Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CHEMCAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

ChemCam on MSL 2009: first laser induced breakdown spectrometer for space science

ChemCam is one of the 10 instrument suites on the Mars Science Laboratory, a martian rover being built by Jet Propulsion Laboratory, for the next NASA mission to Mars (MSL 2009). ChemCam is an instrument package consisting of two remote sensing instruments: a Laser-Induced Breakdown Spectrometer (LIBS) and a Remote Micro-Imager (RMI). LIBS provides elemental compositions of rocks and soils, while the RMI places the LIBS analyses in their geomorphologic context. Both instruments rely on an autofocus capability to precisely focus on the chosen target, located at distances from the rover comprised between 1 and 9 m for LIBS, and 2 m and infinity for RMI. ChemCam will help determine which samples, within the vicinity of the MSL rover, are of sufficient interest to use the contact and in-situ instruments for further characterization. It will provide valuable analyses of samples that are inaccessible to contact and in-situ instruments, and of a much larger number of samples than can be done with this kind of instrument. ChemCam also has a capability to provide passive spectroscopy data of rocks and soils on Mars. ChemCam hardware consists of a Mast Unit (MU), provided by France, and a Body Unit (BU) built and tested in the USA. The Flight Model of the MU is assembled, tested and now available in the USA, while the BU is currently being assembled and tested. Both will be connected by the end of year '08 for end-to-end functional and performance tests, before delivery to JPL and assembly on the MSL rover. Launch is scheduled for October 09. After describing the concept of ChemCam, this presentation focuses on its French part, Mast Unit. The results presented show that Mast Unit is able to generate a plasma and collect its light, over the full applicable ranges of distances and temperatures on Mars.

47 OTHER INSTRUMENTATION↗

Characterization of LIBS emission lines for the identification of chlorides, carbonates, and sulfates in salt/basalt mixtures for the application to MSL ChemCam data: LIBS OF CL, C, S IN SALT-BASALT MIXTURES

Ancient environmental conditions on Mars can be probed through the identification of minerals on its surface, including water-deposited salts and cements dispersed in the pore space of sedimentary rocks. Laser-induced breakdown spectroscopy (LIBS) analyses by the Martian rover Curiosity's ChemCam instrument can indicate salts, and ChemCam surveys aid in identifying and selecting sites for further, detailed in situ analyses. Here, we performed laboratory LIBS experiments under simulated Mars conditions with a ChemCam-like instrument on a series of mixtures containing increasing concentrations of salt in a basaltic background to investigate the potential for identifying and quantifying chloride, carbonate, and sulfate salts found only in small amounts, dispersed in bulk rock with ChemCam, rather than concentrated in veins. The data then indicate that the presence of emission lines from the basalt matrix limited the number of Cl, C, and S emission lines found to be useful for quantitative analysis; nevertheless, several lines with intensities sensitive to salt concentration were identified. Detection limits for the elements based on individual emission lines ranged from ~20 wt % carbonate (2 wt % C), ~5–30 wt % sulfate (1–8 wt % S), and ~5–10 wt % chloride (3–6 wt % Cl) depending on the basaltic matrix and/or salt cation. Absolute quantification of Cl, C, and S in the samples via univariate analysis depends on the cation-anion pairing in the salt but appears relatively independent of matrices tested, following normalization. Our results are promising for tracking relative changes in the salt content of bulk rock on the Martian surface with ChemCam.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Retrieval of water vapor column abundance and aerosol properties from ChemCam passive sky spectroscopy

In this work, we derive water vapor column abundances and aerosol properties from Mars Science Laboratory (MSL) ChemCam passive mode observations of scattered sky light. This paper covers the methodology and initial results for water vapor and also provides preliminary results for aerosols. The data set presented here includes the results of 113 observations spanning from Mars Year 31 L s = 291° (March 30, 2013) to Mars Year 33 L s = 127° (March 24, 2016). Each ChemCam passive sky observation acquires spectra at two different elevation angles. We fit these spectra with a discrete-ordinates multiple scattering radiative transfer model, using the correlated-k approximation for gas absorption bands. The retrieval proceeds by first fitting the continuum of the ratio of the two elevation angles to solve for aerosol properties, and then fitting the continuum-removed ratio to solve for gas abundances. The final step of the retrieval makes use of the observed CO 2 absorptions and the known CO 2 abundance to correct the retrieved water vapor abundance for the effects of the vertical distribution of scattering aerosols and to derive an aerosol scale height parameter. Our water vapor results give water vapor column abundance with a precision of ±0.6 precipitable microns and systematic errors no larger than ±0.3 precipitable microns, assuming uniform vertical mixing. The ChemCam-retrieved water abundances show, with only a few exceptions, the same seasonal behavior and the same timing of seasonal minima and maxima as the TES, CRISM, and REMS-H data sets that we compare them to. However ChemCam-retrieved water abundances are generally lower than zonal and regional scale from-orbit water vapor data, while at the same time being significantly larger than pre-dawn REMS-H abundances. Pending further analysis of REMS-H volume mixing ratio uncertainties, the differences between ChemCam and REMS-H pre-dawn mixing ratios appear to be much too large to be explained by large scale circulations and thus they tend to support the hypothesis of substantial diurnal interactions of water vapor with the surface. Our preliminary aerosol results, meanwhile, show the expected seasonal pattern in dust particle size but also indicate a surprising interannual increase in water–ice cloud opacities.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration of the Fluorine, Chlorine and Hydrogen Content of Apatites With the ChemCam LIBS Instrument

Determining the composition of apatites is important to understand the behavior of volatiles during planetary differentiation. Apatite is an ubiquitous magmatic mineral in the SNC meteorites. It is a significant reservoir of halogens in these meteorites and has been used to estimate the halogen budget of Mars. Apatites have been identified in sandstones and pebbles at Gale crater by ChemCam, a Laser-Induced Breakdown Spectroscometer (LIBS) instrument onboard the Curiosity rover. Their presence was inferred from correlations between calcium, fluorine (using the CaF molecular band centered near 603 nm, whose detection limit is much lower that atomic or ionic lines and, in some cases, phosphorus (whose detection limit is much larger). An initial quantification of fluorine, based on fluorite (CaF2)/basalt mixtures and obtained at the LANL laboratory, indicated that the excess of F/Ca (compared to the stoichiometry of pure fluorapatites) found on Mars in some cases could be explained by the presence of fluorite. Chlorine was not detected in these targets, at least above a detection limit of 0.6 wt% estimated from. Fluorapatite was later also detected by X-ray diffraction (with CheMin) at a level of approx.1wt% in the Windjana drill sample (Kimberley area), and several points analyzed by ChemCam in this area also revealed a correlation between Ca and F. The in situ detection of F-rich, Cl-poor apatites contrasts with the Cl-rich, F-poor compositions of apatites found in basaltic shergottites and in gabbroic clasts from the martian meteorite NWA 7034, which were also found to be more Cl-rich than apatites from basalts on Earth, the Moon, or Vesta. The in situ observations could call into question one of the few possible explanations brought forward to explain the SNC results, namely that Mars may be highly depleted in fluorine. The purpose of the present study is to refine the calibration of the F, Cl, OH and P signals measured by the ChemCam LIBS instrument, initiated for F, for Cl in soils, for P, and estimate their limit of detection. For this purpose, different types of apatites and mixtures of basalt powder and apatites were analyzed using ChemCam Engineering Qualification Model (EQM) at IRAP, Toulouse. The present abstract presents the initial results from the laboratory analyses. Differences between the response function of the EQM and the Flight Model of ChemCam are still to be refined to apply these new results to the Martian dataset.

Meslin, P.-Y.↗

Retrieval of Water Vapor Column Abundance and Aerosol Properties from ChemCam Passive Sky Spectroscopy

We derive water vapor column abundances and aerosol properties from Mars Science Laboratory (MSL) ChemCam passive mode observations of scattered sky light. This paper covers the methodology and initial results for water vapor and also provides preliminary results for aerosols. The data set presented here includes the results of 113 observations spanning from Mars Year 31 L(s) = 291 deg (March 30, 2013) to Mars Year 33 L(s) = 127 deg (March 24, 2016). Each ChemCam passive sky observation acquires spectra at two different elevation angles. We fit these spectra with a discrete-ordinates multiple scattering radiative transfer model, using the correlated-k approximation for gas absorption bands. The retrieval proceeds by first fitting the continuum of the ratio of the two elevation angles to solve for aerosol properties, and then fitting the continuum-removed ratio to solve for gas abundances. The final step of the retrieval makes use of the observed CO 2 absorptions and the known CO 2 abundance to correct the retrieved water vapor abundance for the effects of the vertical distribution of scattering aerosols and to derive an aerosol scale height parameter. Our water vapor results give water vapor column abundance with a precision of +/-0.6 precipitable microns and systematic errors no larger than +/-0.3 precipitable microns, assuming uniform vertical mixing. The ChemCam-retrieved water abundances show, with only a few exceptions, the same seasonal behavior and the same timing of seasonal minima and maxima as the TES, CRISM, and REMS-H data sets that we compare them to. However ChemCam-retrieved water abundances are generally lower than zonal and regional scale from-orbit water vapor data, while at the same time being significantly larger than pre-dawn REMS-H abundances. Pending further analysis of REMS-H volume mixing ratio uncertainties, the differences between ChemCam and REMS-H pre-dawn mixing ratios appear to be much too large to be explained by large scale circulations and thus they tend to support the hypothesis of substantial diurnal interactions of water vapor with the surface. Our preliminary aerosol results, meanwhile, show the expected seasonal pattern in dust particle size but also indicate a surprising interannual increase in water-ice cloud opacities.

Mcconnochie, Timothy H.↗

Alkali trace elements in Gale crater, Mars, with ChemCam: Calibration update and geological implications

The Chemistry Camera (ChemCam) instrument onboard Curiosity can detect minor and trace elements such as lithium, strontium, rubidium, and barium. Their abundances can provide some insights about Mars' magmatic history and sedimentary processes. We focus on developing new quantitative models for these elements by using a new laboratory database (more than 400 samples) that displays diverse compositions that are more relevant for Gale crater than the previous ChemCam database. These models are based on univariate calibration curves. For each element, the best model is selected depending on the results obtained by using the ChemCam calibration targets onboard Curiosity. New quantifications of Li, Sr, Rb, and Ba in Gale samples have been obtained for the first 1000 Martian days. Comparing these data in alkaline and magnesian rocks with the felsic and mafic clasts from the Martian meteorite NWA7533—from approximately the same geologic period—we observe a similar behavior: Sr, Rb, and Ba are more concentrated in soluble- and incompatible-element-rich mineral phases (Si, Al, and alkali-rich). Correlations between these trace elements and potassium in materials analyzed by ChemCam reveal a strong affinity with K-bearing phases such as feldspars, K-phyllosilicates, and potentially micas in igneous and sedimentary rocks. However, lithium is found in comparable abundances in alkali-rich and magnesium-rich Gale rocks. This very soluble element can be associated with both alkali and Mg-Fe phases such as pyroxene and feldspar. Here, these observations of Li, Sr, Rb, and Ba mineralogical associations highlight their substitution with potassium and their incompatibility in magmatic melts.

58 GEOSCIENCES↗

LANL Researcher Roger Wiens Discusses ChemCam

Discussion of the ChemCam instrument on the Curiosity Rover that occurred during the NASA press conference prior to launch of the Mars Science Laboratory. The ChemCam instrument was developed by Los Alamos National Laboratory and the French Space Institute. Los Alamos National Laboratory researcher Roger Wiens discusses the instrument on this video. ChemCam uses a laser to "zap" features of the Martian landscape and then uses a spectrometer to gather information about the composition of the sample. ChemCam will help the Curiosity Rover determine whether Mars is or was habitable. The Rover is expected to touch down on the Red Planet on August 5, 2012.

79 ASTRONOMY AND ASTROPHYSICS↗

Using ChemCam LIBS data to constrain grain size in rocks on Mars: Proof of concept and application to rocks at Yellowknife Bay and Pahrump Hills, Gale crater

Grain size in martian sedimentary rocks can be constrained using point-to-point chemical variabilities in Laser Induced Breakdown Spectroscopy (LIBS) data from the ChemCam instrument on the Mars Science Laboratory (MSL) Curiosity rover. The diameter of each point ablated by the ChemCam laser is in the range of medium to coarse sand in size. Thus, rocks with grains significantly smaller than the laser spot size produce bulk rock compositions at each LIBS point and low point-to-point chemical variability among LIBS points. In contrast, analyses of rocks with grains about the size of the spot or larger contain contributions from individual grains at each point and often have high point-to-point chemical variability. Here the Gini index, a statistical parameter, was used to calculate the point-to-point chemical variability in major-element oxide compositions derived from the ChemCam LIBS data. First, the total range of each LIBS major-element oxide composition was normalized from 0 to 1 across all LIBS observations. Then the Gini index was calculated for each oxide in each LIBS observation. Finally, the Gini indices of each oxide were averaged to derive a Gini index mean score, G MEAN , for each LIBS observation. A correlation between G MEAN and grain size was validated using sedimentary rocks of various grain sizes from the Yellowknife Bay formation and the Pahrump Hills member of the Murray formation in Gale crater. Overall, finer-grained rocks had smaller G MEAN than coarser-grained rocks. To calibrate G MEAN to grain size, grain size estimates based on visual assessment of high-resolution images were compared to G MEAN values for the same targets to create a calibrated scale. This calibrated scale was used to infer the grain size of rocks with unknown grain size. Overall, the grain sizes predicted for rocks with unknown grain size overlapped with those of known grain size from the same units and/or bedrock targets. The grain sizes inferred using the G MEAN based on ChemCam LIBS data are complimentary to those determined from images and both techniques can be used to improve interpretations of the depositional environments of rocks analyzed by Curiosity and future Mars missions with LIBS, such as the Mars 2020 rover.

58 GEOSCIENCES↗

Variability in Mt. Sharp Group Bedrock as Seen By ChemCam Passive and Active Spectra

The Curiosity rover landed in Gale crater in August 2012 and has since been travelling up the central sedimentary mound known as Mt. Sharp. The ChemCam instrument on Curiosity was designed primarily for the use of Laser Induced Breakdown Spectroscopy (LIBS), where a laser ablates a small amount of material from the target and the spectrum of the resulting plasma yields elemental abundance data. ChemCam’s three spectrometers range from 240-905 nm and can also take passive spectra (without the use of the laser). The spectral range ChemCam passive spectra observe is sensitive to charge-transfer and crystal field absorptions related to iron-bearing minerals. In the first 2934 sols of Curiosity’s mission, 9,400 passive spectra were taken of bedrock targets in Mt. Sharp’s Murray and Carolyn Shoemaker formations. We examine these spectra using spectral slope/ratio and band depth calculations as well as Principal Component Analysis (PCA). For the first time, paired passive spectra and LIBS elemental abundances are compared on a large scale. Finally, CheMin data are compared to ChemCam passive observations to understand sources of spectral variability.

H T Manelski↗

Improving ChemCam LIBS long-distance elemental compositions using empirical abundance trends

The ChemCam instrument on the Curiosity rover provides chemical compositions of Martian rocks and soils using remote laser-induced breakdown spectroscopy (LIBS). The elemental calibration is stable as a function of distance for Ti, Fe, Mg, and Ca. The calibration shows small, systematically increasing abundance trends as a function of distance for Al, Na, K, and to some extent, Si. The distance effect is known to be due to a dependence with distance on the relative strengths of atomic transition lines. Emission lines representing transitions from relatively low energy levels remain intense at longer distances while emission lines representing transitions from higher energy levels decrease in intensity more rapidly as a function of distance. The multivariate algorithms used to determine elemental compositions rely on a large number of emission lines in many cases, so rather than trying to correct all emission lines, a study was made of the predicted compositions as a function of distance, in order to determine an empirical correction. Abundance trends can be well approximated by a linear trend with distance within the ranges of abundances and distances observed up to ~6 m. Data from 11 distinct geological members and data groups of the Murray formation in Gale crater, Mars, were used to form the model, selecting the members and data groups yielding the best statistics. The model was tested using data from several targets observed from two different distances, and using data from the Kimberley formation, the composition of which is significantly different from the Murray formation, showing that the model works on other compositions beyond those used to build the model. For long-distance observations up to ~6 m, corrections can be made back to an equivalent composition at the median distance of ChemCam observations (2.6 m). Finally, the model has been validated up to 6.2 m, although ChemCam is able to observe bedrock targets to >7 m, and iron meteorites to distances of >9 m.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ChemCam Rock Laser for the Mars Science Laboratory

Los Alamos has a long history of space-related instruments, tied primarily to its role in defense-related treaty verification. Space-based detectors have helped determine the differences between signals from lightning bolts and potential nuclear explosions. LANL-developed gamma-ray detection instruments first revealed the existence of what we now know as gamma-ray bursts, an exciting area of astrophysical research. And the use of LANL instruments on varied space missions continues with such products as the ChemCam rock laser for NASA, shown here. The Engineering Model of the ChemCam Mars Science Laboratory rover instrument arrived at NASA's Jet Propulsion Laboratory on February 6, 2008. ChemCam will use imaging and laser-induced breakdown spectroscopy (LIBS) to determine rock and soil compositions on Mars, up to 9 meters from the rover. The engineering model is being integrated into the rover test bed for the development and testing of the rover software. The actual flight model components are concurrently being assembled at Los Alamos and in Toulouse, France, and will be delivered to JPL in July. The Mars Science Laboratory is scheduled to launch in 2011. Animations courtesy of JPL/NASA.

47 OTHER INSTRUMENTATION↗

Application of distance correction to ChemCam laser-induced breakdown spectroscopy measurements

Laser-induced breakdown spectroscopy (LIBS) provides chemical information from atomic, ionic, and molecular emissions from which geochemical composition can be deciphered. Analysis of LIBS spectra in cases where targets are observed at different distances, as is the case for the ChemCam instrument on the Mars rover Curiosity, which performs analyses at distances between 2 and 7.4 m is not a simple task. Previously, we showed that spectral distance correction based on a proxy spectroscopic standard created from first-shot dust observations on Mars targets ameliorates the distance bias in multivariate-based elemental-composition predictions of laboratory data. In this work, we correct an expanded set of neutral and ionic spectral emissions for distance bias in the ChemCam data set. By using and testing different selection criteria to generate multiple proxy standards, we find a correction that minimizes the difference in spectral intensity measured at two different distances and increases spectral reproducibility. When the quantitative performance of distance correction is assessed, there is improvement for SiO 2 , Al 2 O 3 , CaO, FeOT, Na 2 O, K 2 O, that is, for most of the major rock forming elements, and for the total major-element weight percent predicted. But, for MgO the method does not provide improvements while for TiO 2 , it yields inconsistent results. Additionally, we observed that many emission lines do not behave consistently with distance, evidenced from laboratory analogue measurements and ChemCam data. This limits the effectiveness of the method.

36 MATERIALS SCIENCE↗

Characterization of Hydrogen in Basaltic Materials With Laser-Induced Breakdown Spectroscopy (LIBS) for Application to MSL ChemCam Data

Here, the Mars Science Laboratory rover, Curiosity , is equipped with ChemCam, a laser–induced breakdown spectroscopy (LIBS) instrument, to determine the elemental composition of nearby targets quickly and remotely. We use a laboratory sample set including prepared mixtures of basalt with systematic variation in hydrated mineral content and compositionally well–characterized, altered basaltic volcanic rocks to measure hydrogen by characterizing the H–alpha emission line in LIBS spectra under Martian environmental conditions. The H contents of all samples were independently measured using thermogravimetric analysis. We found that H peak area increases with weight percent H for our laboratory mixtures with basaltic matrices. The increase is linear with weight percent H in the mixtures with structurally bound H up to about 1.25 wt.% H and then steepens for higher H–content samples, a nonlinear trend not previously reported but potentially important for characterizing high water content materials. To compensate for instrument, environmental, and target matrix–related effects on quantification of H content from the LIBS signal, we examined multiple normalization methods. The best performing methods utilize O 778– and C 248–nm emission lines. The methods return comparable results when applied to ChemCam data of H–bearing materials on Mars. The calibration and normalization methods tested here will aid in investigations of H by LIBS on Mars with ChemCam and SuperCam. Further laboratory work will aid quantification across different physical matrices and heterogeneous textures because of differences we observed in H in pelletized and natural rock samples of the same composition.

58 GEOSCIENCES↗

Constraints on iron sulfate and iron oxide mineralogy from ChemCam visible/near-infrared reflectance spectroscopy of Mt. Sharp basal units, Gale Crater, Mars

Relative reflectace point spectra (400–840 nm) were acquired by the Chemistry and Camera (ChemCam) instrument on the Mars Science Laboratory (MSL) rover Curiosity in passive mode (no laser) of drill tailings and broken rock fragments near the rover as it entered the lower reaches of Mt. Sharp and of landforms at distances of 2–8 km. Freshly disturbed surfaces are less subject to the spectral masking effects of dust, and revealed spectral features consistent with the presence of iron oxides and ferric sulfates. Here, we present the first detection on Mars of a ~433 nm absorption band consistent with small abundances of ferric sulfates, corroborated by jarosite detections by the Chemistry and Mineralogy (CheMin) X-ray diffraction instrument in the Mojave, Telegraph Peak, and Confidence Hills drilled samples. The disturbed materials near the Bonanza King region also exhibited strong 433 nm bands and negative near-infrared spectral slopes consistent with jarosite. ChemCam passive spectra of the Confidence Hills and Mojave drill tailings showed features suggestive of the crystalline hematite identified by CheMin analyses. The Windjana drill sample tailings exhibited flat, low relative reflectance spectra, explained by the occurrence of magnetite detected by CheMin. Passive spectra of Bonanza King were similar, suggesting the presence of spectrally dark and neutral minerals such as magnetite. Long-distance spectra of the “Hematite Ridge” feature (3–5 km from the rover) exhibited features consistent with crystalline hematite. The Bagnold dune field north of the Hematite Ridge area exhibited low relative reflectance and near-infrared features indicative of basaltic materials (olivine, pyroxene). Light-toned layers south of Hematite Ridge lacked distinct spectral features in the 400–840 nm region, and may represent portions of nearby clay minerals and sulfates mapped with orbital near-infrared observations. The presence of ferric sulfates such as jarosite in the drill tailings suggests a relatively acidic environment, likely associated with flow of iron-bearing fluids, associated oxidation, and/or hydrothermal leaching of sedimentary rocks. Combined with other remote sensing data sets, mineralogical constraints from ChemCam passive spectra will continue to play an important role in interpreting the mineralogy and composition of materials encountered as Curiosity traverses further south within the basal layers of the Mt. Sharp complex.

58 GEOSCIENCES↗

Neural Density Estimation and Uncertainty Quantification for ChemCam Spectra [Slides]

The ChemCam instrument of Curiosity uses laser-induced breakdown spectroscopy (LIBS). It fires a laser at target and vaporizes rock surfaces, creating a plasma. Three spectrographs divide the plasma light into wavelengths for chemical analysis: ultraviolet, violet, and visible near-infrared. Regression methods (SVR, PCR, CNN) have been employed for calibration (prediction of the elemental composition of samples); however, labeled ChemCam samples are limited. Here, we focus on unsupervised learning and employ generative models from ChemCam analysis. Further, we use labels (supervised) in combination to the generative model to compute uncertainties related to predictions. We report generative modeling can be successfully applied to model real-world data. Normalizing flow models can be efficiently constructed on latent spaces for fast downstream inference. Unsupervised and supervised learning can be combined to form an uncertainty quantification framework.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ChemCam Science Objectives for the Mars Science Laboratory (MSL) Rover

ChemCam consists of two remote sensing instruments. One, a Laser-Induced Breakdown Spectroscopy (LIBS) instrument provides rapid elemental composition data on rocks and soils within 13 m of the rover. By using laser pulses, it can remove dust or profile through weathering layers remotely. The other instrument, the Remote Micro-Imager (RMI), provides the highest resolution images between 2 m and infinity. At approximately 80 Rad field of view, its resolution exceeds that of MER Pancam by at least a factor of four. The ChemCam instruments are described in a companion paper by Maurice et al. Here we present the science objectives for the ChemCam instrument package.

Wiens, R.↗

ChemCam Science Objectives for the Mars Science Laboratory (MSL) Rover

ChemCam consists of two remote sensing instruments. One, a Laser-Induced Breakdown Spectroscopy (LIBS) instrument provides rapid elemental composition data on rocks and soils within 13 m of the rover. By using laser pulses, it can remove dust or profile through weathering layers remotely. The other instrument, the Remote Micro-Imager (RMI), provides the highest resolution images between 2 m and infinity. At approximately 80 Rad field of view, its resolution exceeds that of MER Pancam by at least a factor of four. The ChemCam instruments are described in a companion paper by Maurice et al. [1]. Here we present the science objectives for the ChemCam instrument package.

Wiens, R.↗

ChemCam rock laser for Mars Science Laboratory "Curiosity"

Los Alamos has a long history of space-related instruments, tied primarily to its role in defense-related treaty verification. Space-based detectors have helped determine the differences between signals from lightning bolts and potential nuclear explosions. LANL-developed gamma-ray detection instruments first revealed the existence of what we now know as gamma-ray bursts, an exciting area of astrophysical research. And the use of LANL instruments on varied space missions continues with such products as the ChemCam rock laser for NASA, shown here. The Engineering Model of the ChemCam Mars Science Laboratory rover instrument arrived at NASA's Jet Propulsion Laboratory on February 6, 2008. The Flight Model was shipped in August, 2010 for installation on the rover at JPL. ChemCam will use imaging and laser-induced breakdown spectroscopy (LIBS) to determine rock and soil compositions on Mars, up to 9 meters from the rover. The engineering model is being integrated into the rover test bed for the development and testing of the rover software. The actual flight model components were concurrently assembled at Los Alamos and in Toulouse, France. The Mars Science Laboratory is scheduled to launch in 2011. Animations courtesy of JPL/NASA.

79 ASTRONOMY AND ASTROPHYSICS↗