Engineering PapersSearch

SEARCH · Engineering Papers

Results for “CMS experiment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Surface Tension Driven Convection Experiment (STDCE)

Results are reported of the Surface Tension Driven Convection Experiment (STDCE) aboard the USML-1 (first United States Microgravity Laboratory) Spacelab which was launched on June 25, 1992. In the experiment 10 cSt silicone oil was placed in an open circular container which was 10 cm wide by 5 cm deep. The fluid was heated either by a cylindrical heater (1.11 cm dia.) located along the container centerline or by a CO 2 laser beam to induce thermocapillary flow. The flow field was studied by flow visualization. Several thermistor probes were placed in the fluid to measure the temperature distribution. The temperature distribution along the liquid free surface was measured by an infrared imager. Tests were conducted over a range of heating powers, laser beam diameters, and free surface shapes. In conjunction with the experiments an extensive numerical modeling of the flow was conducted. In this paper some results of the velocity and temperature measurements with flat and curved free surfaces are presented and they are shown to agree well with the numerical predictions.

S Ostrach

Evaluation of 3D pixel silicon sensors for the CMS Phase-2 Inner Tracker

The high-luminosity upgrade of the CERN LHC requires the replacement of the CMS tracking detector to cope with the increased radiation fluence while maintaining its excellent performance. An extensive R&D program, aiming at using 3D pixel silicon sensors in the innermost barrel layer of the detector, has been carried out by CMS in collaboration with the FBK (Trento, Italy) and CNM (Barcelona, Spain) foundries. The sensors will feature a pixel cell size of 25 × 100 µm 2 , with a centrally located electrode connected to the readout chip. The sensors are read out by the RD53A and CROCv1 chips, developed in 65 nm CMOS technology by the RD53 Collaboration, a joint effort between the ATLAS and CMS groups. This paper reports the results achieved in beam test experiments before and after irradiation, up to a fluence of approximately 2 . 6 × 1 0 16 n eq /cm 2 . Measurements of assemblies irradiated to a fluence of 1 × 10 16 n˙eq/cm 2 show a hit detection efficiency higher than 96% at normal incidence, with fewer than 2% of channels masked, across a bias voltage range greater than 50 V . Even after irradiation to a higher fluence of 1.6 × 10 16 n˙eq/cm 2 , similar performance is maintained over a bias voltage range of 30 V , remaining well within CMS requirements.

3D pixel

Erosion Results of the MISSE 9-15 Polymers and Composites Experiment 1-4 (PCE 1-4)

Polymers and other oxidizable materials on the exterior of spacecraft in the low Earth orbit (LEO) space environment can be eroded from reaction with atomic oxygen (AO). Therefore, in order to design durable spacecraft it is important to know the extent of erosion that will occur during a mission. This can be determined by knowing the LEO AO erosion yield, E y (volume loss per incident oxygen atom), of materials susceptible to AO reaction. In addition, recent flight experiments have shown that the AO E y can vary with the AO fluence and/or solar exposure. Therefore, obtaining AO E y data for materials flown on various spaceflight missions is important. NASA Glenn Research Center has flown numerous experiments as part of the Materials International Space Station Experiment (MISSE) missions on the exterior of the International Space Station (ISS) to characterize the LEO E y of polymers, composites, protective coatings, and other spacecraft materials. Recently, four Glenn experiments with 365 flight (F) samples were flown on ISS’s MISSE-Flight Facility (MISSE-FF). These experiments are the Polymers and Composites Experiment-1 (PCE-1) flown as part of the MISSE-9 mission, the PCE-2 flown as part of the MISSE-10 mission, the PCE-3 flown as part of the MISSE-12 and MISSE-15 missions, and the PCE-4 flown as part of the MISSE-13 mission. Although each experiment had numerous sample objectives, the primary objective was to determine the LEO AO E y of various spacecraft materials as a function of solar irradiation and AO fluence. This paper provides a summary of the erosion data for the PCE 1-4 AO E y samples. The AO E y for 150 samples flown in either the LEO ram, wake, zenith or nadir directions are provided. The AO ram fluence varied from 2.97×10 20 atoms/cm 2 after 0.89 years of direct space exposure (with relatively high levels of Si contamination) on MISSE 12 to 3.93×10 20 atoms/cm 2 after 1.17 years of direct space exposure on MISSE-10. The ram AO E y values for uncoated polymers range from 3.81×10 –25 cm 3 /atom for polytetrafluoroethylene (M9R-C20 F) exposed to an AO fluence of 3.44×10 20 atoms/cm 2 on MISSE-9 to 4.43×10 –23 cm 3 /atom for AO etched low density polyimide aerogel (M12R-C21 F) exposed to an AO fluence of 2.97×10 21 atoms/cm 2 on MISSE-12. Because of the low AO fluence and relatively high Si contamination, a number of PCE-3 wake samples experienced mass gain. Thus, AO E y values are not provided for these samples. Although there are calculated AO E y values for the zenith, wake and nadir samples, the ram AO E y for a particular material is a more reliable value in terms of AO exposure because the zenith, wake and nadir directions were exposed to either no or very little AO fluence and thus other space environmental factors (i.e. vacuum, thermal extremes and thermal cycling, and/or various types of radiation) are responsible for the mass loss.

Erosion yield

Assembly and Testing of Scintillator Tile Modules for the CMS High-Granularity Calorimeter Upgrade

The High-Granularity Calorimeter (HGCAL), part of the upgrade to the Compact Muon Solenoid (CMS) experiment, employs silicon and scintillator tile modules in the endcaps to maintain detector performance during the High-Luminosity Large Hadron Collider (HL-LHC) era, scheduled to operate from 2030 to 2040. The upgraded calorimeter will provide highly segmented three-dimensional imaging, energy measurements, and precise timing for particle shower reconstruction. Approximately half of the HGCal plastic scintillator tile modules (1,834 total) will be assembled at Fermilab using an automated pick-and-place (PnP) machine. Following assembly, each tile module undergoes quality control (QC) procedures such as electrical validation, thermal testing, and physics validation using cosmic rays. This poster/talk presents the QC procedures and results from the tile module production in 2026, demonstrating the performance and quality of the assembled tile modules.

Bazimya, Jean Luc [Grambling State U.]

The Study of Dopant Segregation Behavior During the Growth of GaAs in Microgravity

An investigation into the segregation behavior of selenium doped gallium arsenide during directional solidification in the microgravity environment was conducted using the Crystal Growth Furnace (CGF) aboard the first United States Microgravity Laboratory (USML-1). The two crystals grown were 1.5 cm in diameter and 16.5 cm in length with an initial melt length of 14 cm. Two translation periods were executed, the first at 2.5 microns/s and after a specified time, which was different between the two experiments, the translation rate was doubled to 5.0 microns/s. The translation was then stopped and the remaining sample melt was solidified using a gradient freeze technique in the first sample and a rapid solidification in the second experiment. Measurement of the selenium dopant distribution, using quantitative infrared transmission imaging, indicates that the first sample initially achieved diffusion controlled growth as desired. However, after about 1 cm of growth, the segregation behavior was driven from a diffusion controlled growth regime to a complete mixing regime. Measurements in the second flight sample indicated that the growth was always in a complete mixing regime. In both experiments, voids in the center line of the crystal, indicative of bubble entrapment, were found to correlate with the position in the crystal when the translation rates were doubled.

D H Matthiesen

Air-Broadened Line Shapes in the 2n3 R Branch of 12ch4 Between 6014 and 6100 cm-1

Complete and accurate information on line shape parameters of 2?3 methane transitions for air broadening as a function of temperature is critical not only for the correct interpretation of the observed atmospheric spectra but also for the development of a reliable theoretical model. For this reason, we obtained a series of high-resolution, high S/N spectra of high-purity 12CH4 and 12CH4 broadened with dry air at temperatures in the 130 to 295 K range using the Bruker IFS 125HR Fourier transform spectrometer at JPL. Two absorption cells were used in the experiment, a White cell with path length of 13 m for room temperature spectra and a 21 m Herriott cella for cold sample spectra. The 15 spectra used in the analysis consisted of 3 low pressure (0.26 to 2.57 Torr) spectra with pure 12CH4 and 12 air-broadened spectra with total sample pressures of 79-805 Torr and volume mixing ratios of methane between 0.23 and 1%. A multispectrum least-squares fitting techniqueb was employed to fit all 15 spectra simultaneously. Preliminary results for select R(J) manifolds will be presented.

V Malathy Devi

Staged Z-pinch experiment at the double-EAGLE pulsed power facility

The staged Z-pinch is a potential high-energy gain fusion concept where a high atomic number liner implodes on a deuterium target using a pulsed multi-MA current source. Over the past several years this concept has been studied on 0.5–1.0 MA facilities using Ar and Kr gas puffs injected at R = 1.2 cm. Neutron yield up to (2.5 ± 0.34) x 10 10 was measured, Ruskov et al (2023 IEEE Trans. Plasma Sci. 51 3310–6). Here, in this study, we present experimental results from the 4 MA, 110 ns current rise time Double-EAGLE facility at L3Harris (currently, Fisica Inc.) where a larger radius nozzle created gas density profiles peaked at R = 2.5 cm. Modeling with the MACH2 and FLASH codes indicates that the larger radius allows stronger acceleration of the liner plasma and generation of shock waves that preheat a target plasma layer next to the liner to temperatures $T_i >$1 keV. The resulting counter thermal pressure on the liner plasma limits the growth of the Magneto-Rayleigh–Taylor (MRT) instability at the liner-vacuum boundary and the implosion proceeds in a relatively stable manner. Near bang time the enormous target plasma thermal pressure smoothens the MRT perturbations developed during the earlier implosion stages. Time integrated x-ray pinhole images with cutoff energy of 100 eV confirm that a long (∼3 cm), stable and uniform high energy density plasma column is formed in the final implosion stage. Consistent neutron yield in the 10 10 –10 11 range was measured for both Ar and Kr liners imploding on a deuterium target.

Physics - Plasma physics

Improved Treatment of Global Positioning System Force Parameters in Precise Orbit Determination Applications

Data collected from a worldwide 1992 experiment have been processed at JPL to determine precise orbits for the satellites of the Global Positioning System (GPS). A filtering technique has been tested to improve modeling of solar-radiation pressure force parameters for GPS satellites. The new approach improves orbit quality for eclipsing satellites by a factor of two, with typical results in the 25- to 50-cm range. The resultant GPS-based estimates for geocentric coordinates of the tracking sites, which include the three DSN sites, are accurate to 2 to 8 cm, roughly equivalent to 3 to 10 nrad of angular measure.

Y Vigue

Lunar Electrical Conductivity, Permeability and Temperature From Apollo Magnetometer Experiments

Magnetometers have been deployed at four Apollo sites on the Moon to measure remanent and induced lunar magnetic fields. Measurements from this network of instruments have been used to calculate the electrical conductivity, temperature, magnetic permeability, and iron abundance of the lunar interior. The measured lunar remanent fields range from 3 gammas (γ) minimum at the Apollo 15 site to 327 γ maximum at the Apollo 16 site. Simultaneous magnetic field and solar plasma pressure measurements show that the remanent fields at the Apollo 12 and 16 sites interact with, and are compressed by, the solar wind. Remanent fields at Apollo 12 and Apollo 16 are increased 16 γ and 32 γ, respectively, by a solar plasma bulk pressure increase of 1.5 x 10 -7 dynes/cm 2 . Global lunar fields due to eddy currents, induced in the lunar interior by magnetic transients, have been analyzed to calculate an electrical conductivity profile for the Moon. From nightside magnetometer data in the solar wind it has been found that deeper than 170 km into the Moon the conductivity rises from 3 x 10 -4 mhos/m to 10 -2 mhos/m at 1000-km depth. Recent analysis of data obtained in the geomagnetic tail, in regions free of complicating plasma effects, yields results consistent with nightside values. Conductivity profiles have been used to calculate the lunar temperature for an assumed lunar material of olivine. In the outer layer (~ 170 km thick) the temperature rises to 110° C, after which it gradually increases with depth to 1500° C at a depth of ~ 1000 km. Simultaneous measurements by magnetometers on the lunar surface and in orbit around the moon are used to construct a whole-moon hysteresis curve, from which the global lunar magnetic permeability is determined to be μ = 1.012 ± 0.006. The corresponding global induced dipole moment is 2 x 10 18 gauss-cm 3 for typical inducing fields of 10 -4 gauss in the lunar environment. Lunar free iron abundance corresponding to the global permeability is determined to be 2.5 ± 2.0 wt. %. Total iron abundance (sum of iron in the ferromagnetic and paramagnetic states) is calculated for two assumed compositional models of the lunar interior. For a free iron/orthopyroxene lunar composition the total iron content is calculated to be 12.8 ± 1.0 wt. %; for a free iron/olivine composition, total iron content is 5.5 ± 1.2 wt. %. Other lunar models with an iron core and with a shallow iron-rich layer are also discussed in light of the measured global lunar permeability. Velocities and thicknesses of the Earth's magnetopause and bow shock have been estimated from simultaneous magnetometer measurements. Average speeds are determined to be about 50 km/s for the magnetopause and 70 km/s for the bow shock, although there are large variations in the measurement for any particular boundary crossing. Corresponding measured boundary thicknesses average about 2300 km for the magnetopause and 1400 km for the bow shock.

P Dyal

Mechanics and Cooling of the CMS Phase-II Tracker Barrel

The CMS upgrade for the High-Luminosity LHC (HL-LHC) era will allow for an incredibly high rate of data collection, to be used in the next generation of precision measurements and searches for beyond the standard model physics. A key element of this upgrade is the full replacement of the silicon strip tracker to enable level-1 triggering on track level primitives, produced by pixel-strip (PS) and strip-strip (2S) modules, tiled together to form the new detector. Mechanically supporting and cooling these modules is not trivial, as material budget in the tracker volume is highly constrained, and as the modules accrue radiation damage they risk becoming entirely non-functional if the silicon sensors are not sufficiently cooled. To address this, each region of the tracker has a bespoke solution for housing and cooling their modules, mostly depending on carbon-fiber and carbon-foam structures, with dual phase CO2 cooling. For the most central part of the tracker, the Flat Barrel with PS modules (Flat TBPS) covers the pseudorapidity range out to $|\eta|=0.4$, and the mechanical structures are manufactured, assembled, and tested entirely by Fermilab and UC Davis. This presentation will describe the intense design and testing requirements for these components, and how they will ensure strong performance of the tracker through the HL-LHC era.

Cosby, Christopher [Fermilab]