At least 19 records

Multi-cone x-ray imaging Bragg crystal spectrometer

Embodiments provide a multi-cone X-ray imaging Bragg crystal spectrometer for spectroscopy of small x-ray sources with a well-defined spectral resolution. The spectrometer includes a glass substrate machined to a multi-cone form; and a thin crystal slab attached to the glass substrate, whereby the multi-cone X-ray imaging Bragg crystal spectrometer provides rotational symmetry of a ray pattern, providing for accurate imaging, for each wavelength in the spectral range of interest. One or more embodiments include a streak camera and/or a gated strip detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparing plasma conditions in short-pulse-heated foils via fine-structure x-ray emission

Fine-structure x-ray spectra have been measured from foils with embedded tracer layers at two laser facilities. In this work, a suite of layered foils with thin Ti tracers under varied tamper layers was studied at both the Titan and the ALEPH 400 nm laser facilities, where Ti Heα emission was recorded using a high-resolution Bragg crystal spectrometer. Several indicators of plasma parameters are examined in the spectra, including temperature- and density-dependent line ratios and line broadening from Stark and opacity effects. Spectra indicate that (1) the plasma density at ALEPH is significantly higher than at Titan and (2) the electron temperature is high for near-surface layers at both facilities but drops more quickly with depth at ALEPH. These inferences of plasma conditions are consistent with differing levels of temporal contrast at each laser facility.

47 OTHER INSTRUMENTATION↗

Development of improved higher-order correction for the NIF opacity spectrometer

X-ray opacity measurements on the National Ignition Facility (NIF) are in the process of reproducing earlier measurements from the Sandia Z Facility, in particular for oxygen and iron plasmas. These measurements have the potential to revise our understanding of the “solar problem” and of the hot degenerate Q class white dwarf structure by probing plasma conditions near the base of their convection zones. Accurate opacity measurements using soft x-ray Bragg crystal spectrometers require correction for higher-order diffraction effects. Extending prior work in this area [Dutra et al., Review of Scientific Instruments 93, 113527 (2022)], we have developed a new method to remove higher-order spectral components from NIF opacity spectrometer data. Furthermore, by modeling absorption and backlighting continuum spectra and subtracting the second- and third-order components from the measured data, we are able to perform this correction while avoiding imprinting first-order model line features onto the data.

79 ASTRONOMY AND ASTROPHYSICS↗

National Opacity Program: Analysis of Opacity-relevant X-ray Emission Spectra (Milestone Report ID 7121)

We have produced high energy density iron plasmas at temperatures above 1 keV and electron densities exceeding 1023 cm -3 (~ 1 g/cm 3 ) using the Orion laser at the Atomic Weapons Establishment. These plasmas were created by irradiating 50 µm diameter layered targets with frequency doubled (λ = 527 nm), 1 ps laser pulses focused to a 100 µm diameter producing an irradiance of ~ 2 x 10 18 W/cm 2 . The buried layer targets consist of 160 nm iron sulfide (FeS), 60 nm potassium chloride (KCl), and 15 nm carbon. The combined layers are tamped on both sides with 3 µm of parylene-N. The x-ray emission from the plasma was measured using two time-resolved, and four time-integrated Bragg crystal spectrometers, as well as one time-integrated imaging system. One time-resolved x-ray spectrometer measured emission from L-shell transitions in highly charged iron, the other from K-shell transitions in helium-like S 14+ and hydrogen-like S 15+ . The time-integrated spectrometers are intensity-calibrated and measured emission from K-shell transitions in sulfur, potassium, chlorine, and both K-shell and L-shell transitions in iron. The density and temperature of the plasma were determined by modeling the x-ray spectra using different spectral and hydrodynamic modeling packages. A brief overview of the uncertainties associated with the measurements and models are presented. We also give an overview of our 1-D HYDRA-DCA radiation-hydrodynamics model and improvements for future work. Our results aid in assessing experimental uncertainties associated with plasma uniformity and with x-ray emission employed as diagnostics in opacity experiments at temperatures and densities not achievable elsewhere and represent a significant step in creating and diagnosing plasmas near LTE. These results are summarized as part of the completion requirements for milestone 7121

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physics of Ultra-High Energy Density Relativistic Plasmas from Ordered Nanostructures

This award funded a four-year program at Colorado State University on the physics of ultra-high energy density plasmas generated by focusing femtosecond, >1021 Wcm-2 laser pulses onto ordered nanowire arrays. We used the ALEPH petawatt-class Ti:Sa laser with its high contrast 400 nm second harmonic beamline to irradiate arrays of Ni and TiO2 nanowires made by template assisted electrodeposition and atomic layer deposition over a wide range of average densities. We met two of the three original project goals: radial ion acceleration via doppler shifted K shell emission, and time and spectrally resolved K shell measurements. The main experimental advance was integrating the Lawrence Livermore National Laboratory (LLNL) TREX ultrafast x-ray streak camera with a suite of spherically bent quartz Bragg crystal spectrometers built using Princeton Plasma Physics Laboratory (PPPL) methodology. This is the first TREX-on-bent-quartz setup fielded at a femtosecond, >1021 Wcm-2 facility. It is now a permanent diagnostic at ALEPH and is offered to the LaserNetUS user community. The program produced three peer reviewed journal articles that acknowledge this award. The platform will continue at the upgraded CSU ATLAS facility, where the ALEPH laser is being upgraded to 2 PW.

Hollinger, Reed [Colorado State University]↗

Absolute calibration of the conical crystal configuration of the zinc spectrometer (ZSPEC) at the OMEGA laser facility

In this study, we present the absolute calibration of the conical crystal for the zinc spectrometer (ZSPEC), an x-ray spectrometer at the OMEGA laser facility at the Laboratory for Laser Energetics. The ZSPEC was originally designed to measure x-ray Thomson scattering using flat or cylindrically curved highly oriented pyrolytic graphite crystals centered around Zn He-alpha emission at 9 keV. To improve the useful spectral range and collection efficiency of the ZSPEC, a conical highly annealed pyrolytic graphite crystal was fabricated for the ZSPEC. The conically bent crystal in the Hall geometry produces a line focus perpendicular to the spectrometer axis, corresponding to the detector plane of electronic detectors at large scale laser facilities such as OMEGA, extending the useful range of the spectrometer to 7–11 keV. Further, using data collected using a microfocus Mo x-ray source, we determine important characteristics of ZSPEC such as the dispersion, spatial resolution, and absolute sensitivity of the instrument. A ray-trace model of ZSPEC provides another point of agreement in calculations of the ZSPEC dispersion and crystal response.

47 OTHER INSTRUMENTATION↗

2nd and 3rd order spectral energy corrections with penumbral de-blurring methodology for opacity platform used on the National Ignition Facility

The Opacity Spectrometer (OpSpec) used in the National Ignition Facility’s opacity experiments measures x-ray spectra from 0.9 to 2.1 keV from the different experimental regions: the backlight source, emission source, and the absorption region with the transmission calculated from these regions. The OpSpec designs have gone through several iterations to help improve the signal-to-noise ratio, remove alternate crystal plane reflections, and improve spectral resolution, which helps to increase the validity of the opacity measurements. However, the source spans well outside the current working spectral range, and higher-order reflections are intrinsic to the crystal, which increases the overall signal seen in the data regions. The recorded data are the convolution of 1st order transmission, higher-order reflections, and the penumbra blurring. In conclusion, this work represents the details for deconvolving the 2nd and 3rd order spectral energy corrections with a penumbral de-blurring to correct the relative measurement of x-ray intensity of different spectral energies and further analysis of datasets relevant to the opacity experiments.

47 OTHER INSTRUMENTATION↗

High-resolution x-ray spectrometer for x-ray absorption fine structure spectroscopy

Two extended x-ray absorption fine structure flat crystal x-ray spectrometers (EFX’s) were designed and built for high-resolution x-ray spectroscopy over a large energy range with flexible, on-shot energy dispersion calibration capabilities. The EFX uses a flat silicon [111] crystal in the reflection geometry as the energy dispersive optic covering the energy range of 6.3–11.4 keV and achieving a spectral resolution of 4.5 eV with a source size of 50 μm at 7.2 keV. A shot-to-shot configurable calibration filter pack and Bayesian inference routine were used to constrain the energy dispersion relation to within ±3 eV. The EFX was primarily designed for x-ray absorption fine structure (XAFS) spectroscopy and provides significant improvement to the Laboratory for Laser Energetics’ OMEGA-60 XAFS experimental platform. The EFX is capable of performing extended XAFS measurements of multiple absorption edges simultaneously on metal alloys and x-ray absorption near-edge spectroscopy to measure the electron structure of compressed 3d transition metals.

47 OTHER INSTRUMENTATION↗

Quantifying electron temperature distributions from time-integrated x-ray emission spectra

K-shell x-ray emission spectroscopy is a standard tool used to diagnose the plasma conditions created in high-energy-density physics experiments. In the simplest approach, the emissivity-weighted average temperature of the plasma can be extracted by fitting an emission spectrum to a single temperature condition. It is known, however, that a range of plasma conditions can contribute to the measured spectra due to a combination of the evolution of the sample and spatial gradients. In this work, we define a parameterized model of the temperature distribution and use Markov Chain Monte Carlo sampling of the input parameters, yielding uncertainties in the fit parameters to assess the uniqueness of the inferred temperature distribution. Here we present the analysis of time-integrated S and Fe x-ray spectroscopic data from the Orion laser facility and demonstrate that while fitting each spectral region to a single temperature yields two different temperatures, both spectra can be fit simultaneously with a single temperature distribution. We find that fitting both spectral regions together requires a maximum temperature of $1310^{+90}_{-70}$ eV with significant contributions from temperatures down to 200 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diffraction gratings with two-orders-of-magnitude-enhanced dispersion rates for sub-meV resolution soft X-ray spectroscopy

Diffraction gratings with large angular dispersion rates are central to obtaining high spectral resolution in grating spectrometers operating over a broad spectral range from infrared to soft X-ray domains. The greatest challenge is of course to achieve large dispersion rates in the short-wavelength X-ray domain. Here it is shown that crystals in non-coplanar asymmetric X-ray Bragg diffraction can function as high-reflectance broadband soft X-ray diffraction gratings with dispersion rates that are at least two orders of magnitude larger than those that are possible with state-of-the-art man-made gratings. Additionally, this opens new opportunities to design and implement soft X-ray resonant inelastic scattering (RIXS) spectrometers with spectral resolutions that are up to two orders of magnitude higher than what is currently possible, to further advance a very dynamic field of RIXS spectroscopy, and to make it competitive with inelastic neutron scattering. Examples of large-dispersion-rate crystal diffraction gratings operating near the 930 eV L 3 absorption edge in Cu and of the 2.838 keV L 3 -edge in Ru are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First use of an InSb crystal for x-ray imaging spectroscopy of highly ionized tungsten in the Wendelstein 7-X stellarator

Advances in time and space resolved measurements of highly charged states of tungsten (W) through x-ray imaging spectroscopy have enabled investigation of impurity transport in the Wendelstein 7-X (W7-X) stellarator. The high-resolution x-ray imaging spectrometer (HR-XIS) system on W7-X utilizes the Bragg diffraction properties of a set of multiple crystals to measure a range of impurity emission lines within sections of the 1–7 Å wavelength range, including transitions of W. A new indium–antimonide crystal has been installed on the HR-XIS system to allow viewing of the 5.5–6.2 Å region focusing on emissions of W. Consequently, many bright W emission lines from W 40+ to W 47+ were observed in this wavelength range, both in plasmas with injected W and in those with only intrinsic W impurity sources, showing the high sensitivity of the diagnostic. Three W 46+ emissions correspond in wavelength and intensity with calculated photon emissivity coefficients and can be exploited for W transport and concentration applications in plasmas with T e ≳ 2.1 keV. Here, an estimate of the core W density behavior in two separate turbulence-reduced ‘high-performance’ (HP) discharges on W7-X is done using the 5.6893 Å W 46+ line. The n W behavior in HP scenarios can be explained by previous experimental results and neoclassical predictions.

XICS↗

X-ray continuum spectroscopy of inertial confinement fusion implosions at the National Ignition Facility

A methodology for measuring x-ray continuum spectra of inertial confinement fusion (ICF) implosions is described. The method relies on the use of ConSpec, a high-throughput spectrometer using a highly annealed pyrolytic graphite crystal , which measures the spectra in the ≃20–30 keV range. Due to its conical shape, the crystal is sagittally focusing a Bragg-reflected x-ray spectrum into a line, which enhances the recorded x-ray emission signal above the high neutron-induced background accompanying ICF implosions at the National Ignition Facility. To improve the overall measurement accuracy, the sensitivity of the spectrometer measured in an off-line x-ray laboratory setting was revised. The error analysis was expanded to include the accuracy of the off-line measurements, the effect of the neutron-induced background, as well as the influence of possible errors in alignment of the instrument to the ICF target. Here we demonstrate how the improved methodology is applied in the analysis of ConSpec data with examples of a relatively low-neutron-yield implosion using a tritium–hydrogen–deuterium mix as a fuel and a high-yield deuterium–tritium (DT) implosion producing high level of the background. In both cases, the shape of the measured spectrum agrees with the exponentially decaying spectral shape of bremsstrahlung emission to within ±10%. In the case of the high-yield DT experiment, non-monotonic deviations slightly exceeding the measurement uncertainties are observed and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High resolution x-ray emission spectrometer for multiple hard x-ray emission lines: Demonstration for Cu Kα and Kβ emissions

In this work, we present a compact 3D printed x-ray emission spectrometer based on the von Hamos geometry that represents a significant upgrade to the existing von Hamos geometry-based miniature x-ray emission spectrometer (miniXES). The upgrades include the incorporation of a higher pixel density 500K detector for improved energy resolution and an enlarged sample area to accommodate a wider range of sample formats. The versatile spectrometer houses removable crystal holders that can be easily exchanged, as well as movable alignment eyelets that give flexibility in Bragg angle selection. Designed for ease of manufacture, all the components, except for the apertures, can be 3D printed and readily assembled. We describe its implementation in measurements of resonant and non-resonant Cu Kα and Kβ x-ray emission and report the theoretical and measured energy resolution and collected solid angle of the emission.

3D printing↗

Streaked Sub-ps-resolution X-ray Line Shapes and Implications for Solid-density Plasma Dynamics

A high-resolution x-ray spectrometer was coupled with an ultrafast x-ray streak camera to produce time-resolved line shape spectra measured from hot, solid-density plasmas. A Bragg crystal was placed near a laser-produced plasma to maximize throughput; alignment tolerances were established by raytracing. The streak camera produced single-shot time-resolved spectra, heavily sloped due to photon time-of-flight differences, with sufficient reproducibility to accumulate photon statistics. The images are time-calibrated by the slope of streaked spectra and dewarped to generate spectra emitted at different times defined at the source. The streaked spectra demonstrate the evolution of spectral shoulders and other features on ps timescales, showing the feasibility of plasma parameter measurements on the rapid timescales necessary to study high-energy-density plasmas.

High-energy-density plasmas↗

Absolute throughput calibration of multiple spherical crystals for the Orion High-REsolution X-ray spectrometer (OHREX)

We present absolute throughput analysis of several crystals for the Orion High-REsolution X-ray (OHREX) imaging crystal spectrometer using ray tracing and experimental measurements. The OHREX spectrometer is a high-resolution x-ray spectrometer designed to measure spectral line shapes at the Orion laser facility. The spectrometer is fielded with up to two spherical crystals simultaneously covering two independent spectral ranges. Each crystal has a nominal radius of curvature of R = 67.2 cm and is fielded at a nominal Bragg angle of 51.3°. To cover different bands of interest, several different crystals are available, including Ge (111), KAP, and several cuts of quartz, whose resolving power λ/Δλ exceeds 10 000. The calibrated response of the available crystals has previously been reported from measurements at the EBIT-I electron beam ion trap at Lawrence Livermore National Laboratory. Here, we model the absolute throughput of each crystal using ray tracing and verify the results using experimental data for the quartz $(10\bar{1}1)$ crystal.

47 OTHER INSTRUMENTATION↗

A new μ -high energy resolution fluorescence detection microprobe imaging spectrometer at the Stanford Synchrotron Radiation Lightsource beamline 6-2

In this report we describe a new synchrotron X-ray Fluorescence (XRF) imaging instrument with an integrated High Energy Fluorescence Detection X-ray Absorption Spectroscopy (HERFD-XAS) spectrometer at the Stanford Synchrotron Radiation Lightsource at beamline 6-2. The X-ray beam size on the sample can be defined via a range of pinhole apertures or focusing optics. XRF imaging is performed using a continuous rapid scan system with sample stages covering a travel range of 250 × 200 mm 2 , allowing for multiple samples and/or large samples to be mounted. The HERFD spectrometer is a Johann-type with seven spherically bent 100 mm diameter crystals arranged on intersecting Rowland circles of 1 m diameter with a total solid angle of about 0.44% of 4π sr. A wide range of emission lines can be studied with the available Bragg angle range of ~64.5°–82.6°. With this instrument, elements in a sample can be rapidly mapped via XRF and then selected features targeted for HERFD-XAS analysis. Furthermore, utilizing the higher spectral resolution of HERFD for XRF imaging provides better separation of interfering emission lines, and it can be used to select a much narrower emission bandwidth, resulting in increased image contrast for imaging specific element species, i.e., sparse excitation energy XAS imaging. This combination of features and characteristics provides a highly adaptable and valuable tool in the study of a wide range of materials.

47 OTHER INSTRUMENTATION↗