Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COHERENT SCATTERING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Data-driven discovery of dynamics from time-resolved coherent scattering

Coherent X-ray scattering (CXS) techniques are capable of interrogating dynamics of nano- to mesoscale materials systems at time scales spanning several orders of magnitude. However, obtaining accurate theoretical descriptions of complex dynamics is often limited by one or more factors—the ability to visualize dynamics in real space, computational cost of high-fidelity simulations, and effectiveness of approximate or phenomenological models. In this work, we develop a data-driven framework to uncover mechanistic models of dynamics directly from time-resolved CXS measurements without solving the phase reconstruction problem for the entire time series of diffraction patterns. Our approach uses neural differential equations to parameterize unknown real-space dynamics and implements a computational scattering forward model to relate real-space predictions to reciprocal-space observations. This method is shown to recover the dynamics of several computational model systems under various simulated conditions of measurement resolution and noise. Moreover, the trained model enables estimation of long-term dynamics well beyond the maximum observation time, which can be used to inform and refine experimental parameters in practice. Finally, we demonstrate an experimental proof-of-concept by applying our framework to recover the probe trajectory from a ptychographic scan. Our proposed framework bridges the wide existing gap between approximate models and complex data.

36 MATERIALS SCIENCE↗

Solar flare ionization in the mesosphere observed by coherent-scatter radar

The coherent-scatter technique, as used with the Urbana radar, is able to measure relative changes in electron density at one altitude during the progress of a solar flare when that altitude contains a statistically steady turbulent layer. This work describes the analysis of Urbana coherent-scatter data from the times of 13 solar flares in the period from 1978 to 1983. Previous methods of measuring electron density changes in the D-region are summarized. Models of X-ray spectra, photoionization rates, and ion-recombination reaction schemes are reviewed. The coherent-scatter technique is briefly described, and a model is developed which relates changes in scattered power to changes in electron density. An analysis technique is developed using X-ray flux data from geostationary satellites and coherent scatter data from the Urbana radar which empirically distinguishes between proposed D-region ion-chemical schemes, and estimates the nonflare ion-pair production rate.

Parker, J. W.↗

SU-E-I-64: X-Ray Coherent Scatter Mammography Simulation

Purpose: Conventional mammography has poor contrast between healthy and cancerous tissues due to the small difference in attenuation properties. Coherent scatter potentially provides more information because interference of coherently scattered radiation depends on the average intermolecular spacing, and can be used to characterize tissue types. However, typical coherent scatter analysis techniques are not compatible with rapid low dose screening modalities. Coherent scatter slot scan imaging is a novel imaging technique which provides new information with higher contrast. In this work a simulation was performed of coherent scatter slot scan imaging to assess its performance and provide system optimization. Methods: In coherent scatter imaging, the coherent scatter is exploited using a conventional slot scan mammography system with anti-scatter grids tilted at the characteristic angle of cancerous tissues. A Monte Carlo simulation was used to simulate the coherent scatter imaging. System optimization was performed across several parameters, including source voltage and filtration, tilt angle, source and grid distances, grid ratio, and shielding geometry. Results: The contrast was high and increased as the grid tilt angle was increased beyond the characteristic angle for the modeled carcinoma, and as the source voltage increased. Source filtration did not have a significant effect on contrast. Increasing grid ratio improved contrast at the expense of decreasing the signal to noise ratio (SNR). As the tumor size is decreased, additional shields to block the fat signal are necessary in order to detect the cancer signal. Conclusion: Coherent scatter analysis using a wide slot setup is promising as an enhancement for screening mammography. This work was supported by National Institutes of Health, # 7 R01EB009715.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An investigation of turbulent scatter from the mesosphere as observed by coherent-scatter radar

Turbulent scatter from he mesosphere is observed using the Urbana coherent-scatter radar. The variation in signal-to-noise ratio as a function of time-of-day is examined. The origin of scattering regions is investigated by comparing the variations in scattered power and Doppler velocity. Nighttime echoes are shown for periods of enhanced electron concentration. The spectrum of the returned signal is studied with a resolution of ten seconds. Spectral information is used to increase altitude resolution and observe the motion of scatterers. The expected variation in signal-to-noise ratio with solar flux is observed. It is found that variations in the scattered power generally do not correspond to the gravity waves which are simultaneously observed. Turbulent layers are observed at altitudes with high shear in the horizontal velocity and at altitudes with low shear. The ten-second resolution is necessary to distinguish meteor echoes from echoes produced by the advection of a scattering layer through the radar beam.

Gibbs, K. P.↗

TH-AB-209-10: Breast Cancer Identification Through X-Ray Coherent Scatter Spectral Imaging

Purpose: We have previously described the development and testing of a coherent-scatter spectral imaging system for identification of cancer. Our prior evaluations were performed using either tissue surrogate phantoms or formalin-fixed tissue obtained from pathology. Here we present the first results from a scatter imaging study using fresh breast tumor tissues obtained through surgical excision. Methods: A coherent-scatter imaging system was built using a clinical X-ray tube, photon counting detectors, and custom-designed coded-apertures. System performance was characterized using calibration phantoms of biological materials. Fresh breast tumors were obtained from patients undergoing mastectomy and lumpectomy surgeries for breast cancer. Each specimen was vacuum-sealed, scanned using the scatter imaging system, and then sent to pathology for histological workup. Scatter images were generated separately for each tissue specimen and analyzed to identify voxels containing malignant tissue. The images were compared against histological analysis (H&E + pathologist identification of tumors) to assess the match between scatter-based and histological diagnosis. Results: In all specimens scanned, the scatter images showed the location of cancerous regions within the specimen. The detection and classification was performed through automated spectral matching without the need for manual intervention. The scatter spectra corresponding to cancer tissue were found to be in agreement with those reported in literature. Inter-patient variability was found to be within limits reported in literature. The scatter images showed agreement with pathologist-identified regions of cancer. Spatial resolution for this configuration of the scanner was determined to be 2–3 mm, and the total scan time for each specimen was under 15 minutes. Conclusion: This work demonstrates the utility of coherent scatter imaging in identifying cancer based on the scatter properties of the tissue. It presents the first results from coherent scatter imaging of fresh (unfixed) breast tissue using our coded-aperture scatter imaging approach for cancer identification.

60 APPLIED LIFE SCIENCES↗

The Urbana coherent-scatter radar: Synthesis and first results

A coherent scatter radar system was synthesized and several hundred hours of echo power and line of sight velocity data obtained. The coherent scatter radar utilizes a diode array and components from meteor radar. The receiving system permits a time resolution of one minute in the data. Echo power from the D region shows a high degree of variability from day to day. Examples of changes in power level at shorter time scales are observed. Velocity data show the existence of gravity waves and occasionally exhibit vertical standing wave characteristics.

Gibbs, K. P.↗

SU-F-I-53: Coded Aperture Coherent Scatter Spectral Imaging of the Breast: A Monte Carlo Evaluation of Absorbed Dose

Purpose: Coherent scatter based imaging has shown improved contrast and molecular specificity over conventional digital mammography however the biological risks have not been quantified due to a lack of accurate information on absorbed dose. This study intends to characterize the dose distribution and average glandular dose from coded aperture coherent scatter spectral imaging of the breast. The dose deposited in the breast from this new diagnostic imaging modality has not yet been quantitatively evaluated. Here, various digitized anthropomorphic phantoms are tested in a Monte Carlo simulation to evaluate the absorbed dose distribution and average glandular dose using clinically feasible scan protocols. Methods: Geant4 Monte Carlo radiation transport simulation software is used to replicate the coded aperture coherent scatter spectral imaging system. Energy sensitive, photon counting detectors are used to characterize the x-ray beam spectra for various imaging protocols. This input spectra is cross-validated with the results from XSPECT, a commercially available application that yields x-ray tube specific spectra for the operating parameters employed. XSPECT is also used to determine the appropriate number of photons emitted per mAs of tube current at a given kVp tube potential. With the implementation of the XCAT digital anthropomorphic breast phantom library, a variety of breast sizes with differing anatomical structure are evaluated. Simulations were performed with and without compression of the breast for dose comparison. Results: Through the Monte Carlo evaluation of a diverse population of breast types imaged under real-world scan conditions, a clinically relevant average glandular dose for this new imaging modality is extrapolated. Conclusion: With access to the physical coherent scatter imaging system used in the simulation, the results of this Monte Carlo study may be used to directly influence the future development of the modality to keep breast dose to a minimum while still maintaining clinically viable image quality.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-I-04: Characterization of Fan Beam Coded Aperture Coherent Scatter Spectral Imaging Methods for Differentiation of Normal and Neoplastic Breast Structures

Purpose: This study intends to characterize the spectral and spatial resolution limits of various fan beam geometries for differentiation of normal and neoplastic breast structures via coded aperture coherent scatter spectral imaging techniques. In previous studies, pencil beam raster scanning methods using coherent scatter computed tomography and selected volume tomography have yielded excellent results for tumor discrimination. However, these methods don’t readily conform to clinical constraints; primarily prolonged scan times and excessive dose to the patient. Here, we refine a fan beam coded aperture coherent scatter imaging system to characterize the tradeoffs between dose, scan time and image quality for breast tumor discrimination. Methods: An X-ray tube (125kVp, 400mAs) illuminated the sample with collimated fan beams of varying widths (3mm to 25mm). Scatter data was collected via two linear-array energy-sensitive detectors oriented parallel and perpendicular to the beam plane. An iterative reconstruction algorithm yields images of the sample’s spatial distribution and respective spectral data for each location. To model in-vivo tumor analysis, surgically resected breast tumor samples were used in conjunction with lard, which has a form factor comparable to adipose (fat). Results: Quantitative analysis with current setup geometry indicated optimal performance for beams up to 10mm wide, with wider beams producing poorer spatial resolution. Scan time for a fixed volume was reduced by a factor of 6 when scanned with a 10mm fan beam compared to a 1.5mm pencil beam. Conclusion: The study demonstrates the utility of fan beam coherent scatter spectral imaging for differentiation of normal and neoplastic breast tissues has successfully reduced dose and scan times whilst sufficiently preserving spectral and spatial resolution. Future work to alter the coded aperture and detector geometries could potentially allow the use of even wider fans, thereby making coded aperture coherent scatter imaging a clinically viable method for breast cancer detection. United States Department of Homeland Security; Duke University Medical Center - Department of Radiology; Carl E Ravin Advanced Imaging Laboratories; Duke University Medical Physics Graduate Program.

60 APPLIED LIFE SCIENCES↗

Observations of the upper troposphere and lower stratosphere using the urbana coherent-scatter radar

The Urbana coherent-scatter radar was used to observe the upper troposphere and lower stratosphere, and 134 hours of data were collected. Horizontal wind measurements show good agreement with balloon-measured winds. Gravity waves were frequently observed, and were enhanced during convective activity. Updrafts and downdrafts were observed within thunderstorms. Power returns are related to hydrostatic stability, and changes in echo specularity are shown.

Goss, L. D.↗

Synchrotron-based coherent scatter x-ray projection imaging using an array of monoenergetic pencil beams

Traditional projection x-ray imaging utilizes only the information from the primary photons. Low-angle coherent scatter images can be acquired simultaneous to the primary images and provide additional information. In medical applications scatter imaging can improve x-ray contrast or reduce dose using information that is currently discarded in radiological images to augment the transmitted radiation information. Other applications include non-destructive testing and security. A system at the Canadian Light Source synchrotron was configured which utilizes multiple pencil beams (up to five) to create both primary and coherent scatter projection images, simultaneously. The sample was scanned through the beams using an automated step-and-shoot setup. Pixels were acquired in a hexagonal lattice to maximize packing efficiency. The typical pitch was between 1.0 and 1.6 mm. A Maximum Likelihood-Expectation Maximization-based iterative method was used to disentangle the overlapping information from the flat panel digital x-ray detector. The pixel value of the coherent scatter image was generated by integrating the radial profile (scatter intensity versus scattering angle) over an angular range. Different angular ranges maximize the contrast between different materials of interest. A five-beam primary and scatter image set (which had a pixel beam time of 990 ms and total scan time of 56 min) of a porcine phantom is included. For comparison a single-beam coherent scatter image of the same phantom is included. The muscle-fat contrast was 0.10 {+-} 0.01 and 1.16 {+-} 0.03 for the five-beam primary and scatter images, respectively. The air kerma was measured free in air using aluminum oxide optically stimulated luminescent dosimeters. The total area-averaged air kerma for the scan was measured to be 7.2 {+-} 0.4 cGy although due to difficulties in small-beam dosimetry this number could be inaccurate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Giant Zero Bias Anomaly due to Coherent Scattering from Frozen Phonon Disorder in Quantum Point Contacts

Here demonstrate an unusual manifestation of coherent scattering for electron waves in mesoscopic quantum point contacts, in which fast electron dynamics allows the phonon system to serve as a quasistatic source of disorder. The low-temperature conductance of these devices exhibits a giant ($\gg2e^2/h$) zero bias anomaly (ZBA), the features of which are reproduced in a nonequilibrium model for coherent scattering from the “frozen” phonon disorder. According to this model, the ZBA is understood to result from the in situ electrical manipulation of the phonon disorder, a mechanism that could open up a pathway to the on-demand control of coherent scattering in the solid state.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TH-AB-209-11: Breast Microcalcification Classification Using Spectral X-Ray Coherent Scatter Computed Tomography

Purpose: To investigate the ability of Coherent Scatter Computed Tomography (CSCT) to distinguish non-invasively between type I calcifications, consisting of calcium oxalate dihydrate (CO) compounds which are more often associated with benign lesions, and type II calcifications containing hydroxyapatite (HA) which are predominantly associated with malignant tumors. Methods: The coherent scatter cross sections of HA and CO were measured using an energy dispersive x-ray diffractometer. The measured cross sections were introduced into MC-GPU Monte Carlo simulation code for studying the applicability of CSCT to discriminate between the two types of microcalcifications within the whole breast. Simulations were performed on a virtual phantom with inserted HA and CO spots of different sizes and placed in regions of interest having different background compositions. We considered a polychromatic x-ray source and an energy resolving photon counting detector. We applied an algorithm that estimates scatter components in projection space in order to obtain material-specific images of the breast. As material components adipose, glandular, HA and CO were used. The relative contrast of HA and CO components were used for type I and type II microcalcification discrimination. Results: The reconstructed CSCT images showed material-specific component-contrast values, with the highest CO or HA component contrast corresponding generally to the actual CO or HA feature, respectively. The discrimination performance varies with the x-ray intensity, calcification size, and background composition. The results were summarized using receiver operating characteristic (ROC) analysis with the area under the curve (AUC) taken as an overall indicator of discrimination performance and showing high AUC values up to unity. Conclusion: The simulation results obtained for a uniform breast imaging phantom indicate that CSCT has potential to be used as a non-invasive method for discrimination between type I and type II microcalcifications.

60 APPLIED LIFE SCIENCES↗

Optimization of a coherent soft x-ray beamline for coherent scattering experiments at NSLS-II

The coherent soft x-ray and full polarization control (CSX) beamline at the National Synchrotron Light Source - II (NSLS-II) will deliver 1013 coherent photons per second in the energy range of 0.2-2 keV with a resolving power of 2000. The source, a dual elliptically polarizing undulator (EPU), and beamline optics should be optimized to deliver the highest possible coherent flux in a 10-30 {micro}m spot for use in coherent scattering experiments. Using the computer code Synchrotron Radiation Workshop (SRW), we simulate the photon source and focusing optics in order to investigate the conditions which provide the highest usable coherent intensity on the sample. In particular, we find that an intermediate phasing magnet is needed to correct for the relative phase between the two EPUs and that the optimum phase setting produces a spectrum in which the desired wavelength is slightly red-shifted thus requiring a larger aperture than originally anticipated. This setting is distinct from that which produces an on-axis spectrum similar to a single long undulator. Furthermore, partial coherence calculations, utilizing a multiple electron approach, indicate that a high degree of spatial coherence is still obtained at the sample location when such an aperture is used. The aperture size which maximizes the signal-to-noise ratio of a double-slit experiment is explored. This combination of high coherence and intensity is ideally suited for x-ray ptychography experiments which reconstruct the scattering density from micro-diffraction patterns. This technique is briefly reviewed and the effects on the image quality of proximity to the beamline focus are explored.

36 MATERIALS SCIENCE↗

Coherent scattering of electromagnetic waves by self-organized dust structures: Degree of coherence

It is demonstrated explicitly that the scattering of electromagnetic waves by dust structures can be strongly enhanced as compared to incoherent scattering by random electrons. If the size of the dust structure is much less than the wavelength of the incident radiation, the scattering is coherent. In this case, the scattering is proportional to the square of the total number of electrons in the structure. In the opposite limit, the scattering is incoherent being proportional to the total number of electrons in the structure. The factor describing the degree of coherency is calculated numerically for several models of self-organized structures. It is demonstrated in general way that for sudden heating of electrons, the factor of coherency in scattering by structures can decrease by several orders of magnitude with subsequent increase after the heating is switched off. In laboratory dusty plasmas, the coherent scattering is proposed for diagnostics of universal structuring instability and as a probe for determining the properties typical for self-organized nature of structures that are observed in recent experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamical Theory of X-Ray Diffraction for Restricted Beams: I. Coherent Scattering by a Porous Crystal

A dynamical theory of X-ray coherent scattering of spatially restricted beams in porous crystals has been developed. The solutions have been obtained for the amplitude transmission and reflection coefficients as functions of the beam size and structural characteristics of the crystal. The peculiarities of the formation of reciprocal space maps as well as vertical and transverse cross sections of coherent scattering by porous films, gradient structures, and superlattices have been demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Partially coherent scattering in stellar chromospheres. I - Effects on resonance line thermalization

The conditions necessary for partially coherent scattering to influence the thermalization depth are investigated, and the effects of partial redistribution in homogeneous slab atmospheres are approximated using several common resonance lines as examples. For electron densities above 10 exp 10/cu cm, it is concluded that even when coherent scattering dominates the escape process, the thermalization depths of the strongest resonance lines of H, Ca II, and Mg II agree roughly with the Doppler diffusion in frequency. No elastic scattering effects on the thermalization of Mg II h and k and Ca II H and K are found. At lower densities, such as for giant star chromospheres and QSO models, the results deviate strongly from the Doppler complete redistribution case.

Gayley, Kenneth G.↗