Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CO2 measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Comparisons of the v11.1 Orbiting Carbon Observatory‐2 (OCO‐2) X CO2 Measurements With GGG2020 TCCON

The Orbiting Carbon Observatory 2 (OCO-2) is NASA's first Earth observation satellite mission dedicated to studying the sources and sinks of carbon dioxide (CO 2 ) on a global scale. The observations of reflected sunlight are inverted in a retrieval algorithm to produce estimates of the dry air mole-fractions of CO 2 (X CO2 ). The OCO-2 Level 2 data release, version 11.1 (v11.1) retrievals from the Atmospheric Carbon Observations from Space (ACOS) algorithm, includes significant improvements in the X CO2 data product compared to older OCO-2 data versions. This work compares the v11.1 X CO2 from OCO-2 against X CO2 estimates collected from a global ground-based network known as the Total Carbon Column Observing Network (TCCON), OCO-2's primary validation source. The OCO-2 project provides a version of the Level 2 data product, called “lite” files that include calibrated and bias-corrected XCO2 values, accessible together with all OCO-2 data products through the NASA Goddard Earth Sciences Data and Information Services Center (GES DISC). This work shows that OCO-2 X CO2 observations made between September 2014 and December 2023, after quality filtering and the application of an averaging kernel correction, agree well with coincident TCCON data for all OCO-2 observational modes of land (nadir, glint, target) and ocean (glint). The aggregated, bias-corrected, and quality-filtered absolute average bias values are less than or equal to 0.20 parts per million (ppm) globally for all OCO-2 observation modes, where the biases do not indicate a statistically significant time dependence. The land nadir/glint mode has the lowest bias value of −0.03 ± 0.85 ppm.

54 ENVIRONMENTAL SCIENCES↗

The effect of building retrofit measures on CO2 emission reduction – A case study with U.S. Medium office buildings

Building retrofit has great potential to reduce CO2 emissions since buildings are responsible for 36% of emissions in the United States. Several existing studies have examined the effect of building retrofit measures on CO2 emission reduction. However, these studies oversimplified emission factors of electricity by adopting constant annual emission factors. This study uses hourly emission factors of electricity to analyze the effect of building retrofit measures on emission reduction using U.S. medium office buildings as an example. We analyzed CO2 emission reduction effects of eight building retrofit measures that related to envelop and mechanical system in five locations: Tampa, San Diego, Denver, Great Falls, and International Falls. The main findings are: (1) estimating CO2 emission reduction with constant emission factors overestimates the emission reduction for most measures in San Diego, while it underestimates the emission reduction for most measures in Denver and International Falls; (2) The same retrofit measure may have different effects in CO2 emission reduction depending on the climates. For instance, improving lighting efficiency and improving equipment efficiency have less impacts in emission reduction in cold climates than hot climates; and (3) The most energy efficient measure may not be the most emission efficient measure. For example, in Great Falls, the most energy efficient measure is improving equipment efficiency, but the most emission efficient measure is improving heating efficiency.

Lou, Yingli↗

The Dynamic Assimilation Technique measures photosynthetic CO2 response curves with similar fidelity as steady-state approaches in half the time

The net CO2 assimilation (A) response to intercellular CO2 concentration (Ci) is a fundamental measurement in photosynthesis and plant physiology research. The conventional A/Ci protocols rely on steady-state measurements and take 15-40 minute per measurement, limiting data resolution or biological replication. Additionally, there are several CO2 protocols employed across the literature, without clear consensus as to the optimal protocol or systematic biases in their estimations. We compared the non-steady state Dynamic Assimilation Technique (DAT) protocol and the three most used CO2 protocols in steady-state measurements, and tested whether different CO2 protocols lead to systematic differences in estimations of the biochemical limitations to photosynthesis.

A/Ci response↗

Stem CO2 Efflux measurements from Manaus, Brazil, 2017

This data was collected in order to test the effects of temperatures on the autotrophic respiratory process in the tropics. This data package contains raw real-time stem CO2 efflux files during the night and day from 3 different species near the K34 in Manaus during the day and the night. Raw and derived data files are included in the format of .csv and .xlsx and information about the canopy trees and temperatures recorded can be found in the field event log using microsoft excel. The data was collected from three canopy dominant trees in the central Amazon near the K34 tower. Real-time stem CO2 efflux was determined using a Li7000 gas analyzer configured in differential mode and connected to a dynamic stem chamber secured to the stem at breast height using straps to generate a reasonable seal. Ambient air was continuously pumped into the stem chamber and CO2 concentrations of the air entering and exiting the chamber were continuously monitored. CO2 efflux was calculated based on the CO2 concentration difference between ambient and stem chambers, the flow rate of air through the chamber, and the area of the enclosed stem. Additional auxiliary data, including sap flow and crown temperature were also measured. No data processing or QA/QC was done on the raw data packages.

54 ENVIRONMENTAL SCIENCES↗

Patch-level chamber-based CH4 and CO2 flux measurements in freshwater and salt marshes of coastal Louisiana

This dataset contains chamber-based carbon dioxide and methane flux measurements from ecohydrological patches in two coastal wetlands in Louisiana (within the footprint of AmeriFlux sites US-LA2 and US-LA3). Measurements span four patches, two per wetland. At the freshwater marsh (US-LA2), patches were dominated by Sagittaria lancifolia or co-dominated by Sagittaria lancifolia and Typha latifolia. At the salt marsh site (US-LA3), patches were dominated by Spartina alterniflora or Juncus roemerianus. Flux measurements included (i) wetland surface-level measurements encompassing the entire soil-water-vegetation column and (ii) soil-water surface chamber measurements that excluded emergent vegetation. At US-LA3, open-water pools were common and were also measured as a patch type. With this data we aimed to assess differences in gas flux pathways within ecohydrological patches across different wetland types. Files can be read in any program or code typical of processing .csv file types. "PatchChambers_LA2LA3.csv" covers flux data from patch level chambers which includes bulk CO2/CH4 flux encompassing water, soil, and vegetation within each chamber. "Water_Soil_SurfaceChamber_LA2LA3.csv" has CO2/CH4 flux data from chambers measuring only the water-soil surface without the effects of vegetation. Metadata can be found in the similarly named files for each data sheet ("xxxx_md.csv").

54 ENVIRONMENTAL SCIENCES↗

Soil Environmental Conditions in the East River Watershed, CO

This dataset contains depth-resolved soil environmental variables collected between June 2016 and October 2018 from the Bradley Meadow site in the East River watershed. Datalogger output from 7 Campbell CS655 12 cm Soil Moisture and Temperature Sensors including depth, temperature, volumetric water content, and electrical conductivity are included in ‘BM_Merged_T_VWC_0616_10_18.csv’. Sensors were installed in June 2016. Data have been processed to merge raw sensor data and to remove additional variables. No additional QA/QC was performed. Measured pCO2 and depth are contained in ‘BM_EGM_WELL_CO2.csv’. These data represent gas well samples measured via injection using a PP Systems EGM-5 infra-red gas analyzer as described in the methods section. Measured CO2 surface flux values are contained in 'BM_EGM_Surface_Flux.csv'. These were measured using the PP Systems EGM-5 with the Soil Respiration Chamber attachment. Multiple reps are reported for each measurement including CO2 flux rate calculations using built-in linear and quadratic function methods, and average and standard deviations are taken across all reps and calculation methods.

54 ENVIRONMENTAL SCIENCES↗

Atmospheric Observation System for Greenhouse Gases (GHG) Instrument Handbook

The Greenhouse Gas (GhG) Measurement system is a combination of two systems in series: (1) the Tower Gas Processing (TGP) System, an instrument rack which pulls, pressurizes, and dries air streams from an atmospheric sampling tower through a series of control and monitoring components, and (2) the Picarro model G2301 cavity ringdown spectrometer (CRDS), which measures CO2, CH4, and H2O vapor; the primary measurements of the GhG system.

54 ENVIRONMENTAL SCIENCES↗

SPRUCE: Sphagnum Carbon, Nitrogen and Phosphorus Concentrations in the SPRUCE Experimental Plots

This data set reports the concentrations of carbon (C), nitrogen (N), and phosphorus (P) in capitula, current year stems, and one-year old stem tissue of Sphagnum from 2016-2018. Measurements are continuing and new data will be appended as they become available. Three types of Sphagnum were sampled -- S. angustifolium/fallax from hummocks (AngFal_Hum), S. angustifolium/fallax from hollows (AngFal_Hol), and S. magellanicum from hummocks (Mag_Hum) from SPRUCE experimental study plots. Measurements were made in 10 enclosures comprising five levels of temperature elevation in ambient CO2 and five levels in elevated CO2. Measurements also were made in two ambient (no enclosure) plots. Nutrient concentrations were analyzed in conjunction with assessment of Sphagnum growth, which was measured in 3.79-cm diameter mesh columns collected every October and are described in the related dataset (https://doi.org/10.25581/spruce.049/1426474). The SPRUCE experiment is being conducted at the 8.1-ha S1 bog forest site in northern Minnesota, 40 km north of Grand Rapids, in the USDA Forest Service Marcell Experimental Forest (MEF).

54 ENVIRONMENTAL SCIENCES↗

Short-Term Energy and Meteorological Impacts on Thanksgiving CO2 in Salt Lake City

Abstract Long-term, high-frequency atmospheric CO2 measurements at multiple sites in the Salt Lake City (SLC), Utah, reveal that annual and monthly CO2 variability aligns with a priori estimates of emissions from anthropogenic and biological sources. In this study, we investigate whether short-term fluctuations in anthropogenic emissions, as captured in the Vulcan3 dataset for the United States, can be detected in atmospheric CO2 observations. Specifically, we focus on Thanksgiving holidays, when traffic and energy usage patterns differ from the rest of November. Onroad CO2 emissions exhibit a double peak during weekday morning and evening rush hours but remain relatively low on weekends and Thanksgiving. Interestingly, CO2 mole fractions during Thanksgiving were higher than the rest of November at all SLC monitoring sites, particularly from 2008 to 2013. This increase is partially attributed to elevated energy-related emissions — especially residential sources — and meteorological factors such as weak wind speeds, cold temperature, and a low planetary boundary layer height (PBLH).

 While CO₂ emissions and mole fraction patterns align over time, notable spatial differences exist. For instance, the near-highway site in Murray shows the highest CO₂ mole fractions despite low local emissions, suggesting pollution transport via highways and wind advection. Random Forest model-based SHapley Additive exPlanations (SHAP) analysis reveals that onroad emissions dominate CO2 contributions on weekdays and weekends, while energy-related emissions play a larger role during Thanksgiving, alongside meteorological drivers such as wind speed and PBLH. Across six urban cities, CO2 emissions display a consistent pattern: residential and commercial (onroad) emissions peak during Thanksgiving (weekday) with substantial (minimal) year-to-year variability. These findings highlight that urban CO₂ variability is driven by the combined influence of emissions and meteorology, underscoring the need for integrated mitigation strategies. Additionally, multi-site measurements are essential for accurate source attribution and the development of effective policy interventions. 

Ryoo, Ju-Mee (ORCID:0000000234256296)↗

Moisture Effect on Chitin Decomposition Biogeochemistry

This dataset contains data files for multiple measurements of sample biogeochemistry and function collected for the Soils SFA Chitin Decomposition project in task 2.2. Samples were generated from soil incubated under different moisture levels, with and without chitin. Each sheet in the file refers to the preprocessed data collected. Sheet 1 "Respiration" measures CO2 production daily for the course of the incubation. Sheet 2 "Biomass" contains the microbial biomass and salt extractable measurements for carbon and nitrogen. Sheet 3 "Chitin" is for HPLC measured chitin from each sample. Sheet 4 "Extracellular Enzyme Assays" records the level of activity for several enzyme assays. Sheet 5 "Enzyme Kinetics" measures degradation of substrate over time for all samples.

Reichart, Nicholas J [Pacific Northwest National L↗

Evaluating the Effect of Vane Trailing Edge Flow on Turbine Rim Sealing

Abstract Modern gas turbine development continues to move toward increased overall efficiency, driven in part by higher firing temperatures that point to a need for more cooling air to prevent catastrophic component failure. However, using additional cooling flow bled from the upstream compressor causes a corresponding detriment to overall efficiency. A primary candidate for cooling flow optimization is purge flow, which contributes to sealing the stator–rotor cavity and prevents ingestion of hot main gas path (MGP) flow into the wheelspace. Previous research has identified that the external main gas path flow physics play a significant role in driving rim seal ingestion. However, the potential impact of other cooling flow features on ingestion behavior, such as vane trailing edge (VTE) flow, is absent in the open literature. This paper presents experimental measurements of rim cavity cooling effectiveness collected from a one-stage turbine operating at engine-representative Reynolds and Mach numbers. Carbon dioxide (CO2) was used as a tracer gas in both the purge flow and vane trailing edge flow to investigate flow migration into and out of the wheelspace. Results show that the vane trailing edge flow does in fact migrate into the rim seal and that there is a superposition relationship between individual cooling flow contributions. Computational fluid dynamics (CFD) simulations using unsteady Reynolds-averaged Navier–Stokes (URANS) were used to confirm VTE flow ingestion into the rim seal cavity. Radial and circumferential traverse surveys were performed to quantify cooling flow radial migration through the main gas path with and without vane trailing edge flow. The surveys confirmed that vane trailing edge flow is entrained into the wheelspace as purge flow is reduced. Local CO2 measurements also confirmed the presence of VTE flow deep in the wheelspace cavity.

Engineering↗

AmeriFlux US-GL2 Granite Island

This is the AmeriFlux version of the carbon flux data for the site US-GL2 Granite Island. Site Description - Granite Island is a small island on Lake Superior approximately 10 miles due north of Marquette, Michigan. It is roughly 6.5 miles from shore and is occupied by a lighthouse, bell tower, Coast Guard light tower, and other small structures. A flux tower to measure H, LE, and meteorological data was installed atop the bell tower in July of 2009 and has been in continuous operation since then (aside from occasional power outages or other sources of data loss). CO2 measurements were added to the flux tower in October of 2010.

Lenters, John [University of Michigan Biological S↗

Cryogenic Carbon Capture™ (CCC) Status Report

The Cryogenic Carbon Capture™ (CCC) process separates CO2 from light gases in essentially any continuous process. CCC cools the gases to the frost or desublimation point of CO2 (-100 to -135 °C), separates and pressurizes the solids, and warms all streams to produce a CO2-depleted stream at ambient pressure and a pure (99+%) pressurized liquid CO2 stream typically to about 150 bar, both at ambient temperature. The process also recovers all gas moisture and most gas impurities less volatile than CO2 (NOx, SOx, Hg, PM, UHC, CCC, etc.) in separable streams. CCC nearly eliminates refrigeration energy for sensible temperature changes through heat integration. CCC does require energy to change the CO2 phase from a mixed vapor to a pressurized fluid, which represents the minimum energy required of any process for this separation. CCC uses additional energy for turbomachinery inefficiencies, heat losses, moisture removal and overall process pressure drop. Aside from these real-world energy demands, CCC operates near the minimum energy required to perform this gas separation by minimizing stream recycling. CCC compresses CO2 as a liquid, which is one of several reasons it costs about about half as much and consumes about half as much energy as an amine process when using flue gases with about 15% CO2. The process also has several major additional advantages, including (a) it is a bolt-on retrofit technology that does not need steam or any modification of existing equipment, (b) it recovers water and nearly all pollutants in addition to CO2 from the flue gas, (c) it enables highly efficient and cost effective energy storage at grid scale and on time scales of minutes, (d) it enables NG storage if the energy storage option is used, and (d) it has a small footprint and is minimally disruptive to existing plants, requiring only electrical power and a gas source to operate. Sustainable Energy Solutions (SES) has scaled this technology through several levels, the largest of which captures nominally 1 tonne of CO2/day and is called the skid system. Skid system field tests include utility-scale power plants, cement plants, heating plants, and other utility or industrial sites that burn natural gas, biomass, coal, shredded tires, municipal waste, and combinations of these fuels. These field tests produced 95-99% CO2 capture with CO2 purities of 99+% and initial CO2 contents that range from 4 to 28%. SES currently seeks to scale the system to merchant scale (10-80 tonnes of CO2 per day). In the process of doing so, SES has demonstrated the potential for CCC to contribute to energy storage and direct air capture in innovative and cost-effective ways. This presentation discusses the overall process and highlights results from field and in-house tests. These include (a) measured CO2 capture rates and operating conditions from in-house and field tests, and (b) predicted utility-scale costs and energy demands. This discussion also includes the application of the CCC technology to energy storage and direct air capture.

20 FOSSIL-FUELED POWER PLANTS↗

Estimating uncertainty: A Bayesian approach to modelling photosynthesis in C3 leaves

The Farquhar-von Caemmerer-Berry (FvCB) model is extensively used to model pho-tosynthesis from gas exchange measurements. Since its publication, many methods have been developed to measure, or more accurately estimate, parameters of this model. Here, we have created a tool that uses Bayesian statistics to fit photosyn-thetic parameters using concurrent gas exchange and chlorophyll fluorescence mea-surements whilst evaluating the reliability of the parameter estimation. We have tested this tool on synthetic data and experimental data from rice leaves. Our results indicate that reliable parameter estimation can be achieved whilst only keeping one parameter, Km, that is, Michaelis constant for CO2 by Rubisco, prefixed. Additionally, we show that including detailed low CO2 measurements at low light levels increases reliability and suggests this as a new standard measurement protocol. By providing an estimated distribution of parameter values, the tool can be used to evaluate the quality of data from gas exchange and chlorophyll fluorescence measurement proto-cols. Compared to earlier model fitting methods, the use of a Bayesian statistics-based tool minimizes human interaction during fitting, reducing the subjectivity which is essential to most existing tools. A user friendly, interactive Bayesian tool script is provided.

Bayesian statistics, leaf photosynthesis, mesophyl↗

Carbon Organisms Rhizosphere and Protection in Soil Environment model script and input data for soil moisture-respiration responses in tropical forests

Objectives: Climatic drying is predicted for many tropical forests, yet models remain poorly parameterized for tropical forests, hampering predictions of forest-climate feedbacks. We applied an integrated model–experiment approach, parameterizing an ecosystem model Carbon Organisms Rhizosphere and Protection in the Soil Environment (CORPSE) with tropical forest observational data, and comparing model predictions with a field drying manipulation. We hypothesized that drying would suppress soil CO2 fluxes (i.e., respiration) in already-drier tropical forests, but increases CO2 fluxes in wetter tropical forests by alleviating anaerobiosis. We measured soil CO2 fluxes, soil moisture, soil temperature, and forest floor biomass during wet-dry cycles (2015 – 2022) in four Panamanian forests that vary in rainfall and soil fertility. We used the field data to parameterize and run tests in the model.Results: Measured CO2 fluxes declined in the dry season and peaked in the early wet season ahead of peak soil moisture, resulting in a lower soil moisture optimum for respiration than previously modeled. We used this data to parameterize the model, which then predicted increased soil CO2 fluxes in wetter and fertile forests with drying, and decreased fluxes in drier, infertile forests. In contrast to model predictions, a chronic throughfall exclusion experiment in the forests initially suppressed soil CO2 fluxes across forests, with sustained suppression after four years in the wettest forest only (-28 ± 4% during the dry season), but elevated soil CO2 fluxes in a fertile forest after four years (+75 ± 28% during the late wet season), as predicted by the model. The unexpected negative drying effect in the wettest, most infertile forest could have resulted from reduced vertical flushing of nutrients into soils. Including hydro-nutrient interactions in ecosystem models could improve predictions of tropical forest-climate feedbacks (results presented in Cusack et al. 2023). Datasets included: Code files:CORPSE_array.py: Defines the equations of the CORPSE modelCORPSE_solvers: Functions for running the CORPSE model using either iterative or ordinary differential equation (ODE) solversrun_Panama_sims.py: Read in datasets and run the model simulations for this studyInput data:PanamaGradientEcosystemChem_BT_CPools_20152016CO2_DC_20190615.xlsx: Plot characteristics used in running model simulationsLiCor compiled surface flux only to 2020_03 DC_20200825.xlsx: Surface gas exchange fluxes used in model-data comparisonsPARCHED litterfall data for Ben Sulman LD 20200902.xlsx: Litterfall data used to drive model simulationsInitialization data:state_500y_20190823.csv: Initial state of model pools based on previous spinup runsOutput data:Outputs/prev_moisture_response.csv: Simulations of multiple sites using original model moisture response function.Outputs/updated_moisture_response.csv: Simulations of multiple sites using updated model moisture response function.Outputs/dry15_prev_moisture_response.csv: Simulations with soil moisture reduced by 15%, using original moisture response function.Outputs/dry15_updated_moisture_response.csv: Simulations with soil moisture reduced by 15%, using updated moisture response function.Outputs/dry30_prev_moisture_response.csv: Simulations with soil moisture reduced by 30%, using original moisture response function.Outputs/dry30_updated_moisture_response.csv: Simulations with soil moisture reduced by 30%, using updated moisture response function.Outputs/latestart_prev_moisture_response.csv: Simulations with extended dry season, using original moisture response function.Outputs/latestart_updated_moisture_response.csv: Simulations with extended dry season, using updated moisture response function.Outputs/[site name]_oneyear.csv: One-year simulation for each site in expanded site list using original moisture response function.Outputs/[site name]_oneyear_dried.csv: One-year simulation for each site in expanded site list using original moisture response function, with soil moisture reduced by 25%.Outputs/[site name]_oneyear_updated_moisture_response.csv: One-year simulation for each site in expanded site list using updated moisture response function.Outputs/[site name]_oneyear_updated_moisture_response_dried.csv: One-year simulation for each site in expanded site list using updated moisture response function, with soil moisture reduced by 25%.Field plot location data:There is also a .kml file that includes coordinates for all 32 plots included in the study of four forests (n = 4 throughfall reduction and n = 4 control plots per site).

54 ENVIRONMENTAL SCIENCES↗

Field Measurement of Central CO2 Heat Pump Water Heater for Multifamily Retrofit

Domestic hot water heating of multifamily buildings accounts for a substantial portion of the energy load of existing buildings. This load is made up of both the energy required to produce hot water and the energy needed to maintain the temperature of the heated water within a building’s distribution piping so that heat can be promptly delivered to building occupants as needed. Properly designed heat pump water heater (HPWH) systems have the ability to improve efficiency in both water heating and temperature control operations. Further, CO2 heat pump technology reflects a shift away from traditional refrigerants and toward refrigerants with low global warming potential (GWP). In this paper’s case study, a design consisting of multiple CO2 heat pump water heaters (commonly used in single-family homes) with a novel “swing tank” was proposed to meet the demand for domestic hot water heating and recirculation loop temperature maintenance. The proposed design was applied to the retrofit of a 60-unit, low-rise, multi-family building located in the Pacific Northwest of the United States. The purpose of this paper is to verify the performance of the system including the proposed “swing tank” in a centralized SHW system using CO2 HPWH. It also provides practical information and lessons learned from the retrofit project. Long-term monitoring data showed that the system had a coefficient of performance (COP) of three or greater and provided an average of 20 gallons of hot water per day per apartment. The results of this work indicate that residential-scale CO2 HPWH equipment and a “swing tank” design can efficiently provide domestic hot water heating and temperature maintenance for mid-sized multifamily buildings.

Banks, Adria↗