Engineering PapersSearch

SEARCH · Engineering Papers

Results for “CO₂ separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Equivalent System Mass Comparison of ECLSS CO2 Removal Technologies

This project employs equivalent system mass (ESM) analyses to evaluate and compare state-of-the-art spacecraft CO2 removal systems. The ESM methodology converts sizing characteristics such as volume, power, and cooling requirements into a unified metric of mass, allowing for simple quantitative comparison of equipment impacts on a system level. Comparison of six high TRL technologies – the Carbon Dioxide Removal System (CDRS), Thermal Amine Scrubber (TAS), Carbon Dioxide Removal Assembly (CDRA), Four-Bed CO2 Scrubber (4BCO2), CO2 and Humidity Control Swing Bed (CHC), and the Carbon Dioxide Removal by Ionic Liquid Sorbent (CDRILS) – was achieved using an existing ESM spreadsheet tool that formerly ranked such technologies for consideration on Gateway. Fidelity of the tool was increased through revision with the most up-to-date sizing and performance data for each technology. ESM values were then estimated using NASA-supplied Lunar, Martian, and low-Earth orbit habitat infrastructure costs. This paper details the ESM approach used, lists major performance variables for each CO2 removal option, and summarizes conclusions of the technology comparison. The results are intended to act as a guide to assist programs in their selection of CO2 technologies best suited for a specific vehicle or mission.

Madeleine C Oliver

In-suit CO2 Washout Test System (ICWTS) for CO2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell

An Ultra-long Life, High-performance, Flexible Li-CO2Battery Based on Multifunctional Carbon Electrocatalysts

Integrating CO2 utilization and renewable energy delivery/storage, the rechargeable Li–CO2 battery has been considered as a promising candidate for next-generation secondary batteries. However, high-performance catalyst(s) for efficient formation and decomposition of the discharge product, Li2CO3, are an imperative part of a Li–CO2 battery. The development of flexible Li–CO2 batteries extends their applications into compliant and wearable devices/systems, but at the same time imposes a big challenge for battery fabrication and lifetime enhancement. In this study, a rechargeable quasi-solidus flexible Li–CO2 battery was designed and fabricated using highly active N,S-doped carbon nanotubes (N,S-doped CNTs) as the cathode catalyst, and a smart polymer gel as the flexible electrolyte. This newly-developed flexible Li–CO2 battery exhibited a capacity as high as 23560 mAh g−1 based on the catalyst mass and an ultra-long lifetime of up to 538 cycles with excellent mechanical flexibility. This work provides a platform for the design and development of high-performance flexible Li–CO2 batteries from low-cost, earth-abundant, carbon-based multifunctional cathode catalysts.

Superior stability

Evaluation of Long-Term Storage Stability and Operational Efficiency of Rapid Cycle Amine Adsorbents

With the recent incorporation of Mars Extravehicular Activity (EVA) into the 2025 NASA roadmap, Rapid Cycle Amine (RCA) technology advancement within the Exploration Extravehicular Mobility Unit (xEMU) applies to both the upcoming Lunar Artemis missions and future human exploration of Mars. The incorporation of commercial spacesuit vendors to service NASA’s crewed-space programs since 2021 has increased the demand for regenerable, RCA-based carbon dioxide (CO2) and humidity control adsorbents. The regenerable RCA subunit is the most advanced, long-term solution for CO2 removal and humidity control, enabling both lunar and Martian EVAs. The adsorbent selected for use within the RCA unit must exhibit sufficient storage stability and operational efficiency for prolonged missions. As XploSafe worked to simultaneously develop both a recirculating sub-atmospheric test rig and adsorbents for the RCA system within the xEMU, several novel adsorbents were evaluated for long-term storage stability in support of future extended-duration missions. The chosen materials were periodically evaluated by nuclear magnetic resonance (NMR) spectroscopy, thermal desorption-coupled with gas chromatography/mass spectrometry (TD-GC/MS), and CO2 adsorption to assess long-term storage efficacy across various environmental storage conditions. NMR spectroscopy was utilized by extracting the active CO2 adsorbing chemical from the solid support with deuterated solvent and comparing the spectra over time for degradation and change. The solid adsorbents were also analyzed via TD-GC/MS to reveal any potential off-gassing chemicals over time. Additionally, XploSafe’s breakthrough test rig was utilized to dose the solid adsorbents with a 585 BTU/h metabolic rate flow-equivalent CO2 stream and monitored for 0–99% CO2 breakthrough. The performance metrics from the breakthrough analysis were compared over the storage study duration for CO2 removal and humidity control. Xplo-SA9T was evaluated for 24 months, whereas two additional adsorbent variants, MMPA-Sorbent and LPEI-Sorbent, were each evaluated for 12 months.

John R Tidwell

Physics-Based Modeling and Simulation of Emerging Battery Technologies for Aerospace

Recently there is a growing interest in the aviation sector to reduce air and noise pollution. Electrochemical energy storage devices such as batteries coupled with a distributed electric propulsion system can reduce noise concerns as well as emissions and allow the concept of Urban Air Mobility to come to fruition. The battery performance needs to improve considerably compared from current state-of-art Li-ion battery (about 200Wh/Kg) to realize all-electric passenger jet for short flights (up to 690 miles). NASA is exploring lithium-oxygen battery chemistry to power hybrid (battery powered electrical system) and all-electric aircraft for short distance and long-distance flights. Li-O2 is one of the advanced Li-ion technologies that promise to provide specific energy of more than 750Wh/Kg. For this presentation, we present our work on improving power density of Li-O2 batteries through the use of multiphysics simulations. Next, a path is outlined to port these model to simulate performance for a new battery chemistry for space application, Li-CO2. Li-CO2 uses carbon dioxide as the active material instead of oxygen. Although this technology is in its early development, the offers two benefits: it can be used as a CO2 scrubber, as oxygen is one of the by-products on charging, and as a backup or a standalone battery for various Mars or Venus missions, where the carbon dioxide content in the atmosphere is high and need battery to operate at higher temperatures.

Mehta, Mohit

Coma Physics of an Interstellar Object: JWST Spatial-Spectral Mapping of 3I/ATLAS

We report a survey of molecular emission from cometary volatiles using the James Webb Space Telescope (JWST) toward interstellar object 3I/ATLAS carried out on UT 2025 December 22 and 23 at a heliocentric distance (\rh{}) of $2.37-2.41$ au. These measurements of CO, \ce{CO2}, \ce{H2O}, \ce{CH3OH}, and \ce{CH4} sampled molecular chemistry in 3I/ATLAS as it receded from its encounter with our Sun and entered the vicinity of the \ce{H2O} ice line --- the region between \rh{} = $2-3$ au where the temperature becomes too low for H$_2$O to vigorously sublime and CO and \ce{CO2} begin to control the overall activity. CO was the most abundant molecule, followed by \ce{H2O} and \ce{CO2}, whose molecular abundances with respect to CO were $(40.5\pm3.1)\%$ and ($41.6\pm0.3)\%$, respectively. This work presents spatial-spectral maps of column density and rotational temperature as a function of distance from the nucleus for all detected species. The spatial distributions of both quantities were highly anisotropic for the apolar species in the coma of 3I/ATLAS, yet were more nearly symmetric for the polar molecules. These results demonstrate how volatiles were segregated in the nucleus ices of 3I/ATLAS and reveal heating and cooling mechanisms in its coma. Derived maps of the ortho-to-para ratio (OPR) for \ce{H2O} were flat with increasing distance from the nucleus and consistent with a coma-averaged value $\mathrm{OPR}=2.7\pm0.2$, slightly less than the expected equilibrium value of three.

Nathan X Roth

A Comparison of Doppler Lidar Wind Sensors for Earth-Orbit Global Measurement Applications

Now, there are four Doppler lidar configurations which are being promoted for the measurement of tropospheric winds: (1) the coherent CO2 Lidar, operating in the 9 micrometer region using a pulsed, atmospheric pressure CO2 gas discharge laser transmitter, and heterodyne detection; (2) the coherent Neodymium doped YAG or Glass Lidar, operating at 1.06 micrometers, using flashlamp or diode laser optical pumping of the solid state laser medium, and heterodyne detection; (3) the Neodymium doped YAG/Glass Lidar, operating at the doubled frequency (at 530 nm wavelength), again using flashlamp or diode laser pumping of the laser transmitter, and using a high resolution tandem Fabry-Perot filter and direct detection; and (4) the Raman shifted Xenon Chloride Lidar, operating at 350 nm wavelength, using a pulsed, atmospheric pressure XeCl gas discharge laser transmitter at 308 nm, Raman shifted in a high pressure hydrogen cell to 350 nm in order to avoid strong stratospheric ozone absorption, also using a high resolution tandem Fabry-Perot filter and direct detection. Comparisons of these four systems can include many factors and tradeoffs. The major portion of this comparison is devoted to efficiency. Efficiency comparisons are made by estimating the number of transmitted photons required for a single pulse wind velocity estimate of + or - 1 m/s accuracy in the middle troposphere, from an altitude of 800 km, which is assured to be reasonable for a polar orbiting platform.

Robert T Menzies