Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Bone imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Enhancing synchrotron radiation micro-CT images using deep learning: an application of Noise2Inverse on bone imaging

In bone-imaging research, in situ synchrotron radiation micro-computed tomography (SRµCT) mechanical tests are used to investigate the mechanical properties of bone in relation to its microstructure. Low-dose computed tomography (CT) is used to preserve bone's mechanical properties from radiation damage, though it increases noise. To reduce this noise, the self-supervised deep learning method Noise2Inverse was used on low-dose SRµCT images where segmentation using traditional thresholding techniques was not possible. Simulated-dose datasets were created by sampling projection data at full, one-half, one-third, one-fourth and one-sixth frequencies of an in situ SRµCT mechanical test. After convolutional neural networks were trained, Noise2Inverse performance on all dose simulations was assessed visually and by analyzing bone microstructural features. Visually, high image quality was recovered for each simulated dose. Lacunae volume, lacunae aspect ratio and mineralization distributions shifted slightly in full, one-half and one-third dose network results, but were distorted in one-fourth and one-sixth dose network results. Following this, new models were trained using a larger dataset to determine differences between full dose and one-third dose simulations. Significant changes were found for all parameters of bone microstructure, indicating that a separate validation scan may be necessary to apply this technique for microstructure quantification. Noise present during data acquisition from the testing setup was determined to be the primary source of concern for Noise2Inverse viability. While these limitations exist, incorporating dose calculations and optimal imaging parameters enables self-supervised deep learning methods such as Noise2Inverse to be integrated into existing experiments to decrease radiation dose.

Obata, Yoshihiro (ORCID:0000000303659129)↗

Exploiting voxel-sparsity for bone imaging with sparse-view cone-beam computed tomography

An optimization-based image reconstruction frame work is developed specifically for bone imaging. This framework exploits voxel-sparsity by use of ℓ 1 -norm image regularization and it enables image reconstruction from sparse-view cone-beam computed tomography (CBCT) acquisition. The effectiveness of the voxel-sparsity regularization is enhanced by using a blurred image representation. Ramp-filtering is included in the data discrepancy term and it has the effect of acting as a preconditioner, reducing the necessary number of iterations. The bone image reconstruction framework is demonstrated on CBCT data taken from an equine metacarpal condyle specimen.

Bone imaging↗

First Multimodal, Three-Dimensional, Image-Guided Total Marrow Irradiation Model for Preclinical Bone Marrow Transplantation Studies

Total marrow irradiation (TMI) has significantly advanced radiation conditioning for hematopoietic cell transplantation in hematologic malignancies by reducing conditioning-induced toxicities and improving survival outcomes in relapsed/refractory patients. However, the relapse rate remains high, and the lack of a preclinical TMI model has hindered scientific advancements. To accelerate TMI translation to the clinic, we developed a TMI delivery system in preclinical models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Primary radiation damage in bone evolves via collagen destruction by photoelectrons and secondary emission self-absorption

X-rays are invaluable for imaging and sterilization of bones, yet the resulting ionization and primary radiation damage mechanisms are poorly understood. Here we monitor in-situ collagen backbone degradation in dry bones using second-harmonic-generation and X-ray diffraction. Collagen breaks down by cascades of photon-electron excitations, enhanced by the presence of mineral nanoparticles. We observe protein disintegration with increasing exposure, detected as residual strain relaxation in pre-stressed apatite nanocrystals. Damage rapidly grows from the onset of irradiation, suggesting that there is no minimal ‘safe’ dose that bone collagen can sustain. Ionization of calcium and phosphorous in the nanocrystals yields fluorescence and high energy electrons giving rise to structural damage that spreads beyond regions directly illuminated by the incident radiation. Our findings highlight photoelectrons as major agents of damage to bone collagen with implications to all situations where bones are irradiated by hard X-rays and in particular for small-beam mineralized collagen fiber investigations.

36 MATERIALS SCIENCE↗

Using ultrasonic attenuation in cortical bone to infer distributions on pore size

Here, in this work we infer the underlying distribution on pore radius in human cortical bone samples using ultrasonic attenuation data. We first discuss how to formulate polydisperse attenuation models using a probabilistic approach and the Waterman Truell model for scattering attenuation. We then compare the Independent Scattering Approximation and the higher-order Waterman Truell models’ forward predictions for total attenuation in polydisperse samples. Following this, we formulate an inverse problem under the Prohorov Metric Framework coupled with variational regularization to stabilize this inverse problem. We then use experimental attenuation data taken from human cadaver samples and solve inverse problems resulting in nonparametric estimates of the probability density function on pore radius. We compare these estimates to the “true” microstructure of the bone samples determined via microCT imaging. We find that our methodology allows us to reliably estimate the underlying microstructure of the bone from attenuation data.

97 MATHEMATICS AND COMPUTING↗

Spatial control of perilacunar canalicular remodeling during lactation

Abstract Osteocytes locally remodel their surrounding tissue through perilacunar canalicular remodeling (PLR). During lactation, osteocytes remove minerals to satisfy the metabolic demand, resulting in increased lacunar volume, quantifiable with synchrotron X-ray radiation micro-tomography (SRµCT). Although the effects of lactation on PLR are well-studied, it remains unclear whether PLR occurs uniformly throughout the bone and what mechanisms prevent PLR from undermining bone quality. We used SRµCT imaging to conduct an in-depth spatial analysis of the impact of lactation and osteocyte-intrinsic MMP13 deletion on PLR in murine bone. We found larger lacunae undergoing PLR are located near canals in the mid-cortex or endosteum. We show lactation-induced hypomineralization occurs 14 µm away from lacunar edges, past a hypermineralized barrier. Our findings reveal that osteocyte-intrinsic MMP13 is crucial for lactation-induced PLR near lacunae in the mid-cortex but not for whole-bone resorption. This research highlights the spatial control of PLR on mineral distribution during lactation.

59 BASIC BIOLOGICAL SCIENCES↗

Dimorphic Mechanisms of Fragility in Diabetes Mellitus: the Role of Reduced Collagen Fibril Deformation

ABSTRACT Diabetes mellitus (DM) is an emerging metabolic disease, and the management of diabetic bone disease poses a serious challenge worldwide. Understanding the underlying mechanisms leading to high fracture risk in DM is hence of particular interest and urgently needed to allow for diagnosis and treatment optimization. In a case–control postmortem study, the whole 12th thoracic vertebra and cortical bone from the mid-diaphysis of the femur from male individuals with type 1 diabetes mellitus (T1DM) (n = 6; 61.3 ± 14.6 years), type 2 diabetes mellitus (T2DM) (n = 11; 74.3 ± 7.9 years), and nondiabetic controls (n = 18; 69.3 ± 11.5) were analyzed with clinical and ex situ imaging techniques to explore various bone quality indices. Cortical collagen fibril deformation was measured in a synchrotron setup to assess changes at the nanoscale during tensile testing until failure. In addition, matrix composition was analyzed including determination of cross-linking and non-crosslinking advanced glycation end-products like pentosidine and carboxymethyl-lysine. In T1DM, lower fibril deformation was accompanied by lower mineralization and more mature crystalline apatite. In T2DM, lower fibril deformation concurred with a lower elastic modulus and tendency to higher accumulation of non-crosslinking advanced glycation end-products. The observed lower collagen fibril deformation in diabetic bone may be linked to altered patterns mineral characteristics in T1DM and higher advanced glycation end-product accumulation in T2DM. © 2022 The Authors. Journal of Bone and Mineral Research published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research (ASBMR).

59 BASIC BIOLOGICAL SCIENCES↗

Longitudinal Preclinical Imaging Characterizes Extracellular Drug Accumulation After Radiation Therapy in the Healthy and Leukemic Bone Marrow Vascular Microenvironment

Recent initial findings suggest that radiation therapy improves blood perfusion and cellular chemotherapy uptake in mice with leukemia. However, the ability of radiation therapy to influence drug accumulation in the extracellular bone marrow tissue is unknown, due in part to a lack of methodology. This study developed longitudinal quantitative multiphoton microscopy (L-QMPM) to characterize the bone marrow vasculature (BMV) and drug accumulation in the extracellular bone marrow tissue before and after radiation therapy in mice bearing leukemia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Genetic interactions between polycystin-1 and Wwtr1 in osteoblasts define a novel mechanosensing mechanism regulating bone formation in mice

Molecular mechanisms transducing physical forces in the bone microenvironment to regulate bone mass are poorly understood. Here, we used mouse genetics, mechanical loading, and pharmacological approaches to test the possibility that polycystin-1 and Wwtr1 have interdependent mechanosensing functions in osteoblasts. We created and compared the skeletal phenotypes of control Pkd1 flox/+ ;Wwtr1 flox/+ , Pkd1 Oc-cKO , Wwtr1 Oc-cKO , and Pkd1/Wwtr1 Oc-cKO mice to investigate genetic interactions. Consistent with an interaction between polycystins and Wwtr1 in bone in vivo, Pkd1/Wwtr1 Oc-cKO mice exhibited greater reductions of BMD and periosteal MAR than either Wwtr1 Oc-cKO or Pkd1 Oc-cKO mice. Micro-CT 3D image analysis indicated that the reduction in bone mass was due to greater loss in both trabecular bone volume and cortical bone thickness in Pkd1/Wwtr1 Oc-cKO mice compared to either Pkd1 Oc-cKO or Wwtr1 Oc-cKO mice. Pkd1/Wwtr1 Oc-cKO mice also displayed additive reductions in mechanosensing and osteogenic gene expression profiles in bone compared to Pkd1 Oc-cKO or Wwtr1 Oc-cKO mice. Moreover, we found that Pkd1/Wwtr1 Oc-cKO mice exhibited impaired responses to tibia mechanical loading in vivo and attenuation of load-induced mechanosensing gene expression compared to control mice. Finally, control mice treated with a small molecule mechanomimetic, MS2 that activates the polycystin complex resulted in marked increases in femoral BMD and periosteal MAR compared to vehicle control. In contrast, Pkd1/Wwtr1 Oc-cKO mice were resistant to the anabolic effects of MS2. These findings suggest that PC1 and Wwtr1 form an anabolic mechanotransduction signaling complex that mediates mechanical loading responses and serves as a potential novel therapeutic target for treating osteoporosis.

60 APPLIED LIFE SCIENCES↗

A Comparative Study on Representativeness and Stochastic Efficacy of Miniature Tensile Specimen Testing

Here, in this article, a miniature dog bone tensile coupon design was tested against the existing ASTM standard specimen design. Specimens were prepared from commercially sourced austenitic stainless steel 304 alloy, and a defect-ridden additively manufactured 304L alloy was studied. By utilizing a tensile specimen design that is 1/230th volume of the smallest ASTM E8-04(2016), Standard Test Methods for Tension Testing of Metallic Materials, dog bone specimen, coupled to a digital image correlation (DIC) setup, case studies were performed to compare tensile property measurements and strain field evolution. Whereas yield strength measurements were observed to be similar, post-yield, the ultimate strength measurements and ductility measurements from the miniature specimens were observed to be higher than the ASTM specimen design. Although the strength measurements were comparable, the strain evolution was found to differ in the miniature specimens. Studies to assess effects of varying thickness and defect population were also pursued on the miniature tensile specimen. From the DIC strain field estimations, the peak local strain values at ultimate tensile strength were observed to be increasing with reducing specimen thickness. Testing of defect ridden stainless steel revealed the sensitivity to failure through strain localization and the influence of defect size was captured in the strength measurements.

36 MATERIALS SCIENCE↗

Independent Evidence for the Preservation of Endogenous Bone Biochemistry in a Specimen of Tyrannosaurus rex

Biomolecules preserved in deep time have potential to shed light on major evolutionary questions, driving the search for new and more rigorous methods to detect them. Despite the increasing body of evidence from a wide variety of new, high resolution/high sensitivity analytical techniques, this research is commonly met with skepticism, as the long standing dogma persists that such preservation in very deep time (>1 Ma) is unlikely. The Late Cretaceous dinosaur Tyrannosaurus rex (MOR 1125) has been shown, through multiple biochemical studies, to preserve original bone chemistry. Here, we provide additional, independent support that deep time bimolecular preservation is possible. We use synchrotron X-ray fluorescence imaging (XRF) and X-ray absorption spectroscopy (XAS) to investigate a section from the femur of this dinosaur, and demonstrate preservation of elements (S, Ca, and Zn) associated with bone remodeling and redeposition. We then compare these data to the bone of an extant dinosaur (bird), as well as a second non-avian dinosaur, Tenontosaurus tilletti (OMNH 34784) that did not preserve any sign of original biochemistry. Our data indicate that MOR 1125 bone cortices have similar bone elemental distributions to that of an extant bird, which supports preservation of original endogenous chemistry in this specimen.

59 BASIC BIOLOGICAL SCIENCES↗

Mechanical behavior analysis using small-size graphite disc compression testing with digital image correlation methods

The ASTM International Standard Test Method for Tensile Stress-Strain of Carbon and Graphite (ASTM C749) requires dog-bone shaped specimens. Unfortunately, specimen sizes required in ASTM C749 are much too large for irradiation within a test reactor and are incompatible with irradiation capsule volumes, molten salt degradation facilities, or oxidation apparatus. The ASTM International Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite (ASTM D8289) was developed as an alternative that provides a means for testing tensile properties using smaller specimens when geometric constraints are present. However, the important stress–strain relation throughout the test loading history that could be recorded using ASTM C749 is lost by using ASTM D8289 because of the difficulties involved with using traditional strain gauges or extensometers on such a small specimen. In this work, a digital image correlation (DIC) method, which uses a full-field noncontact surface displacement measurement technique, was applied along with the ASTM D8289 splitting tensile test on eight small samples of graphite grade Mersen 2114 to track their deformation during compressive loading. Initial results showed that the DIC technique can measure the surface displacement/strain on these small (Ø6 × 3 mm) graphite specimens with high accuracy and good repeatability, indicating that the DIC technique, combined with the small-disc splitting tensile test in ASTM D8289, can capture the strain evolution in the test. In conclusion, further comparison of measured strains with analytical and numerical simulation results provides additional understanding of the mechanical behaviour of this nuclear graphite material in complex stress states.

36 MATERIALS SCIENCE↗

Stochastic parametric skeletal dosimetry model for humans: Pediatric and adult computational skeleton phantoms for internal bone marrow dosimetry

Currently, computational phantoms that simulate skeletal tissues are used in active red bone marrow (AM) internal dosimetry. Up-to-date reference computational phantoms recommended by the ICRP are based on the analysis of CT-images of cadavers. Such phantoms have significant disadvantages. One disadvantage is that the assessment of uncertainty due to the population variability of skeleton dimensions and microstructure results from the limited availability of autopsy material. Another disadvantage is the simplified modelling of cortical layer and bone microarchitecture. A method of stochastic parametric skeletal dosimetry modelling of the bone structures – SPSD modelling – has been developed as an alternative to the ICRP reference phantoms. In the framework of this approach, skeletal phantom parameters are evaluated based on extensively reviewed results of published measurements of real bones. The SPSD approach allows for the assessment of both population-average values and their variability. SPSD-phantoms of the skeleton are modelled in voxel representation. They consist of smaller phantoms of the bone sites – segments – described by simple geometric shapes with uniform microarchitecture parameters. Such segmentation makes it possible to account for non-homogeneous skeletal microarchitecture and to model the bone structure with the required voxel resolution to elaborate suitable skeletal phantoms. The current study presents the parameters of the SPSD skeletal phantoms for the following age-groups: newborn, 1-year-old, 5-year-old, 10-year-old, 15-year-old (male and female), and adult (male and female). This skeletal phantom can be used for dosimetry as an alternative to available reference phantoms for bone-seeking radionuclides. The above-mentioned age- and sex-specific skeletal phantoms are comprised of 289 unique segments. The characteristics of the SPSD phantoms do not contradict published data and are in good agreement with the measurement results of real bones.

Science & Technology - Other Topics↗

Light output and neutron detection efficiency of boron-based neutron scintillator screens for neutron imaging

Recent research has explored the development of boron-based neutron scintillator screens, which potentially offer improved spatial resolution and neutron capture efficiency compared to traditional lithium-based screens. This work builds upon previous efforts to improve boron-based neutron scintillators by assessing a newer generation of boron-based scintillator screens fabricated using different compositions and fabrication approaches compared to previous generations of screens. Some of the test screens exhibit higher light output than previous efforts and higher neutron capture efficiency than lithium-based screens. This paper describes the current state of screen development, measurement results for the most recent generation of screens, and future activities.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Sulfur Species in Zinc-Rich Condylar Zones of a Rat Temporomandibular Joint

We performed synchrotron-based micro-X-ray absorption near-edge spectroscopy (µ-XANES) coupled with micro-X-ray fluorescence (µ-XRF) for the identification of elements that included biometal zinc (Zn) and nonmetal sulfur (S) (and its species) in the condylar zones of a rat temporomandibular joint (TMJ). Zone-specific spatial localization of biometal Zn and nonmetal S from a materials viewpoint when correlated with hypoxia inducible factor-1α (HIF-1α) (a surrogate for tissue oxygenation) can provide insights into Zn-specific redox pathways at the vulnerable subchondral interface. Histologic localization of Zn, HIF-1α, and sulfur-rich proteoglycans (PGs) were mapped using an optical microscope. The µ-XRF maps coupled with site-specific micro-X-ray diffraction (µ-XRD) patterns were used to underline Zn-incorporated biological apatite in the subchondral bone and the bone of a rat TMJ condyle. Results demonstrated an association between Zn, PG, and HIF-1α histologic maps with µ-XRF, µ-XANES, and µ-XRD data and provided insights into plausible biological S species in Zn-enriched zones of a rat TMJ condyle. Spatially localized Zn and S underscore their roles in cell and tissue functions in a zone-specific manner. Elemental Zn with organic and inorganic S species at the cartilage-bone interface and the biomineral phase of Zn-enriched biological apatite from subchondral bone to condylar bone were ascertained using µ-XRF-XANES and µ-XRF-XRD. The coupled µ-XRF-XANES in situ complemented with µ-XRF-XRD in situ and immunohistochemistry provided valuable biological insights into zone-specific biological pathways in rat TMJ condyles. Based on these data, we present a workflow to reliably map and correlate S species within Zn-enriched regions of cartilage, bone, and their interface. We suggest the use of this correlative and complementary microspectroscopic spatial information for zone-specific localization of biometal Zn and nonmetal S to gain insights into plausible microanatomy-specific oxidative stress in the TMJ.

apatites↗

Development of 52Mn Labeled Trastuzumab for Extended Time Point PET Imaging of HER2

Abstract Purpose Due to their long circulation time in the blood, monoclonal antibodies (mAbs) such as trastuzumab, are usually radiolabeled with long-lived positron emitters for the development of agents for Positron Emission Tomography (PET) imaging. Manganese-52 ( 52 Mn, t 1/2 = 5.6 d, β + = 29.6%, E(β ave ) = 242 keV) is suitable for imaging at longer time points providing a complementary technique to Zirconium-89 ( 89 Zr, t 1/2 = 3.3 d, β + = 22.7%, E(β ave ) = 396 keV)) because of its long half-life and low positron energy. To exploit these properties, we aimed to investigate suitable bifunctional chelators that could be readily conjugated to antibodies and labeled with 52 Mn under mild conditions using trastuzumab as a proof-of-concept. Procedures Trastuzumab was incubated with S-2-(4-isothiocyanatobenzyl)-1,4,7,10-tetraazacyclododecane tetraacetic acid (p-SCN-Bn-DOTA), 1-Oxa-4,7,10-tetraazacyclododecane-5-S-(4-isothiocyantobenzyl)-4,7,10-triacetic acid (p-SCN-Bn-Oxo-DO3A), and 3,6,9,15-tetraazabicyclo[9.3.1] pentadeca-1(15),11,13-triene-4-S-(4-isothiocyanatobenzyl)-3,6,9-triacetic acid (p-SCN-Bn-PCTA) at a tenfold molar excess. The immunoconjugates were purified, combined with [ 52 Mn]MnCl 2 at different ratios, and the labeling efficiency was assessed by iTLC. The immunoreactive fraction of the radiocomplex was determined through a Lindmo assay. Cell studies were conducted in HER2 + (BT474) and HER2- (MDA-MB-468) cell lines followed by in vivo studies. Results Trastuzumab-Oxo-DO3A was labeled within 30 min at 37 °C with a radiochemical yield (RCY) of 90 ± 1.5% and with the highest specific activity of the chelators investigated of 16.64 MBq/nmol. The labeled compound was purified with a resulting radiochemical purity of > 98% and retained a 67 ± 1.2% immunoreactivity. DOTA and PCTA immunoconjugates resulted in < 50 ± 2.5% (RCY) with similar specific activity. Mouse serum stability studies of [ 52 Mn]Mn-Oxo-DO3A-trastuzumab showed 95% intact complex for over 5 days. Cell uptake studies showed higher uptake in HER2 + (12.51 ± 0.83% /mg) cells compared to HER2- (0.85 ± 0.10%/mg) cells. PET images of mice bearing BT474 tumors showed high tumor uptake that was consistent with the biodistribution (42.02 ± 2.16%ID/g, 14 d) compared to MDA-MB-468 tumors (2.20 ± 0.80%ID/g, 14 d). Additionally, both models exhibited low bone uptake of < 1% ID/g. Conclusion The bifunctional chelator p-SCN-Bn-Oxo-DO3A is promising for the development of 52 Mn radiopharmaceuticals as it was easily conjugated, radiolabeled at mild conditions, and illustrated stability for a prolonged duration both in vitro and in vivo . High-quality PET/CT images of [ 52 Mn]Mn-Oxo-DO3A-trastuzumab were obtained 14 d post-injection. This study illustrates the potential of [ 52 Mn]Mn-Oxo-DO3A for the evaluation of antibodies using PET imaging.