Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COINCIDENCE METHODS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Stability and dissociation dynamics of N{sub 2}{sup ++} ions following core ionization studied by an Auger-electron–photoion coincidence method

An Auger-electron–photoion coincidence (AEPICO) method has been applied to study the stability and dissociation dynamics of dicationic states after the N K-shell photoionization of nitrogen molecules. From time-of-flight and kinetic energy analyses of the product ions, we have obtained coincident Auger spectra associated with metastable states of N{sub 2}{sup ++} ions and dissociative states leading to N{sub 2}{sup ++} → N{sup +} + N{sup +} and N{sup ++} + N. To investigate the production of dissociative states, we present two-dimensional AEPICO maps which reveal the correlations between the binding energies of the Auger final states and the ion kinetic energy release. These correlations have been used to determine the dissociation limits of individual Auger final states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The particle-gamma coincidence method: A brief introduction

Excitation energy information from particle detectors can significantly improve the analysis process of {gamma}-ray spectra and result in more detailed nuclear structure information. Therefore, a new setup at the HORUS {gamma}-ray spectrometer at the University of Cologne has been installed, housing silicon particle detectors at up to eight positions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A method for coincidence timing resolution enhancement

A method including the coincidence time resolution improvement for a TOF/positron emission tomography system was suggested. The spectrometer for this aim was composed of two NaI(Tl) and two plastic scintillation detectors. Experimental results were supported by FLUKA Monte Carlo simulation program by constructing the detector setup in software medium. Present experimental results verified our previous results and conclusions obtained from the suggested method. It was concluded that better resolutions would help the improvement not only on the TOF gain but also on the spatial resolution, leading to better images and helping the Physician in his/her diagnosis and treatment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Passive Neutron Instrumentation and Applications

This chapter presents a description of most of the instruments that are currently in use for the measurement of plutonium and uranium using passive methods (without an external source). This includes the acquisition electronics as well as Singles counting methods, coincidence counting methods and multiplicity counting methods. The Singles counting applications include the measurement of waste and curium bearing materials. The coincidence counting applications include bulk plutonium, bulk uranium, waste and holdup measurements and fresh fuel assemblies. The multiplicity application description includes advantages and disadvantages and multiplicity detector design. There is also a description of some non-3He systems. The chapter concludes with a description of additional concepts: neutron imagers, list-mode data analysis, distributed source term analysis, unattended monitoring and MCNP modeling for detector design.

Coincidence shift register↗

The fusion-fission process in the reaction {sup 34}S+{sup 186}W near the interaction barrier

The reaction {sup 34}S+{sup 186}W at E{sub lab}=160 MeV was investigated with the aim of diving into the features of the fusion-fission process. Gamma rays in coincidence with binary reaction fragments were measured using the high efficiency gamma-ray spectrometer ORGAM at the TANDEM Accelerator facility of I.P.N., Orsay, and the time-of-flight spectrometer for fission fragments (FF) registration CORSET of the Flerov Laboratory of Nuclear Reactions (FLNR), Dubna. The coupling of the ORGAM and CORSET setups offers the unique opportunity of extracting details for characterizing the fusion-fission process and gives information regarding production of neutron-rich heavy nuclei. The FF–γ coincidence method is of better use then the γ – γ coincidence method when dealing with low statistic measurements and also offers the opportunity to precisely correct the Dopler shift for in-flight emitted gamma rays. Evidence of symmetric and asymmetric fission modes were observed in the mass and TKE distributions, occurring due to shell effects in the fragments. Coincident measurements allow for discrimination between the gamma rays by accepting a specific range within the mass distribution of the reaction products. Details regarding the experimental setup, methods of processing the acquisitioned data and preliminary results are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the Fast Neutron Response for {sup 4}He Scintillation Detectors Using a Coincidence Scattering Method

Previous work has measured the neutron response of pressurized {sup 4}He scintillation detectors, however these studies only examine the response as a function of incident neutron energy. Since the detection mechanism in {sup 4}He detectors is elastic scattering, and the interacting neutron will only deposit a fraction of its incident kinetic energy in the detector gas, an examination of the response of the detector output to deposited energy is necessary to transform these detectors into instruments for neutron spectrometry. Using a combined time-of-flight (TOF) and coincidence scattering method, this paper further characterizes the {sup 4}He light response to fast neutrons by examining the scintillation light yield as a function of deposited energy, measuring the light response up to 5 MeV. These {sup 4}He detectors are simple in design, and are manufactured by Arktis Radiation Detectors in several sizes. The specific model used in this experiment had an active volume 20 cm long with an inner diameter of 4.4 cm, giving a total active volume of 304 cm{sup 3}. The key components include the active volume, filled with 150 bar of helium-4 gas, and photomultiplier tubes (PMTs) mounted at either end of the active volume. The detector body is made of stainless steel. The detector response was experimentally measured using a two-detector coincidence arrangement with a {sup 252}Cf source. Two {sup 4}He detectors were vertically mounted, and the source was placed at a horizontal distance from the center of the bottom detector, forming a right angle. By requiring coincidence between the two detectors, it was confirmed that each neutron interacting in the second (top) detector must first have undergone a scattering interaction in the first (bottom) detector, and the time-of-flight (TOF) technique could then be used to determine the energy of the neutron as it traveled between the two detectors by the difference in time between the two detector events. More importantly, with the scattering angle known, the amount of energy deposited by the neutron in the bottom detector (ER) was also calculated using kinematic scattering equations. This deposited recoil energy was then compared to the corresponding light output for each event to form a deposited energy scintillation light response matrix. Similarly, the system's insensitivity to gammas and its ability to reject gammas by pulse shape discrimination (PSD) are often cited as an important advantage, although a detailed analysis of these capabilities has not yet been performed. This work therefore quantified these parameters in order to further characterize these detectors for future mixed radiation field measurements. Gamma sources were measured spanning a range of gamma-ray energies from 0.122 MeV to 1.332 MeV, including {sup 57}Co, {sup 137}Cs, {sup 54}Mn, and {sup 60}Co. Each source was counted by the {sup 4}He detector and the background subtracted. Taking the ratio of the number of events detected during the experimental source measurement to the number of gammas predicted by MCNPX to pass through the detector volume yields the detector's intrinsic gamma efficiency. The difference between this fraction and unity is therefore a measure of the detector's ability to ignore interfering gamma rays, defined as its inherent gamma rejection rate. The ability of post-processing PSD algorithms to further reduce the number of gammas is also investigated and quantified. Finally, it has been noted that the scintillation signal from a single neutron event can be separated in time into two components: the fast component is a sharp peak that exists on the order of nanoseconds; the slow component is a series of smaller pulses, stretched out over four microseconds. Whereas previous research has exclusively focused on the energy information contained in the slow component, this work demonstrates that the fast component is also sensitive to neutron energy, and the entire scintillation signal can therefore be used. In conclusion, the relationship of fast neutron {sup 4}He scintillation detectors to deposited neutron energy was explored, and will be combined with previous works that measured the scintillation response to incident neutron energy in order to develop a neutron spectrometer. Similarly, the ability of these {sup 4}He detectors to reject interfering gamma rays was also quantified, and so will enable this spectrometer to be deployed in mixed radiation field measurements. Finally, while previous works with these detectors have focused on an analysis of the slow scintillation component, it was demonstrated in this work that the fast component also contains significant energy information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single, double, and triple Auger decay of the Xe 4p core-hole states

Auger decay of Xe{sup +} states arising from 4p ionization has been studied with a very efficient multielectron coincidence method. Coster-Kronig decay from Xe{sup +} 4p{sup -1} and the subsequent decay into Xe{sup 3+} states with three valence holes are identified. Formation of Xe{sup 4+} is also observed as quadruple coincidences between a 4p photoelectron and three Auger electrons. The relative probabilities of individual multi-ionization processes are determined from the coincidence yields.

74 ATOMIC AND MOLECULAR PHYSICS↗

Development of a coincidence system for the measurement of X-ray emission atomic parameters

Preliminary results obtained in experiments carried out with an x-ray spectrometer built at the Instituto de Fisica for Atomic Physics and environmental sciences studies are presented. The experiments are based on a coincidence method for signals produced by LEGe and Si(Li) detectors. The x-ray fluorescence yields ({omega}{sub Li}) and Coster-Kronig transition probabilities (f{sub ij}) for elements with 55 {<=} Z {<=} 60 are among the quantities of interest. The method is based on the simultaneous detection of K x-rays with the LEGe detector and the L x-rays with the Si(Li) detector. The primary radiation source is an x-ray tube with Rh anode. The system was tested with the coincidence of the L x-rays from Ce with its K line, demonstrating the feasibility of the experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Targeted coherent search for gravitational waves from compact binary coalescences

We introduce a method for conducting a targeted, coherent search for compact binary coalescences. The search is tailored to be used as a follow-up to electromagnetic transients such as gamma-ray bursts. We derive the coherent search statistic for Gaussian detector noise and discuss the benefits of a coherent, multidetector search over coincidence methods. To mitigate the effects of nonstationary data, we introduce a number of signal consistency tests, including the null signal-to-noise ratio, amplitude consistency, and several {chi}{sup 2} tests. We demonstrate the search performance on Gaussian noise and on data from LIGO's fourth science run and verify that the signal consistency tests are capable of removing the majority of noise transients, giving the search an efficiency comparable to that achieved in Gaussian noise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Splitting of the pygmy dipole resonance in {sup 138}Ba and {sup 140}Ce observed in the ({alpha},{alpha}{sup '}{gamma}) reaction

The N=82 nuclei {sup 140}Ce and {sup 138}Ba have been investigated by means of the ({alpha},{alpha}{sup '}{gamma}) coincidence method to study the pygmy dipole resonance (PDR). The experiments have been performed at the AGOR cyclotron at KVI, Groningen, at a primary beam energy of E{sub {alpha}}=136 MeV. The Big-Bite Spectrometer and seven large-volume high-purity germanium detectors were used in coincidence to perform a simultaneous spectroscopy of the scattered {alpha} particles and the {gamma} decay. The comparison with results of nuclear resonance fluorescence experiments reveals a splitting of the PDR into two components. Up to about 6 MeV the same states that could be observed in ({gamma},{gamma}{sup '}) are also excited in {alpha}-scattering experiments, whereas the higher-lying states are missing in the ({alpha},{alpha}{sup '}{gamma}) reaction. This indicates a structural splitting of the PDR into two modes with different underlying structure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Isospin Effects in Heavy-Ion Collisions: Some Results From CHIMERA Experiments At LNS And Perspectives With Radioactive Beams

CHIMERA is a 4{pi} multidetector for charged particles available at Laboratori Nazionali del Sud (INFN-LNS). A new method to measure the time scale of the emission of nuclear fragments is described, together with some applications in the field of the isospin dynamics of heavy-ion collisions. Competition between fusion-like and binary reactions near the energy threshold for nuclear multifragmentation is discussed. Opportunities are pointed out to use the detector at low and intermediate energies using the kinematical-coincidence method.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thoron detection with an active Radon exposure meter—First results

For state-of-the-art discrimination of Radon and Thoron several measurement techniques can be used, such as active sampling, electrostatic collection, delayed coincidence method, and alpha-particle-spectroscopy. However, most of the devices available are bulky and show high power consumption, rendering them unfeasible for personal exposition monitoring. Based on a Radon exposure meter previously realized at the Helmholtz Center Munich (HMGU), a new electronic prototype for Radon/Thoron monitoring is currently being developed, which features small size and weight. Operating with pin-diode detectors, the low-power passive-sampling device can be used for continuous concentration measurements, employing alpha-particle-spectroscopy and coincidence event registration to distinguish decays originating either from Radon or Thoron isotopes and their decay products. In open geometry, preliminary calibration measurements suggest that one count per hour is produced by a 11 Bq m{sup −3} Radon atmosphere or by a 15 Bq m{sup −3} Thoron atmosphere. Future efforts will concentrate on measurements in mixed Radon/Thoron atmospheres.

54 ENVIRONMENTAL SCIENCES↗

A system to measure isomeric state half-lives in the 10 ns to 10 μs range

The Isomeric State Measurement System (SISMEI) was developed to search for isomeric nuclear states produced by fusion-evaporation reactions. The SISMEI consists of 10 plastic phoswich telescopes, two lead shields, one NaI(Tl) scintillation detector, two Compton suppressed HPGe γ-ray detectors, and a cone with a recoil product catcher. The new system was tested at the 8 UD Pelletron tandem accelerator of the University of São Paulo with the measurement of two known isomeric states: {sup 54}Fe, 10{sup +} state (E = 6527.1 (11) keV, T{sub 1/2} = 364(7) ns) and the 5/2{sup +} state of {sup 19}F (E = 197.143 (4) keV, T{sub 1/2} = 89.3 (10) ns). The results indicate that the system is capable of identifying delayed transitions, of measuring isomeric state lifetimes, and of identifying the feeding transitions of the isomeric state through the delayed γ-γ coincidence method. The measured half-life for the 10{sup +} state was T{sub 1/2} = 365(14) ns and for the 5/2{sup +} state, 100(36) ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-energy Neutron-induced Fission Cross Sections of Natural Lead and Bismuth-209

The CERN Neutron Time-Of-Flight (n-TOF) facility is well suited to measure small neutron-induced fission cross sections, as those of subactinides. The cross section ratios of {sup nat}Pb and {sup 209}Bi relative to {sup 235}U and {sup 238}U were measured using PPAC detectors. The fragment coincidence method allows to unambiguously identify the fission events. The present experiment provides the first results for neutron-induced fission up to 1 GeV for {sup nat}Pb and {sup 209}Bi. A good agreement with previous experimental data below 200 MeV is shown. The comparison with proton-induced fission indicates that the limiting regime where neutron-induced and proton-induced fission reach equal cross section is close to 1 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Energy Correlation among Three Photoelectrons Emitted in Core-Valence-Valence Triple Photoionization of Ne

The direct observation of triple photoionization involving one inner shell and two valence electrons is reported. The energy distribution of the three photoelectrons emitted from Ne is obtained using a very efficient multielectron coincidence method using the magnetic bottle electron spectroscopic technique. A predominance of the direct path to triple photoionization for the formation of Ne{sup 3+} in the 1s2s{sup 2}2p{sup 4} configuration is observed. It is demonstrated that the energy distribution evolves with photon energy and indicates a significant difference with triple photoionization involving only valence electrons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low-energy electron spectrum of a copper target bombarded by {alpha}-particles of {sup 238}Pu

The ({alpha}e) time coincidence method is applied to study the low-energy electron spectrum of a copper target bombarded by {alpha}-particles of {sup 238}Pu. Ionization of atoms bombarded by charged particles is considered as the shaking of electrons into the continuous spectrum due to a sudden perturbation by a flying particle. A comparison of experimental and calculated distributions showed good agreement, which confirms the accuracy of the ionization description as a result of the shaking effect.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effective g-factors of carriers in inverted InAs/GaSb bilayers

We perform tilt-field transport experiment on inverted InAs/GaSb, which hosts quantum spin Hall insulator. By means of coincidence method, Landau level (LL) spectra of electron and hole carriers are systematically studied at different carrier densities tuned by gate voltages. When Fermi level stays in the conduction band, we observe LL crossing and anti-crossing behaviors at odd and even filling factors, respectively, with a corresponding g-factor of 11.5. It remains nearly constant for varying filling factors and electron densities. On the contrary, for GaSb holes, only a small Zeeman splitting is observed even at large tilt angles, indicating a g-factor of less than 3.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗