Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Bone Density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Physical Activity and Bone Density in Women

A mathematical model of bone density regulation as a function of the daily tissue "effective" stress has been derived. Using the model, the influence of daily activity in the form of a daily loading history has been related to bone density of the calcaneus. The theory incorporates a stress exponent m to account for differences in the importance of magnitude and number of load cycles experienced during daily activity. We have derived a parameter from the model, the "Bone Density Index" (BDI). We have developed a method of collecting daily habitual loading histories using an insole force sensor interfaced to a portable digital data logger carried in a fanny pack. Our goal for this study was to determine a stress exponent, m, relating GRFz history to Calcaneal Bone Mineral Density (CBMD).

Bowley, Susan M.↗

Reduced vertebral bone density in hypercalciuric nephrolithiasis

Dual-energy x-ray absorptiometry and single-photon absorptiometry were used to determine bone density at the lumbar spine and radial shaft in 62 patients with absorptive hypercalciuria, 27 patients with fasting hypercalciuria, and 31 nonhypercalciuric stone formers. Lumbar bone density was significantly lower in patients with absorptive (-10%) as well as in those with fasting hypercalciuria (-12%), with 74 and 92% of patients displaying values below the normal mean, whereas only 48% of the nonhypercalciuric stone formers had bone density values below the normal mean. In contrast, radial bone density was similar in all three groups of renal stone formers investigated. The comparison of urinary chemistry in patients with absorptive hypercalciuria and low normal bone density compared to those with high normal bone density showed a significantly increased 24 h urinary calcium excretion on random diet and a trend toward a higher 24 h urinary uric acid excretion and a higher body mass index in patients with low normal bone density. Moreover, among the patients with absorptive hypercalciuria we found a statistically significant correlation between the spinal bone density and the 24 h sodium and sulfate excretion and the urinary pH. These results gave evidence for an additional role of environmental factors (sodium and animal proteins) in the pathogenesis of bone loss in absorptive hypercalciuria. In conclusion, our data suggest an osteopenia of trabecular-rich bone tissues in patients with fasting and absorptive hypercalciurias.

Non-NASA Center↗

Determinants of bone density among athletes engaged in weight-bearing and non-weight-bearing activity

The effect of weight bearing activity on the bone density was investigated in athletes by comparing the measures of bone density of athletes engaged in weight-training programs with those of polo players and nonexercising subjects. All subjects had measurements of spinal trabecular and integral bone density by quantitative tomography, as well as determinations of hip bone density by dual photon absorptiometry. Results confirmed previous findings by Block et al. (1987) of significantly greater bone density among highly trained athletes compared with nonexercising subjects of similar age. Results also indicated that athletes engaged in non-weight-bearing forms of rigorous exercise had greater levels of bone density. However, as the participants in this study were exceptional athletes, engaged in a strenuous sport with both aerobic and heavy resistance components, a confirmation of these data is needed, using larger samples of individuals.

Block, Jon E.↗

Opportunistic bone density screening for the abdominal radiologist using colored CT images: a pilot retrospective study

Purpose: The purpose of the study was to develop an accurate and reproducible method for detecting low spinal bone density on abdominal CT images. Methods: For this IRB-approved HIPAA-compliant single-center retrospective study, nonenhanced CT images of the lower abdomen were obtained in 631 African-American participants. Mean attenuation of L3/L4 was associated with quantitative CT bone density (QCT) in a randomly selected training cohort (N = 511), and receiver operating characteristics analysis was used to identify the optimal mean attenuation threshold for differentiating normal from low bone density. Custom image processing software was used to generate grayscale and colored CT images of the midline spine, with green for normal and red for low bone density. Five radiologists independently assessed bone density at L3/L4 in a validation cohort (N = 120) using various methods: QCT, visual assessment of sagittal grayscale images (Grayscale), quantitative measurement of mean attenuation on a midline sagittal image (Attenuation), and visual assessment of a midline sagittal colored image (Color). Accuracy was calculated using the average QCT bone density as a reference standard. Inter-observer agreement was assessed using intraclass correlation coefficient (ICC). Results: The optimal mean attenuation threshold for differentiating normal from low bone density at L3/L4 was 145 Hounsfield Units. The average accuracy of Grayscale, Attenuation, and Color methods was 58, 87, and 91% (p < 0.001), respectively. Inter-observer agreement was poor for Grayscale (ICC: 0.20; 95% CI 0.12, 0.28) and excellent for both Attenuation (ICC: 0.85; 95% CI 0.73, 0.91) and Color methods (ICC: 0.87; 95% CI 0.83, 0.90). Conclusion: Detection of low spinal bone density using colored abdominal CT images was highly accurate and reproducible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Instrumentation for bone density measurement

Measurement system evaluates the integrated bone density over a specific cross section of bone. A digital computer converts stored bone scan data to equivalent aluminum calibration wedge thickness, and bone density is then integrated along the scan by using the trapezoidal approximation integration formula.

Meharg, L. S.↗

Estimates of volumetric bone density from projectional measurements improve the discriminatory capability of dual X-ray absorptiometry

To determine whether estimates of volumetric bone density from projectional scans of the lumbar spine have weaker associations with height and weight and stronger associations with prevalent vertebral fractures than standard projectional bone mineral density (BMD) and bone mineral content (BMC), we obtained posteroanterior (PA) dual X-ray absorptiometry (DXA), lateral supine DXA (Hologic QDR 2000), and quantitative computed tomography (QCT, GE 9800 scanner) in 260 postmenopausal women enrolled in two trials of treatment for osteoporosis. In 223 women, all vertebral levels, i.e., L2-L4 in the DXA scan and L1-L3 in the QCT scan, could be evaluated. Fifty-five women were diagnosed as having at least one mild fracture (age 67.9 +/- 6.5 years) and 168 women did not have any fractures (age 62.3 +/- 6.9 years). We derived three estimates of "volumetric bone density" from PA DXA (BMAD, BMAD*, and BMD*) and three from paired PA and lateral DXA (WA BMD, WA BMDHol, and eVBMD). While PA BMC and PA BMD were significantly correlated with height (r = 0.49 and r = 0.28) or weight (r = 0.38 and r = 0.37), QCT and the volumetric bone density estimates from paired PA and lateral scans were not (r = -0.083 to r = 0.050). BMAD, BMAD*, and BMD* correlated with weight but not height. The associations with vertebral fracture were stronger for QCT (odds ratio [QR] = 3.17; 95% confidence interval [CI] = 1.90-5.27), eVBMD (OR = 2.87; CI 1.80-4.57), WA BMDHol (OR = 2.86; CI 1.80-4.55) and WA-BMD (OR = 2.77; CI 1.75-4.39) than for BMAD*/BMD* (OR = 2.03; CI 1.32-3.12), BMAD (OR = 1.68; CI 1.14-2.48), lateral BMD (OR = 1.88; CI 1.28-2.77), standard PA BMD (OR = 1.47; CI 1.02-2.13) or PA BMC (OR = 1.22; CI 0.86-1.74). The areas under the receiver operating characteristic (ROC) curves for QCT and all estimates of volumetric BMD were significantly higher compared with standard PA BMD and PA BMC. We conclude that, like QCT, estimates of volumetric bone density from paired PA and lateral scans are unaffected by height and weight and are more strongly associated with vertebral fracture than standard PA BMD or BMC, or estimates of volumetric density that are solely based on PA DXA scans.

Non-NASA Center↗

Axial and appendicular bone density predict fractures in older women

To determine whether measurement of hip and spine bone mass by dual-energy x-ray absorptiometry (DEXA) predicts fractures in women and to compare the predictive value of DEXA with that of single-photon absorptiometry (SPA) of appendicular sites, we prospectively studied 8134 nonblack women age 65 years and older who had both DEXA and SPA measurements of bone mass. A total of 208 nonspine fractures, including 37 wrist fractures, occurred during the follow-up period, which averaged 0.7 years. The risk of fracture was inversely related to bone density at all measurement sites. After adjusting for age, the relative risks per decrease of 1 standard deviation in bone density for the occurrence of any fracture was 1.40 for measurement at the proximal femur (95% confidence interval 1.20-1.63) and 1.35 (1.15-1.58) for measurement at the spine. Results were similar for all regions of the proximal femur as well as SPA measurements at the calcaneus, distal radius, and proximal radius. None of these measurements was a significantly better predictor of fractures than the others. Furthermore, measurement of the distal radius was not a better predictor of wrist fracture (relative risk 1.64: 95% CI 1.13-2.37) than other sites, such as the lumbar spine (RR 1.56; CI 1.07-2.26), the femoral neck (RR 1.65; CI 1.12-2.41), or the calcaneus (RR 1.83; CI 1.26-2.64). We conclude that the inverse relationship between bone mass and risk of fracture in older women is similar for absorptiometric measurements made at the hip, spine, and appendicular sites.

Multicenter Study↗

Persistent organic pollutants, skull size and bone density of polar bears (Ursus maritimus) from East Greenland 1892–2015 and Svalbard 1964–2004

Highlights: • Density in East Greenland males decreased over time. • Size in East Greenland females tented to decrease over time. • Size was highest in Svalbard polar bears. • Density was positive correlated to POPs. • Environmental changes and POPs may affect bone density and size. We investigated skull size (condylobasal length; CBL) and bone mineral density (BMD) in polar bears (Ursus maritimus) from East Greenland (n = 307) and Svalbard (n = 173) sampled during the period 1892–2015 in East Greenland and 1964–2004 at Svalbard. Adult males from East Greenland showed a continuous decrease in BMD from 1892 to 2015 (linear regression: p < 0.01) indicating that adult male skulls collected in the early pre-pollution period had the highest BMD. A similar decrease in BMD over time was not found for the East Greenland adult females. However, there was a non-significant trend that the skull size of adult East Greenland females was negatively correlated with collection year 1892–2015 (linear regression: p = 0.06). No temporal change was found for BMD or skull size in Svalbard polar bears (ANOVA: all p > 0.05) nor was there any significant difference in BMD between Svalbard and East Greenland subpopulations. Skull size was larger in polar bears from Svalbard than from East Greenland (two-way ANOVA: p = 0.003). T-scores reflecting risk of osteoporosis showed that adult males from both East Greenland and Svalbard are at risk of developing osteopenia. Finally, when correcting for age and sex, BMD in East Greenland polar bears increased with increasing concentrations of persistent organic pollutants (POPs) i.e. ΣPCB (polychlorinated biphenyls), ΣHCH (hexachlorohexane), HCB (hexachlorobenzene) and ΣPBDE (polybrominated diphenyl ethers) while skull size increased with ΣHCH concentrations all in the period 1999–2014 (multiple linear regression: all p < 0.05, n = 175). The results suggest that environmental changes over time, including exposure to POPs, may affect bone density and size of polar bears.

54 ENVIRONMENTAL SCIENCES↗

Accurate Measurement of Bone Density with QCT

The objective of this study was to determine the accuracy of bone density measurement with a new OCT technology. A phantom was fabricated using two materials, a water-equivalent compound and hydroxyapatite (HA), combined in precise proportions (QRM GrnbH, Germany). The phantom was designed to have the approximate physical size and range in bone density as a human calcaneus, with regions of 0, 50, 100, 200, 400, and 800 mg/cc HA. The phantom was scanned at 80, 120 and 140 KVp with a GE CT/i HiSpeed Advantage scanner. A ring of highly attenuating material (polyvinyl chloride or teflon) was slipped over the phantom to alter the image by introducing non-axi-symmetric beam hardening. Images were corrected with a new OCT technology using an estimate of the effective X-ray beam spectrum to eliminate beam hardening artifacts. The algorithm computes the volume fraction of HA and water-equivalent matrix in each voxel. We found excellent agreement between expected and computed HA volume fractions. Results were insensitive to beam hardening ring material, HA concentration, and scan voltage settings. Data from all 3 voltages with a best fit linear regression are displays.

Cleek, Tammy M.↗

Bone Density Changes After Radiation for Extremity Sarcomas: Exploring the Etiology of Pathologic Fractures

Purpose: The incidental irradiation (RT) of adjacent bone that takes place during treatment of soft tissue extremity sarcomas is generally presumed to 'weaken' the bone by decreasing its density, which subsequently increases the risk for pathologic fracture. This investigation intended to assess the relative effects on bone density of both RT and diminished mechanical loading secondary to tumor-induced and therapy-induced functional extremity impairment. Methods and Materials: 19 patients treated with surgical excision and RT for soft tissue extremity sarcomas had bone density measured using dual energy X-ray absorptiometry at four sites: the irradiated (A) and contralateral (B) bone, and an uninvolved bone (C) in the treated extremity and its contralateral counterpart (D). Analysis included (1) [A-B], (2) [C-D], (3) [(A-B), - (C-D)], and (4) [(A-B)/B - (C-D)/D]. Results: The mean bone density for all irradiated sites was increased 0.08 {+-} 0.22 g/cm{sup 2} (variance) compared to the contralateral unirradiated side when corrected for weight-bearing effects (3). An average increase in bone density of 9 {+-} 22% (p = 0.08) was also seen when the differences were divided by individual control densities to normalize variation in density of different anatomic sites (4). Conclusions: RT does not routinely decrease bone density when corrected for weight bearing or mechanical effects. The pathogenesis for the known increased risk of pathologic fracture in irradiated bones is likely multifactorial, including possible alterations in bone remodeling that can result in stable, or even increased, bone density. Further clinical and basic studies are needed to confirm our unexpected findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Serial Scanning and Registration of High Resolution Quantitative Computed Tomography Volume Scans for the Determination of Local Bone Density Changes

Progress in development of the methods required to study bone remodeling as a function of time is reported. The following topics are presented: 'A New Methodology for Registration Accuracy Evaluation', 'Registration of Serial Skeletal Images for Accurately Measuring Changes in Bone Density', and 'Precise and Accurate Gold Standard for Multimodality and Serial Registration Method Evaluations.'

Whalen, Robert T.↗

The effects of low environmental cadmium exposure on bone density

Recent epidemiological data indicate that low environmental exposure to cadmium, as shown by cadmium body burden (Cd-U), is associated with renal dysfunction as well as an increased risk of cadmium-induced bone disorders. The present study was designed to assess the effects of low environmental cadmium exposure, at the level sufficient to induce kidney damage, on bone metabolism and mineral density (BMD). The project was conducted in the area contaminated with cadmium, nearby a zinc smelter located in the region of Poland where heavy industry prevails. The study population comprised 170 women (mean age=39.7; 18-70 years) and 100 men (mean age=31.9; 18-76 years). Urinary and blood cadmium and the markers of renal tubular dysfunction ({beta}{sub 2}M-U RBP, NAG), glomerular dysfunction (Alb-U and {beta}{sub 2}M-S) and bone metabolism markers (BAP-S, CTX-S) as well as forearm BMD, were measured. The results of this study based on simple dose-effect analysis showed the relationship between increasing cadmium concentrations and an increased excretion of renal dysfunction markers and decreasing bone density. However, the results of the multivariate analysis did not indicate the association between exposure to cadmium and decrease in bone density. They showed that the most important factors that have impact on bone density are body weight and age in the female subjects and body weight and calcium excretion in males. Our investigation revealed that the excretion of low molecular weight proteins occurred at a lower level of cadmium exposure than the possible loss of bone mass. It seems that renal tubular markers are the most sensitive and significant indicators of early health effects of cadmium intoxication in the general population. The correlation of urinary cadmium concentration with markers of kidney dysfunction was observed in the absence of significant correlations with bone effects. Our findings did not indicate any effects of environmental cadmium exposure on bone density.

60 APPLIED LIFE SCIENCES↗