Engineering PapersSearch

SEARCH · Engineering Papers

Results for “CIM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

PNNL-CIM-Tools/EASY-CIM

Extracting Attributes in a Simple DictionarY of CIM (EASY-CIM) is a python library to reduce the time and burden of model queries using simplified data representations of CIM power system models.

Anderson, Alex

Positive and Negative Ion CIMS Measurements, SGP, May-June 2024

The negative ion measurements were taken using two LTOF-CIMS with two different nitrate inlets. The data labeled Aerodyne_Inlet used an Aerodyne nitrate inlet. Data labeled PCC used a custom transverse inlet. The positive ion measurements were taken using one LTOF-CIMS with hydronium as an ionization reagent using a custom transverse inlet with an inlet voltage difference of 700 V. See https://doi.org/10.1021/acs.jpca.2c01672 for more information. Peaks were autofit using tofware. Positive ion data is published in the form of peak signal/reagent signal. Data files of peak signal/reagent signal for the two mass spectrometers for the negative ion measurements are separate. Concentrations of H2SO4 are combined into one file. When measurements were overlapping, measurements from the Aerodyne nitrate inlet were used.

54 ENVIRONMENTAL SCIENCES

A Framework to Demonstrate a DNP3 Interface With a CIM-Based Data Integration Platform: Preprint

The contemporary electrical grid is characterized by its complexity and abundance of data. A control-rich environment supported by information and communication technologies within an Advanced Distribution Management System (ADMS) presents a viable and cost-effective option for utility companies aiming to implement advanced real-time analytical schemes for monitoring and remotely controlling distribution feeders. Modular platform-based approaches to distribution operations require a structured framework for acquiring field device measurements, performing analytics, converting the setpoint to the correct protocol, and sending it on the appropriate communications network to the field devices. We present the development and deployment of an application service to integrate an open-source standardsbased platform with an ADMS test bed with field devices using the Distributed Network Protocol (DNP3) for data exchange. The step-by-step procedure for establishing the DNP3-Master service on an open-source distribution platform is outlined, comprehensively explaining the Master setup process. Moreover, sample use case results highlight the capabilities of the DNP3- Master service setup. Results demonstrate the scalability and configurability of the DNP3-Master service, making it adaptable for integration with other relevant applications, thus providing potential opportunities for real-world field trials and real-time assessments.

ADMS

Variation Tolerant and Energy-Efficient Charge Domain Compute-in-Memory Array with Binary and Multi-Level Cell Ferroelectric FET

Here, in this work, we present a variation-tolerant and energy-efficient charge-domain Ferroelectric FET (FeFET) based Compute-in-Memory (CiM) array design that is compatible with both binary and multi-level cell memory sensing. We demonstrate that: 1) by exploiting FeFET as a nonvolatile switch, its high ON/OFF ratio in the subthreshold region can suppress the error introduced by the inaccurate ON state conductance, thus realizing robust CiM operations, unlike the current-domain CiM design where the computation results is highly sensitive to the device conductance variation; 2) by leveraging a dense dynamic random access memory (DRAM)-like 1FeFET1C cell structure, the proposed design benefits from the existing high density DRAM establishment while also significantly relaxing the capacitor retention and transistor leakage requirement; 3) the charge-domain CiM supports both binary FeFET with minimum overhead and MLC FeFET with tolerable latency for MLC state sensing, whose efficacy is validated experimentally on both cell-level and array-level; 4) the proposed CiM shows much better device variation resilience than conventional current-domain CiM, and also improves inference accuracy. Macro-level evaluation results demonstrate significantly higher energy efficiency and area efficiency compared to prior CiM works.

Duan, Jiahui [University of Notre Dame, IN (United

Chemical ionization mass spectrometry utilizing benzene cations for measurements of volatile organic compounds and nitric oxide

We evaluate the capability of chemical ionization mass spectrometry (CIMS) using benzene cations as reagent ions (benzene CIMS) for detecting atmospheric trace gases. We characterize the ionization pathways and product ion distributions for 27 analytes spanning diverse chemical classes. To interpret the complex ion chemistry involving two reagent ions (C 6 H$^{+}_{6}$ and (C 6 H 6 )$^{+}_{2}$) and multiple ionization pathways (charge transfer, proton transfer, adduct formation, and hydride abstraction), we introduce a thermodynamics-based framework that classifies analytes into three categories based on their ionization energy (IE), relative to those of benzene monomer (9.24 eV) and dimer (8.69 eV). Each class exhibits distinct ionization mechanisms and product ions. Analytes with IE smaller than 8.69 eV (low IE) undergo charge transfer with both reagent ions; analytes with IE between 8.69 and 9.24 eV (mid IE) undergo charge transfer with C 6 H$^{+}_{6}$ and potential adduct formation with (C 6 H 6 )$^{+}_{2}$; analytes with IE larger than 9.24 eV (high IE) could undergo adduct formation, proton transfer, or hydride abstraction. Analytes within each class also show similar sensitivity, enabling sensitivity estimation for compounds lacking calibration standards. In addition to volatile organic compounds (VOCs), benzene CIMS detects nitric oxide (NO) with a detection limit of 5 pptv for 1 min integration time, exceeding the performance of most commercial NOx analyzers. Field deployments in Chicago and St. Louis demonstrate good agreement with reference NO measurements. Isoprene measurements show good agreement with a co-located gas chromatography–photoionization detector (GC-PID) in St. Louis, but exhibit substantial positive bias in Chicago, likely due to interferences from anthropogenic VOCs in the polluted urban environment. These results highlight the potential of benzene CIMS for concurrent measurements of NO, VOCs, and their oxidation products using a single instrument, while also underscoring challenges in complex atmospheric conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Online characterization of primary and secondary emissions of particulate matter and acidic molecules from a modern fleet of city buses

The potential impact of transitioning from conventional fossil fuel to a non-fossil-fuel vehicle fleet was investigated by measuring primary emissions via extractive sampling of bus plumes and assessing secondary mass formation using the Gothenburg Potential Aerosol Mass (Go:PAM) reactor from 76 in-use transit buses. Online chemical characterization of gaseous and particulate emissions from these buses was conducted using chemical ionization mass spectrometry (CIMS) with acetate as the reagent ion, coupled with the Filter Inlet for Gases and AEROsols (FIGAERO). Acetate reagent ion chemistry selectively ionizes acidic compounds, including organic and inorganic acids, as well as nitrated and sulfated organics. A significant reduction (48 %–98 %) in fresh particle emissions was observed in buses utilizing compressed natural gas (CNG), biodiesels like rapeseed methyl ester (RME) and hydrotreated vegetable oil (HVO), and hybrid-electric HVO (HVO HEV ) compared to diesel (DSL). However, secondary particle formation from photooxidation of emissions was substantial across all the fuel types. The median ratio of particle mass emission factors of aged to fresh emissions increased in the following order: DSL buses at 4.0, HVO buses at 6.7, HVO HEV buses at 10.5, RME buses at 10.8, and CNG buses at 84. Of the compounds that can be identified by CIMS, fresh gaseous emissions from all Euro V/EEV (Enhanced Environmentally friendly Vehicle) buses, regardless of fuel type, were dominated by nitrogen-containing compounds such as nitrous acid (HONO), nitric acid (HNO 3 ), and isocyanic acid (HNCO), alongside small monoacids (C 1 –C 3 ). Notably, the emission of nitrogen-containing compounds was lower in Euro VI buses equipped with more advanced emission control technologies. Secondary gaseous organic acids correlated strongly with gaseous HNO 3 signals (R 2 =0.85–0.99) in Go:PAM, but their moderate to weak correlations with post-photooxidation secondary particle mass suggest that they are not reliable tracers of secondary organic aerosol formation from bus exhaust. Our study highlights that non-regulated compounds and secondary pollutant formation, not currently addressed in legislation, are crucial considerations in the evaluation of environmental impacts of future fuel and engine technology shifts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Understanding Reliability Trade-Offs in 1T-nC and 2T-nC FeRAM Designs

Ferroelectric random access memory (FeRAM) is a promising candidate for energy-efficient nonvolatile memory, particularly for logic-in-memory and compute-in-memory (CIM) applications. Among the available cell architectures, One-Transistor–n-Capacitor (1T-nC) and two-transistor–n-capacitor (2T-nC) FeRAMs each offer distinct trade-offs in density, scalability, and reliability. In this work, we present a comparative study of these two architectures under both dimensional scaling ( XY/Z shrinkage) and vertical integration (increasing stacked capacitors per cell). Using technology computer-aided design (TCAD) and circuit-level simulations, we analyze how scaling impacts ferroelectric capacitance, parasitic coupling, and floating-node (FN) dynamics, which together dictate sense margin (SM) and read stability. A key mitigation strategy—floating unselected capacitors—is applied to both architectures, effectively decoupling the SM from the number of stacked capacitors and enabling tractable analysis across scaling regimes. Results show that 1T-nC suffers more from charge sharing with the bitline (BL), while 2T-nC benefits from transistor isolation and stronger low-voltage sensing at the cost of increased area. By systematically evaluating these behaviors across scaling directions, this work establishes the reliability trade-offs of 1T-nC and 2T-nC cells and provides design guidelines for high-density, vertically integrated FeRAM systems.

1T-nC

Speciated non-methane hydrocarbon measurements at the Oliktok Point, AK AMF3 from February-March 2020

This dataset contains speciated non-methane hydrocarbon gas-phase mole ratio measurements at the Oliktok Point, AK AMF3 as measured by a Tofwerk Vocus-2R time-of-flight NO+ chemical ionization mass spectrometer (TOF-NO+-CIMS) coupled with an Aerodyne gas chromatograph (GC). Users of the data are asked to contact PI Pratt prior to use for consultation, best data use, discussion of co-authorship, and to ensure that the most up-to-date information is provided.

benzene

Real-Time Measurements of Gas-Phase Medium-Chain Chlorinated Paraffins Reveal Daily Changes in Gas-Particle Partitioning Controlled by Ambient Temperature

Chlorinated paraffins (CPs) are synthetic polychlorinated n-alkanes produced as mixtures of a range of C x Cl y H 2x–y+2 formulas. CPs have numerous industrial applications but are toxic, long-lived, and environmentally ubiquitous with environmental releases occurring throughout their production, use, and disposal. Short-chain chlorinated paraffins (SCCPs, C 10–13 ) have been regulated by the United States Environmental Protection Agency since 2009 and by the Stockholm Convention since 2017. SCCP regulation is expected to cause increased production of medium-chain chlorinated paraffins (MCCPs; C 14–17 ), which are currently under consideration for Stockholm Convention regulations. Thus, there is a need to improve the understanding of MCCP environmental transport, distribution, and fate. Existing measurements are limited in their spatial and temporal coverage. Measurements of CP atmospheric loading are particularly scarce. Historically, these measurements have required long sampling times, obscuring the temporal behavior of atmospheric CPs. We report real-time in situ measurements of 18 gas-phase MCCPs. These measurements were made in the United States Southern Great Plains with nitrate ion chemical ionization mass spectrometry (NO 3 –CIMS). Here, the estimated average lower-limit concentration of MCCPs is on the order of single-digit ng/m 3 . MCCP diel behavior is partially explained by gas-particle partitioning with implications for MCCP transport and lifetimes.

54 ENVIRONMENTAL SCIENCES

Direct high-altitude observations of 2-methyltetrols in the gas- and particle phase in air masses from Amazonia

We present direct observations of 2-methyltetrol (C 5 H 12 O 4 ) in the gas- and particle phase from the deployment of a Filter Inlet for Gases and Aerosols coupled to a Time-of-Flight Chemical Ionization Mass Spectrometer (FIGAERO-CIMS) during the Southern Hemisphere High Altitude Experiment on Particle Nucleation and Growth (SALTENA), which took place between December 2017 and June 2018 at the high-altitude Global Atmosphere Watch station Chacaltaya (CHC) located at 5240 m a s l in the Bolivian Andes. 2-Methyltetrol signals were dominant in a factor resulting from Positive Matrix Factorization (PMF) identified as influenced by Amazon emissions. We combine these observations with investigations of isoprene oxidation chemistry and uptake in an isolated deep convective cloud in the Amazon using a photochemical box model with coupled cloud microphysics and show that, likely, 2-methyltetrol is taken up by hydrometeors or formed in situ in the convective cloud, and then transported in the particle phase in the cold environment of the Amazon outflow and to the station, where it partially evaporates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Multistate resistance in TaN/(Hf,Zr)O 2 /Ta ferroelectric tunnel junctions

Ferroelectric tunnel junctions (FTJs) utilizing hafnium zirconium oxide (HZO) have emerged as promising non-volatile memory elements for microelectronics, compatible with back end of line (BEOL) complementary–metal–oxide semiconductor fabrication. This study investigates asymmetric electrode TaN/HZO/Ta devices with a 6 nm thick HZO layer as FTJs for multistate resistive memory applications. The individual FTJs exhibit a resistance ratio exceeding 10× when utilized as a binary state device, with pulsing between −1.7 and +1.4 V to set the high resistance state (HRS) and low resistance state (LRS), respectively. Following with reduced write voltage pulses allows the ferroelectric device to operate with a selection of over 32 distinct resistance states (2 5 bits) between the LRS and HRS. This work then explores the stability of the resistance states during write/read pulse cycling, along with the stability of the state after multiple read pulses. Accessing the multibit state shows stability within 50 reads with the binary state remaining stable for more than 4000 reads pulses. With their multistate tunability and versatility, FTJs hold promise as BEOL memory elements for compute-in-memory (CiM) arrays, binary digital memory, or weighted vector matrix multiplication applications with low power consumption during computations.

CMOS

GRIDAPPSD/distopf (33583-E)

DistOPF is an open-source Python package providing a three-phase, asymmetric optimal power flow (OPF) tool specifically designed for distribution systems. The key inventive features include: - Asymmetrical 3-phase OPF modeling for distribution systems with unbalanced phases - Comprehensive control optimization supporting both active (P) and reactive (Q) power control variables - Built-in visualization and validation tools - Standard test system benchmarking platform for algorithm development and comparison - Modular CSV-based input system using Pandas DataFrames for flexible model specification - Standard power distribution model importer enabling direct conversion from CIM and OpenDSS format to optimization-ready models - Multiple solve interface compatibility (PYOMO, CVXPY, SciPy) with automatic solver selection based on problem type

Gray, Nathan [Pacific Northwest National Laborator

TETA Autoresearch [SWR-26-089]

TETA Autoresearch is a template repository based on github.com/karpathy/autoresearch for AI-assisted research science in the TETA group in the Center for Integrated Mobility Sciences (CIMS) center at the National Laboratory of the Rockies. This software is a template for running autonomous research experiments that iteratively improve an ML model for a single optimization objective. Two execution modes share one harness: LLM mode - an agent (e.g. Claude Code) edits a scaffold train.py one change at a time, tagging each experiment, logging reasoning, and pushing results. Defined by program.md. Optimizer mode - an Optuna-backed driver (TPE / CMA-ES / Random) iterates over a domain-defined search space. Defined by optimizers/. RouteE (vehicle energy prediction) is the reference domain under domains/routee/. Adding a new domain is mechanical - see EXTENDING.md.

Reinicke, Nicholas [National Laboratory of the Roc

CROCUS Air Quality Dataset from the University of Illinois Chicago (UIC), July 2024

This dataset was collected by the measurement system in the Atmosphere, Climate, and Ecosystems (ACE) Lab at the University of Illinois Chicago (UIC) from July 12 to July 31, 2024, as part of the Community Research on Climate and Urban Science (CROCUS) Urban Integrated Field Laboratory (UIFL) project, led by Argonne National Laboratory.To enhance understanding of urban air quality dynamics in Chicago, and as part of the CROCUS 2024 Urban Canyon Intensive Observation Period (IOP), several instruments were set up to provide continuous measurements of air quality parameters in Chicago during July 2024. These measurements cover both aerosols and gas-phase species. It focuses on particle size distribution (2.5–478 nm) measured by two Scanning Mobility Particle Sizers (SMPS) at a 4-min resolution, total particle number concentrations at a 1-s resolution, and chemical composition from a High-Resolution Time-of-Flight Aerosol Mass Spectrometer (AMS) at a 1-min resolution. Key gas-phase species, including NO, NO₂, SO₂, and O₃, are measured at a 1-min resolution, along with high-resolution NO and dimethyl sulfide (DMS) data from a Chemical Ionization Mass Spectrometer (CIMS). Volatile organic compound (VOC) data for toluene, isoprene, and benzene are provided by a GC-PID with a time resolution of 25 minutes.The data are formatted as NetCDF (.nc) files, making them easily accessible using common software such as MATLAB, R, and Python. Each parameter is stored in an individual dataset, which includes detailed instrument information in the header, as well as the corresponding sample start time and concentration/distribution data for each sample.

54 ENVIRONMENTAL SCIENCES

Analysis Report for Hydrolyzed UF 6 Samples

Under the auspices of the US Department of Energy/National Nuclear Security Agency’s Nuclear Reference Material Program (NRMP), the Material Signatures and Isotopic Standards (MSIS) group of Oak Ridge National Laboratory was tasked with analyzing two UF6 filled hoke tubes for uranium isotopic composition. This report documents the results of the measurements performed by the MSIS group’s International Organization for Standardization/International Electrotechnical Commission 17025:2017 accredited operating procedure CSD-AM-CIMS-IN20, Determination of Uranium and Plutonium Isotopic Composition using Thermal Ionization Mass Spectrometry, and in accordance with the quality assurance plan as described in QAP-X-96-CSD/RML-001, Nuclear Analytical Chemistry Laboratory Section Quality Assurance Plan.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA

ORNL Report for Hydrolyzed UF 6 Samples 439451, 438792, 439144, 439616, and 439617

Under the auspices of the US Department of Energy/National Nuclear Security Agency’s Nuclear Reference Material Program (NRMP), the Material Signatures and Isotopic Standards (MSIS) group of Oak Ridge National Laboratory was tasked with analyzing five UF 6 filled P-10 tubes for uranium isotopic composition. This report documents the results of the measurements performed by the MSIS group’s International Organization for Standardization/International Electrotechnical Commission 17025:2017 accredited operating procedure CSD-AM-CIMS-IN20, Determination of Uranium and Plutonium Isotopic Composition using Thermal Ionization Mass Spectrometry, and in accordance with the quality assurance plan as described in QAP-X-96-CSD/RML-001, Nuclear Analytical Chemistry Laboratory Section Quality Assurance Plan.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA