Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “British”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

AmeriFlux FLUXNET-1F CA-Ca3 British Columbia - Pole sapling Douglas-fir stand

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site CA-Ca3 British Columbia - Pole sapling Douglas-fir stand. This is the FLUXNET version of the carbon flux data for the site CA-Ca3 British Columbia - Pole sapling Douglas-fir stand produced by applying the standard ONEFlux (1F) software. Site Description - Site: 1988 Harvested Douglas Fir (Pole-sapling); Tower Type 10" triangular tower; Latitude/Longitude 49.53462N -124.90044W (GPS survey, 2003. Coordinates updated/corrected May, 2006); Elevation approx. 170 m; Mean Air Temp. (for the growing season) 9.7 C *; Mean Annual Precipitation 1179 mm *; Date Operations Began: September 2001; Frequency of EC Measurements 20 Hz; Frequency of Other Met. Sensors 4 sec, year round; Soil Respiration Measurements Periodically during growing season using portable system in 2002; * 30-yr climate normals from the Comox Airport

Black, T. Andrew [University of British Columbia, ↗

RELAP5-3D British and SI Unit Conversion Task

The RELAP5-3D code uses conversion factors throughout the code to convert values between British and SI units. Conversion factors are typically in each of the separate routines that perform unit conversion. This results in inconsistent unit conversion and increases the likelihood of errors being introduced in the conversion factors. Unit conversion factors were relocated to a centralized module so that these values are only entered in one location. The unit conversion values were then replaced in the various locations with a unit conversion variable. The code was tested using the verification test set after making these changes and the results were analyzed. As expected, all the cases that use British input were found to have changed. In addition, three other cases changed due to changes in conversion factors.

97 MATHEMATICS AND COMPUTING↗

AmeriFlux FLUXNET-1F CA-LP1 British Columbia - Mountain pine beetle-attacked lodgepole pine stand

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site CA-LP1 British Columbia - Mountain pine beetle-attacked lodgepole pine stand . This is the FLUXNET version of the carbon flux data for the site CA-LP1 British Columbia - Mountain pine beetle-attacked lodgepole pine stand produced by applying the standard ONEFlux (1F) software. Site Description - This tower is located at an mountain pine beetle (MPB)-attacked almost pure lodgepole pine stand, 15 tall, approximately 35 km southeast of Mackenzie at Kennedy Siding .

Black, Thomas Andrew↗

AmeriFlux FLUXNET-1F CA-Ca1 British Columbia - 1949 Douglas-fir stand

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site CA-Ca1 British Columbia - 1949 Douglas-fir stand. This is the FLUXNET version of the carbon flux data for the site CA-Ca1 British Columbia - 1949 Douglas-fir stand produced by applying the standard ONEFlux (1F) software. Site Description - 1949 Douglas-fir stand; Tower Type 20" triangular tower; Latitude/Longitude 49.86725N 125.33360W (GPS survey, 2003. Coordinates updated/corrected May, 2006); Elevation 320 m; North-east facing terrain, 5-10 deg slope; Mean Air Temp. 8.3 °C* ; Mean Annual Precipitation 1461 mm * ; Date Operations Began June 1997 ; Frequency of EC Measurements 20.83 Hz; Frequency of Other Met. Sensors 1 - 4 sec, year round ; Soil Respiration Measurements 30 min., automated soil respiration system in 2000, periodically during growing season using portable system in 2002 ; * 1998-2001 averages from the 1948 Douglas-fir stand meteorological tower

Black, T. Andrew↗

AmeriFlux FLUXNET-1F CA-Ca2 British Columbia - Clearcut Douglas-fir stand (harvested winter 1999/2000)

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site CA-Ca2 British Columbia - Clearcut Douglas-fir stand (harvested winter 1999/2000). This is the FLUXNET version of the carbon flux data for the site CA-Ca2 British Columbia - Clearcut Douglas-fir stand (harvested winter 1999/2000) produced by applying the standard ONEFlux (1F) software. Site Description - Tower Type: 10" triangular tower; Latitude/Longitude 49.87048N -125.29087W (GPS survey, 2003. Coordinates updated/corrected May, 2006); Elevation approx. 180m; Mean Air Temp. (for the growing season) 8.3 C*; Mean Annual Precipitation 1461 mm *; Date Operations Began August 2000; Frequency of EC Measurements 7.7 Hz (2000 ­ 2001), 20 Hz (2002); Frequency of Other Met. Sensors 4 sec, year round; Soil Respiration Measurements Periodically during growing season using portable system in 2002; * 1998-2001 averages from the 1948 Douglas-fir stand meteorological tower

Black, T. Andrew↗

Informed Multi‐Scale Approach Applied to the British Columbia Fires of Late Summer 2017

Abstract Pyrocumulonimbus (PyroCb) clouds have a complex origin dependent on fire dynamics and meteorological conditions. When a pyrocumulonimbus cloud develops and is maintained over a period of time, it can inject significant aerosol into the troposphere and lower stratosphere, resulting in a longer‐term (months to years) occurrence of aerosol in the stratosphere. In this work, we investigate the British Columbia wildfires on 12–13 August 2017 using a multi‐scale simulation framework. We use the output of a physics‐based wildfire model (FIRETEC) with parameterized energy, particle, and gas emissions to drive the upper atmospheric aerosol mass injection within a regional cloud resolving model (HIGRAD). We demonstrate that vertical motions produced by latent heat release of the condensation of ice and cloud particles within the PyroCbs induce another 5 km of lifting of the simulated aerosol plume. Primary black carbon and organic aerosols (OAs) alone may not be enough to explain the observed aerosol burden, thus we show that secondary OA produced via condensation of gases by the fires, ash, and possibly dust can enhance lofted aerosol mass. A simulation with all emission mechanisms active, driven by the observed fuel load and environmental conditions, reasonably reproduces an aerosol profile inferred from observational data.

54 ENVIRONMENTAL SCIENCES↗

Pyrocumulonimbus Events Over British Columbia in 2017: An Ensemble Model Study of Parameter Sensitivities and Climate Impacts of Wildfire Smoke in the Stratosphere

Abstract The Pyrocumulonimbus (pyroCb) events over British Columbia in 2017 were observed in the lower stratosphere for about 8–10 months after the smoke injections. Several previous studies used global climate models to investigate the physical parameters for the 2017 pyroCb events, but the conclusions show strong model dependency. In this study, we use the Energy Exascale Earth System Model (E3SM) and complete an ensemble of runs exploring three injection parameters: smoke aerosol mass, the percentage of black carbon within the smoke aerosols, and plume injection height. Additionally, we consider the heterogeneous reaction of ozone and primary organic matter. According to the satellite daily observed aerosol optical depth (AOD), we find that the best ensemble member is the simulation with 0.4 Tg of smoke, 3% of which is black carbon, a 13.5 km smoke injection height, and a 10 −5 probability factor of the heterogeneous reaction. Besides AOD, we examine the ensemble score based on the metrics used in previous studies: the metrics of the extinction coefficient at 18 km altitude and the maximum plume height. The conclusion of the best estimate of the injection parameters for 2017 pyroCb events shows strong not only model but also evaluation metric dependency. We use the Random Forest machine learning technique to quantify the relative importance of each parameter in accurately simulating the 2017 pyroCb events and find that the injection height is the most critical feature, no matter which metric is used to score the ensemble members.

54 ENVIRONMENTAL SCIENCES↗

The avoidance of unwanted catch and cooperation: the case of the British Columbia groundfish trawl fishery

Abstract This paper focuses on a particularly successful avoidance of unwanted catch of protected, endangered, and threatened (PET) species in the form of ecologically important sponge and coral, to be found off Canada's Pacific coast. The fishery causing the unwanted catch—the British Columbia groundfish trawl fishery. A campaign to protect the sponge/coral led by environmental NGOs (ENGOs) resulted in the industry's access to the key California market being threatened. For reasons explained, the national resource manager's ability to take effective direct action had become severely compromised. The groundfish trawl fishing industry responded to the economic threat with a bottom up approach to the unwanted catch problem, by negotiating a habitat agreement with a consortium of ENGOs, with the blessing and full support of the national resource manager. The agreement, now in its tenth year of operation, has proved to be a remarkable success in avoidance of unwanted catch. The paper argues that the success rests fundamentally upon the fact that the fishers have been and are playing a stand alone stable cooperative game, which has led them in turn to play stable cooperative games with both the national resource manager and the ENGO consortium. The paper analyses the factors leading to the stand alone stable cooperative fisher game, doing so by necessity through the lens of game theory.

Grønbæk, L.↗

A Partnership between countries that endures today. The British Mission was a part of the Lab from 1943-1945

After 27 months of grueling hours and scientific secrecy amidst the pressure of a mounting death toll and Nazi Germany's own weapons development, it had come to an end. It was time to celebrate. On September 22, 1945, scientists, engineers and their families gathered at Fuller Lodge downtown to celebrate the success of the Los Alamos atomic bomb and the end of World War II. The party was hosted by members of the British Mission and their wives and included food, dancing and a satirical play based on the lighter moments of wartime life in Los Alamos. However, this party was more than just entertainment and a night of festivities, it also represented a partnership between countries that endures today.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Global lessons: a comparative analysis of nuclear gamification's impact in American and British students

The global nuclear skills shortage demands urgent educational investment, particularly for students aged 11–18. To help address this, we have introduced RAD Ratings, an interactive card game designed to improve the teaching of nuclear concepts to students, which includes subjects such as half-lives, types of radiation, and radionuclide applications. RAD Ratings has already been successfully piloted in the United Kingdom and in this paper, we present a comparison in selected American schools for the first time. Snapshot survey results show RAD Ratings improve interest in nuclear science and careers, offering insights into gamification’s potential to improve engagement across different geographic locations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

LANL PVC bag-out-bag replacement [Slides]

The US material at 8 months aging, at room temperature and exposed to gamma at 80 degrees C has been completed. The FTIR data does not show any discernible difference between the US APU-ether material and the British material. There are some differences and the curves of the FTIR, but the behavior shows that the US material is behaving comparable to the British material. The British Blue sample exposed to gamma at 70 degrees C did have an observable change in the contact angle. This was the only notable change between the two different types of polymer the TGA on both the US and the British had no observable difference. Mechanical testing samples (dog-bones) are being prepared for tensile, shear, and puncture testing. This data will be provided in later meetings. Mass spec testing is needed to measure the headspace gases that are being seen during the aging study to better health characterize the radiolytic degradation of the APU ether samples, this is also ongoing.

36 MATERIALS SCIENCE↗

Genetic Identification of Lamprey Genera and Anadromous Ecotypes in Watersheds of the Northeastern Pacific Ocean

ABSTRACT Nonparasitic, nonmigratory Western Brook Lamprey (WBL; Lampetra ayresii ), and parasitic, anadromous Western River Lamprey (WRL; L. ayresii ) are sympatric lampreys that likely represent different life history variations of a single species. Novel genetic tools are critical for differentiating WBL and WRL, whose larvae preclude morphological identification (ID) and will enable comprehensive assessment of imperiled native lampreys of the Northeastern Pacific (including WBL, WRL, and Pacific Lamprey, Entosphenus tridentatus ). We developed 47 candidate single nucleotide polymorphism (SNP) markers using whole genome resequencing of WBL ( N = 24) and WRL ( N = 15) from Ksi Ts'oohl Ts'ap Creek (Nass River, British Columbia, Canada) which are likely ecotypes distinguished by few divergent SNPs across multiple chromosomes. We used five novel candidate SNPs to perform genetic ID of WBL and WRL ecotypes in collections of mixed native lampreys from lower Columbia River tributaries ( N = 1474), Ksi Ts'oohl Ts'ap Creek ( N = 352), and ocean phase WRL from the Georgia Basin (Salish Sea, British Columbia, Canada; N = 91). Two previously published SNPs were used to ID genera, Entosphenus versus Lampetra . Morphological ID utilized photographs collected from a subset of genotyped lampreys, and high concordance was demonstrated between ID methods for genera (99%) and Lampetra ecotypes (> 98%). We characterized spatial and temporal composition of lamprey genera and ecotypes surveyed across NE Pacific tributaries under the expectation these compositions would be similar across nearby sites and across years at the same site. Proportions of lamprey genera were highly variable within regions and across years; however, Lampetra ecotypic proportions were spatially and temporally stable. WRL were rare in lower Columbia tributaries (~1% average rate among Lampetra ) and common further north (> 40% of Lampetra ). Genetic ID methods are powerful monitoring tools that create the novel ability to ascertain genera and ecotypes regardless of life stage, while increasing the efficiency of surveys by eliminating time‐intensive morphological data collection.

Silver, G. S. [Columbia River Inter‐Tribal Fish Co↗

Regional and Temporal Variability of Atmospheric River Seasonality: Influences of Detection Algorithms and Moisture Transport Dynamics

Abstract Understanding the regional and temporal variability of atmospheric river (AR) seasonality is crucial for preparedness and mitigation of extreme events. While ARs were thought to peak in winter, recent research shows they exhibit region‐specific seasonality and are heavily influenced by the chosen detection algorithm. This study examines the link between the year‐to‐year consistency of peak‐AR activity to the presence of a dominant seasonal pattern, considering both location and algorithm choice. Regions are categorized by their temporal characteristics: consistent patterns (e.g., East Asia), patterns with occasional outliers (e.g., British Columbia coast), and regions lacking a clear dominant peak season (e.g., South Atlantic, parts of Australia). Hence, not all regions display a consistent seasonal cycle of AR activity. This study quantifies the extent to which a region experiences a dominant peak season of AR activity (or lacks one) and offers insights to enhance decision‐making in water management, natural hazard preparedness, and forecasting. Furthermore, given our finding that detection algorithms influence the peak season of AR activity, we also examine two diagnostic variables representative of moisture transport to corroborate our results. Integrated vapor transport, which captures meridional and zonal moisture transport, and Moist Wave Activity, representing moisture intrusions from lower to higher latitudes, are examined. Our analysis indicates that inconsistencies in the seasonal cycle of AR activity are not solely due to discrepancies in detection algorithms but also arise from changes in moisture transport. Plain Language Summary Atmospheric rivers (ARs) are critical weather phenomena that can cause extreme events like heavy rainfall and flooding. Understanding when and where ARs are most likely to occur throughout the year is essential for preparing and responding to these events. Traditionally, ARs were thought to peak in winter, but recent studies show this varies by region. Our study helps address the challenge decision‐makers face in anticipating and preparing for AR events by providing insights into the consistency of peak seasonal patterns across different areas. Some regions, like East Asia, and the British Columbia coast, show a consistent peak season, while others, like the South Atlantic and parts of Australia, have significant year‐to‐year variations, making it hard to identify a dominant season. To better understand these changes over time, the study also examines how moisture moves in the atmosphere, using Integrated Vapor Transport (which looks at moisture movement in various directions) and Moist Wave Activity (which tracks moisture shifts from lower to higher latitudes). The findings suggest that inconsistencies in AR patterns are due not only to detection methods but also due to changes in moisture transport. Key Points The peak season of atmospheric river activity can change depending on the year in some areas Interannual variations in the peak season can make identifying a dominant season challenging for some regions Frequent shifts in peak season across years reflect inconsistencies tied to detection algorithms and to underlying dynamics

Kamnani, Diya↗

New K-feldspar Pb isotope results for Mesozoic arc crust in the Pacific Northwest, U.S.A. and Canada: comparison with the Mojave-Salinia province of southern California and Implications for Baja-BC

Measurements of lead isotopic compositions in detrital K-feldspar have been increasingly used as a tool to assess sediment provenance. We compiled a database of previously published Pb isotope data from 700 bedrock K-feldspar samples and 1,423 age-corrected bedrock whole rock samples from western North American igneous and metamorphic bodies. Additionally, we report 66 new K-feldspar Pb isotope data for plutons throughout the Pacific Northwest region of the United States and British Columbia. Results show that the Pb isotope values of plutonic K-feldspar depend on the isotopically juvenile or evolved nature of underlying crust. Samples obtained from the mid Cretaceous – mid Eocene Coast Plutonic Complex, North Cascades, and Intermontane superterrane that occur west of the initial 87 Sr/ 86 Sr (Sri) = 0.706 isopleth exhibit a highly restricted 207 Pb/ 206 Pb and 208 Pb/ 206 Pb values centred upon 0.83 and 2.03, respectively. Conversely, rocks overlying older continental crust further east such as the Middle Jurassic – Late Cretaceous Omineca crystalline belt, Idaho batholith, and Boulder Batholith exhibit far greater variation of Pb isotope values that parallel the 100 Ma isochron calculated from a two-stage Pb evolution model. We demonstrate that Pb isotopic results from the Idaho and Boulder Batholith region can be used to define distinctive subregions for Pb isotopic provenance analysis, and compare these signatures to the Mojave-Salinian batholith of southern California and western Arizona, as these two areas have previously been proposed as source regions for extraregional sediment that was deposited within the Nanaimo Basin during the Campanian – Maastrichtian. Future Pb isotopic analysis of detrital K-feldspar from the Nanaimo Basin of southwestern British Columbia may effectively distinguish between potential extraregional sources separated by thousands of kilometres.

Coast Plutonic Complex↗

Woolwich, Bruceton, Los Alamos: Munroe Jets and the Trinity Gadget

Prewar work on the hydrodynamics of explosives and U.S./UK scientific cooperation well beyond Los Alamos contributed to the design of the explosive lenses for the Trinity gadget. Researchers were deliberately brought together and encouraged to share ideas by the leaders of the wartime laboratory. James Tuck, one of the British mission scientists, made particularly interesting contributions in this area, but this paper is not a claim of British or any other individual parentage. Rather, it highlights the importance of collaboration at Los Alamos and more widely.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Genotype–environment associations across spatial scales reveal the importance of putative adaptive genetic variation in divergence

Abstract Identifying areas of high evolutionary potential is a judicious strategy for developing conservation priorities in the face of environmental change. For wide‐ranging species occupying heterogeneous environments, the evolutionary forces that shape distinct populations can vary spatially. Here, we investigate patterns of genomic variation and genotype–environment associations in the hermit thrush ( Catharus guttatus ), a North American songbird, at broad (across the breeding range) and narrow spatial scales (at a hybrid zone). We begin by building a genoscape or map of genetic variation across the breeding range and find five distinct genetic clusters within the species, with the greatest variation occurring in the western portion of the range. Genotype–environment association analyses indicate higher allelic turnover in the west than in the east, with measures of temperature surfacing as key predictors of putative adaptive genomic variation rangewide. Since broad patterns detected across a species' range represent the aggregate of many locally adapted populations, we investigate whether our broadscale analysis is consistent with a finer scale analysis. We find that top rangewide temperature‐associated loci vary in their clinal patterns (e.g., steep clines vs. fixed allele frequencies) across a hybrid zone in British Columbia, suggesting that the environmental predictors and the associated candidate loci identified in the rangewide analysis are of variable importance in this particular region. However, two candidate loci exhibit strong concordance with the temperature gradient in British Columbia, suggesting a potential role for temperature‐related barriers to gene flow and/or temperature‐driven ecological selection in maintaining putative local adaptation. This study demonstrates how patterns identified at the broad (macrogeographic) scale can be validated by investigating genotype–environment correlations at the local (microgeographic) scale. Furthermore, our results highlight the importance of considering the spatial distribution of putative adaptive variation when assessing population‐level sensitivity to climate change and other stressors.

59 BASIC BIOLOGICAL SCIENCES↗

The Pacific Northwest Heat Wave of 25–30 June 2021: Synoptic/Mesoscale Conditions and Climate Perspective

Abstract An unprecedented heat wave occurred over the Pacific Northwest and southwest Canada on 25–30 June 2021, resulting in all-time temperature records that greatly exceeded previous record maximum temperatures. The impacts were substantial, including several hundred deaths, thousands of hospitalizations, a major wildfire in Lytton, British Columbia, Canada, and severe damage to regional vegetation. Several factors came together to produce this extreme event: a record-breaking midtropospheric ridge over British Columbia in the optimal location, record-breaking midtropospheric temperatures, strong subsidence in the lower atmosphere, low-level easterly flow that produced downslope warming on regional terrain and the removal of cooler marine air, an approaching low-level trough that enhanced downslope flow, the occurrence at a time of maximum insolation, and drier-than-normal soil moisture. It is shown that all-time-record temperatures have not become more frequent and that annual high temperatures only increased at the rate of baseline global warming. Although anthropogenic warming may have contributed as much as 1°C to the event, there is little evidence of further amplification from increasing greenhouse gases. Weather forecasts were excellent for this event, with highly accurate predictions of the extreme temperatures. Significance Statement This paper describes the atmospheric evolution that produced an extreme heat wave over the Pacific Northwest during June 2021 and puts this event into historical perspective.

Meteorology & Atmospheric Sciences↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗