based on the timing signal. Then, the controller can associate the time tag with the meter data to generate time-tagged meter data.

Min, Liang↗

Steam generator for fuel cell applications

A steam vaporizer assembly includes an internal steam generator having a vessel configured to hold water, a vaporizer unit having a heating element configured to heat the water to generate saturated steam; and a controller configured to: cause the heating element to heat the water to a stand-by temperature; and while maintaining a water level of the water in the vessel between two control points: maintain the water in the vessel at the stand-by temperature until steam generation is required, and when steam generation is required, heating the water in the vessel from the stand-by temperature to a temperature at or above a vaporization temperature of the water using a heating element, to generate the steam.

Dobek, Frank↗

Field evaluation of zone temperature response to control actions in cooling systems of small and medium-sized office buildings

The response of zone temperature to control actions in heating, ventilation, and air conditioning (HVAC) systems, known as zone temperature response, has been a central focus of building control research owing to its crucial role in determining control performance. However, existing studies often overlook the representativeness of the buildings being studied, resulting in unclear generalizations. In addition, those studies tend to focus on a single aspect of the response. Furthermore, this paper provides the first comprehensive characterization of zone temperature response applicable to a clearly defined building sector—small and medium-sized office (SMO) buildings (<5000 m 2 ) in the US. Specifically, two representative SMO buildings, selected based on the US Department of Energy’s commercial prototype buildings, were studied. Field tests were conducted over a 2-month period during summer, and the collected data were analyzed with two key metrics—delay time and nonlinearity index—to quantify zone temperature response, capturing both short- and long-term patterns. Beyond this quantitative characterization, the analysis reveals that the HVAC system type, rather than factors like floor area or zone location, is the primary determinant of the zone temperature response. Drawing on the field test results, we recommend that building control strategies monitor zone temperatures at intervals shorter than 10 minutes, configure controls independently for VAV- and RTU-served zones, and implement nonlinear methods at the zone level—particularly for VAV zones—rather than across the entire building.

Building control↗