Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COBALT 53”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Nuclear Data Sheets for A = 53

The 1999 evaluation of A = 53 (1999Hu14) has been revised using experimental nuclear structure data available before April 2007. A summary of information obtained in various reaction and decay experiments is presented, together with adopted level schemes and properties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mass measurements in the vicinity of the doubly magic waiting point {sup 56}Ni

Masses of {sup 56,57}Fe, {sup 53}Co{sup m}, {sup 53,56}Co, {sup 55,56,57}Ni, {sup 57,58}Cu, and {sup 59,60}Zn have been determined with the JYFLTRAP Penning trap mass spectrometer at the Ion-Guide Isotope Separator On-Line facility with a precision of {delta}m/m{<=}3x10{sup -8}. The Q{sub EC} values for {sup 53}Co, {sup 55}Ni, {sup 56}Ni, {sup 57}Cu, {sup 58}Cu, and {sup 59}Zn have been measured directly with a typical precision of better than 0.7 keV and Coulomb displacement energies have been determined. The Q values for proton captures on {sup 55}Co, {sup 56}Ni, {sup 58}Cu, and {sup 59}Cu have been measured directly. The precision of the proton-capture Q value for {sup 56}Ni(p,{gamma}){sup 57}Cu, Q{sub (p,{gamma})}=689.69(51) keV, crucial for astrophysical rp-process calculations, has been improved by a factor of 37. The excitation energy of the proton-emitting spin-gap isomer {sup 53}Co{sup m} has been measured precisely, E{sub x}=3 174.3(10) keV, and a Coulomb energy difference of 133.9(10) keV for the 19/2{sup -} state has been obtained. Except for {sup 53}Co, the mass values have been adjusted within a network of 17 frequency ratio measurements between 13 nuclides, which allowed also a determination of the reference masses {sup 55}Co, {sup 58}Ni, and {sup 59}Cu.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mass measurements near the Z = N line with JYFLTRAP

Masses of nuclides involved in astrophysical rp and {nu}p processes have to be known precisely in order to model these processes reliably. Mass excesses for 90 ground state and 8 isomeric states of neutron-deficient nuclides have been determined with a precision of better than 10 keV with the JYFLTRAP double Penning trap mass spectrometer at the Ion-Guide Isotope Separator On-Line facility in Jyvaeskylae. Highlights of the measurements related to nuclear astrophysics are given. Some of the measured isomers, such as {sup 53}Co{sup m}, {sup 90}Tc{sup m}, and {sup 95}Pd{sup m}, and implications for the excitation energy of the 21{sup +} isomer in {sup 94}Ag are briefly discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear spectroscopy with Geant4: Proton and neutron emission & radioactivity

With the aid of a novel combination of existing equipment – JYFLTRAP and the TASISpec decay station – it is possible to perform very clean quantum-state selective, high-resolution particle-γ decay spectroscopy. We intend to study the determination of the branching ratio of the ℓ = 9 proton emission from the I{sup π} = 19/2{sup −}, 3174-keV isomer in the N = Z − 1 nucleus {sup 53}Co. The study aims to initiate a series of similar experiments along the proton dripline, thereby providing unique insights into “open quantum systems”. The technique has been pioneered in case studies using SHIPTRAP and TASISpec at GSI. Newly available radioactive decay modes in Geant4 simulations are going to corroborate the anticipated experimental results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of corrosion layer composition and thermal pretreatment on the radiolytic generation of molecular hydrogen from aluminum alloys

To fully evaluate the feasibility of extending the dry storage of aluminum-clad spent nuclear fuel (ASNF) in helium-backfilled cannisters, the amount of radiation-induced molecular hydrogen (H 2 ) generated and the impact of absorbed radiation dose on the ASNF corrosion layer composition must be accurately assessed. Here, in this study, we report a slowing in the rate of radiolytic H 2 generation for pre-corroded AA1100 and AA6061 aluminum alloy coupons irradiated to up to 53 MGy of absorbed cobalt-60 gamma dose. By exploring a variety of thermal pretreatment conditions for AA6061 coupons, we find that the “steady-state” yield of H 2 depends more on the aluminum alloy used than on the treatments applied prior to dry storage. Scanning electron microscopy and positron annihilation lifetime spectroscopy techniques also provided evidence for gamma radiation-induced defects in the corrosion layers of the investigated aluminum alloy coupons for high absorbed doses (~50 MGy), the consequences of which on cladding integrity and H 2 generation should be explored in future works.

38 - RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCL↗

Statistical properties of excited nuclei in the mass range 47 Less-Than-Or-Slanted-Equal-To A Less-Than-Or-Slanted-Equal-To 59

Level densities and their energy dependences for nuclei in the mass range of 47 {<=} A {<=} 59 were determined from the results obtained by measuring neutron-evaporation spectra in respective (p, n) reactions. The spectra of neutrons originating from the (p, n) reactions on {sup 47}Ti, {sup 48}Ti, {sup 49}Ti, {sup 53}Cr, {sup 54}Cr, {sup 57}Fe, and {sup 59}Co nuclei were measured in the proton-energy range of 7-11 MeV. These measurements were performed with the aid of a fast-neutron spectrometer by the time-of-flight method over the base of the EGP-15 pulsed tandem accelerator installed at the Institute for Physics and Power Engineering (Obninsk, Russia). A high resolution of the spectrometer and its stability in the time of flight made it possible to identify reliably discrete low-lying levels along with the continuum part of neutron spectra. Our measured data were analyzed within the statistical equilibrium and preequilibrium models of nuclear reactions. The respective calculations were performed with the aid of the Hauser-Feshbach formalismof statistical theory supplemented with the generalized model of a superfluid nucleus, the back-shifted Fermi gas model, and the Gilbert-Cameron composite formula for nuclear level densities. Nuclear level densities for {sup 47}V, {sup 48}V, {sup 49}V, {sup 53}Mn, {sup 54}Mn, {sup 57}Co, and {sup 59}Ni and their energy dependences were determined. The results are discussed and compared with available experimental data and with recommendations of model-based systematics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement and simulation of the cross sections for nuclide production in {sup 56}Fe and {sup nat}Cr targets irradiated with 0.04- to 2.6-GeV protons

The cross sections for nuclide production in thin {sup 56}Fe and {sup nat}Cr targets irradiated by 0.04-2.6-GeV protons are measured by direct {gamma} spectrometry using two {gamma} spectrometers with the resolutions of 1.8 and 1.7 keV for the {sup 60}Co 1332-keV {gamma} line. As a result, 649 yields of radioactive residual product nuclei have been obtained. The {sup 27}Al(p, x){sup 22}Na reaction has been used as a monitor reaction. The experimental data are compared with the MCNPX (BERTINI, ISABEL), CEM03.02, INCL4.2, INCL4.5, PHITS, and CASCADE07 calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cardiac Magnetic Resonance Imaging Findings in 20-year Survivors of Mediastinal Radiotherapy for Hodgkin's Disease

Purpose: The recognition of the true prevalence of cardiac toxicity after mediastinal radiotherapy requires very long follow-up and a precise diagnostic procedure. Cardiac magnetic resonance imaging (MRI) permits excellent quantification of cardiac function and identification of localized myocardial defects and has now been applied to a group of 20-year Hodgkin's disease survivors. Methods and materials: Of 143 patients treated with anterior mediastinal radiotherapy (cobalt-60, median prescribed dose 40 Gy) for Hodgkin's disease between 1978 and 1985, all 53 survivors were invited for cardiac MRI. Of those, 36 patients (68%) presented for MRI, and in 31 patients (58%) MRI could be performed 20-28 years (median, 24) after radiotherapy. The following sequences were acquired on a 1.5-T MRI: transversal T1-weighted TSE and T2-weighted half-fourier acquisition single-shot turbo-spin-echo sequences, a steady-state free precession (SSFP) cine sequence in the short heart axis and in the four-chamber view, SSFP perfusion sequences under rest and adenosine stress, and a SSFP inversion recovery sequence for late enhancement. The MRI findings were correlated with previously reconstructed doses to cardiac structures. Results: Clinical characteristics and reconstructed doses were not significantly different between survivors undergoing and not undergoing MRI. Pathologic findings were reduced left ventricular function (ejection fraction <55%) in 7 (23%) patients, hemodynamically relevant valvular dysfunction in 13 (42%), late myocardial enhancement in 9 (29%), and any perfusion deficit in 21 (68%). An association of regional pathologic changes and reconstructed dose to cardiac structures could not be established. Conclusions: In 20-year survivors of Hodgkin's disease, cardiac MRI detects pathologic findings in approximately 70% of patients. Cardiac MRI has a potential role in cardiac imaging of Hodgkin's disease patients after mediastinal radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A new insight into neutrino energy loss by electron capture of iron group nuclei in magnetar surfaces

Based on the relativistic mean-field effective interactions theory, and the Lai dong model, we discuss the influences of superstrong magnetic fields (SMFs) on electron Fermi energy, nuclear blinding energy, and single-particle level structure in magnetar surfaces. Using the Shell-Model Monte Carlo method and the Random Phase Approximation theory, we analyze the neutrino energy loss rates (NELRs) by electron capture for iron group nuclei in SMFs. First, when B {sub 12} < 100, we find that the SMFs have a slight influence on the NELRs for most nuclides at relativistic low temperatures (e.g., T {sub 9} = 0.233); nevertheless, the NELRs increase by more than four orders of magnitude at relativistic high temperatures (e.g., T {sub 9} = 15.53). When B {sub 12} > 100, the NELRs decrease by more than three orders of magnitude (e.g., at T {sub 9} = 15.53 for {sup 52–61}Fe, {sup 55–60}Co, and {sup 56–63}Ni). Second, for a certain value of magnetic field and temperature, the NELRs increase by more than four orders of magnitude when ρ{sub 7}⩽10{sup 3}, but as the density increases (i.e., when ρ{sub 7}>10{sup 3}), there is almost no influence on the density of NELRs. For the density around ρ{sub 7}=10{sup 2}, there is an abrupt increase in NELRs when B {sub 12} ≥ 10{sup 3.5}. Such jumps are an indication that the underlying shell structure has changed due to single-particle behavior by SMFs. Finally, we compare our NELRs with those of Fuller et al. (FFN) and Nabi and Klapdor-Kleingrothaus (NKK). For the case without SMFs, one finds that our rates for certain nuclei are close to about five orders of magnitude lower than FFN and NKK at relativistic low temperatures (e.g., T {sub 9} = 1). However, at a relativistic high temperature (e.g., T {sub 9} = 3), our results are in good agreement with NKK, but about one order of magnitude lower than FFN. For the case with SMFs, our NELRs for some iron group nuclei can be about five orders of magnitude higher than those of FFN and NKK. (Note that B {sub 12}, T {sub 9}, and ρ {sub 7} are in units of 10{sup 12} G, 10{sup 9} K, and 10{sup 7} g cm{sup −3}, respectively.)

79 ASTRONOMY AND ASTROPHYSICS↗

Terbium induced glassy magnetism in La,Ca-based cobaltites

The La{sub 0.8–x}Tb{sub x}Ca{sub 0.2}CoO{sub 3} cobaltites of orthoperovskite Pbnm structure were investigated by the X-ray and neutron diffraction, specific heat, and magnetization measurements. The terbium doping has two important effects, it increases the size disorder on perovskite A-sites and influences the magnetic properties due to large Ising-type moments (∼8.9 Bohr magnetons per Tb). The compounds show a bulk magnetic moment below T{sub C} = 82 K, 53 K, and 30 K for x = 0.1, 0.2, and 0.3, respectively. The neutron diffraction evidences a long-range ferromagnetic arrangement of cobalt moments, combined below ∼20 K with ordering of terbium moments in a canted arrangement. A homogeneous magnetic phase is proved for the x = 0.1 sample, while x = 0.2 and 0.3 are in an intrinsically non-homogeneous magnetic state with long-range ordering only comprising 55% and 30% of the sample volumes. The ac susceptibility experiments prove a glassy character of the terbium doped samples and provide arguments for the short-range ordering above T{sub C} and wide distribution of relaxation times.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structural and magnetic phase transitions in NdCoAsO under high pressures

We have investigated structural and magnetic phase transitions under high pressures in a quaternary rare-earth transition-metal arsenide oxide NdCoAsO compound that is isostructural to the high temperature superconductor parent phase NdFeAsO. The four-probe electrical resistance measurements carried out in a designer diamond anvil cell show that the ferromagnetic Curie temperature and antiferromagnetic Neel temperature increase with an increase in pressure. High pressure x-ray diffraction studies using a synchrotron source show a structural phase transition from a tetragonal phase to a new crystallographic phase at a pressure of 23 GPa at 300 K. The NdCoAsO sample remained antiferromagnetic and non-superconducting down to 10 K and up to the highest pressure achieved in this experiment, 53 GPa. A P-T phase diagram for NdCoAsO is presented from ambient conditions to P = 53 GPa and T = 10 K.

36 MATERIALS SCIENCE↗

59 Co(p,X) spallation reaction cross sections for 250 MeV to 2 GeV protons

Cobalt is an advantageous target for probing the physics of nuclear spallation, because it is a naturally mono-isotopic element ( 59 Co), and its per-nucleon binding energy (BE/A = 8.768 MeV) is near the maximum value for all nuclei. We measured nuclear spallation cross sections for the 59 Co(p,X) reaction at five kinetic energies ranging from 250 MeV to 2 GeV. Cross sections for the production of 58 Co, 57 Co, 57 Mn, 56 Co, 56 Mn, 56 Cr, 55 Fe, 53 Fe, 54 Mn, 52 Mn, 51 Cr, 49 Cr, 48 V, 47 Sc, 46 Sc, 44 Sc, and 44 Scm are reported. Where comparable data exist in the EXFOR reaction database, we find that our measured cross sections generally agree. In many cases, we provide data for reactions or energies not currently reported in EXFOR. Our cross sections also provide evidence for the presence of α-clusters within the 59 Co nucleus, a surprising result given the asymmetry in Z (27) and N (32) for this nucleus. Finally, we use our measurements to evaluate the accuracy of spallation cross section simulations from GEANT4-based radiation transport toolkit, performed with the INCLXX-, Bertini-, and Binary-ion-cascade (BIC) based physics lists. This benchmarking activity revealed that the simulations overestimated the cross sections by a factor of ∼2–4 on average, and that the INCL-XX physics list provides the most reliable results. This evaluation informs the selection of the GEANT4 physics lists used for the analysis of data from NASA’s Psyche mission, which will measure γ rays and neutrons resulting from spallation reactions occurring on the surface of an asteroid whose surface is thought to be rich in iron-nickel metal.

43 PARTICLE ACCELERATORS↗

Ultrasonic Nondestructive Diagnosis of Cylindrical Batteries Under Various Charging Rates

Lithium-ion batteries have been used increasingly as electrochemical energy storage systems for electronic devices and vehicles. It is important to accurately estimate the state of charge (SoC) of a battery management system to control the battery operation to optimize performance, lifetime, and safety. The current work experimentally leverages ultrasonic diagnostic technology to investigate the SoC of lithium-ion batteries during the charge/discharge processes. A cylindrical-type nickel-cobalt-aluminum (NCA)–based 2500mAh 20A (INR18650-25R) battery was used for ultrasonic measurements with various charge/discharge rates of C/10.4, C/5.2, and C/1.3 at constant currents. The ultrasonic signals were analyzed for extracting wave velocity and wave attenuation. For all the testing rates, wave velocity increased in the charge process and decreased in the discharge process. Further, velocity profiles corresponding to lower rates of C/10.4 and C/5.2 exhibited primary peaks at the maximum SoCs, whereas the absolute wave velocity of C/1.3 rate showed primary peaks that occurred slightly after the SoC peak, indicating a delayed maximum Young's modulus. The wave attenuation computed for the C/10.4 rate had local maxima in the charge and discharge processes and depicted negative correlations with SoC, ranging from 0% to 18%, and positive correlations with SoC from 18% to 85%. On the other hand, the wave attenuation curves of the C/1.3 rate showed no local peaks and had negative correlations with SoC, ranging from 0% to 28%, and positive correlations with SoC ranging from 28% to 53%.

25 ENERGY STORAGE↗

SU-E-J-206: Adaptive Radiotherapy for Gynecological Malignancies with MRIGuided Cobolt-60 Radiotherapy

Purpose: Even in the IMRT era, bowel toxicity and bone marrow irradiation remain concerns with pelvic irradiation. We examine the potential gain from an adaptive radiotherapy workflow for post-operative gynecological patients treated to pelvic targets including lymph nodes using MRI-guided Co-60 radiation therapy. Methods: An adaptive workflow was developed with the intent of minimizing time overhead of adaptive planning. A pilot study was performed using retrospectively analyzed images from one patient’s treatment. The patient’s treated plan was created using conventional PTV margins. Adaptive treatment was simulated on the patient’s first three fractions. The daily PTV was created by removing non-target tissue, including bone, muscle and bowel, from the initial PTV based on the daily MRI. The number of beams, beam angles, and optimization parameters were kept constant, and the plan was re-optimized. Normal tissue contours were not adjusted for the re-optimization, but were adjusted for evaluation of plan quality. Plan quality was evaluated based on PTV coverage and normal tissue DVH points per treatment protocol. Bowel was contoured as the entire bowel bag per protocol at our institution. Pelvic bone marrow was contoured per RTOG protocol 1203. Results: For the clinically treated plan, the volume of bowel receiving 45 Gy was 380 cc, 53% of the rectum received 30 Gy, 35% of the bladder received 45 Gy, and 28% of the pelvic bone marrow received 40 Gy. For the adaptive plans, the volume of bowel receiving 45 Gy was 175–201 cc, 55–62% of the rectum received 30 Gy, 21– 27% of the bladder received 45 Gy, and 13–17% of the pelvic bone marrow received 40 Gy. Conclusion: Adaptive planning led to a large reduction of bowel and bone marrow dose in this pilot study. Further study of on-line adaptive techniques for the radiotherapy of pelvic lymph nodes is warranted. Dr. Low is a member of the scientific advisory board of ViewRay, Inc.

60 APPLIED LIFE SCIENCES↗

WE-FG-202-08: Assessment of Treatment Response Via Longitudinal Diffusion MRI On A MRI-Guided System: Initial Experience of Quantitative Analysis

Purpose: To report our initial experience of systematic monitoring treatment response using longitudinal diffusion MR images on a Co-60 MRI-guided radiotherapy system. Methods: Four patients, including 2 head-and-necks, 1 sarcoma and 1 GBM treated on a 0.35 Tesla MRI-guided treatment system, were analyzed. For each patient, 3D TrueFISP MRIs were acquired during CT simulation and before each treatment for treatment planning and patient setup purposes respectively. Additionally, 2D diffusion-weighted MR images (DWI) were acquired weekly throughout the treatment course. The gross target volume (GTV) and brainstem (as a reference structure) were delineated on weekly 3D TrueFISP MRIs to monitor anatomy changes, the contours were then transferred onto the corresponding DWI images after fusing with the weekly TrueFISP images. The patient-specific temporal and spatial variations during the entire treatment course, such as anatomic changes, target apparent diffusion coefficient (ADC) distribution were evaluated in a longitudinal pattern. Results: Routine MRI revealed progressive soft-tissue GTV volume changes (up to 53%) for the H&N cases during the treatment course of 5–7 weeks. Within the GTV, the mean ADC values varied from −44% (ADC decrease) to +26% (ADC increase) in a week. The gradual increase of ADC value was inversely associated with target volume variation for one H&N case. The maximal changes of mean ADC values within the brainstem were 5.3% for the H&N cases. For the large size sarcoma and GBM tumors, spatial heterogeneity and temporal variations were observed through longitudinal ADC analysis. Conclusion: In addition to the superior soft-tissue visualization, the 0.35T MR system on ViewRay showed the potential to quantitatively measure the ADC values for both tumor and normal tissues. For normal tissue that is minimally affected by radiation, its ADC values are reproducible. Tumor ADC values show temporal and spatial fluctuation that can be exploited for personalized adaptive therapy.

60 APPLIED LIFE SCIENCES↗

Dismantling of Loop-Type Channel Equipment of MR Reactor in NRC 'Kurchatov Institute' - 13040

In 2009 the project of decommissioning of MR and RTF reactors was developed and approved by the Expert Authority of the Russian Federation (Gosexpertiza). The main objective of the decommissioning works identified in this project: - complete dismantling of reactor equipment and systems; - decontamination of reactor premises and site in accordance with the established sanitary and hygienic standards. At the preparatory stage (2008-2010) of the project the following works were executed: loop-type channels' dismantling in the storage pool; experimental fuel assemblies' removal from spent fuel repositories in the central hall; spent fuel assembly removal from the liquid-metal-cooled loop-type channel of the reactor core and its placement into the SNF repository; and reconstruction of engineering support systems to the extent necessary for reactor decommissioning. The project assumes three main phases of dismantling and decontamination: - dismantling of equipment/pipelines of cooling circuits and loop-type channels, and auxiliary reactor equipment (2011-2012); - dismantling of equipment in underground reactor premises and of both MR and RTF in-vessel devices (2013-2014); - decontamination of reactor premises; rehabilitation of the reactor site; final radiation survey of reactor premises, loop-type channels and site; and issuance of the regulatory authorities' de-registration statement (2015). In 2011 the decommissioning license for the two reactors was received and direct MR decommissioning activities started. MR primary pipelines and loop-type facilities situated in the underground reactor hall were dismantled. Works were also launched to dismantle the loop-type channels' equipment in underground reactor premises; reactor buildings were reconstructed to allow removal of dismantled equipment; and the MR/RTF decommissioning sequence was identified. In autumn 2011 - spring 2012 results of dismantling activities performed are: - equipment from underground rooms (No. 66, 66A, 66B, 72, 64, 63) - as well as from water and gas loop corridors - was dismantled, with the total radwaste weight of 53 tons and the total removed activity of 5,0 x 10{sup 10} Bq; - loop-type channel equipment from underground reactor hall premises was dismantled; - 93 loop-type channels were characterized, chopped and removed, with radwaste of 2.6 x 10{sup 13} Bq ({sup 60}Co) and 1.5 x 10{sup 13} Bq ({sup 137}Cs) total activity removed from the reactor pool, fragmented and packaged. Some of this waste was placed into the high-level waste (HLW) repository of the Center. Dismantling works were executed with application of remotely operated mechanisms, which promoted decrease of radiation impact on the personnel. The average individual dose for the personnel was 1.9 mSv/year in 2011, and the collective dose is estimated as 0.0605 man x Sv/year. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗