At least 19 records

Engineering and design properties of thallium-doped sodium iodide and selected properties of sodium-doped cesium iodide

Mechanical and thermal properties, not available in the literature but necessary to structural design, using thallium doped sodium iodide and sodium doped cesium iodide were determined to be coefficient of linear thermal expansion, thermal conductivity, thermal shock resistance, heat capacity, elastic constants, ultimate strengths, creep, hardness, susceptibility to subcritical crack growth, and ingot variation of strength. These properties were measured for single and polycrystalline materials at room temperature.

Forrest, K.↗

Physical property measurements of doped cesium iodide crystals

Mechanical and thermal property values are reported for crystalline cesium iodide doped with sodium and thallium. Young's modulus, bulk modulus, shear modulus, and Poisson's ratio were obtained from ultrasonic measurements. Young's modulus and the samples' elastic and plastic behavior were also measured under tension and compression. Thermal expansion and thermal conductivity were the temperature dependent measurements that were made.

Synder, R. S.↗

Optical transmission measurements on monocrystalline and polycrystalline cesium iodide

A summary is presented of optical measurements performed on a variety of cesium iodide samples to characterize quantitatively the optical quality of the materials, and to define and measure parameters which determine its suitability as a detector material for high energy cosmic ray experiments on HEAO-A. The general case of light transmission through a long rectangular slab under multiple internal reflections is discussed along with transmission and scattering as a function of wavelength at normal incidence. Scattering parameters are tabulated for encapsulated single crystal CsI and polyscin.

Viehmann, W.↗

Scintillator handbook with emphasis on cesium iodide

This report provides a background of reasonable depth and reference material on scintillators in general. Particular attention is paid to the cesium iodide scintillators as used in the High Energy Astronomy Observatory (HEAO) experiments. It is intended especially for use by persons such as laboratory test personnel who need to obtain a working knowledge of these materials and their characteristics in a short time.

Tidd, J. L.↗

Characteristics of cesium iodide for use as a particle discriminator for high energy cosmic rays

The possible use of CsI to discriminate between high energy cosmic ray electrons and interacting protons has been investigated. The pulse-shape properties as a function of ionization density, temperature, and spectral response are presented for thallium-activated CsI and as a function of ionization density for sodium-activated CsI. The results are based on previously published data and on corroborative measurements from the present work. Experimental results on the response of CsI to electron-induced electromagnetic cascades and to interacting hadrons are described. Bibliographies of publications dealing with the properties of CsI and with pulse-shape discrimination techniques are presented.

Crannell, C. J.↗

The specific light output of cesium iodide crystals

Large area ion chambers for a high energy cosmic ray experiment, scintillating plastic fibers as light pipes for a cosmic ray hodoscope, and an evaluation of clad scintillating light pipes were considered.

Gregory, J. C.↗

Study of the polarization dependence of the photoelectric effect in the soft X-ray band - A focal plane photoelectric stellar X-ray polarimeter for the Spectrum-X-Gamma mission

An experimental study of the polarization dependence of the photoelectric effect in cesium iodide in the soft X-ray band was started (Heckler et al., 1989). At a grazing angle of 10 degrees and a photon energy of 2.6 keV, it is found that the photoelectric yield from a thin layer of evaporated cesium iodide varies by 12.4 percent as the polarization vector of the incident X-ray beam is rotated about the line-of-sight. The rotation angle corresponding to the maximum photoyield is displaced by 16 degrees from the normal to the photocathode. This modulation and phase shift are in good agreement with the results recently reported by Fraser, et al. (1989) It is shown that a focal plane stellar X-ray polarimeter based on this photoelectric effect will be substantially more efficient than convential X-ray polarimeters such as those based on either Bragg reflection or scattering from low atomic number targets.

Heckler, A.↗

Fermi Gamma-ray Space Telescope

The Fermi Gamma-ray Space Telescope, a key mission in multiwavelength and multimessenger studies, has been surveying the γ-ray sky from its low-Earth orbit since 2008. Its two scientific instruments, the Gamma-ray Burst Monitor (GBM) and the Large Area Telescope (LAT), cover 8 orders of magnitude in photon energy. The GBM consists of 12 Sodium Iodide detectors and 2 Bismuth Germinate detectors, covering the 10 keV - 40 MeV energy range, arrayed on two sides of the spacecraft so as to view the entire sky that is not occulted by the Earth. The LAT is a pair production telescope based on silicon strip trackers, a Cesium Iodide calorimeter, and a plastic scintillator anticoincidence system. It covers the energy range from about 20 MeV to more than 500 GeV, with a field of view of about 2.4 steradians. Thanks to their huge fields of view, the instruments can observe the entire sky with a cadence of about an hour for GBM and about three hours for LAT. All γ-ray data from Fermi become public immediately, enabling a broad range of multiwavelength and multimessenger research. Over 3000 γ-ray bursts (GRBs), including GRB 170817A associated with a neutron star merger detected in gravitational waves, and 5000 high-energy sources, including the blazar TXS 0506+056 associated with high-energy neutrinos, have been detected by the Fermi instruments. The Fermi Science Support Center provides a wide array of resources to enable scientific use of the data, including background models, source catalogs, analysis software, documentation, and a Help Desk.

gamma rays↗

Development and testing of the infrared interferometer spectrometer for the Mariner Mars 1971 spacecraft

The design, development and testing of the infrared interferometer spectrometer is reported with emphasis on the unique features of the Mariner instrument as compared to previous IRIS instruments flown on the Nimbus meteorological research satellites. The interferometer functions in the spectral range from 50 microns to 6.3 microns. A noise equivalent radiance of 0.5 X 10 to the -7th power W/sq cm/ster/cm has been achieved. Major improvements that were implemented included the cesium iodide beamsplitter and electronic features to suppress the effect of vibration on the Michelson mirror motion and digital filtering through the summation of increased sampling of the infrared signal. A bit error detection and correction scheme was also implemented in order to recover the science data with a higher level of confidence over the telecommunication link.

Hanel, R. H.↗

Mariner 9 Michelson interferometer.

The Michelson interferometer on Mariner 9 measures the thermal emission spectrum of Mars between 200 and 2000 per cm (between 5 and 50 microns) with a spectral resolution of 2.4 per cm in the apodized mode. A noise equivalent radiance of 0.5 x 10 to the minus 7th W/sq cm/ster/cm is deduced from data recorded in orbit around Mars. The Mariner interferometer deviates in design from the Nimbus 3 and 4 interferometers in several areas, notably, by a cesium iodide beam splitter and certain aspects of the digital information processing. Special attention has been given to the problem of external vibration. The instrument performance is demonstrated by calibration data and samples of Mars spectra.

Hanel, R.↗

Optical effect of the contamination of infrared windows by the outgassing of materials in outer space

The composition and evaporation rate of the outgassing of a space vehicle thermal control paint as a function of temperature were studied. A contamination chamber was designed, constructed, and tested. Samples of thermal control paint were tested to determine if heating to moderate temperatures causes them to release outgassing products which can be collected on a cooled cesium iodide window for identification by IR analysis. Results showed that outgassing of surfaces other than the sample was a problem. Spectral bands of the deposits collected were compared.

Silberman, E.↗

Moisture resistant and anti-reflection optical coatings produced by plasma polymerization of organic compounds

The need for protective coatings on critical optical surfaces, such as halide crystal windows or lenses used in spectroscopy, has long been recognized. It has been demonstrated that thin, one micron, organic coatings produced by polymerization of flourinated monomers in low temperature gas discharge (plasma) exhibit very high degrees of moisture resistence, e.g., hundreds of hours protection for cesium iodide vs. minutes before degradation sets in for untreated surfaces. The index of refraction of these coatings is intermediate between that of the halide substrate and air, a condition for anti-reflection, another desirable property of optical coatings. Thus, the organic coatings not only offer protection, but improved transmittance as well. The polymer coating is non-absorbing over the range 0.4 to 40 microns with an exception at 8.0 microns, the expected absorption for C-F bonds.

Hollahan, J. R.↗

High resolution spectrograph for the Space Telescope

The high resolution spectrograph (HRS) for ultraviolet astronomy with the Space Telescope will provide a spectral resolution of approximately 120,000 over a nominal wavelength range of 110-320 nm, together with a spatial resolution of about 0.25 arc seconds. The two detectors will consist of 512-element Digicons with cesium telluride and cesium iodide photocathodes, respectively. Photoelectrons in transit between the photocathodes and the diodes within the Digicons can be deflected in two axes with 12-bit resolution. This feature facilitates a design that emphasizes reliability since (once a hermetic seal is opened in orbit), only two moving parts, a grating carrousel and a shutter, are required for regular operation of the HRS. The instrument will be controlled by a computer in the spacecraft. The scientific objectives of the HRS investigation relate to interstellar matter in our own and nearby galaxies, physical processes of stellar mass loss and mass transfer, chemical abundances, bright quasars and Seyfert galaxy nuclei, and solar system phenomena.

Brandt, J. C.↗

A balloon measurement of the isotopic composition of galactic cosmic ray boron, carbon and nitrogen

The isotopic compositions of galactic cosmic ray boron, carbon, and nitrogen were measured at energies near 300 MeV amu, using a balloon-borne instrument at an atmospheric depth of approximately 5 g/sq cm. The calibrations of the detectors comprising the instrument are described. The saturation properties of the cesium iodide scintillators used for measurement of particle energy are studied in the context of analyzing the data for mass. The achieved rms mass resolution varies from approximately 0.3 amu at boron to approximately 0.5 amu at nitrogen, consistent with a theoretical analysis of the contributing factors. Corrected for detector interactions and the effects of the residual atmosphere the results are B-10/B=0.33 (+0.17, -0.11), C-13/C=0.06 (+0.13, -0.11), and N-15/N=0.42 (+0.19, -0.17). A model of galactic propagation and solar modulation is described. Assuming a cosmic ray source composition of solar-like isotopic abundances, the model predicts abundances near Earth consistent with the measurements.

Zumberge, J. F.↗

The HEAO-3 high resolution gamma-ray spectrometer

Features and results produced by the HEAO 3 spacecraft gamma ray spectrometer are outlined. The instrument had high resolution germanium detectors, each 55 mm diam and 45 mm long, surrounded by a cesium iodide anticoincidence shield with four quadrants of well-crystal and a collimayor crystal. The crystals had a total effective area of 70 sq cm at 100 keV and 26.4 sq cm at .511 MeV with a spectral resolution at launch of .23 percent at 1.33 MeV. The spacecraft travels a circular orbit of 500 km altitude with an inclination of 43.6 deg. Solid methane and ammonia cryogenic fluids refrigerated the crystals for 8.5 mos, after which the shield crystals functioned as isotropic detectors for solar flare events and gamma ray bursts until mission termination in May 1981. A total of 37 solar flare type events were observed, with gamma ray events occurring with flares of class X1 or stronger.

Jacobson, A. S.↗