ARC-SAFE: Accelerated Response semiconducting Contactors and Surge Attenuation For DC Electrical systems (Final Scientific/Technical Report)

The landscape of power transmission and distribution is quickly evolving as more power conversion is done through power electronics and transmitted or distributed at medium voltage direct current (MVDC). As power electronics tend to store less energy and be less resilient to faults than conventional power transformers, a reliable and fast protection against faults is critical to protect power electronics (PE) based infrastructure, especially for medium- and high-voltage applications. This motivates the development of PE based protection circuits to replace slower contemporary electromechanical breakers. In this project a novel PE based MVDC circuit breaker is developed; the new design is comprised of 1) a normally-on leg made of commercially-available, cascaded SiC junction field effect transistors (JFETs) with a passive balancing network, and 2) a normally-off leg based on an optically-triggered gallium nitride (GaN) photoconductive semiconductor switch (PCSS). The normally-off leg was designed to be quickly turned on, to divert current to an auxiliary dissipative circuit, as the normally-on leg is turned off. This approach, using solid-state devices, was selected for a high-performance, fast-switching operation for the DC circuit breaker as compared to approaches that use slower mechanical switches. To be practical, the circuit breaker must have low conduction loss (low Ron) in the normally-on leg and fast coordinated triggering of the normally-off leg to avoid damage from inductive flyback, which could be considerable for long lengths of cable.

24 POWER TRANSMISSION AND DISTRIBUTION

A Parametric Reduced-Order Model for Inverter Short-Circuit Response in Protection Studies

This paper presents a reduced-order model (ROM) for grid-following (GFL) inverters that reproduces inverter fault current trajectories, including sub transients, transient, and steady-state phases, across a range of fault types, locations, and pre-fault operating points. . The proposed model is developed by: Constructing the positive- and negative-sequence current with parameterization fitted by large data training and fitting Validating using EMT simulation against EMT full model and demonstrating the ROM's capability to capture fault current magnitude, phase angle, and oscillatory transients. Building a standard EMT simulation platform library component for easy configuration and application.

24 POWER TRANSMISSION AND DISTRIBUTION

Grid Forming Inverter With Increased Short-Circuit Contribution to Address Inverter-Based Microgrid Protection Challenges

Substantial differences in fault levels between grid-tied and islanded modes is one of the primary challenges of microgrid protection. During grid-tied mode, the bulk grid provides significant short-circuit, while during islanded operation the short-circuit magnitude is small due to inverter-based resources limiting their current output close to nominal ratings. Consequently, conventional distribution protection strategies based on overcurrent cannot reliably protect microgrids when operating in islanded mode. Fuses and circuit breakers are particularly affected because of their inverse characteristics. Presently, the absence of affordable solutions for protecting microgrids in islanded mode leads to microgrids shutting down during electrical faults. The contribution of this article is two-fold. The first innovation proposes specific hardware modifications to grid-forming inverters to increase their short-circuit current during electrical faults. The second innovation introduces a novel control strategy designed to preserve control stability margins even when the grid-filter saturates, ensuring sinusoidal output currents under normal and fault conditions. Through experimental results, the inverter with the proposed modifications can provide more than three-times its nominal current during electrical faults. For the prototype testbed, this was sufficient to enable the use of traditional legacy overcurrent protection, achieving the fuse-to-relay and relay-to-relay minimum coordination time for the line-to-ground, line-to-line to ground, and three-phase electrical faults.

42 ENGINEERING

Method for Coupled Electromagnetic and Circuit Simulations to Evaluate Surge Arrester Performance in Protecting Equipment Against E1 HEMP

Surge arrester behavioral modeling for realistic systems embedded in an E1 high-altitude electromagnetic pulse environment inherently encompasses three interconnected complications: (1) the need to account for signal propagation across two domains, electromagnetics and electrical; (2) the need to include both linear and nonlinear circuit components in the analysis; and (3) the need to understand that the over-current and over-voltage mitigation performance is dependent not only on the properties of the surge arrester and protected load but also on the topology of the overall electrical network. This study presents a framework to address these challenges in a systematic manner to consider the effectiveness of protective measures for a common class of equipment in power generation facilities. Full-wave simulations were carried out to derive circuit-domain (i.e., lumped element–based) equivalent models for the excitation waveform and the physical components of the system. Then, these equivalent models were imported to a circuit solver and combined with a high-frequency surge arrester model to evaluate mitigation performance. The methodology outlined is general enough such that it can be applied for other electromagnetic interference problems that involve E2/E3 HEMP or microwave emissions.

42 ENGINEERING

Non-Markovian relaxation spectroscopy of fluxonium qubits

Recent studies have shown that parasitic two-level systems (TLS) in superconducting qubits, which are a leading source of decoherence, can have relaxation times longer than the qubits themselves. However, the standard techniques used to characterize qubit relaxation is only valid for measuring T 1 under the Born-Markov approximation and could mask environmental memory effects in practice. Here, we introduce two-timescale relaxometry, a technique to probe the qubit and environment relaxation simultaneously and efficiently. We apply it to high-coherence fluxonium qubits over a frequency range of 0.1-0.4 GHz, and reveal a discrete spectrum of TLS with millisecond lifetimes. Our analysis of the spectrum is consistent with a random distribution of TLS in the aluminum oxide tunnel barrier of the Josephson junction chain of the fluxonium, with a spectral and volumetric density and average electric dipole similar to previous TLS studies at much higher frequencies. Our study suggests that investigating and mitigating TLS in the junction chain is crucial to the development of various types of noise-protected qubits in circuit QED.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Magnetic flux imaging in a 3D superconductor integrated circuit

We report on imaging magnetic flux distributions in a multilayered superconductor integrated circuit which emerge during magnetization and after field cooling of the circuit in the DC magnetic field. The obtained complicated field maps expose the flux propagation across the patterned superconducting ground planes sandwiching layers with Josephson junction-based logic cells, fine wire grid around the functional units, and multiple superconducting fill structures located in different inner layers. The observed intricate flux distributions are explained by specific patterns of Meissner screening currents and superconducting critical currents in different mutually interacting parts of the integrated circuit. Our results provide important insights into possible ways of improving the protection of superconductor integrated circuits from magnetic fields and their resilience against flux trapping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Assessing Inverter-Based Resources Modeling Gaps in Commonly Used Short-Circuit Programs

Future bulk power systems are expected to operate with a high penetration of inverter-based resources (IBR). This is anticipated to fundamentally change the system’s short-circuit behaviors and demand a change in existing transmission line protection settings or schemes. Phasor-domain short circuit programs (e.g., ASPEN, CAPE, and CYME) remain the mainstream tools for developing protection settings. However, the system protection community has shared concerns about the accuracy of IBR models in short-circuit programs. This report compares the performance of existing generic IBR models in short-circuit programs with detailed electro-magnetic transient (EMT) models provided by several different IBR manufacturers in PSCAD, to quantify the short-circuit program’s IBR model accuracy, assess their ability to replicate individual IBR controls such as negative sequence current injections, and identify specific gaps in the existing generic phasor-domain IBR models that are currently available.

42 ENGINEERING

Magnetic brightening and nanoscale imaging of spin-polarized helical edge modes in ZrTe 5

Efficient charge transport remains a fundamental challenge for nanoelectronic devices, as their performance is constrained by high dissipation and the impedance mismatch between high-frequency signal sources and nanoscale circuit interfaces. Although topologically protected helical edge modes offer a dissipationless and backscattering-resilient alternative, achieving nanoscale control over these modes requires direct visualization of their spatial electrodynamics, especially under high-frequency operation. Here, by utilizing cryogenic magneto-infrared scattering-type scanning near-field optical microscopy (cm-IR-sSNOM), we image spin-polarized helical edge channels in ZrTe 5 at the nanoscale, revealing magnetic-field-induced brightening as a high-frequency electrodynamic signature of robust topological edge modes. Operating at 1.8 K and under a magnetic field of up to 5 T, we observe the emergence of edge-state polarizability at infrared frequencies that is notably resilient to the magnetic gaps that typically quench d.c. and microwave edge transport. Our results reveal a topological ‘two-lane’ spatial reorganization in which an external magnetic field induces a spin-population imbalance between counterpropagating edge modes. Favoured helical branches are confined against physical boundaries to activate a net infrared near-field contrast. This electrodynamic response scales linearly with the number of atomic layers, which confirms that individual layers in ZrTe 5 preserve their discrete quantum spin Hall identities. These findings may be useful for developing topological spintronic devices, as the magnetic infrared tunability of helical edge channels provides a pathway for low-loss nanoscale interconnects and high-speed information processing.

36 MATERIALS SCIENCE

Reduction of Methane Leaks through Corrosion Mitigation Pre-treatments for Pipelines with Field Applied Coatings

Corrosion of buried, coated steel pipelines transporting natural gas is a significant source of methane emissions, from pipeline venting required for maintenance and repairs and from pipeline leaks and incidents. Corrosion of steel under field applied coatings is an important safety concern for the pipeline industry. This project investigates the application of a field applied alloy over girth welds to mitigate external corrosion of buried coated steel pipelines. Various metallic coating options were considered, which were required to meet several criteria: (1) it must resist corrosion under open-circuit or mild cathodic protection conditions, (2) it must protect the substrate steel, and (3) it must not negatively affect the adhesion of the field coating. Finite element models and lab testing were performed of alloy coating compositions to identify promising alloy types underneath disbonded coatings. Polarization curves of coating alloys were generated to provide the boundary conditions for the COMSOL model to compute potential and current distributions around coated areas. Sacrificial and corrosion-resistant metal alloy coatings were evaluated and optimized using corrosion modeling and laboratory electrochemical testing, where aluminum alloy 5356 (5% Mg) and steel alloy B9 (9% Cr) were selected. Corrosion test coupons were designed and fabricated using thermal spray aluminum 5356 and welded B9 steel overlays on API 5L grade X42 line pipe steel. The corrosion test coupons, with simulated pipe coating damage, were tested in a laboratory soil box and a field pipeline site in Texas for 3-months. Corrosion test coupons were then tested for 6-months at field pipeline sites in Texas and Tennessee to quantify corrosion rates and performance of the aluminum and steel alloys under polyethylene tape and 2-part epoxy coatings, various coating holidays, and with and without cathodic protection.

03 NATURAL GAS

Simple Battery Hazard Calculator

SAND2025-00455O Simple Battery Hazard Calculator is a software tool developed in Excel to analyze the electrical hazards of battery systems and determine the required personal protective equipment (PPE) for safe assembly and disassembly. It calculates potential arc flash incident energy, contact thermal hazard level, and recommends PPE based on parameters such as voltage, short circuit current, and over current protection trip time. The calculator uses a recognized method for calculating arc flash incident energy, which was previously inaccessible to most battery workers. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Rosewater, David

Cathodic Protection Modeling for Hanford Underground Double-Shell Tank Farms

Hanford stores millions of gallons of radioactive and chemically hazardous waste from the production of weapon materials in tank farms consisting of underground carbon-steel storage tanks surrounded by reinforced concrete. Six of these Hanford tank farms use double-shell storage tanks (DSTs). The DST farms were constructed from 1968 to 1986 with a planned 40–50 year design life, so some are already operating beyond their initial life expectancy. Ultrasonic testing (UT) has indicated significant thinning on the bottom of the secondary (outer) liner of these tanks, believed to arise from groundwater intrusion driving concrete side corrosion. There is no direct access to the steel/concrete interface between the tank and the concrete pad, making it difficult to apply a chemical-based mitigation strategy or to conduct repairs, but cathodic protection (CP) is a possible method to inhibit further concrete-side corrosion. Hanford already uses CP to protect below grade steel piping within the tank farms and connected to the tanks, but this system was not designed to protect the tank bottoms. CP design must account for the structures surrounding the DSTs, including the steel reinforcing bars (rebar) within the concrete pad and vault, various process lines, and the existing CP system. In this study, finite element analysis (FEA) modeling was carried out to simulate CP protection of 1) a single tank and CP anode to develop options for modeling the rebar and to compare to a simpler circuit model and 2) the entire Hanford AN tank farm as a representative example consisting of seven tanks, associated piping, and both existing and new CP anodes. Both circuit and FEA models predict that significant protective current could be delivered to the bottoms of the tanks with the addition of tank-protection anodes below the depth of the tanks. Simulations with only the existing pipe-protection anodes active confirmed that only a very small current to the tank bottoms is predicted under present conditions. Multiple simplified representations of the dome and wall rebar were tested to reduce the computational complexity of the tank-farm simulations, resulting in modeling the rebar as edge elements with a prescribed effective circumference that matches the real rebar surface area. The geometry of the rebar is also simplified into horizontal hoops around the tank walls and radial rebar over the dome with increased effective circumference to retain the target surface area. This simplification was found to greatly reduce the complexity and solution time of the models without large changes in current distributions, especially to the tank bottom. A range of values were tested for model parameters such as soil and concrete resistivities and polarization resistance to investigate their impact on the current and electric potential distributions. Depending on the parameters used, FEA simulations predict some risk of overprotection, particularly on the piping system; since overprotection can also lead to surface damage associated with hydrogen gas generation at the interface (e.g. hydrogen embrittlement or damage to coatings), this needs to be considered when refining the design of the new CP system. Comparison between the FEA models and the circuit model representation demonstrated that the circuit model could not match the predicted FEA current distribution, even when using the exact same surface areas. This discrepancy appeared to be at least partly attributable to the impact of the relative positions of the tank components and anodes to each other and to the ground surface. The FEA model accounts for the relative positions since it solves the governing equations in three dimensions, but the circuit model cannot account for the positioning. In particular, the circuit model underpredicts the current to the tank bottom and overpredicts the current to the dome compared to FEA for the baseline geometry. The FEA models omitted the electrically isolated rebar in the bottom concrete slab. However, a circuit based stray current model estimated that only 2.1% of the total current through the slab would stray into the rebar, corresponding to ~0.21 A for a target current density of 2 mA/ft2 to the tank bottom. The estimated corrosion driven by this amount of stray current is predicted to yield a lifetime of >400 years for the minimum rebar diameter, assuming an acceptable cross-section area loss of 10%.

d'Entremont, Anna [Savannah River National Laborat

Searching for Grid-Forming Technologies That Do Not Impact Protection Systems: A promising technology

The design of legacy-line protection elements has been guided by the behavior of synchronous machines during faults. Because of the significant field-winding inductance and rotating mass, the magnitude, angular frequency, and phase angle of the back-electromotive force (EMF) voltage waveforms of synchronous machines remain practically constant for several hundreds of milliseconds after a fault occurs. Furthermore this has facilitated the engineering of the memory-polarization technique in mho distance elements, which has been effective for machine-dominant power grids. However, this assumption is no longer held for inverter-based resources (IBRs) because of the lack of field winding and moment of inertia in power electronics devices. Notably, the negative-sequence directional overcurrent protection and the quadrilateral distance elements have been impacted by early IBRs with grid-following (GFL) controls because they did not inject negative-sequence currents during asymmetrical faults.

24 POWER TRANSMISSION AND DISTRIBUTION

Nondegenerate Noise-Resilient Superconducting Qubit

We propose a superconducting qubit based on engineering the first and second harmonics of the Josephson energy and phase relation 𝐸 𝐽⁢1 ⁢cos 𝜑 and 𝐸 𝐽⁢2 ⁢cos 2⁢𝜑. By constructing a circuit such that 𝐸 𝐽⁢2 is negative and |𝐸 𝐽⁢1 | ≪ |𝐸 𝐽⁢2 |, we create a periodic potential with two nondegenerate minima. The qubit, which we dub “harmonium,” is formed from the lowest-energy states of each minimum. Bit-flip protection of the qubit arises due to the localization of each qubit state to their respective minima, while phase-flip protection can be understood by considering the circuit within the Born-Oppenheimer approximation. We demonstrate with time-domain simulations that single- and two-qubit gates can be performed in approximately 100 ns. Finally, we compute the qubit coherence times using numerical diagonalization of the complete circuit in conjunction with state-of-the-art noise models. We estimate out-of-manifold heating times on the order of milliseconds, which can be treated as erasure errors using conventional dispersive readout. We estimate pure-dephasing times on the order of many tens of milliseconds, and bit-flip times on the order of seconds.

quantum error correction

A Review on Protection Challenges on Transmission Lines Connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses. Utilities, university researchers, research institutes, and relay manufacturers have performed studies to investigate different aspects of high IBR penetration. Almost all studies support 1) creating international and national standards to regulate the IBRs, 2) revising engineering tools to address shortcomings, and 3) adjusting the protective relay settings to resolve protection problems. This paper summarizes the studies and research conducted in recent years to quantify the impact of IBR penetration on transmission line protection and to identify potential solutions to improve the dependability and reliability of grid protection systems.

14 SOLAR ENERGY

A review on protection challenges of Transmission Lines connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses.

14 SOLAR ENERGY

A Review on Protection Challenges of Transmission Lines Connected to Inverter-Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses

14 SOLAR ENERGY

Evaluation of a Reduced-Order Model for IBR Fault Response Representation via OEM Blackbox Models: Preprint

Driven by the need to capture the electromagnetic transients of transmission lines, inverter switching behavior, and detailed control systems, electromagnetic transient (EMT) studies have become increasingly important in industry, such as IBR interconnection study and fault study. However, original equipment manufacturer (OEM) inverter models typically include extensive parameters and proprietary settings that are unavailable to protection engineers. This paper introduces a data-driven, reduced-order model (ROM) developed as a PSCAD library component for use in EMT-based fault studies. The ROM replicates key OEM model behaviors without requiring detailed knowledge of control design or parameterization. The accompanying Python automation scripts streamline data generation, parameter fitting, and validation. The ROM's performance is demonstrated through comparison with both IEEE 2800-compliant and non-compliant OEM models in a real-world power system. Relay responses show nearly identical results, while simulation runtime is reduced by an average of 32.8\%, highlighting the ROM's practicality for protection engineers.

14 SOLAR ENERGY