Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Bragg reflections”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Oblique diffraction geometry for the observation of several non-coplanar Bragg reflections under identical illumination

A method to determine the strain tensor and local lattice rotation with dark-field X-ray microscopy is presented. Using a set of at least three non-coplanar symmetry-equivalent Bragg reflections, the illuminated volume of the sample can be kept constant for all reflections, facilitating easy registration of the measured lattice variations. This requires an oblique diffraction geometry,i.e.the diffraction plane is neither horizontal nor vertical. We derive a closed analytical expression that allows determination of the strain and lattice rotation from the deviation of experimental observables (e.g.goniometer angles) from their nominal values for an unstrained lattice.

Chemistry

Electronic Melting of Silicon in Nanostructures using X-ray Forbidden Bragg Reflections

Abstract We carried out a short beamtime at the Pohang Accelerator Laboratory x-ray Free Electron Laser to perform a pump-probe (PP) laser excitation diffraction experiment on the silicon (222) forbidden Bragg peak. To limit the x-ray penetration, we used a “device layer” silicon film wafer bonded to a silicon substrate. The sample, specially fabricated by MEMC Electronic Materials, had a Si(100) substrate bonded to a 170 nm Si(100) film rotated at 45° for crystallographic isolation. A second sample was reactive-ion-etched down to 52 nm thickness. In the silicon lattice, the covalent bonds are seen exclusively at the 222 reflection. Upon laser excitation, these electrons are expected to be excited to the valence band on femtosecond electronic time scales. The Si(222) reflection is therefore expected to be extinguished on this fast time scale, while the electron–phonon coupled acoustic response is determined by the lattice dynamics. The latter is determined by the speed of sound over the device thickness, which is in the mid-picosecond range.

77 NANOSCIENCE AND NANOTECHNOLOGY

X-ray optics for the cavity-based X-ray free-electron laser

A cavity-based X-ray free-electron laser (CBXFEL) is a possible future direction in the development of fully coherent X-ray sources. CBXFELs consist of a low-emittance electron source, a magnet system with several undulators and chicanes, and an X-ray cavity. The X-ray cavity stores and circulates X-ray pulses for repeated FEL interactions with electron pulses until the FEL reaches saturation. CBXFEL cavities require low-loss wavefront-preserving optical components: near-100%-reflectivity X-ray diamond Bragg-reflecting crystals, outcoupling devices such as thin diamond membranes or X-ray gratings, and aberration-free focusing elements. In the framework of the collaborative CBXFEL research and development project of Argonne National Laboratory, SLAC National Accelerator Laboratory and SPring-8, we report here the design, manufacturing and characterization of X-ray optical components for the CBXFEL cavity, which include high-reflectivity diamond crystal mirrors, a diamond drumhead crystal with thin membranes, beryllium refractive lenses and channel-cut Si monochromators. All the designed optical components have been fully characterized at the Advanced Photon Source to demonstrate their suitability for the CBXFEL cavity application.

47 OTHER INSTRUMENTATION

Massive compression for high data rate macromolecular crystallography (HDRMX): impact on diffraction data and subsequent structural analysis

New higher-count-rate, integrating, large-area X-ray detectors with framing rates as high as 17400 images per second are beginning to be available. These will soon be used for specialized macromolecular crystallography experiments but will require optimal lossy compression algorithms to enable systems to keep up with data throughput. Some information may be lost. Can we minimize this loss with acceptable impact on structural information? To explore this question, we have considered several approaches: summing short sequences of images, binning to create the effect of larger pixels, use of JPEG-2000 lossy wavelet-based compression, and use of Hcompress, which is a Haar-wavelet-based lossy compression borrowed from astronomy. We also explore the effect of the combination of summing, binning, and Hcompress or JPEG-2000. In each of these last two methods one can specify approximately how much one wants the result to be compressed from the starting file size. These provide particularly effective lossy compressions that retain essential information for structure solution from Bragg reflections.

47 OTHER INSTRUMENTATION

Reuniting crystallography with real space: Ab initio structure elucidation with 4D-STEM

Structure elucidation via single-crystal methods has historically lacked experimental access to real-space information, instead relying exclusively on diffraction-space measurements of Bragg reflections. Here we exploit the dual-space imaging power of 4D scanning transmission electron microscopy to meaningfully integrate real-space information into the crystallographic workflow. We show that virtual apertures assembled by segmentation of high-angle annular dark-field images enable i) pixel-by-pixel separation of coherent Bragg signal from clusters of closely spaced nanocrystals and ii) selective extraction of integrated intensities from thinner subregions of individual specimens, facilitating retroactive tuning of multiple scattering artifacts. This strategy empowers us to simply pick and choose whichever nanoscale regions of interest generate the highest-quality diffraction patterns, allowing us to solve several independent structures of the metal-organic framework UiO-66 from specimens whose agglomerated morphology proved intractable for conventional microcrystal electron diffraction. Our method is compatible with both rotational and serial approaches to data processing, ultimately divulging the first scanning nanobeam electron diffraction structures determined by direct methods at subangstrom resolution.

Saha, Ambarneil

Uncovering the phonon spectra and lattice dynamics of plastically deformable InSe van der Waals crystals

Stacking two-dimensional (2D) van der Waals (vdW) materials in a layered bulk structure provides an appealing platform for the emergence of exotic physical properties. As a vdW crystal with exceptional plasticity, InSe offers the opportunity to explore various effects arising from the coupling of its peculiar mechanical behaviors and other physical properties. Here, we employ neutron scattering techniques to investigate the correlations of plastic interlayer slip, lattice anharmonicity, and thermal transport in InSe crystals. Not only are the interlayer slip direction and magnitude well captured by shifts in the Bragg reflections, but we also observe a deviation from the expected Debye behaviour in the heat capacity and lattice thermal conductivity. Combining the experimental data with first-principles calculations, we tentatively attribute the observed evidence of strong phonon-phonon interactions to a combination of a large acoustic-optical frequency resonance and a nesting effect. These findings correlate the macroscopic plastic slip and the microscopic lattice dynamics, providing insights into the mechano-thermo coupling and modulation in 2D vdW materials.

36 MATERIALS SCIENCE

Deciphering supramolecular and polymer-like behavior in metallogels: real-time insights into temperature-modulated gelation and rapid self-assembly dynamics

Bis(pyridyl) urea-based gelators, namely L2 and its isomeric mixture ( L1 + L2 ), are known to self-assemble into 1D architectures capable of inducing supramolecular gelation. Coordination with metal ions such as Ag( I ), Cu( II ), and Fe( III ) introduces structural reinforcement, enabling the formation of distinct 3D networks governed by metal-specific coordination geometries. Here, we present a comprehensive investigation into the temperature-responsive behavior (20–60 °C) of L2 and L1 + L2 , both in the absence and presence of Ag( I ), Dy( III ), Fe( III ), Cu( II ), and Ho( III ), using real-time small-angle neutron scattering (SANS). To probe long-term structural evolution/kinetics of self-assembly, real-time small-angle X-ray scattering (SAXS) was employed on L2 + Ag gels, complemented by differential scanning calorimetry (DSC) to evaluate thermal transitions. Our results reveal strikingly divergent gelation behaviors: L2 forms a highly rigid, covalent polymer-like network, while L1 + L2 exhibits remarkable thermal adaptability. Upon metal coordination, the assemblies exhibit pronounced crystallinity and exceptional thermal stability, as evidenced by persistent Bragg reflections and invariant d-spacings. Intriguingly, L2 : Fe (2 : 1) and L1 : L2 : Fe (0.5 : 0.5 : 1) in acetonitrile-d 3 (ACN-d 3 ) deviate from this trend, forming thermally labile amorphous gels. These systems show a complete loss of crystalline order, reduced Porod exponents—indicative of collapsed or branched fiber morphologies—and prominent melting and glass transition events in DSC. Fitting SANS and SAXS data to the correlation length model unveiled insightful nanostructural features. While most systems displayed minimal temperature-induced variation in mesh size or surface morphology, L2 : Ag in dimethyl sulfoxide-d 6 (DMSO-d 6 )/D 2 O and L2 : Fe (1 : 1) in ACN-d 3 exhibited a rare combination of thermally stable correlation lengths and increasing high- q exponents—strongly suggesting progressive fiber densification or surface smoothing within a robust gel framework. These findings highlight the tunability and structural resilience of supramolecular gels through precise control of ligand architecture, metal coordination, and temperature, offering valuable design principles for functional soft materials.

Pajoubpong, Jinnipha [Univ. of Cincinnati, OH (Uni

Filling data analysis gaps in time-resolved crystallography by machine learning

There is a growing understanding of the structural dynamics of biological molecules fueled by x-ray crystallography experiments. Time-resolved serial femtosecond crystallography (TR-SFX) with x-ray Free Electron Lasers allows the measurement of ultrafast structural changes in proteins. Nevertheless, this technique comes with some limitations. One major challenge is the quality of data from TR-SFX measurements, which often faces issues like data sparsity, partial recording of Bragg reflections, timing errors, and pixel noise. To overcome these difficulties, conventionally, large volumes of data are collected and grouped into a few temporal bins. The data in each bin are then averaged and paired with the mean of their corresponding jittered timestamps. This procedure provides one structure per bin, resulting in a limited number of averaged structures for the entire time interval spanned by the experiment. Therefore, the information on ultrafast structural dynamics at high temporal resolution is lost. This has initiated research for advanced methods of analyzing experimental TR-SFX data beyond the standard binning and averaging method. To address this problem, we use a machine learning algorithm called Nonlinear Laplacian Spectral Analysis (NLSA), which has emerged as a promising technique for studying the dynamics of complex systems. In this work, we demonstrate the power of this algorithm using synthetic x-ray diffraction snapshots from a protein with significant data incompleteness, timing uncertainties, and noise. Our study confirms that NLSA is a suitable approach that effectively mitigates the effects of these artifacts in TR-SFX data and recovers accurate structural dynamics information hidden in such data.

Trujillo, Justin (ORCID:0000000285505360)

X-ray sources for in situ wavelength calibration of x-ray imaging crystal spectrometers

X-ray sources for a range of wavelengths are being considered for in situ calibration of X-ray Imaging Crystal Spectrometers (XICSs) and for monitoring line shifts due to changes in the crystal temperature, which can vary during experimental operation over a day [A. Ince-Cushman et al., Rev. Sci. Instrum. 79, 10E302 (2008), L. Delgado-Aparicio et al., Plasma Phys. Control. Fusion 55, 125011 (2013)]. Such crystal temperature dependent shifts, if not accounted for, could be erroneously interpreted as Doppler shifts leading to errors in plasma flow-velocity measurements. The x-ray sources encompass characteristic x-ray lines falling within the wavelength range of 0.9–4.0 Å, relevant for the XICSs on present and future fusion devices. Several technological challenges associated with the development of x-ray sources for in situ calibration are identified and are being addressed in the design of multiple x-ray tubes, which will be installed inside the spectrometer housing of the XICS for the JT-60SA tokamak. These x-ray sources will be especially useful for in situ calibration between plasma discharges. Here, in this paper, laboratory experiments are described that were conducted with a Cu x-ray source, a heated quartz (102) crystal, and a pixelated Pilatus detector to measure the temperature dependent shifts of the Cu Kα 1 and Kα 2 lines at 1.5405 and 1.5443 Å, respectively, and to evaluate the 2d-lattice constant for the Bragg reflecting crystal planes as a function of temperature, which, in the case of in situ wavelength calibration, would have to be used for numerical analysis of the x-ray spectra from the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Symmetry breaking during low-temperature domain formation in micron-sized magnetite crystals

We report the results of synchrotron Bragg Coherent x-ray Diffraction Imaging (BCDI) experiments to investigate domain formation in a micron-sized magnetite crystal undergoing the Verwey transition at low temperature. A strong splitting of the measured 311 Bragg reflection was observed in the low-temperature phase, indicating the formation of domains. BCDI revealed pronounced strain distributions, characterized by a clear layered stripe domain structure in real-space. Stripes were seen only along the [001] crystallographic direction, normal to the substrate surface direction, breaking the symmetry of the cubic high-temperature phase. It is argued that other domain directions were suppressed by the sample mounting orientation. More surprisingly, only a single domain orientation was observed, suggesting an additional symmetry-breaking influence originating from the shape of the crystal. Gaining insight into how thermal effects induce the formation of layered or striped phases offers a valuable framework for understanding the development of mesoscopic domains and strain patterns in functional materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Mapping Electron Beam-Induced Radiolytic Damage in Molecular Crystals

Every electron crystallography experiment is fundamentally constrained by radiation damage [1]. Despite its crucial importance, little is understood about the onset and progression of radiolysis in beam-sensitive molecular crystals [2]. Since the typical metric used for monitoring the degradation induced by radiolysis is the attenuation of Bragg reflections in electron diffraction patterns [3], the scope of previous analyses [2-6] has mostly been limited to indirect observation via the back focal plane. Here, a simultaneous visualization of the effects of electron beam-induced radiolysis—in both real space and reciprocal space—remains elusive.

74 ATOMIC AND MOLECULAR PHYSICS

Laser-Modulation-Driven X-Ray Pulse Shaping in Regenerative Amplifier Free-Electron Lasers

In this Letter, we present a robust method for generating custom-shaped, coherent hard x-ray pulses in regenerative amplifier free-electron lasers (RAFELs) using laser-induced energy modulation of the electron beam. A temporally shaped optical modulation imprints an optical-wavelength energy pattern on the beam, which interacts with the recirculated seed in the x-ray cavity to generate spectral sidebands. These sidebands lie outside the Bragg reflection bandwidth and are extracted as out-coupled radiation, while the seed is retained for continued amplification, enabling a novel mechanism for both output coupling and pulse shaping. Furthermore, this approach allows deterministic control over the spectral and temporal properties of the emitted x-rays, including multicolor generation, twin-pulse structures, pulse duration tuning, and complex temporal waveforms. Importantly, it does not require modification of the RAFEL cavity or optics and is fully compatible with high-repetition-rate operation, offering a practical pathway to deliver coherent, shaped, and on-demand x-ray pulses for advanced time-resolved and nonlinear x-ray science.

Free-electron lasers

Imaging the Progression of Radiolytic Damage in Molecular Crystals with Scanning Nanobeam Electron Diffraction

Almost every electron microscopy experiment is fundamentally limited by radiation damage. Nevertheless, little is known about the onset and progression of radiolysis in beam-sensitive materials. Here we apply ambient-temperature scanning nanobeam electron diffraction to record simultaneous dual-space movies of organic and organometallic nanocrystals at sequential stages of beam-induced radiolytic decay. We show that the underlying mosaic of coherently diffracting domains undergoes internal rearrangement as a function of accumulating electron fluence, causing the intensities of some associated Bragg reflections to fade nonmonotonically. Furthermore, we demonstrate that repeated irradiation at a single probe position leads to the isotropic propagation of delocalized radiolytic damage well beyond the direct footprint of the incident beam. We refer to these expanding tides of amorphization as “impact craters.”

59 BASIC BIOLOGICAL SCIENCES

Integral X-ray diffuse scattering for studying irradiation-induced dislocation loops in single crystals

Numerical diffuse scattering cross-section calculations are used to establish a rigorous basis for determining the concentration and size distribution of dis­location loops in irradiated single crystals from integral X-ray diffuse scattering (XRDS) measurements. Differential XRDS intensities for prismatic {111} type dislocation loops are numerically calculated as a function of loop radius R and wavevectors q relative to Bragg reflections in tungsten. The results show the well known 1/q 2 Huang scattering form at small q that transitions to a ∼1/q 4 dependence associated with the Stokes–Wilson approximation for q ≳ 1/R. More importantly, they show further that the 1/q 4 falloff is not the asymptotic large-q form of the diffuse scattering for small loops (R < 200 Å) as has often been assumed. Rather, for loop sizes as small as R ≃ 5 Å with strong curvature, the calculations show definitively that the scattering transitions to a robust 1/q 5 falloff at larger q that arises due to the local strains near the dislocation core defining the circumference of the dislocation loops. The presence of this 1/q 5 asymptotic form for both small and large loops is experimentally confirmed using an integral XRDS measurement around the 110 reflection on self-ion-irradiated tungsten combined with numerically calculated integral XRDS cross-sections. Accordingly, the historical two-region theoretical treatment of the cross-sections for integral XRDS is extended to a three-region model that has direct sensitivity to the (first-moment) dislocation line lengths of dislocation loops. In conclusion, these developments enable the use of both numerical and analytically modeled cross-sections to make accurate integral XRDS determinations of dislocation loop sizes and concentrations using modest-intensity laboratory X-ray sources.

42 ENGINEERING

Real-time data processing for serial crystallography experiments

We report the use of streaming data interfaces to perform fully online data processing for serial crystallography experiments, without storing intermediate data on disk. The system produces Bragg reflection intensity measurements suitable for scaling and merging, with a latency of less than 1 s per frame. Our system uses the CrystFEL software in combination with the ASAP::O data framework. In a series of user experiments at PETRA III, frames from a 16 megapixel Dectris EIGER2 X detector were searched for peaks, indexed and integrated at the maximum full-frame readout speed of 133 frames per second. The computational resources required depend on various factors, most significantly the fraction of non-blank frames ('hits'). The average single-thread processing time per frame was 242 ms for blank frames and 455 ms for hits, meaning that a single 96-core computing node was sufficient to keep up with the data, with ample headroom for unexpected throughput reductions. Further significant improvements are expected, for example by binning pixel intensities together to reduce the pixel count. We discuss the implications of real-time data processing on the `data deluge' problem from recent and future photon-science experiments, in particular on calibration requirements, computing access patterns and the need for the preservation of raw data.

47 OTHER INSTRUMENTATION

Improvements in the Sample Space for the Backscattering Silicon Spectrometer (BASIS)

The increase in neutron flux at the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS), currently operating at 2.0 MW proton beam power, has created new opportunities for higher-throughput neutron scattering experiments while also increasing the importance of minimizing background scattering and optimizing sample-environment operations. To address these challenges on the Backscattering Silicon Spectrometer (BA-SIS), several upgrades were developed and evaluated, including boron carbide (B₄C) masking for flat-plate sample containers, multi-cell sample holders used with a vertically translating sample stick, and an automated helium pump and purge (HPP) system for closed-cycle refrigerators. Neutron diffraction measurements demonstrate that B₄C masks reduce background scattering by 49–67%, outperforming both borated aluminum and boron nitride masks while introducing no additional Bragg reflections within the instrument’s accessible Q-range. Commissioning tests of a double-cell flat-plate sample contain-er showed no measurable crosstalk between adjacent sample compartments and con-firmed stable thermal performance, enabling multiple samples to be measured without re-peated temperature cycling. In addition, the automated HPP system provided reproducible sample-space gas handling with approximately ±1 mbar precision while reducing the need for operator intervention and supporting remote operation. Together, these developments improve signal-to-noise performance, increase experimental throughput, and enhance operational efficiency at BASIS, supporting the instrument’s continued operation under higher neutron flux conditions.

Jalarvo, Niina [ORNL] (ORCID:0000000306446866)

Depth-Resolved X-Ray Nanoimaging of Coherent and Incoherent Energy Transport in Silicon Carbide

Understanding lattice dynamics is crucial for optimizing the process of creating functional structures, such as laser writing of color-center defects. However, existing structural probes have difficulty measuring structural dynamics with submicrometer depth sensitivity. Here, in this study, a depth-resolved ultrafast X-ray nanodiffraction technique is developed to track the lattice dynamics of silicon carbide (SiC) in three dimensions. Upon laser excitation of an aluminum layer that acts as a heat and strain transducer, a specular Bragg peak of SiC shows an overall increase in the X-ray diffraction intensity rather than a peak shift. The relaxation dynamics of the increased intensity are significantly different when probed on and off the Bragg peak. The fast subnanosecond relaxation probed at the maximum of the Bragg peak is a result of the propagation of a coherent strain wave along the depth direction, while a slow relaxation probed at the wings of the Bragg peak reflects a localized incoherent lattice heating. To further visualize these processes, spatiotemporal maps were obtained by scanning the relative position and delay between the laser pump and X-ray probe beams, which capture the propagation of the strain wave, as well as a stationary structural distortion close to the aluminum/SiC interface. These depth-resolved structural measurements disentangle energy dissipation mechanisms in laser-excited SiC, and they open opportunities for finer control of, for example, the formation of optically addressable defect complexes central to quantum information applications.

X-ray nanodiffraction

Results from a synthetic model of the ITER XRCS-Core diagnostic based on high-fidelity x-ray ray tracing

A high-fidelity synthetic diagnostic has been developed for the ITER core x-ray crystal spectrometer diagnostic based on x-ray ray tracing. This synthetic diagnostic has been used to model expected performance of the diagnostic, to aid in diagnostic design, and to develop engineering tolerances. The synthetic model is based on x-ray ray tracing using the recently developed xicsrt ray tracing code and includes a fully three-dimensional representation of the diagnostic based on the computer aided design. The modeled components are: plasma geometry and emission profiles, highly oriented pyrolytic graphite pre-reflectors, spherically bent crystals, and pixelated x-ray detectors. Plasma emission profiles have been calculated for Xe 44+ , Xe 47+ , and Xe 51+ , based on an ITER operational scenario available through the Integrated Modelling & Analysis Suite database, and modeled within the ray tracing code as a volumetric x-ray source; the shape of the plasma source is determined by equilibrium geometry and an appropriate wavelength distribution to match the expected ion temperature profile. All individual components of the x-ray optical system have been modeled with high-fidelity producing a synthetic detector image that is expected to closely match what will be seen in the final as-built system. Particular care is taken to maintain preservation of photon statistics throughout the ray tracing allowing for quantitative estimates of diagnostic performance.

47 OTHER INSTRUMENTATION