Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Bubble chambers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Snowmass 2021 Scintillating Bubble Chambers: Liquid-noble Bubble Chambers for Dark Matter and CE$\nu$NS Detection

The Scintillating Bubble Chamber (SBC) Collaboration is developing liquid-noble bubble chambers for the quasi-background-free detection of low-mass (GeV-scale) dark matter and coherent scattering (CE$\nu$NS) of low-energy (MeV-scale) neutrinos. The first physics-scale demonstrator of this technique, a 10-kg liquid argon bubble chamber dubbed SBC-LAr10, is now being commissioned at Fermilab. This device will calibrate the background discrimination power and sensitivity of superheated argon to nuclear recoils at energies down to 100 eV. A second functionally-identical detector with a focus on radiopure construction is being built for SBC's first dark matter search at SNOLAB. The projected spin-independent sensitivity of this search is approximately $10^{-43}$ cm$^2$ at 1 GeV$/c^2$ dark matter particle mass. The scalability and background discrimination power of the liquid-noble bubble chamber make this technique a compelling candidate for future dark matter searches to the solar neutrino fog at 1 GeV$/c^2$ particle mass (requiring a $\sim$ton-year exposure with non-neutrino backgrounds sub-dominant to the solar CE$\nu$NS signal) and for high-statistics CE$\nu$NS studies at nuclear reactors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for inelastic dark matter-nucleus scattering with the PICO-60 CF$_{3}$I and C$_{3}$F$_{8}$ bubble chambers

PICO bubble chambers have exceptional sensitivity to inelastic dark matter-nucleus interactions due to a combination of their extended nuclear recoil energy detection window from a few keV to $O$(100 keV) or more and the use of iodine as a heavy target. Inelastic dark matter-nucleus scattering is interesting for studying the properties of dark matter, where many theoretical scenarios have been developed. This study reports the results of a search for dark matter inelastic scattering with the PICO-60 bubble chambers. The analysis reported here comprises physics runs from PICO-60 bubble chambers using CF$_{3}$I and C$_{3}$F$_{8}$. The CF$_{3}$I run consisted of 36.8 kg of CF$_{3}$I reaching an exposure of 3415 kg-day operating at thermodynamic thresholds between 7 and 20 keV. The C$_{3}$F$_{8}$ runs consisted of 52 kg of C$_{3}$F$_{8}$ reaching exposures of 1404 kg-day and 1167 kg-day running at thermodynamic thresholds of 2.45 keV and 3.29 keV, respectively. The analysis disfavors various scenarios, in a wide region of parameter space, that provide a feasible explanation of the signal observed by DAMA, assuming an inelastic interaction, considering that the PICO CF$_{3}$I bubble chamber used iodine as the target material.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A New Era for Modern Bubble Chamber Technology: Cooling and Real-Time Control for the MAMBA Neutrino Bubble Chamber∗

Future neutrino experiments such as DUNE will be limited less by statistics than by how well neutrino--nucleus interactions are understood, and the cleanest way to improve that understanding is to measure interactions with light nuclei such as hydrogen or deuterium. The detector best suited to the job, the bubble chamber, has not been built for a neutrino beam in about fifty years. MAMBA (Modern Adaptive Modular Bubble chamber Archetype) is a small prototype at Fermilab intended to bring the technology back with modern cryogenics and automation, cycling continuously at 1~Hz. This paper summarizes my work on two of its subsystems during a summer internship. A new solid copper thermal link brought the coldhead to 21.3~K in a commissioning cooldown, near the 20~K operating target. An Industrial Shields Raspberry Pi programmable logic controller (PLC) running OpenPLC was characterized at a median round-trip response of 0.64~ms over 20,000 trials, with 0.66\% of trials exceeding 1~ms. Both results support continuous cycling.

Williams, Nicholas [Fermilab; DuPage Coll.]↗

Batch VUV4 characterization for the SBC-LAr10 scintillating bubble chamber

The Scintillating Bubble Chamber (SBC) collaboration purchased 32 Hamamatsu VUV4 silicon photomultipliers (SiPMs) for use in SBC-LAr10, a bubble chamber containing 10 kg of liquid argon. A dark-count characterization technique, which avoids the use of a single-photon source, was used at two temperatures to measure the VUV4 SiPMs breakdown voltage (V BD ), the SiPM gain (g SiPM ), the rate of change of g SiPM with respect to voltage (m), the dark count rate (DCR), and the probability of a correlated avalanche (P CA ) as well as the temperature coefficients of these parameters. A Peltier-based chilled vacuum chamber was developed at Queen's University to cool down the Quads to 233.15 ± 0.2 K and 255.15 ± 0.2 K with average stability of ±20 mK. An analysis framework was developed to estimate V BD to tens of mV precision and DCR close to Poissonian error. The temperature dependence of V BD was found to be 56 ± 2 mV K -1 , and m on average across all Quads was found to be (459 ± 3(stat.)±23(sys.))× 10 3 e- PE -1 V -1 . The average DCR temperature coefficient was estimated to be 0.099 ± 0.008 K -1 corresponding to a reduction factor of 7 for every 20 K drop in temperature. The average temperature dependence of P CA was estimated to be 4000 ± 1000 ppm K -1 . P CA estimated from the average across all SiPMs is a better estimator than the P CA calculated from individual SiPMs, for all of the other parameters, the opposite is true. All the estimated parameters were measured to the precision required for SBC-LAr10, and the Quads will be used in conditions to optimize the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A direct test of Auger cascade induced nucleation from heavy element contamination in C 3 F 8 bubble chambers

Understanding and quantifying the gamma-induced bubble nucleation background in clean nuclear recoil detection bubble chambers is of utmost importance to bubble chamber based dark matter searches. Here, we present data confirming the hypothesis that large Auger cascades from high-Z elements such as iodine and xenon dramatically increase the response of C 3 F 8 bubble chambers to gamma rays. These tests, performed with a small calibration bubble chamber filled with C 3 F 8 +$\mathcal{O}$ (10) ppm xenon, show that the probability of bubble nucleation scales with the rate of xenon inner-shell vacancies, reaching values >10% per K-Shell vacancy for Seitz thresholds of interest to future dark matter searches in bubble chambers. We also place an upper limit on bubble nucleation probability for argon Auger events, relevant to large future bubble chambers which may contain some residual atmospheric argon after the active fluid fill.

47 OTHER INSTRUMENTATION↗

Scintillating Bubble Chambers for Rare Event Searches

The Scintillating Bubble Chamber (SBC) collaboration is developing liquid-noble bubble chambers to detect sub-keV nuclear recoils, allowing the search for low-mass (GeV-scale) dark matter and coherent elastic neutrino-nucleus scattering from low-energy (MeV-scale) neutrinos. The scintillating bubble chamber detectors benefit from the energy reconstruction that the scintillation signal gives in addition to the superior electron-recoil insensitivity that bubble chambers naturally provide. The high level of superheat achievable in noble liquids while being electron-recoil insensitive allows for lower nuclear recoil thresholds than in existing freon-based bubble chambers, potentially reaching the 100 eV threshold desired for reactor CEvNS measurements. To validate this lower threshold, the SBC collaboration is constructing two 10 kg detectors that are functionally identical. The SBC-LAr10, which is being commissioned at Fermilab, is intended for engineering and calibration research and has additional possibilities in assessing coherent elastic neutrino-nucleus scattering in argon. SBC-SNOLAB, the second detector for a low-background dark matter search, will be run at SNOLAB underground.

Pyda, Daniel [Unlisted, US]↗

Scintillating Bubble Chambers for Rare Event Searches

The Scintillating Bubble Chamber (SBC) collaboration is developing liquid-noble bubble chambers for the detection of sub-keV nuclear recoils. These detectors benefit from the electron recoil rejection inherent in moderately-superheated bubble chambers with the addition of energy reconstruction provided from the scintillation signal. The ability to measure low-energy nuclear recoils allows the search for GeV-scale dark matter and the measurement of coherent elastic neutrino-nucleus scattering on argon from MeV-scale reactor antineutrinos. The first physics-scale detector, SBC-LAr10, is in the commissioning phase at Fermilab, where extensive engineering and calibration studies will be performed. In parallel, a functionally identical low-background version, SBC-SNOLAB, is being built for a dark matter search underground at SNOLAB. SBC-SNOLAB, with a 10 kg-yr exposure, will have sensitivity to a dark matter–nucleon cross section of 2×10 –42 cm 2 at 1 GeV/c 2 dark matter mass, and future detectors could reach the boundary of the argon neutrino fog with a tonne-yr exposure. In addition, the deployment of an SBC detector at a nuclear reactor could enable neutrino physics investigations including measurements of the weak mixing angle and searches for sterile neutrinos, the neutrino magnetic moment, and the light Z’ gauge boson.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillating Bubble Chambers for Direct Dark Matter Detection, and an Update on SBC-LAr10

The Scintillating Bubble Chamber (SBC) Collaboration aims to use the liquid-noble bubble chamber technology as a low-threshold detector for dark matter particles of 1-10 GeV/c2. The detector combines the remarkable electron recoil (ER) discrimination of the bubble chamber with the event-by-event energy resolution provided by liquid argon (LAr) scintillation, with the crucial added benefit that ER discrimination in liquid-noble bubble chambers extends to much lower thresholds than in past freon-filled bubble chambers, with the potential for quasi-background-free operation at thresholds of 100 eV in nuclear recoil (NR) energy. SBC has developed two functionally identical 10 kg detectors: SBC-LAr10 at Fermilab will calibrate low-threshold performance, while the radio-pure SBC-SNOLAB chamber will execute SBC s first deep-underground dark matter search. SBC-LAr10 at Fermilab was recently installed in the MINOS tunnel 100 meters underground, and the first bubbles are expected this fall. I will present the current status of SBC-LAr10 and describe the suite of gamma and neutron calibrations we will execute. The calibrations will confirm the physics reach of this new technology, motivating not just the SBC-SNOLAB chamber now being assembled but also future searches into the solar neutrino fog at 1 GeV/c2.

Sheng, Zhiheng↗

Scintillating Bubble Chambers for Direct Dark Matter Detection, and an Update on SBC-LAr10

The Scintillating Bubble Chamber (SBC) Collaboration aims to use the liquid-noble bubble chamber technology as a low-threshold detector for dark matter particles of 1-10 GeV/c2. The detector combines the remarkable electron recoil (ER) discrimination of the bubble chamber with the event-by-event energy resolution provided by liquid argon (LAr) scintillation, with the crucial added benefit that ER discrimination in liquid-noble bubble chambers extends to much lower thresholds than in past freon-filled bubble chambers, with the potential for quasi-background-free operation at thresholds of 100 eV in nuclear recoil (NR) energy. SBC has developed two functionally identical 10 kg detectors: SBC-LAr10 at Fermilab will calibrate low-threshold performance, while the radio-pure SBC-SNOLAB chamber will execute SBC s first deep-underground dark matter search. SBC-LAr10 at Fermilab was recently installed in the MINOS tunnel 100 meters underground, and the first bubbles are expected this fall. I will present the current status of SBC-LAr10 and describe the suite of gamma and neutron calibrations we will execute. The calibrations will confirm the physics reach of this new technology, motivating not just the SBC-SNOLAB chamber now being assembled but also future searches into the solar neutrino fog at 1 GeV/c2.

Sheng, Zhiheng↗

A Scintillating Xenon Bubble Chamber for Dark Matter Detection. Final Report

This report describes the progress in the search for particle dark matter achieved under DOE award DE-SC0012161, as well as the invention of a new dark matter and neutrino detection technique. Work supported by this award follows in three distinct thrusts: (1) the successful completion of the Generation-1 Direct Detection experiment PICO-60, which set the world-leading limit on the spin-dependent coupling of dark matter to protons and achieved a precise understanding of the response of bubble chambers to nuclear-recoil signals and electron-recoil backgrounds; (2) the construction of the Generation-2 Direct Detection experiment LZ, which will soon be the world's most sensitive dark matter detector; and (3) the demonstration of the first scintillating bubble chamber. The development of a scintillating liquid noble bubble chamber was the primary goal of the proposed work, with the aim of combining the excellent background rejection of a PICO-style bubble chamber with the event-by-event energy resolution of a liquid-noble detector such as LZ. This work produced the first ever observation of coincident scintillation and bubble nucleation by a nuclear recoil in a superheated fluid and also revealed an unexpected benefit to the use of noble liquids in a bubble chamber, namely the ability to increase the degree of superheat by an order of magnitude beyond that achievable in PICO-style detectors while maintaining PICO's world-leading background rejection. This discovery has led to new projects in the US and Canada, developing noble liquid bubble chambers both as detectors for low-mass dark matter and as detectors of coherent elastic neutrino-nucleus scattering (CEvNS) by neutrinos produced at nuclear reactors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MAMBA: A Prototype Modern Modular Bubble Chamber for Precision Measurement of Neutrino Nucleus Cross Sections

High precision measurements of neutrino interactions are essential for the success of future neutrino oscillation experiments. Understanding the interaction rate and precise energy spectrum requires understanding of neutrino interactions and nuclear effects. Measuring interactions in a light nuclear target , such as Hydrogen or deuterium, would provide highly valuable input to reduce reduce the uncertainties associated with neutrino-nucleus cross sections, relevant for upcoming experiments like the Deep Underground Neutrino Experiment (DUNE) and Hyper-Kamiokande (Hyper-K). A bubble chamber presents an opportunity to study a light nuclear target using hydrogen in the liquid phase as a working fluid. However historical hydrogen bubble chamber designs if placed in modern neutrino beams would miss a significant fraction of the total number of available interactions. We present a bubble chamber prototype, MAMBA, which will be used to investigate strategies for inexpensively enabling continuous cycling through improved cooling at scale and expanding the active time of historic bubble chambers. MAMBA aims to demonstrate the feasibility of precision neutrino–nucleon measurements at conditions comparable to modern beams.

Martínez Casales, María [Fermilab] (ORCID:00000003↗

Low-threshold response of a scintillating xenon bubble chamber to nuclear and electronic recoils

A device filled with pure xenon first demonstrated the ability to operate simultaneously as a bubble chamber and scintillation detector in 2017. Initial results from data taken at thermodynamic thresholds down to ∼4 keV showed sensitivity to ∼20 keV nuclear recoils with no observable bubble nucleation by 𝛾-ray interactions. Here, this paper presents results from further operation of the same device at thermodynamic thresholds as low as 0.50 keV, hardware limited. The bubble chamber has now been shown to have sensitivity to ∼1 keV nuclear recoils while remaining insensitive to bubble nucleation by 𝛾-rays. A data-driven calibration of the chamber’s nuclear recoil nucleation response, as a function of nuclear recoil energy and thermodynamic state, is presented. Stringent upper limits are established for the probability of bubble nucleation by 𝛾-ray-induced Auger cascades, with a limit of <1.1 ×10 −6 set at 0.50 keV, the lowest thermodynamic threshold explored.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absorption of Fermionic Dark Matter in the PICO-60 C 3 F 8 Bubble Chamber

Fermionic dark matter absorption on nuclear targets via neutral current interactions is explored using a nonrelativistic effective field theory framework. An analysis of data from the PICO-60 C 3 ⁢F 8 bubble chamber sets leading constraints on spin-independent absorption for dark matter masses below 23 MeV/𝑐 2 and establishes the first limits on spin-dependent absorptive interactions. In conclusion, these results demonstrate the sensitivity of bubble chambers to low-mass dark matter and underscore the importance of absorption searches in expanding the parameter space of direct detection experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bubble Chamber Detectors with Light Nuclear Targets: A Snowmass 2021 White Paper

Neutrino cross sections are a critical ingredient in experiments that depend on neutrino scattering to reconstruct event kinematics and infer neutrino characteristics, like NOvA and T2K. An opportunity exists to reduce the 5-10% broad uncertainty on neutrino cross sections by producing more measurements of neutrino scattering from light nuclear targets at the relevant energies. Bubble chambers with light nuclear targets would be ideal for these measurements but the most recent device designed for use with an accelerator neutrino source is at least fifty years old. A new bubble chamber with light nuclear targets could be designed by observing how the technology has progressed for use in dark matter experiments and producing smaller modular devices that use more efficient cooling systems. A smaller modular device could also be designed for deployment to all functioning neutrino beams, but an investigation of the proper operating characteristics is necessary to adapt newer detectors to the structure of contemporary neutrino beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Era for Bubble Chamber Technology

Neutrino experiments like DUNE are limited by how well we understand the way neutrinos actually interact with atoms. The best way to fix that is to measure interactions on hydrogen, since a hydrogen nucleus is just a single free proton with largely none of the nuclear effects that heavier targets like argon have. The catch is that no one has built a hydrogen bubble chamber for a neutrino beam since the 1980s, mostly because the old chambers had too low of an active time. MAMBA is a project focused on bringing that technology back but built to cycle continuously at 1 Hz. I spent my summer internship on two of the subsystems that make that kind of speed possible. First, I helped install and test a new solid copper thermal link that replaced the old flexible braided cooling path, and it brought the coldhead down to 21.3 K, right at the target temperature. Second, I built and tested a Raspberry Pi based PLC control system, and across 20,000 trials it answered in a median of 0.64 ms, with only 0.66\% of trials running past 1 ms. Both results point the same direction: that inexpensive, off the shelf hardware can perform fast and reliable enough to eventually run a bubble chamber the way MAMBA needs it to run.

Williams, Nicholas [DuPage Coll.]↗

Measuring the cross section of the N 15 ( α , γ ) 19 F reaction using a single-fluid bubble chamber

15 N(α, γ) 19 F is believed to be the primary means of stellar nucleosynthesis of fluorine. Here we present the use of a single-fluid bubble chamber to measure the cross section of the time-inverse photo-dissociation reaction. The method benefits from a luminosity increase of several orders of magnitude due to the use of a thicker liquid target - compared to thin films or gas targets - and from the reciprocity theorem. We discuss the results of experiments at the Thomas Jefferson National Accelerator Facility, where the cross section of the photodisintegration process 19 F(γ, α) 15 N was measured by bombarding a superheated fluid of C 3 F 8 with bremsstrahlung γ rays produced by impinging a 4 - 5.5 MeV electron beam on a Cu radiator. From the photodissociation yield the cross section was extracted by performing a convolution with a Monte Carlo–generated γ-ray beam spectrum. The measurement produced a cross section that was then time inverted using the reciprocity theorem. The cross section for the 15 N(α, γ) 19 F reaction was determined down to a value in the range of hundreds of picobarns. We report that with further improvements of the experimental setup the technique could potentially push cross section measurements down to the single picobarn range.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Results on photon-mediated dark-matter–nucleus interactions from the PICO-60 C 3 F 8 bubble chamber

Many compelling models predict dark matter coupling to the electromagnetic current through higher multipole interactions, while remaining electrically neutral. Different multipole couplings have been studied, among them anapole moment, electric and magnetic dipole moments, and millicharge. This study sets limits on the couplings for these photon-mediated interactions using nonrelativistic contact operators in an effective field theory framework. Using data from the PICO-60 bubble chamber leading limits for dark matter masses between 2.7 and 24 GeV/c 2 and above 265 GeV/c 2 (anapole moment), 2.7 and 11.7 GeV/c 2 (electric moment), 3 and 9.5 GeV/c 2 (magnetic moment), and 2.7 and 12 GeV/c 2 (millicharged) are reported for the coupling of these photon-mediated dark matter-nucleus interactions. The detector was filled with 52 kg of C 3 F 8 operating at thermodynamic thresholds of 2.45 keV and 3.29 keV, reaching exposures of 1404 kg-day and 1167 kg-day, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗