Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Breath Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Versatile & Intelligent Biodetection via Environmental Sensing (VIBES)

Reactive health monitoring strategies during events like the COVID-19 pandemic highlighted the need for predictive, threat-agnostic diagnostics that can detect both known diseases and novel chemical or biological threats. To address this, we investigated an optical biosensor as a breath volatile organic compound (VOC) analyzer, aiming to emulate biological olfaction. We assembled and validated the device with thin film metal coated substrate-based sensors. We immobilized small biological recognition elements on the substrates and delivered controlled concentrations of target VOCs. The sensor was irradiated with a visible laser and the sensor signal was recorded. We characterized the laser performance and tested 3 recognition elements for 2 VOCs with varying concentrations (1-100 ppm). We also evaluated enhancement of the signal using nanostructures on the metal film in comparison with planar film substrate. We demonstrated detecting ethanol reliably at concentrations as low as ~2 ppm along with preliminary detection of acetone (<100 ppm). We also found several unexpected factors that influence the sensor behavior that should be addressed to further refine the device’s performance. The nanostructures were, as expected, found to amplify the sensor signals. These findings demonstrate the feasibility of the optical bio-sensing modality for breath VOC monitoring at physiologically relevant levels. This positions LLNL to develop a low-cost, scalable, broad-spectrum health monitoring capability aligned with the Early Detection thrust of the Bioresilience Mission Focus Area and attract external funding.

47 OTHER INSTRUMENTATION

Electronic Trap-State Modulation in Sm-Doped SnO 2 Nanofibers Enables Ultrasensitive Hydrogen Sensing

The demand for sub-ppm hydrogen (H 2 ) sensing is growing across emerging applications such as environmental monitoring, breath-based disease diagnostics, and early-stage battery failure detection. However, achieving reliable ppb-level detection with chemiresistive metal oxide sensors remains challenging. At trace gas concentrations, resistance modulation is often insufficient, particularly in the absence of noble metal catalysts. Here, we report samarium-doped tin dioxide (Sm-SnO 2 ) nanofibers in which electronic trap-state modulation is exploited to enable ultrasensitive hydrogen sensing. The 2 at% Sm-doped SnO 2 nanofibers exhibited markedly enhanced H 2 sensitivity, achieving clear detection down to 25 ppb H 2 at 200 °C, with a theoretical limit of detection of 4.5 ppb, placing this material among the most sensitive noble-metal-free SnO 2 -based H 2 sensors reported to date. Mechanistic investigations through X-ray photoelectron spectroscopy and electron energy loss spectroscopy revealed that Sm 3+ doping introduces deep trap states associated with charge-compensating defect complexes. These states reduce free carrier density, increase baseline resistance, and enable trap-assisted charge release during H 2 exposure, thereby amplifying the sensing response. Trap-state engineering via rare-earth doping, exemplified by Sm-SnO 2 , provides an effective pathway for achieving ppb-level hydrogen detection in noble-metal-free chemiresistive sensors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Skin CO 2 sniffing for wearable metabolic monitoring

CO 2 is a key physiological parameter used to assess hypoventilation and to estimate metabolic rates. However, current CO 2 monitoring relies on bulky breath-analysis systems that are impractical for continuous use in daily life. Here, we present a wearable on-skin gas-sniffing system that quantifies skin-emitted CO 2 and establishes its physiological relevance through direct correlation with exhaled CO 2 and metabolic rate. Participant studies demonstrate strong correlations between CO 2 flow rates from the skin and breath during both rest and exercise, with skin-emitted CO 2 approximately four orders of magnitude lower than exhaled CO 2 . Skin-emitted CO 2 also correlates with metabolic rate, suggesting its potential as a surrogate for breath-based indirect calorimetry. With its wearable form factor and physiological relevance, this skin gas sniffing system enables continuous, noninvasive metabolic monitoring and opens opportunities for studying skin gas exchange.

Kim, Seung-Rok [University of California, Berkeley

A comprehensive framework to assess elemental mercury in the Department of Energy: A descriptive analysis

Objective: This study investigated the relationship between personal breathing zone air samples and associated biological monitoring urine samples collected in the U.S. Department of Energy Operations. Methods: We performed standard descriptive analyses of the air sample and BEI monitoring data. We also provide a list of direct-reading instruments used in mercury field assessments. Results: A total of 2,330 air samples and 265 BEI data were analyzed. These data were grouped into 16 job titles, excluding categories with fewer than 10 samples, which resulted in 11 job titles. Conclusions: We conclude that industrial hygiene airborne sample data alone may not provide a complete assessment in exposure determination. We suggested the necessity of incorporating biological monitoring to determine the exposure.

60 APPLIED LIFE SCIENCES