Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CARDIOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Night‐time electromechanical activation time, pulsatile hemodynamics, and discharge outcomes in patients with acute heart failure

Abstract Aims Both electromechanical activation time (EMAT) and pulsatile hemodynamics measured during the hospitalization course are useful in the prediction of cardiovascular outcomes in patients with acute heart failure syndrome (AHFS). We investigated whether night‐time monitoring of EMAT with the ambulatory acoustic cardiography is superior to the measures of pulsatile hemodynamics for prediction of AHFS post‐discharge outcomes. Methods and results A total of 97 patients (71.1 ± 15.4 years old, 81% male, and 73.8% systolic heart failure) hospitalized for AHFS were included. Before discharge, 24 h ambulatory acoustic cardiography and a comprehensive echocardiographic and pulsatile hemodynamic study were performed to assess the mean 24 h, daytime, and night‐time EMAT, carotid systolic blood pressure (SBP) and pulse pressure (PP), amplitude of the reflected pressure wave from a decomposed carotid pressure wave (Pb), and carotid–femoral pulse wave velocity (cfPWV), in addition to measurement of N‐terminal pro‐brain natriuretic peptide (NT‐proBNP) levels. During a mean follow‐up of 389 ± 281 days, 49 patients (50.5%) experienced events including re‐hospitalization for heart failure, myocardial infarction, stroke, or death. Pulsatile hemodynamics, including carotid SBP and PP and Pb, but not cfPWV, and night‐time EMAT, but not daytime EMAT, significantly predicted post‐discharge events when age and NT‐proBNP were accounted for (all P < 0.05). In a final model with adjustment for age and NT‐proBNP, night‐time EMAT, but not Pb, significantly predicted post‐discharge events [hazard ratio per 1 SD and 95% confidence intervals: 1.33 (1.05–1.69), P < 0.05]. Conclusion Pre‐discharge night‐time EMAT may be a better predictor for post‐discharge adverse events than the measures of the pulsatile hemodynamics in patients with AHFS.

Chang, Chun‐Chin↗

A high-sensitivity tunable two-beam fiber-coupled high-density magnetometer with laser heating

Atomic magnetometers (AM) are finding many applications in biomagnetism, national security, industry, and science. Fiber-coupled (FC) designs promise to make them compact and flexible for operation. Most FC designs are based on a single-beam configuration or electrical heating. Here, we demonstrate a two-beam FC AM with laser heating that has 5 fT/Hz 1/2 sensitivity at low frequency (50 Hz), which is higher than that of other fiber-coupled magnetometers and can be improved to the sub-femtotesla level. Here, this magnetometer is widely tunable from DC to very high frequencies (as high as 100 MHz; the only issue might be the application of a suitable uniform and stable bias field) with a sensitivity under 10 fT/Hz 1/2 and can be used for magneto-encephalography (MEG), magneto-cardiography (MCG), underground communication, ultra-low MRI/NMR, NQR detection, and other applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The atomic magnetometer: A new era in biomagnetism

The high cost and impracticality of SQUID (Superconducting QUantum Interference Device) magnetometers has limited the expansion of magnetoencephalography (MEG) and magnetocardiography (MCG), especially in countries where the cost of liquid helium is high. A recent breakthrough, however, has the potential to radically change this situation. In 2003, a group at Princeton University demonstrated an atomic magnetometer, known as the SERF (spin-exchange free relaxation) magnetometer, with unprecedented sensitivity. Since then, several research groups have utilized SERF magnetometers to record MEG, MCG, and fetal MCG signals. Despite some modest drawbacks, it now seems almost certain that SERF magnetometers can replace SQUIDs for many applications. With a price tag that is likely to be far less than that of SQUIDs, SERF magnetometers can propel the next wave of growth in biomagnetism.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On the feasibility of using the spiral beam formalism for analysis of cardiograms

A contour analysis method based on a spiral beam formalism is proposed for cardiogram classification. A cardiogram contour proximity metric is introduced in spiral beam intensity space. Normal and infarction cardiograms are classified using the proposed method. The method is shown to provide adequate results in most of the cases examined. (paper)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-A-12A-09: Absolute Blood Flow Measurement in a Cardiac Phantom Using Low Dose CT

Purpose: To investigate a first pass analysis technique to measure absolute flow from low dose CT images in a cardiac phantom. This technique can be combined with a myocardial mass assignment to yield absolute perfusion using only two volume scans and reduce the radiation dose to the patient. Methods: A four-chamber cardiac phantom and perfusion chamber were constructed from poly-acrylic and connected with tubing to approximate anatomical features. The system was connected to a pulsatile pump, input/output reservoirs and power contrast injector. Flow was varied in the range of 1-2.67 mL/s with the pump operating at 60 beats/min. The system was imaged once a second for 14 seconds with a 320-row scanner (Toshiba Medical Systems) using a contrast-enhanced, prospective-gated cardiac perfusion protocol. Flow was calculated by the following steps: subsequent images of the perfusion volume were subtracted to find the contrast entering the volume; this was normalized by an upstream, known volume region to convert Hounsfield (HU) values to concentration; this was divided by the subtracted images time difference. The technique requires a relatively stable input contrast concentration and no contrast can leave the perfusion volume before the flow measurement is completed. Results: The flow calculated from the images showed an excellent correlation with the known rates. The data was fit to a linear function with slope 1.03, intercept 0.02 and an R{sup 2} value of 0.99. The average root mean square (RMS) error was 0.15 mL/s and the average standard deviation was 0.14 mL/s. The flow rate was stable within 7.7% across the full scan and served to validate model assumptions. Conclusion: Accurate, absolute flow rates were measured from CT images using a conservation of mass model. Measurements can be made using two volume scans which can substantially reduce the radiation dose compared with current dynamic perfusion techniques.

60 APPLIED LIFE SCIENCES↗

TU-F-BRF-04: Registration of 3D Transesophageal Echocardiography and X-Ray Fluoroscopy Using An Inverse Geometry X-Ray System

Purpose: To develop a method for the fusion of 3D echocardiography and Scanning-Beam Digital X-ray (SBDX) fluoroscopy to assist with catheter device and soft tissue visualization during interventional procedures. Methods: SBDX is a technology for low-dose inverse geometry x-ray fluoroscopy that performs digital tomosynthesis at multiple planes in real time. In this study, transesophageal echocardiography (TEE) images were fused with SBDX images by estimating the 3D position and orientation (the “pose”) of the TEE probe within the x-ray coordinate system and then spatially transforming the TEE image data to match this pose. An initial pose estimate was obtained through tomosynthesis-based 3D localization of points along the probe perimeter. Position and angle estimates were then iteratively refined by comparing simulated projections of a 3D probe model against SBDX x-ray images. Algorithm performance was quantified by imaging a TEE probe in different known orientations and locations within the x-ray field (0-30 degree tilt angle, up to 50 mm translation). Fused 3D TEE/SBDX imaging was demonstrated by imaging a tissue-mimicking polyvinyl alcohol cylindrical cavity as a catheter was navigated along the cavity axis. Results: Detected changes in probe tilt angle agreed with the known changes to within 1.2 degrees. For a 50 mm translation along the source-detector axis, the detected translation was 50.3 mm. Errors for in-plane translations ranged from 0.1 to 0.9 mm. In a fused 3D TEE/SBDX display, the catheter device was well visualized and coincident with the device shadow in the TEE images. The TEE images portrayed phantom boundaries that were not evident under x-ray. Conclusion: Registration of soft tissue anatomy derived from TEE imaging and device imaging from SBDX x-ray fluoroscopy is feasible. The simultaneous 3D visualization of these two modalities may be useful in interventional procedures involving the navigation of devices to soft tissue anatomy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗