Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CHUGGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Direct contact condensation experiments for clarification of S/C temperature evolution during long term steam discharge

Severe accident codes study the thermo-hydraulics of the suppression chamber with a limited numbers of nodes, generally solving mass and energy equations and assuming perfect mixing conditions. In a long station black out the effect of the quencher's design might create local phenomena (e.g. stratification, hot-spots) which are hardly predicted by the current practices, resulting in mispredictions of the containment pressure evolution. In order to understand the effect of the quencher geometry, steam mass flux, water sub-cooling and air concentration the SWAM facility (Steam Water Air Mixing) at the SIET laboratory was employed performing around twenty different experiments, in conditions close to what is expected during the Fukushima Daiichi accident. The test facility (pool and pipes) is built with polycarbonate (transparent material) to ease the acquisition of the conventional and high-speed cameras. Vertically distributed thermocouples and high-frequency pressure measurements are employed to obtain quantitative values for phenomena investigation and future CFD validations. It was shown that experiments with pure steam and relatively large diameter holes induce chugging that enhances mixing in the pool. Once chugging ceases, because of the reduced sub-cooling, a hot water layer is created in the upper part of the pool. The presence of air in the pipe induces large stratification from the condition of large subcooling because of the limited mixing introduced in the region below the pipe mouth. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

CFD Simulations of a Regenerative Process for Carbon Dioxide Capture in Advanced Gasification Based Power Systems

This project describes the work carried out to prepare a highly reactive and mechanically strong MgO based sorbents and to develop a Population Balance Equations (PBE) approach to describe the evolution of the particle porosity distribution that is linked with Computational Fluid Dynamics (CFD) to perform simulations of the CO2 capture and sorbent regeneration. A large number of MgO-based regenerable sorbents were prepared using low cost and abundant dolomite as the base material. Among various preparation parameters investigated the potassium/magnesium (K/Mg) ratio was identified as the key variable affecting the reactivity and CO2 capacity of the sorbent. The optimum K/Mg ratio is about 0.15. The sorbent formulation HD52-P2 was identified as the “best” sorbent formulation and a large batch (one kg) of the sorbent was prepared for the detailed study. The results of parametric study indicate the optimum carbonation and regeneration temperatures are 360° and 500°C, respectively. The results also indicate that steam has a beneficial effect on the rate of carbonation and regeneration of the sorbent and that the reactivity and capacity of the sorbent decreases in the cycling process (sorbent deactivation). The results indicate that to achieve a high CO2 removal efficiency, the bed of sorbent should be operated at a temperature range of 370-410°C which also favors production of hydrogen through the WGS reaction. To describe the carbonation reaction kinetics of the MgO, the Variable Diffusivity shrinking core Model (VDM) was developed in this project, which was shown to accurately fit the experimental data. An important advantage of this model is that the changes in the sorbent conversion with time can be expressed in an explicit manner, which will significantly reduce the CFD computation time. A Computational Fluid Dynamic/Population Balance Equations (CFD/PBE) model was developed that accounts for the particle (sorbent) porosity distribution and a new version of the method of moments, called Finite size domain Complete set of trial functions Method Of Moments (FCMOM) was used to solve the population balance equations. The PBE model was implemented in a commercial CFD code, Ansys Fluent 13.0. The code was used to test the model in some simple cases and the results were verified against available analytical solution in the literature. Furthermore, the code was used to simulate CO2 capture in a packed-bed and the results were in excellent agreement with the experimental data obtained in the packed bed. The National Energy Laboratory (NETL) Carbon Capture Unit (C2U) design was used in simulate of the hydrodynamics of the cold flow gas/solid system (Clark et al.58). The results indicate that the pressure drop predicted by the model is in good agreement with the experimental data. Furthermore, the model was shown to be able to predict chugging behavior, which was observed during the experiment. The model was used as a base-case for simulations of reactive flow at elevated pressure and temperatures. The results indicate that by controlling the solid circulation rate, up to 70% CO2 removal can be achieved and that the solid hold up in the riser is one of the main factors controlling the extent of CO2 removal. The CFD/PBE simulation model indicates that by using a simulated syngas with a composition of 20% CO2, 20% H2O, 30% CO, and 30% H2, the composition (wet basis) in the reactor outlet corresponded to about 60% CO2 capture with and exit gas containing 65% H2. A preliminary base-case-design was developed for a regenerative MgO-based pre-combustion carbon capture process for a 500 MW IGCC power plant. To minimize the external energy requirement, an extensive heat integration network was developed in Aspen/HYSYS® to produce the steam required in the regenerator and heat integration. In this process, liquid CO2 produced at 50 atm can easily be pumped and sequestered or stored. The preliminary economic analyses indicate that the estimated cost of carbon v capture is in the range of $31-$44/ton, suggesting that a regenerative MgO-Based process can be a viable option for pre-combustion carbon dioxide capture in advanced gasification based power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Time Analysis on a Steam Condensation Jet

The time dependence of a steam bubble entering a water pool was measured for this experiment. The temperature of the water tank at the nozzle exit was 75 deg. C ± 5 deg. C. The experiment will focus on how the bubble changes its size through time for future experimental analysis concerning the heat transfer coefficient. The study focuses at different steam flow velocities approaching the water tank. The area of the steam bubble was measured using a high-speed camera to obtain the heat transfer coefficients. The region of interest is illuminated with a laser or a halogen lamp depending on the experiment. Calculating the rate at which the bubbles are created and condensed, will help obtain a better understanding of the energy transfer between the bubble and the water. The study of steam condensation is important due to its application on nuclear plants, heat exchangers, geothermal power plants and steam ejectors. Recently, more experiments have been performed and studied due to its high heat transfer rate. The results obtained in this experiment will be used to validate CFD models. This primary experimental report focuses on the steam bubble's time dependence; the same system will be used for future experiments concerning the heat transfer coefficient. In previous work done by Chun using only steam, the average heat transfer coefficient of direct contact condensation reported was in the range of 1.0-3.5 MW/m{sup 2} deg. C. He proposes an empirical correlation to predict the average heat transfer coefficients. The experimental data agrees with the empirical correlation within ± 30%. On a different experiment performed by Gulawani using a hot film anemometer on a steam condensation jet. The reported heat transfer coefficient for the vapor liquid interface varies between 0.1-4 MW/m{sup 2}-K. The nozzle diameter used during this experiment varied between 1-2 mm, and the velocity ranged between 286-304 m/s. Aya and Nariai reported three different heat transfer coefficients for direct contact condensation. They reported a heat transfer coefficient at chugging of 2*10{sup 6} W/m{sup 2}-K, at condensation oscillation of 10{sup 5} - 10{sup 6} W/m{sup 2}-K, and at the surface of stratified flow of 3*10{sup 3} - 3*10{sup 4} W/m{sup 2}-K. With steam and air mixture, a heat transfer coefficient relating the bubble average area was reported by Qu. He reported that the heat transfer coefficient decreased with the increase of the bubble diameter. The relation is time dependant and can be used to the transient analysis of the heat transfer. For this experiment, a set of images was obtained of a steam jet. The pictures were analyzed to obtained the time dependence of the steam bubble with time, and the rate of its condensation. A frequency of 20 Hz was calculated when the steam had a flow rate of 2.5 grams per second. The first result obtained for this experiment. In the future, more flow rates will be analyzed to obtain a relationship between the frequency of the bubbles and the flow rate of the steam. Eventually, this information will aid with the calculation of the heat transfer coefficient of the steam jet in a water pool.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Computation of Air Discharge into a Water Pool by Using Volume-of-Fluid Method

Suppression tanks, in-containment refueling water storage tanks (IRWSTs) and filtered containment venting systems (FCVSs) of nuclear power plants use water pools to accommodate high-pressure and high-temperature discharge of non-condensable gases and/or steam. Dynamic behavior of gas bubbles inside a water pool determines pressure and temperature loading to the system and thus we need validated method for applications. The underlying physics relevant to these problems is still a difficult issue due to the complicated nature of gas- liquid interfacial transfers of mass, momentum, and energy in a two-phase flow. Therefore, notwithstanding many studies performed over the past two or three decades, two-fluid theory is still a formidable task and direct numerical simulation (DNS) needs huge computing cost. Pellegrini et al. analyzed steam condensation and chugging in the water pool of the PPOOLEX STB-24 test by using STAR-CCM+ code implemented with two-phase interface model based on the Rayleigh-Taylor instability theory (RTI) which triggers steam depressurization. For the solution of the fine interface, they used Eulerian-Eulerian model for the fluid domain since the volume-of-fluid (VOF) model requires larger mesh points. The RTI resulted in complete steam condensation consistent with the experiment. The fluid tank was open to the atmosphere. They reported the volume fraction distributions in the pool, not the pool temperature or pressure history. For non-condensing gas discharges, however, the VOF is still a good alternative to the Eulerian two-fluid or the DNS approaches. The spatial distribution of each phase is defined in terms of volume fractions and the cell physical properties are obtained from linear combinations of those of constituent phases weighted by each volume fraction. Therefore, conditions where thermal and phase change effects become important are less likely to be simulated realistically. The VOF model is suited for the simulation of flows where each phase constitutes a large structure with a relatively small total contact area between phases. Present work is also interested in this VOF method for application to air discharge into a water pool which occurs in the early operating stages of the said facilities. Our purpose is to validate the VOF method against an existing air discharge experiment of PPOOLEX by using a commercial CFD code, STAR-CCM+ version 10.04, in terms of macroscopic flow properties. Effect of turbulence is also discussed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Amazon and La Plata River Basins as Moisture Sources of South America: Climatology and Intraseasonal Variability

Abstract Land‐atmosphere interactions are critical for precipitation (PPT) over South America where terrestrial evapotranspiration (ET) constitutes a significant fraction of moisture for rainfall over the ecologically and socio‐economically vital Amazon (AMZ) and La Plata (LPB) river basins. We quantify the contribution of ET from AMZ and LPB to PPT over the continent with a focus on the intraseasonal time scale. Using numerical water tracers embedded in the Weather Research and Forecasting model we track the moisture originating from the two basins. Our findings indicate that approximately 40% of annual rainfall over the eastern foothills of the Andes originates as AMZ ET, and nearly 30% of rainfall over northern Argentina originates as LPB ET. Analysis of moisture transport during both phases of the dominant intraseasonal oscillation pattern over South America reveals an intraseasonal “sloshing” of LPB moisture between the South Atlantic convergence zone (SACZ) and southeastern South America (SESA) regions. AMZ and LPB each supply approximately 6% of moisture for SACZ PPT during periods of intraseasonal enhancement (positive anomalies), highlighting the importance of moisture from the Atlantic Ocean. For the SESA region, LPB supplies 26% of the moisture for PPT during periods of intraseasonal enhancement while AMZ supplies 5%.

54 ENVIRONMENTAL SCIENCES↗

hLARP7 C-terminal domain contains an xRRM that binds the 3' hairpin of 7SK RNA

The 7SK small nuclear ribonucleoprotein (snRNP) sequesters and inactivates the positive transcription elongation factor b (P-TEFb), an essential eukaryotic mRNA transcription factor. The human La-related protein group 7 (hLARP7) is a constitutive component of the 7SK snRNP and localizes to the 3' terminus of the 7SK long noncoding RNA. hLARP7, and in particular its C-terminal domain (CTD), is essential for 7SK RNA stability and assembly with P-TEFb. The hLARP7 N-terminal Lamodule binds and protects the 3' end from degradation, but the structural and functional role of its CTD is unclear.We report the solution NMR structure of the hLARP7 CTD and show that this domain contains an xRRM, a class of atypical RRM first identified in the Tetrahymena thermophila telomerase LARP7 protein p65. The xRRM binds the 3' end of 7SK RNA at the top of stem-loop 4 (SL4) and interacts with both unpaired and base-paired nucleotides. This study thus confirms that the xRRM is general to the LARP7 family of proteins and defines the binding site for hLARP7 on the 7SK RNA, providing insight into function.

59 BASIC BIOLOGICAL SCIENCES↗

Advancing South American Water and Climate Science Through Multi-Decadal Convection-Permitting Modeling

The South America Affinity Group (SAAG) was established in early 2019 by the National Center for Atmospheric Research (NCAR) Water Systems Program as a community effort focused on improving hydroclimate science over South America. SAAG supports large research efforts such as the ANDEX Regional Hydroclimate Program as well as individual research groups. The group started with a dozen members and quickly grew to over 100 participants from more than ten countries. For the past four years, the SAAG has been meeting online every two weeks and has organized sessions at international conferences such as the American Geophysical Union Fall Meeting and the Convection-Permitting Climate Workshop. At the core of the SAAG effort are two multi-decadal convection permitting (CP) model simulations with 4-km grid spacing for historical and future climates over the South American continent. Additionally, a major observational data collection effort has been undertaken, including in-situ station data from South American meteorological and water services, gridded products, satellite-based observations, and field campaign data. In conclusion, this article discusses the research needs and scientific goals that drive this community of scientists with diverse backgrounds and interests.

54 ENVIRONMENTAL SCIENCES↗