TECHNO-ECONOMIC COMPARISON OF SOLAR-DRIVEN SCO2 BRAYTON CYCLES USING COMPONENT COST MODELS BASELINED WITH VENDOR DATA AND ESTIMATES.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Significant progress has been made in the ongoing development of the Argonne National Laboratory (ANL) Plant Dynamics Code (PDC), the ongoing investigation and development of control strategies, and the analysis of system transient behavior for supercritical carbon dioxide (S-CO 2 ) Brayton cycles. Several code modifications have been introduced during FY2011 to extend the range of applicability of the PDC and to improve its calculational stability and speed. A new and innovative approach was developed to couple the Plant Dynamics Code for S-CO 2 cycle calculations with SAS4A/SASSYS-1 Liquid Metal Reactor Code System calculations for the transient system level behavior on the reactor side of a Sodium-Cooled Fast Reactor (SFR) or Lead-Cooled Fast Reactor (LFR). The new code system allows use of the full capabilities of both codes such that whole-plant transients can now be simulated without additional user interaction. Several other code modifications, including the introduction of compressor surge control, a new approach for determining the solution time step for efficient computational speed, an updated treatment of S-CO 2 cycle flow mergers and splits, a modified enthalpy equation to improve the treatment of negative flow, and a revised solution of the reactor heat exchanger (RHX) equations coupling the S-CO 2 cycle to the reactor, were introduced to the PDC in FY2011. All of these modifications have improved the code computational stability and computational speed, while not significantly affecting the results of transient calculations. The improved PDC was used to continue the investigation of S-CO 2 cycle control and transient behavior. The coupled PDC-SAS4A/SASSYS-1 code capability was used to study the dynamic characteristics of a S-CO 2 cycle coupled to a SFR plant. Cycle control was investigated in terms of the ability of the cycle to respond to a linear reduction in the electrical grid demand from 100% to 0% at a rate of 5%/minute. It was determined that utilization of turbine throttling control below 50% load improves the cycle efficiency significantly. Consequently, the cycle control strategy has been updated to include turbine throttle valve control. The new control strategy still relies on inventory control in the 50%-90% load range and turbine bypass for fine and fast generator output adjustments, but it now also includes turbine throttling control in the 0%-50% load range. In an attempt to investigate the feasibility of using the S-CO 2 cycle for normal decay heat removal from the reactor, the cycle control study was extended beyond the investigation of normal load following. It was shown that such operation is possible with the extension of the inventory and the turbine throttling controls. However, the cycle operation in this range is calculated to be so inefficient that energy would need to be supplied from the electrical grid assuming that the generator could be capable of being operated in a motoring mode with an input electrical energy from the grid having a magnitude of about 20% of the nominal plant output electrical power level in order to maintain circulation of the CO 2 in the cycle. The work on investigation of cycle operation at low power level will be continued in the future. In addition to the cycle control study, the coupled PDC-SAS4A/SASSYS-1 code system was also used to simulate thermal transients in the sodium-to-CO 2 heat exchanger. Several possible conditions with the potential to introduce significant changes to the heat exchanger temperatures were identified and simulated. The conditions range from reactor scram and primary sodium pump failure or intermediate sodium pump failure on the reactor side to pipe breaks and valve malfunctions on the S-CO 2 side. It was found that the maximum possible rate of the heat exchanger wall temperature change for the particular heat exchanger design assumed is limited to ±7 C/s for less than 10 seconds. Modeling in the Plant Dynamics Code has been compared with available data from the Sandia National Laboratories (SNL) small-scale S-CO 2 Brayton cycle demonstration that is being assembled in a phased approach currently at Barber-Nichols Inc. and at SNL in the future. The available data was obtained with an earlier configuration of the S-CO 2 loop involving only a single-turbo-alternator-compressor (TAC) instead of two TACs, a single low temperature recuperator (LTR) instead of both a LTR and a high temperature recuperator (HTR), and fewer than the later to be installed full set of electric heaters. Due to the absence of the full heating capability as well as the lack of a high temperature recuperator providing additional recuperation, the temperature conditions obtained with the loop are too low for the loop conditions to be prototypical of the S-CO 2 cycle.
The supercritical carbon-dioxide (referred to as SC-CO 2 hereon) Brayton cycle is being considered for power conversion systems for a number of nuclear reactor concepts, including the sodium fast reactor (SFR), fluoride saltcooled high temperature reactor (FHR), and high temperature gas reactor (HTGR), and several types of small modular reactors (SMR). The SC-CO 2 direct cycle gas fast reactor has also been recently proposed. The SC-CO 2 Brayton cycle (discussed in Chapter 1) provides higher efficiencies compared to the Rankine steam cycle due to less compression work stemming from higher SC-CO 2 densities, and allows for smaller components size, fewer components, and simpler cycle layout. For example, in the case of a SFR using a SC-CO 2 Brayton cycle instead of a steam cycle would also eliminate the possibility of sodium-water interactions. The SC-CO 2 cycle has a higher efficiency than the helium Brayton cycle, with the additional advantage of being able to operate at lower temperatures and higher pressures. In general, the SC-CO 2 Brayton cycle is well-suited for any type of nuclear reactor (including SMR) with core outlet temperature above ~ 500°C in either direct or indirect versions. In all the above applications, materials corrosion in high temperature SC-CO 2 is an important consideration, given their expected lifetimes of 20 years or longer. Our discussions with National Laboratories and private industry early on in this project indicated materials corrosion to be one of the significant gaps in the implementation of SC-CO 2 Brayton cycle. Corrosion can lead to a loss of effective load-bearing wall thickness of a component and can potentially lead to the generation of oxide particulate debris which can lead to three-body wear in turbomachinery components. Another environmental degradation effect that is rather unique to CO 2 environment is the possibility for simultaneous occurrence of carburization during oxidation of the material. Carburization can potentially lead to embrittlement of structural alloys in SC-CO 2 Brayton cycle. An important consideration in regards to corrosion is that the temperatures can vary widely across the various sections of the SC-CO 2 Brayton cycle, from room temperature to 750°C, with even higher temperatures being desirable for higher efficiencies. Thus the extent of corrosion and corrosion mechanisms in various components and SC-CO 2 Brayton cycle will be different, requiring a judicious selection of materials for different sections of the cycle. The goal of this project was to address materials corrosion-related challenges, identify appropriate materials, and advance the body of scientific knowledge in the area of high temperature SC-CO 2 corrosion. The focus was on corrosion of materials in SC-CO 2 environment in the temperature range of 450°C to 750°C at a pressure of 2900 psi for exposure duration for up to 1000 hours. The Table below lists the materials tested in the project. The materials were selected based on their high temperature strength, their code certification status, commercial availabilities, and their prior or current usage in the nuclear reactor industry. Additionally, pure Fe, Fe-12%Cr, and Ni-22%Cr were investigated as simple model materials to more clearly understand corrosion mechanisms. This first phase of the project involved testing in research grade SC-CO 2 (99.999% purity). Specially designed autoclaves with high fidelity temperature, pressure, and flow control capabilities were built or modified for this project.
The transcritical carbon dioxide Rankine cycle has emerged as an alternative for power generation in low-grade heat applications. However, the low heat rejection temperatures required for condensing the carbon dioxide is almost prohibitive for many locations. A simple solution is the adoption of a supercritical carbon dioxide Brayton cycle which does not need such low temperature heat sinks. This power cycle has been poorly studied previously in low-grade heat applications. Therefore, with the aim of determining the performance and feasibility of the supercritical carbon dioxide Brayton cycle from thermodynamic viewpoint, using a low-grade geothermal heat source, this paper presents a comparative thermodynamic analysis between four different supercritical carbon dioxide Brayton cycles. For this purpose, detailed models were developed and solved by coupling the thermodynamic model with the thermal-hydraulic model of a Printed Circuit Heat Exchanger. Subsequently, simulations of a base case, a parametric analysis, and an optimization using Genetic Algorithms, were carried out. Results show that there is a combination of operating conditions that maximizes the electrical output of the system. Besides, some values of the minimum pressure of the cycles can increase substantially the precooler cooling water pumping power. At the optimum design point, using a 20 kg/s geothermal brine stream at 150 °C as heat source with a minimum allowable reinjection temperature of 70 °C, the Intercooled Recuperated Brayton Cycle achieved the highest electric power output, energy and exergy efficiencies, obtaining values of 779.99 kW, 11.51%, and 52.49%, respectively. The other feasible alternatives were the Recuperated Brayton Cycle, the Simple Brayton Cycle and the Intercooled Brayton Cycle, ranked, in that order.
Power cycle choices are determined by markets and available technologies. Two changes are occurring in the electricity sector. First, the world is beginning to move away from fossil fuels because of concerns about climate change. What replaces fossil fuels for variable electricity production? Second, there have been extraordinary technological advances in gas turbine technology. The changes in market requirements and technology suggest the need to reexamine nuclear power cycles. One option is to couple high-temperature base-load nuclear reactors to closed Brayton cycles (helium, nitrogen, etc.) with Firebrick Resistance-Heated Energy Storage (FIRES). The reactor operates at base-load but not the power cycle. When electricity prices are low, firebrick is electrically heated to high temperatures using base-load electricity and/or electricity from the grid. The gas turbine can use nuclear heat for base-load operation and produce added peak electricity by sending the compressed heated gas through hot firebrick after nuclear heating to further raise power cycle gas temperatures and power output from the turbine-creating a nuclear plant with a thermodynamic topping (NUTOP) cycle. If such cycles can be developed, they would increase plant revenue and enable a low-carbon electricity grid. Such cycles can be coupled to Fluoride-salt-cooled High-temperature Reactors (FHRs), molten salt reactors (MSRs), high-temperature gas-cooled reactors (HTGRs), sodium-cooled fast reactors (SFRs) and lead-cooled fast reactors (LFRs). We discuss (1) market changes, (2) previous work on Nuclear Air-Brayton Combined cycles (NACC) with base-load reactors and variable power to the electricity grid and (3) options for closed Brayton cycles with variable power while the reactor operates at base load. Market (customer) requirements ultimately drive selection of power cycles. A low-carbon electricity grid requires dispatchable nuclear electricity to replace the traditional role of fossil fuels in the electricity grid. While reactors can be operated at part load, this is expensive for a capital-intensive low-operating-cost technology. Brayton power cycles with FIRES have the potential capability to provide that variable electricity while the reactor operates at base load to (1) improve economics and (2) enable a zero-carbon electrical grid. Open Brayton cycles have been investigated. Work has now started on developing closed Brayton cycles with FIRES. Only limited work has been done to date has been done for closed cycles with FIRES. (authors)
Generation IV high temperature reactor systems use closed gas Brayton Cycles to realize high thermal efficiency in the range of 40% to 60%. The waste heat is removed through coolers by water at substantially greater average temperature than in conventional Rankine steam cycles. This paper introduces an innovative Advanced Multi-Effect Distillation (AMED) design that can enable the production of substantial quantities of low-cost desalinated water using waste heat from closed gas Brayton cycles. A reference AMED design configuration, optimization models, and simplified economics analysis are presented. By using an AMED distillation system the waste heat from closed gas Brayton cycles can be fully utilized to desalinate brackish water and seawater without affecting the cycle thermal efficiency. Analysis shows that cogeneration of electricity and desalinated water can increase net revenues for several Brayton cycles while generating large quantities of potable water. The AMED combining with closed gas Brayton cycles could significantly improve the sustainability and economics of Generation IV high temperature reactors.
Supercritical CO 2 (S-CO 2 ) power plants offer the potential for better economics because of their small size, use of standard materials, and improved electrical power conversion efficiency at modest temperature (400–750°C). Sandia National Laboratories (SNL or Sandia) and the U.S. Department of Energy Office of Nuclear Energy (DOE-NE) are operating a supercritical CO 2 Brayton cycle power system—the Generation IV (Gen IV) split-flow S-CO 2 compressor test loop—currently located in Arvada Colorado, at Barber Nichols, Inc., under contract to Sandia. A photograph of the upgraded loop is shown in Figure E-1. This system is one of the first S-CO 2 power-producing Brayton cycles operating in the world. This report provides a summary of the newly installed hardware and briefly describes some of the test results that were performed in the upgraded split-flow Brayton loop during June and July of 2011. The Gen IV S-CO 2 split-flow Brayton loop was reconfigured to operate as a simple heated recuperated Brayton loop for the testing in this report period. The test loop had just concluded a phase of construction that substantially increased the capability of the loop by adding heaters, a high-temperature (HT) recuperator, more waste heat removal capability, high-power load banks, larger diameter piping with more bends to reduce thermal stress, and more capable scavenging pumps to reduce windage and friction within the turbomachinery and provide greater cooling capabilities. With these additions, the loop greatly increased its capacity for electrical power generation (30–80 kWe per generator, depending on the loop configuration) and its ability to reach high temperatures (up to 810 K [1000°F]). In recent weeks of testing, the test facility began to realize this potential by achieving new records in turbine inlet temperature (615 K [650°F]), shaft speed (52,000 rpm), pressure ratio (1.65), flow rate (2.7 kg/s), and electrical power generated (20 kWe). These operating conditions still remain short of design conditions for each turbine—an inlet temperature of 810 K (1000°F), a pressure ratio of 1.8, a shaft speed of 75,000 rpm, a flow rate of 3.5 kg/s, and a maximum generator power of 125 kWe—but they are beginning to be approached. Not all planned upgrades were implemented due to the limited funding profile of FY2010. Only 520 kW of heater power were installed—not the total 780 kW. Furthermore, because one of the heater controllers was not functioning, only 390 kW of heater power were available. Similarly, the 3-in. piping was installed only in the high-pressure leg of the loop, not in the low-pressure leg, as was originally planned. We also had to rely on the new load bank capability for rapid shutdown situations, and were not able to install a dedicated shutdown resistor. Nevertheless, in spite of these limitations, we operated the loop at record operating conditions and were largely limited only by the facility and support equipment—not the turbomachinery.
The supercritical carbon dioxide (sCO 2 ) Brayton cycle is an upcoming power cycle potentially providing higher energy efficiency and more compact turbomachinery compared to traditionally used Brayton and Rankine cycles. The heat rejected from the sCO 2 Brayton cycle is quite hot (>70 degrees C) and must be cooled before flowing back to the compressor. However, this heat is ideal for producing fresh water with a thermal desalination system. This paper focuses on integrating multi-effect distillation (MED) with the sCO 2 stream exiting the recuperator. A new methodology for integration of MED with the sCO 2 Brayton cycle is proposed for simultaneous production of power and fresh water. The distillate produced does not affect the sCO 2 cycle efficiency, i.e., distillate is produced without being a parasitic load to the power plant compared to conventional integration of MED with steam Rankine cycle. To maximize the energy recovery from the waste heat stream exiting the sCO 2 cycle, a new methodology is formulated and discussed in the Appendix. Integration of MED with a 115 MW e sCO 2 power plant (49.2% efficient) produces 2813 m3/day of distillate and the cost of distilled water is 1.1 $/m 3 . Further, to enhance the distillate production, an innovative MED configuration is proposed, and for the same cycle operating condition with an electrical output 115 MW e , the net distillate production increases by 59% to 4472 m 3 /day at 1 $/m 3 . The cost of desalinated water for the integrated system is 17.8% lower than that of a standalone reverse-osmosis plant having the same capacity. Parametric analysis is performed to calculate the optimal design parameters for the integrated MED-sCO 2 system.
Sandia National Laboratories (SNL) and the Commonwealth Scientific and Industrial Research Organisation (CSIRO) collaborated to conduct an investigation of the dynamic performance of a solar-driven supercritical CO2 (SCO2) Brayton cycle. This was performed on the SNL recompression closed Brayton cycle (RCBC) at the Nuclear Energy Systems Laboratory / Brayton Lab. Historical data were provided to CSIRO since the test assembly remained inoperable throughout the project. Also, multidimensional trade studies were generated using the SNL Recompression closed Brayton cycle Engineering and Trade Studies (RETS©) tool.
A closed Brayton cycle recirculates the working fluid, and the turbine exhaust is used in a recuperating heat exchanger to heat the turbine feed. A "supercritical cycle' is a closed Brayton cycle in which the working fluid, such as supercritical carbon dioxide (s-0O2), is maintained near the critical point during the compression phase of the cycle. The key property of the fluid near its critical point is its higher gas density, closer to that of a liquid than of a gas, allowing for the pumping power in the compressor to be significantly reduced, which results in thermal efficiency that is significantly improved over the efficiency attainable in an ideal-gas Brayton cycle. Another advantage of using a supercritical cycle is that the overall footprint of the power-conversion system can be significantly reduced, as compared to the same power output of a steam-Rankine cycle, due to the high pressure in the system and resulting low volumetric flow rate. This allows for the heat-rejection heat exchanger and turbine to be orders of magnitude smaller than for similar power output steam-Rankine systems. Other potential advantages are the reduced use of water, not only due to the increased efficiency, but due also to the fact that the heat rejection temperature is significantly higher than for steam-Rankine systems, allowing for significant heat rejection directly to air. In 2006, Sandia National Laboratories (SNL), recognizing these potentially significant advantages of a higher efficiency power cycle, used internal funds to establish a testing capability and began partnering with the U.S. Department of Energy Office of Nuclear Energy to develop a laboratory-scale test assembly to show the viability of the underlying science and demonstrate system performance. Since that time, SNL has generated over 100 kW-hours of energy, verified cycle performance, and developed cycle controls and maintenance procedures. The test assembly has successfully operated in different configurations (simple Brayton, waste heat cycle, and recompression) and tested additives to the s-CO 2 working fluid. However, challenges remain to confirm viability of existing components and suitability of materials, demonstrate that theoretical efficiencies are achievable, and integrate and scale up existing technologies to be suitable for a range of applications.
All energy production systems need efficient energy conversion systems. Current Rankine cycles use water to generate steam at temperatures where efficiency is limited to around 40%. As existing fossil and nuclear power plants are decommissioned due to end of effective life and/or societies’ desire for cleaner generation options, more efficient energy conversion is needed to keep up with increasing electricity demands. Modern energy generation technologies, such as advanced nuclear reactors and concentrated solar, coupled to high efficiency sCO 2 conversion systems provide a solution to efficient, clean energy systems. Leading R&D communities worldwide agree that the successful development of sCO 2 Brayton power cycle technology will eventually bring about large-scale changes to existing multi-billion-dollar global markets and enable power applications not currently possible or economically justifiable. However, all new technologies face challenges in the path to commercialization and the electricity sector is distinctively risk averse. The Sandia sCO 2 Brayton team needs to better understand what the electricity sector needs in terms of new technology risk mitigation, generation efficiency, reliability improvements above current technology, and cost requirements which would make new technology adoption worthwhile. Relying on the R&D community consensus that a sCO 2 power cycle will increase the revenue of the electrical industry, without addressing the electrical industry’s concerns, significantly decreases the potential for adoption at commercial scale. With a clear understanding of the market perspectives on technology adoption, including military, private sector, and utilities customers, the Sandia Brayton Team can resolve industry concerns for smoother development and faster transition to commercialization. An extensive customer discovery process, similar to that executed through the NSF’s I-Corp program, is necessary in order to understand the pain points of the market and articulate the value proposition of Brayton systems in terms that engage decision makers and facilitate commercialization of the technology.
Sodium fast reactors (SFR) traditionally adopt the steam Rankine cycle for power conversion. The resulting potential for water-sodium reaction remains a continuing concern which at least partly delays the SFR technology commercialization and is a contributor to higher capital cost. Supercritical CO2 provides an alternative, but is also capable of sustaining energetic chemical reactions with sodium. Recent development on advanced inert-gas Brayton cycles could potentially solve this compatibility issue, increase thermal efficiency, and bring down the capital cost close to light water reactors. In this paper, helium Brayton cycles with multiple reheat and intercooling states are presented for SFRs with reactor outlet temperatures in the range of 510°C to 650°C. The resulting thermal efficiencies range from 39% and 47%, which is comparable with supercritical recompression CO2 cycles (SCO2 cycle). A systematic comparison between multiple reheat helium Brayton cycle and the SCO2 cycle is given, considering compatibility issues, plant site cooling temperature effect on plant efficiency, full plant cost optimization, and other important factors. The study indicates that the multiple reheat helium cycle is the preferred choice over SCO2 cycle for sodium fast reactors.
The sodium intermediate heat transfer loop is used in existing sodium cooled fast reactor (SFR) plant design as a necessary safety measure to separate the radioactive primary loop sodium from the water of the steam Rankine power cycle. However, the intermediate heat transfer loop significantly increases the SFR plant cost and decreases the plant reliability due to the relatively high possibility of sodium leakage. A previous study shows that helium Brayton cycles with multiple reheat and intercooling for SFRs with reactor outlet temperature in the range of 510°C to 650°C can achieve thermal efficiencies comparable to or higher than steam cycles or recently proposed supercritical CO2 cycles. Use of inert helium as the power conversion working fluid provides major advantages over steam or CO2 by removing the requirement for safety systems to prevent and mitigate the sodium-water or sodium-CO2 reactions. A helium Brayton cycle power conversion system therefore makes the elimination of the intermediate heat transfer loop possible. This paper presents a pre-conceptual design of multiple reheat helium Brayton cycle for an advanced loop type SFR. This design widely refers the new horizontal shaft distributed PBMR helium power conversion design features. For a loop type SFR with reactor outlet temperature 550°C, the design achieves 42.4% thermal efficiency with favorable power density comparing with high temperature gas cooled reactors.
Supercritical carbon dioxide (sCO 2 ) Brayton cycles are considered to be a potentially viable option for reducing the cost of electricity generation from solar power tower plants, owing to theoretically high efficiency, low compressor work, and compact turbomachinery. These cycles have relatively high heat rejection temperatures (>70 degrees C), which are ideal for integration with multi-effect distillation (MED) for distillate generation from seawater, without being a parasitic load to the power plant as compared to cogeneration with steam Rankine cycle. The intermittency of solar radiation reduces the annual capacity factor of concentrating solar power (CSP) plants to about 50-60% even with a molten salt storage tank of 10-h. This reduces the annual distillate generation and increases the cost of the distillate. A novel concept to reduce distillate cost is introduced, whereby the waste heat from the sCO 2 Brayton cycle is stored. A two-tank demineralized water storage tank is selected and is shown to allow for the integration of a smaller MED system operating at an increased capacity factor. The optimal storage tank design reduces the distillate cost by 19% and increase the MED capacity factor from 46.4% to 75%. Different coastal locations with good solar resource are studied for cogeneration with the CSP-sCO 2 Brayton cycle. Techno-economic analysis shows the cost of distillate produced by MED is 16% cheaper than the distillate produced from reverse osmosis system for Yanbu, Saudi Arabia.
The supercritical carbon dioxide (S-CO{sub 2}) Brayton cycle is a promising advanced alternative to the Rankine steam cycle and recuperated gas Brayton cycle for the energy converters of specific reactor concepts belonging to the U.S. Department of Energy Generation IV Nuclear Energy Systems Initiative. A new plant dynamics analysis computer code has been developed for simulation of the S-CO{sub 2} Brayton cycle coupled to an autonomous, natural circulation lead-cooled fast reactor (LFR). The plant dynamics code was used to simulate the whole-plant response to accident conditions. The specific design features of the reactor concept influencing passive safety are discussed and accident scenarios are identified for analysis. Results of calculations of the whole-plant response to loss-of-heat sink, loss-of-load, and pipe break accidents are demonstrated. The passive safety performance of the reactor concept is confirmed by the results of the plant dynamics code calculations for the selected accident scenarios.
Brayton cycles (BCs) are gaining renewed interest for use in high-temperature nuclear reactors for power production. This study explores the potential of nuclear Brayton systems in industrial combined heat and power (CHP) production. After a review of the historical deployment and technical development of BC systems for nuclear and cogeneration applications several BCs in CHP configurations are assessed when applied to representative high-temperature reactor types. The analysis emphasizes process heat delivery options, electrical efficiency, and component performance for the case of a direct cycle—Helium BC in a high temperature gas reactor, and an open-air Brayton cycle with a high temperature gas reactor. The results highlight thermodynamic trade-offs in cogeneration operation, particularly in recuperated configurations, and compare BC-based CHP with conventional Rankine cycle (RC) performance. Key findings suggest Helium BCs offer viable CHP performance primarily at lower process heat temperatures, with open air cycles being less efficient. The work also demonstrates trade-off between CHP performance and power production performance with a detailed comparison to where steam RC has better performance. The work is designed to be used as a reference work when cogeneration is proposed from high temperature reactors alongside the use of BCs.
The development of a control strategy for the supercritical CO{sub 2} (S-CO{sub 2}) Brayton cycle has been extended to the investigation of alternate control strategies for a Sodium-Cooled Fast Reactor (SFR) nuclear power plant incorporating a S-CO{sub 2} Brayton cycle power converter. The SFR assumed is the 400 MWe (1000 MWt) ABR-1000 preconceptual design incorporating metallic fuel. Three alternative idealized schemes for controlling the reactor side of the plant in combination with the existing automatic control strategy for the S-CO{sub 2} Brayton cycle are explored using the ANL Plant Dynamics Code together with the SAS4A/SASSYS-1 Liquid Metal Reactor (LMR) Analysis Code System coupled together using the iterative coupling formulation previously developed and implemented into the Plant Dynamics Code. The first option assumes that the reactor side can be ideally controlled through movement of control rods and changing the speeds of both the primary and intermediate coolant system sodium pumps such that the intermediate sodium flow rate and inlet temperature to the sodium-to-CO{sub 2} heat exchanger (RHX) remain unvarying while the intermediate sodium outlet temperature changes as the load demand from the electric grid changes and the S-CO{sub 2} cycle conditions adjust according to the S-CO{sub 2} cycle control strategy. For this option, the reactor plant follows an assumed change in load demand from 100 to 0 % nominal at 5 % reduction per minute in a suitable fashion. The second option allows the reactor core power and primary and intermediate coolant system sodium pump flow rates to change autonomously in response to the strong reactivity feedbacks of the metallic fueled core and assumed constant pump torques representing unchanging output from the pump electric motors. The plant behavior to the assumed load demand reduction is surprising close to that calculated for the first option. The only negative result observed is a slight increase in the intermediate inlet sodium temperatures by about 10 C. This temperature rise could presumably be precluded or significantly reduced through fine adjustment of the control rods and pump motors. The third option assumes that the reactor core power and primary and intermediate system flow rates are ideally reduced linearly in a programmed fashion that instantaneously matches the prescribed load demand. The calculated behavior of this idealized case reveals a number of difficulties because the control strategy for the S-CO{sub 2} cycle overcools the reactor potentially resulting in the calculation of sodium bulk freezing and the onset of sodium boiling. The results show that autonomous SFR operation may be viable for the particular assumed load change transient and deserves further investigation for other transients and postulated accidents.