Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CALCIUM 50”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

WE-FG-207B-12: Quantitative Evaluation of a Spectral CT Scanner in a Phantom Study: Results of Spectral Reconstructions

Purpose: To evaluate the quantitative image quality of spectral reconstructions of phantom data from a spectral CT scanner. Methods: The spectral CT scanner (IQon Spectral CT, Philips Healthcare) is equipped with a dual-layer detector and generates conventional 80-140 kVp images and variety of spectral reconstructions, e.g., virtual monochromatic (VM) images, virtual non-contrast (VNC) images, iodine maps, and effective atomic number (Z) images. A cylindrical solid water phantom (Gammex 472, 33 cm diameter and 5 cm thick) with iodine (2.0-20.0 mg I/ml) and calcium (50-600 mg/ml) rod inserts was scanned at 120 kVp and 27 mGy CTDIvol. Spectral reconstructions were evaluated by comparing image measurements with theoretical values calculated from nominal rod compositions provided by the phantom manufacturer. The theoretical VNC was calculated using water and iodine basis material decomposition, and the theoretical Z was calculated using two common methods, the chemical formula method (Z1) and the dual-energy ratio method (Z2). Results: Beam-hardening-like artifacts between high-attenuation calcium rods (≥300 mg/ml, >800 HU) influenced quantitative measurements, so the quantitative analysis was only performed on iodine rods using the images from the scan with all the calcium rods removed. The CT numbers of the iodine rods in the VM images (50∼150 keV) were close to theoretical values with average difference of 2.4±6.9 HU. Compared with theoretical values, the average difference for iodine concentration, VNC CT number and effective Z of iodine rods were −0.10±0.38 mg/ml, −0.1±8.2 HU, 0.25±0.06 (Z1) and −0.23±0.07 (Z2). Conclusion: The results indicate that the spectral CT scanner generates quantitatively accurate spectral reconstructions at clinically relevant iodine concentrations. Beam-hardening-like artifacts still exist when high-attenuation objects are present and their impact on patient images needs further investigation. YY is an employee of Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

Nuclear Data Sheets for A=50

The experimental nuclear structure and decay data are evaluated for all the known nuclides of mass 50 (Cl, Ar, K, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Ni). Here, detailed evaluated nuclear structure information are presented in individual decay and reaction datasets and the best values are recommended in the Adopted dataset for level properties, γ and β radiations, and other spectroscopic information. No excited states are known in 50Cl and 50Ni, and limited information is available for 50 Ar, 50 K, 50 Fe and 50 Co. This work supersedes earlier evaluations of A=50 by 2011El01, 1995Bu09, 1990Bu18, 1984Al29, and 1976Au07.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reexamination of the neutron skin thickness using neutron removal cross sections

The neutron removal cross section [{sigma}{sub -N}(Z)] is defined for the projectile-like fragment isotopes and extended to the lower Z isotopes in the projectile fragmentation reaction. The cross sections of fragments in 1 A GeV even {sup 42-52}Ca+{sup 12}C projectile fragmentation reactions are calculated using the statistical abrasion-ablation model. The correlations between {sigma}{sub -N}(Z) of different fragment isotopes and neutron skin thickness (S{sub n}) for finite neutron-rich nuclei are revisited. Good linear {sigma}{sub -N}(Z)-S{sub n} correlations are observed in fragment isotopes, and it is suggested that {sigma}{sub -N}(Z) be used as an observable to determine S{sub n} of neutron-rich nucleus in addition to {sigma}{sub -N} for isotopes of the projectile nucleus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data Sheets for A = 50

The experimental nuclear spectroscopic data for known nuclides of mass number 50 (Cl,Ar,K,Ca,Sc,Ti,V, Cr,Mn,Fe,Co,Ni) have been evaluated and presented together with Adopted properties for levels and {gamma} rays. This evaluation has been carried out about 15 years after the previous one by Thomas Burrows (1995Bu29). Except for {sup 50}Sc and {sup 50}V, extensive new data have become available for all the other nuclides in the intervening years. The data for {sup 50}Sc and {sup 50}V have also been checked again in detail and several changes made. No data are yet available for excited states in {sup 50}Cl, {sup 50}Ar and {sup 50}Ni. This work supersedes earlier evaluations (1995Bu29, 1990Bu18, 1984Al29, 1976Au07) of A=50 nuclides.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

All possible ternary fragmentations of {sup 252}Cf in collinear configuration

All possible ternary fragmentations in fission of {sup 252}Cf are studied in collinear configuration within a spherical approximation using the recently proposed ''three cluster model.'' The potential energy surface of collinear configuration exhibits a strong valley around {sup 48}Ca and its neighboring nuclei {sup 50}Ca, {sup 54}Ti, and {sup 60}Cr. Such strong minima are not seen in the potential energy surface of an equatorial configuration. As a consequence of strong minima in the potential, the overall relative yield is higher for the ternary fragmentation with {sup 48}Ca, {sup 50}Ca, {sup 54}Ti, {sup 60}Cr, and {sup 82}Ge as the third fragment. The results of potential energy and relative yield calculations reveal that collinear configuration increases the probability of emission of heavy fragments like {sup 48}Ca (doubly magic nucleus) and its neighboring nuclei as the third fragment. The obtained results indicate that the collinear configuration is the preferred configuration for intermediate nuclei ({sup 48}Ca, {sup 50}Ca, {sup 54}Ti, and {sup 60}Cr) as the third fragment in particle accompanied fission while the equatorial configuration may be a preferred configuration for light nuclei ({sup 4}He, {sup 10}Be) as the third fragment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dual-energy cone-beam CT with a flat-panel detector: Effect of reconstruction algorithm on material classification

Purpose: Cone-beam CT (CBCT) with a flat-panel detector (FPD) is finding application in areas such as breast and musculoskeletal imaging, where dual-energy (DE) capabilities offer potential benefit. The authors investigate the accuracy of material classification in DE CBCT using filtered backprojection (FBP) and penalized likelihood (PL) reconstruction and optimize contrast-enhanced DE CBCT of the joints as a function of dose, material concentration, and detail size. Methods: Phantoms consisting of a 15 cm diameter water cylinder with solid calcium inserts (50–200 mg/ml, 3–28.4 mm diameter) and solid iodine inserts (2–10 mg/ml, 3–28.4 mm diameter), as well as a cadaveric knee with intra-articular injection of iodine were imaged on a CBCT bench with a Varian 4343 FPD. The low energy (LE) beam was 70 kVp (+0.2 mm Cu), and the high energy (HE) beam was 120 kVp (+0.2 mm Cu, +0.5 mm Ag). Total dose (LE+HE) was varied from 3.1 to 15.6 mGy with equal dose allocation. Image-based DE classification involved a nearest distance classifier in the space of LE versus HE attenuation values. Recognizing the differences in noise between LE and HE beams, the LE and HE data were differentially filtered (in FBP) or regularized (in PL). Both a quadratic (PLQ) and a total-variation penalty (PLTV) were investigated for PL. The performance of DE CBCT material discrimination was quantified in terms of voxelwise specificity, sensitivity, and accuracy. Results: Noise in the HE image was primarily responsible for classification errors within the contrast inserts, whereas noise in the LE image mainly influenced classification in the surrounding water. For inserts of diameter 28.4 mm, DE CBCT reconstructions were optimized to maximize the total combined accuracy across the range of calcium and iodine concentrations, yielding values of ∼88% for FBP and PLQ, and ∼95% for PLTV at 3.1 mGy total dose, increasing to ∼95% for FBP and PLQ, and ∼98% for PLTV at 15.6 mGy total dose. For a fixed iodine concentration of 5 mg/ml and reconstructions maximizing overall accuracy across the range of insert diameters, the minimum diameter classified with accuracy >80% was ∼15 mm for FBP and PLQ and ∼10 mm for PLTV, improving to ∼7 mm for FBP and PLQ and ∼3 mm for PLTV at 15.6 mGy. The results indicate similar performance for FBP and PLQ and showed improved classification accuracy with edge-preserving PLTV. A slight preference for increased smoothing of the HE data was found. DE CBCT discrimination of iodine and bone in the knee was demonstrated with FBP and PLTV at 6.2 mGy total dose. Conclusions: For iodine concentrations >5 mg/ml and detail size ∼20 mm, material classification accuracy of >90% was achieved in DE CBCT with both FBP and PL at total doses <10 mGy. Optimal performance was attained by selection of reconstruction parameters based on the differences in noise between HE and LE data, typically favoring stronger smoothing of the HE data, and by using penalties matched to the imaging task (e.g., edge-preserving PLTV in areas of uniform enhancement)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Probing the shell structure near {sup 54}Ca and {sup 100}Sn

In this contribution results will be reported from two recent experiments at the GSI Fragmentseparator (FRS). The first experiment is using one-nucleon knockout with relativistic fragments from a 500 AMeV {sup 86}Kr primary beam to probe the single-particle structure in {sup 49}Ca and {sup 55}Ti. From the one-neutron knockout in the neutron-rich nuclei {sup 50}Ca and the N = 34 nucleus {sup 56}Ti cross sections and momentum distributions were deduced allowing the determination of angular momentum values and spectroscopic factors for individual states.In the second experiment decay spectroscopy of {sup 100}Sn and nuclei in its vicinity was performed. The nuclei of interest were produced using the fragmentation of a 1 AGeV {sup 124}Xe primary beam. The RISING gamma-ray detector array was used in close geometry to detect gamma-decay following isomeric as well as beta decays. Aside from the production of more that 200 {sup 100}Sn nuclei, several new isotopes and isomers were discovered.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Lifetime Measurements of the Neutron-Rich N=30 Isotones {sup 50}Ca and {sup 51}Sc: Orbital Dependence of Effective Charges in the fp Shell

The lifetimes of the first excited states of the N=30 isotones {sup 50}Ca and {sup 51}Sc have been determined using the Recoil Distance Doppler Shift method in combination with the CLARA-PRISMA spectrometers. This is the first time such a method is applied to measure lifetimes of neutron-rich nuclei populated via a multinucleon transfer reaction. This extends the lifetime knowledge beyond the f{sub 7/2} shell closure and allows us to derive the effective proton and neutron charges in the fp shell near the doubly magic nucleus {sup 48}Ca, using large-scale, shell-model calculations. These results indicate an orbital dependence of the core polarization along the fp shell.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Stability of {sup 248–254}Cf isotopes against alpha and cluster radioactivity

Stability of {sup 248–254}Cf nuclei against alpha and cluster emissions is studied within our Coulomb and proximity potential model (CPPM). It is found that these nuclei are stable against light clusters (except alpha particles) and unstable against heavy cluster (A{sub 2}≥40) emissions. For heavy cluster emissions the daughter nuclei lead to doubly magic {sup 208}Pb or the neighbouring one. The effects of quadrupole and hexadecapole deformations of parent nuclei, daughter nuclei and emitted cluster on half lives are also studied. The computed alpha decay half life values (including quadrupole deformation β{sub 2}) are in close agreement with experimental data. Inclusion of quadrupole deformation reduces the height and width of the barrier (increases the barrier penetrability) and hence half life decreases. -- Highlights: •{sup 248–254}Cf parents are stable against light clusters (except alpha particles) and are unstable against heavy clusters ({sup 46}Ar, {sup 48,50}Ca etc.). •For the case of heavy cluster emissions the daughter nuclei are doubly magic {sup 208}Pb or neighbouring one. •The alpha decay half lives are in agreement with experimental data. •The cluster decay half lives decrease with the inclusion of quadrupole deformation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

True ternary fission, the collinear cluster tripartition (CCT) of {sup 252}Cf

In systematic work over the last decade (see Pyatkov et al. [12] and refs therein), the ternary fission decay of heavy nuclei, in {sup 235}U(n,fff) and {sup 252}Cf(sf) has been studied in a collinear geometry. The name used for this process is (CCT), with three fragments of similar size in a collinear decay, it is the true ternary fission. This decay has been observed in spontaneous fission as well as in a neutron induced reaction. The measurements are based on different experimental set-ups, with binary coincidences containing TOF and energy determinations. With two detector telescopes placed at 180 Degree-Sign , the measurements of masses and energies of each of the registered two fragments, give complete kinematic solutions. Thus the missing mass events in binary coincidences can be determined, these events are obtained by blocking one of the lighter fragments on a structure in front of the detectors. The relatively high yield of CCT (more than 10{sup -3} per binary fission) is explained. It is due to the favourable Q-values (more positive than for binary) and the large phase space of the ternary CCT-decay, dominated by three (magic) clusters: e.g. isotopes of Sn, Ca and Ni, {sup 132}Sn+{sup 50}Ca+{sup 70}Ni. It is shown that the collinear (prolate) geometry has the favoured potential energy relative to the oblate shapes. The ternary fission is considered to be a sequential process. With this assumption the kinetic energies of the fragments have been calculated by Vijay et al.. The third fragments have very low kinetic energies (below 20 MeV) and have thus escaped their detection in previous work on 'ternary fission', where in addition an oblate shape and a triangle for the momentum vectors have been assumed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cold reaction valleys in the radioactive decay of superheavy {sup 286}112, {sup 292}114, and {sup 296}116 nuclei

Cold reaction valleys in the radioactive decay of superheavy nuclei {sup 286}112, {sup 292}114, and {sup 296}116 are studied taking Coulomb and Proximity Potential as the interacting barrier. It is found that in addition to alpha particle, {sup 8}Be, {sup 14}C, {sup 28}Mg, {sup 34}Si, {sup 50}Ca, etc. are optimal cases of cluster radioactivity since they lie in the cold valleys. Two other regions of deep minima centered on {sup 208}Pb and {sup 132}Sn are also found. Within our Coulomb and Proximity Potential Model half-life times and other characteristics such as barrier penetrability, decay constant for clusters ranging from alpha particle to {sup 68}Ni are calculated. The computed alpha half-lives match with the values calculated using Viola-Seaborg-Sobiczewski systematics. The clusters {sup 8}Be and {sup 14}C are found to be most probable for emission with T{sub 1/2} < 10{sup 30} s. The alpha-decay chains of the three superheavy nuclei are also studied. The computed alpha-decay half-lives are compared with the values predicted by Generalized Liquid Drop Model and they are found to match reasonably well.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An interval of high salinity in ancient Gale crater lake on Mars

Precipitated minerals, including salts, are primary tracers of atmospheric conditions and water chemistry in lake basins. Ongoing in situ exploration by the Curiosity rover of Hesperian (around 3.3–3.7 Gyr old) sedimentary rocks within Gale crater on Mars has revealed clay-bearing fluvio-lacustrine deposits with sporadic occurrences of sulfate minerals, primarily as late-stage diagenetic veins and concretions. In this work, we report bulk enrichments, disseminated in the bedrock, of 30–50 wt% calcium sulfate intermittently over about 150 m of stratigraphy, and of 26–36 wt% hydrated magnesium sulfate within a thinner section of strata. We use geochemical analysis, primarily from the ChemCam laser-induced breakdown spectrometer, combined with results from other rover instruments, to characterize the enrichments and their lithology. The deposits are consistent with early diagenetic, pre-compaction salt precipitation from brines concentrated by evaporation, including magnesium sulfate-rich brines from extreme evaporative concentration. This saline interval represents a substantial hydrological perturbation of the lake basin, which may reflect variations in Mars’ obliquity and orbital parameters. Our findings support stepwise changes in Martian climate during the Hesperian, leading to more arid and sulfate-dominated environments as previously inferred from orbital observations.

58 GEOSCIENCES↗

TU-F-12A-06: BEST IN PHYSICS (IMAGING) - A Novel Catheter-Based Radionuclide Imaging System to Characterize Atherosclerotic Plaque

Purpose: Atherosclerosis underlies coronary artery diseases, the leading cause of death in the United States and worldwide. In this study, we developed a novel catheter-based radionuclide imaging (CRI) system to image 18F-fluorodeoxyglucose (18F-FDG), a radionuclide, a marker of vascular inflammation, in murine carotid arteries and characterized the system for spatial resolution from multiple scintillating materials. Methods: The catheter system includes 35 mm and 8 mm fixed focal length lenses, which are subsequently connected to a CMOS camera and fiber holder. The distal ferrule of an image bundle is terminated with a wide-angle lens. The novelty of this system is a scintillating balloon with a crystal tip in the front of the wide angle lens to image light from the decay of 18F-FDG emission signal. The scintillating balloon is fabricated from 1mL of silicone RTV catalyst mixed with 1 mL base and 50 mg/mL calcium fluoride doped with Europium (CaF2:Eu). To identify the optimal scintillating materials with respect to resolution, we calculated modulation transfer function (MTF) of Yttrium Aluminum Garnet doped with Cerium (YAG:Ce), anthracene, and CaF2:Eu phosphors using a thin line optical phantom (Fig. 1a-1b). Macrophage-rich FVB murine atherosclerotic carotid plaque model (n = 4) was used in ex vivo experiments. Confirmatory imaging was also performed by an external optical imaging system (IVIS-200). Results: Analysis of the different phosphors (Fig 1b) showed that CaF2:Eu enabled the best resolution of 1.2μm. The CRI system visualized 18F-FDG in atherosclerotic plaques (Fig. 1d). The ligated left carotid (LR) artery exhibited 4× higher 18F-FDG signal intensity compared to the non-ligated right carotid (negative control) artery (1.65×10{sup 2} ±4.07×10{sup 1} vs. 4.44×10{sup 1}±2.17×10{sup 0}, A.U., p = 0.005) and confirmed with IVIS-200 (Fig. 1d). Conclusion: This CRI system enables high-resolution and sensitive detection of 18F-FDG uptake by murine atherosclerotic plaques.

60 APPLIED LIFE SCIENCES↗

Elemental Modes of Occurrence in an Illinois #6 Coal and Fractions Prepared by Physical Separation Techniques at a Coal Preparation Plant

In order to gain better insight into elemental partitioning between clean coal and tailings, modes of occurrence have been determined for a number of major and trace elements (S, K, Ca, V, Cr, Mn, Fe, Zn, As, Se, Pb) in an Illinois No.6 coal and fractions prepared by physical separation methods at a commercial coal preparation plant. Elemental modes of occurrence were largely determined directly by XAFS or Moessbauer spectroscopic methods because the concentrations of major minerals and wt.% ash were found to be highly correlated for this coal and derived fractions, rendering correlations between individual elements and minerals ambiguous for inferring elemental modes of occurrence. Of the major elements investigated, iron and potassium are shown to be entirely inorganic in occurrence. Most (90%) of the iron is present as pyrite, with minor fractions in the form of clays and sulfates. All potassium is present in illitic clays. Calcium in the original coal is 80-90% inorganic and is divided between calcite, gypsum, and illite, with the remainder of the calcium present as carboxyl-bound calcium. In the clean coal fraction, organically associated Ca exceeds 50% of the total calcium. This organically-associated form of Ca explains the poorer separation of Ca relative to both K and ash. Among the trace elements, V and Cr are predominantly inorganically associated with illite, but minor amounts (5-15% Cr, 20-30% V) of these elements are also organically associated. Estimates of the V and Cr contents of illite are 420 ppm and 630 ppm, respectively, whereas these elements average 20 and 8 ppm in the macerals. Arsenic in the coal is almost entirely associated with pyrite, with an average As content of about 150 ppm, but some As ({approx} 10%) is present as arsenate due to minor oxidation of the pyrite. The mode of occurrence of Zn, although entirely inorganic, is more complex than normally noted for Illinois basin coals; about 2/3 is present in sphalerite, with lesser amounts associated with illite and a third form yet to be conclusively identified. The non-sulfide zinc forms are removed predominantly by the first stage of separation (rotary breaker), whereas the sphalerite is removed by the second stage (heavy media). Germanium is the only trace element determined to have a predominantly organic association.

01 COAL, LIGNITE, AND PEAT↗

Modeling acid-gas generation from boiling chloride brines

This study investigates the generation of HCl and other acid gases from boiling calcium chloride dominated waters at atmospheric pressure, primarily using numerical modeling. The main focus of this investigation relates to the long-term geologic disposal of nuclear waste at Yucca Mountain, Nevada, where pore waters around waste-emplacement tunnels are expected to undergo boiling and evaporative concentration as a result of the heat released by spent nuclear fuel. Processes that are modeled include boiling of highly concentrated solutions, gas transport, and gas condensation accompanied by the dissociation of acid gases, causing low-pH condensate. Simple calculations are first carried out to evaluate condensate pH as a function of HCl gas fugacity and condensed water fraction for a vapor equilibrated with saturated calcium chloride brine at 50-150 C and 1 bar. The distillation of a calcium-chloride-dominated brine is then simulated with a reactive transport model using a brine composition representative of partially evaporated calcium-rich pore waters at Yucca Mountain. Results show a significant increase in boiling temperature from evaporative concentration, as well as low pH in condensates, particularly for dynamic systems where partial condensation takes place, which result in enrichment of HCl in condensates. These results are in qualitative agreement with experimental data from other studies. The combination of reactive transport with multicomponent brine chemistry to study evaporation, boiling, and the potential for acid gas generation at the proposed Yucca Mountain repository is seen as an improvement relative to previously applied simpler batch evaporation models. This approach allows the evaluation of thermal, hydrological, and chemical (THC) processes in a coupled manner, and modeling of settings much more relevant to actual field conditions than the distillation experiment considered. The actual and modeled distillation experiments do not represent expected conditions in an emplacement drift, but nevertheless illustrate the potential for acid-gas generation at moderate temperatures (<150 C).

54 ENVIRONMENTAL SCIENCES↗

Effects of calcium gluconate on lipopolysaccharide-induced acute lung injury in mice

Highlights: • Calcium gluconate may decrease lipopolysaccharide-induced lung histological changes. • Exudation of neutrophils could be relieved by calcium gluconate. • Inflammatory cytokines release in airways could be reduced by calcium gluconate. • Calcium gluconate could inhibit the ERK phosphorylation. Lipopolysaccharide (LPS), which can cause acute airway inflammatory reactions, constitutes one of the most common substances to establish acute lung injury (ALI) models in mice. Studies suggest that calcium gluconate offers the possibility of suppressing the immune response, and this study was intended to explore the effects of calcium gluconate on LPS-induced ALI in mice. Mice inhaled with LPS were intraperitoneally injected with calcium gluconate (12.5, 25, 50 mg/kg). IL-1β, IL-6 and TNF-α levels in bronchoalveolar lavage fluid (BALF) were determined by ELISA. The expression of signaling proteins, phosphorylation extracellular regulated protein kinases (p-ERK), was detected using Western Blot in lung tissues. In our study, the release of inflammatory cytokines IL-1β, IL-6 and TNF-α in BALF increased after inhalation of LPS. Post-treatment with calcium gluconate inhibited LPS-induced airway inflammatory injury and the release of inflammatory cytokines. In addition, LPS promoted the expression of signaling protein p-ERK while calcium gluconate was capable of reversing this change. Overall, calcium gluconate inhibits LPS-induced ALI in mice, which may take effects through the inhibition of ERK phosphorylation.

60 APPLIED LIFE SCIENCES↗

Predictive Assessment of the Chemical Composition of Coal Ash in Reserve at U.S. Disposal Sites

In the United States, more than 2 Gt of coal combustion residuals (i.e., coal ash) are stored in hundreds of disposal units. Recent federal regulations mandate the closure or retrofitting of most coal ash impoundments, presenting significant challenges for waste management. These regulatory pressures also present opportunities to reuse coal ash. However, the quality and quantity of discarded coal ash across the U.S. are not well known, even though this information is crucial for spurring its reuse for conventional and new material applications. This study describes a predictive model for the major element composition of coal ash in reserve at disposal sites of major U.S. coal-fired power plants. This model was constructed from coal purchase records of 705 power stations from 1973 to 2022 and was trained on coal ash composition data, showing that coal ash elemental composition is strongly associated with the source of feedstock coal. The model showed regional shifts in the major element contents of ash produced by power plants in the last 50 years, particularly for calcium and iron (expressed as %CaO and %Fe2O3), as power stations changed their source of coal over this time frame. Our approach enables an estimation of chemical composition for ash stored in waste impoundments at individual power stations. Such information can help to delineate the regional market resource potential of supplementary cements for concrete and other material innovations that would utilize coal ash harvested from disposal sites across the U.S.

01 COAL, LIGNITE, AND PEAT↗