Engineering PapersSearch

SEARCH · Engineering Papers

Results for “CERENKOV RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A test of incoherent Cerenkov radiation for VLF hiss and other magnetospheric emissions

Consideration of incoherent Cerenkov radiation from intense fluxes of electrons in the magnetosphere as a source of VLF hiss and several other emission phenomena. A procedure for calculating the Cerenkov and cyclotron radiation power from a spectrum of electrons in a test volume is outlined, as well as a ray-tracing routine for determining the path that the emitted power follows through the magnetosphere. Comparisons are made between a VLF hiss event and an energetic particle spectrum observed simultaneously with the Injun 5 spacecraft. Calculated power and fields for incoherent Cerenkov radiation are two orders of magnitude below the observed VLf hiss values, although the spectral shapes are similar. It is concluded that a partially coherent or amplified Cerenkov source or an instability is located in the altitude range from 3000 to 10,000 km. Calculations regarding Cerenkov radiation as a possible source for other wave phenomena indicate that upper hybrid resonance noise and fast hisslers may be understood in terms of incoherent Cerenkov radiation, but that V-shaped VLF hiss, saucers, ELF hiss, and Io-related Jovian decametric radiation may not.

Taylor, W. W. L.

Frequency of light-flashes induced by Cerenkov radiation from heavy cosmic-ray nuclei

The expected frequency was calculated for light flashes induced in the dark-adapted eye by Cerenkov radiation from the flux of heavy nuclei that exists in space beyond the geomagnetic field. The expected frequency of light flashes depends on the threshold number of photons that must be absorbed in a rod cluster. The results of the calculation are presented as a curve of the mean frequency of light flashes versus the threshold number of absorbed photons. The results are not sensitive to variations in the path length from 5 to 15 grams per square centimeter of water-equivalent before the nucleus reaches the retina. Calculations were based on the fluxes and energy spectra of galactic cosmic ray nuclei of helium to iron, measured at a time of minimum solar modulation. The expected light flash frequencies induced by Cerenkov radiation are consistent with the frequencies reported by the astronauts on Apollo missions 11 through 14.

Madey, R.

Properties of a silica aerogel Cerenkov radiator used in a cosmic ray telescope

A silica aerogel Cerenkov radiator with a refractive index of 1.06 has been flown in a balloon borne cosmic ray telescope. Clear separation of the elements in the iron group was achieved even at high energies. No detectable scintillation component was found. Some optical properties of the silica aerogel used in this flight are presented.

Cantin, M.

The coherent Cerenkov radiated power from a group of field-aligned test particles in a magnetoplasma

An expression is derived that describes the coherent Cerenkov radiated power from a group of test particles in a plasma medium moving parallel to a magnetic field. In this analysis, each particle has an arbitrary position and velocity along a field line and, as a consequence, both the spatial and temporal coherence of the radiation are considered. As an example, it is demonstrated that a monoenergetic electron beam consisting of small pulses can generate wave powers well above incoherent levels if the pulse spacing is comparable to an integer number of emission wavelengths. It is also shown that, if the beam particles have a velocity spread, Delta-V, the wave powers will decrease in time due to the reduced temporal coherence of the particle radiators, where this coherence scales as 1/Delta-V. This latter effect applies to any charged particle beam propagating in a magnetoplasma, because even an initially monoenergetic beam becomes thermalized by electrostatic wave-particle interactions reducing the radiated power.

Farrell, W. M.

Silicone Cerenkov-Radiator Material

Dyes enhance visible output. Three fluorescent dyes combine to increase output of silicone material that normally has low yield of visible Cerenkov radiation by converting large amount of available ultraviolet photons into visible light.

Balasubrahmanyan, V.

Visual phenomena induced by relativistic carbon ions with and without Cerenkov radiation

Exposing the human eye to individual carbon ions moving at relativistic speeds results in visual phenomena that include point flashes, streaks, and larger diffuse flashes. The diffuse flashes have previously been observed by astronauts in space but not in laboratory experiments with particles of high atomic number and energy. They are observed only when the nucleus moves fast enough to generate Cerenkov radiation.

Mcnulty, P. J.

Coherent Cerenkov radiation from the Spacelab 2 electron beam

The plasma environment of the Spacelab 2 mission was investigated through the deployment of the Plasma Diagnostics Package (PDP) by the Space Shuttle Orbiter and the Orbiter's ejection of a continuous 1-keV/50-mA electron beam along a field line. As the PDP flew by the beam, its plasma-wave instrument detected intense whistler-mode radiation originating from the beam. A detailed model has been developed of the coherent Cerenkov emission process, using a one-dimensional computer simulation of the beam to model the expected phase space structure of the electrons. The power calculated for the modeled 200-m beam segment can easily account for the measured whistler mode wave power.

Farrell, W. M.

Near threshold response of a wave shifted Cerenkov radiator to heavy ions

The response of Pilot 425 to heavy ions with energies less than 600 MeV/amu beta approximately 0.8 is examined both theoretically and experimentally. Measurements are presented from an experiment which employed a Ne-20 beam at many energies below 575 MeV/amu. The signal is assumed to come from three sources: (1) Cerenkov light from the heavy ion, (2) Cerenkov light from secondary electrons, and (3) scintillation of the radiator. It is found that the effective index of refraction is 1.518 and that scintillation is present at a level of approximately 2.7 percent of the Cerenkov signal for beta = 1 for Ne-20. The first of these values differs from values previously quoted in the literature.

Ahlen, S. P.

Light flash phenomena induced by HzE particles

Astronauts and Apollo and Skylab missions have reported observing a variety of visual phenomena when their eyes are closed and adapted to darkness. These phenomena have been collectively labelled as light flashes. Visual phenomena which are similar in appearance to those observed in space have been demonstrated at the number of accelerator facilities by expressing the eyes of human subjects to beams of various types of radiation. In some laboratory experiments Cerenkov radiation was found to be the basis for the flashes observed while in other experiments Cerenkov radiation could apparently be ruled out. Experiments that differentiate between Cerenkov radiation and other possible mechanisms for inducing visual phenomena was then compared. The phenomena obtained in the presence and absence of Cerenkov radiation were designed and conducted. A new mechanism proposed to explain the visual phenomena observed by Skylab astronauts as they passed through the South Atlantic Anomaly, namely nuclear interactions in and near the sensitive layer of the retina, is covered. Also some studies to search for similar transient effects of space radiation on sensors and microcomputer memories are described.

Mcnulty, P. J.

Generation and propagation of electromagnetic waves in the magnetosphere

Characteristics of broadband ELF, VLF, and LF emissions in the magnetosphere were calculated assuming incoherent Cerenkov radiation from magnetospheric electrons with energies from 50 eV to 50 keV. Calculations were included to determine the ray paths of the emitted waves. A diffusive equilibrium model of the magnetosphere with an ionosphere, plasmapause, and a centered dipole magnetic field was used. Ray path calculations were done in three dimensions. Using simultaneous energetic electron and VLF data, comparisons were made between calculated and observed VLF hiss. Assuming a wave normal angle six degrees from the resonance cone angle, the calculated spectral densities are both two orders of magnitude below the observed spectral densities. It seems unlikely that VLF hiss is produced by incoherent Cerenkov radiation. The observed spectral shape of V-shaped VLF hiss is similar to that calculated from incoherent Cerenkov radiation.

Taylor, W. W. L.

Fast timing with µRWELL-PICOSEC detector technology

The µWELL-PICOSEC detector, which is based on Resistive Micro-Well (µRWELL) technology, is a novel concept for fast timing gaseous detectors that can provide timing resolution in the tens of picosecond range, making it ideal candidate for time-of-flight (TOF) technology for particle identification (PID) in particle physics experiments as well as for future medical instrumentation. The µRWELL-PICOSEC concept is based on a Cerenkov radiator that produces Cerenkov photons from high energetic charged particles, a photocathode layer that converts the Cerenkov photons into primary electrons, a µRWELL amplification layer that multiply the electrons through amplification in a CF4-based gas mixture and a pad-segmentation anode readout coupled with fast timing electronics to provide fast signal. Beam tests were carried out at the CERN SPS H4 beamline in summer 2023 and 2024. Preliminary results show timing performance of the order of 23 ps achievable with µRWELL-PICOSEC prototype. and position scan of the 100-pads of a multi-channel prototype was also performed to study time response uniformity of large area detector. In this talk, after a brief overview of the PICOSEC technology, we will present recent results with different single channel µRWELL-PICOSEC prototype designs and also the position scan results of the 100-pads large prototype to study timing response uniformity for large area µRWELL-PICOSEC detector. Finally, we will discuss the ongoing R&D effort to further improve the timing resolution and allow good position capabilities through charge sharing for large area.

Gnanvo, Kondo

Detection of the isotopes of heavy cosmic ray nuclei

A counter telescope designed to detect and resolve the isotopic composition of cosmic ray nuclei heavier than neon is being prepared. The telescope consists of a rather conventional charge measuring array using two scintillator elements and two solid Cerenkov radiators of differing refractive index. The mass measurement is obtained by combining the velocity information from one or both of the Cerenkov radiators operating near their threshold with residual range measured in a block of nuclear emulsion. Path length corrections and particle location in the emulsions is provided by a spark chamber fired in coincidence with potentially suitable particles. The telescope has a geometry factor of 530 sq cm sr roughly. It should be able to resolve the isotopes of iron over the energy range of 300 to 720 Mev/n and those of neon over 300 to 400 MeV/n. The expected response and characteristics of the telescope are described in detail and the sensitivity to rare isotopes discussed.

Gilman, C. M.

The Track Imaging Cerenkov Experiment

We describe a dedicated cosmic-ray telescope that explores a new method for detecting Cerenkov radiation from high-energy primary cosmic rays and the large particle air shower they induce upon entering the atmosphere. Using a camera comprising 16 multi-anode photomultiplier tubes for a total of 256 pixels, the Track Imaging Cerenkov Experiment (TrICE) resolves substructures in particle air showers with 0.086deg resolution. Cerenkov radiation is imaged using a novel two-part optical system in which a Fresnel lens provides a wide-field optical trigger and a mirror system collects delayed light with four times the magnification. TrICE records well-resolved cosmic-ray air showers at rates ranging between 0.01-0.1 Hz.

Wissel, S. A.