At least 19 records

A non-intrusive framework using acoustic signals and deep learning for boiling diagnostics in visual-limited environments

Accurate monitoring of boiling heat transfer is critical for safeguarding high-power systems operating in environments where conventional optical diagnostics are hindered by radiation fields or restricted visual accessibility. This study presents a non-intrusive framework that integrates hydroacoustic sensing with deep learning to infer near-wall boiling characteristics and enable predictive thermal assessment without visual access. In a prototypical subcooled flow-boiling facility representative of the Isotope Production Facility (IPF) at Los Alamos, hydrophones capture boiling-induced acoustic emissions that are transformed into background-removed Short-Time Fourier Transform (STFT) spectrograms. A convolutional neural network (CNN) then regresses heat flux, wall superheat, and key bubble parameters directly from these spectrograms. The CNN achieved predictive accuracy under nominal conditions and demonstrated robustness and generalization under acoustic noise for Signal-to-Noise Ratios (SNRs) down to approximately 0 dB. When integrated into an ANSYS CFX wall-boiling model, the acoustically inferred parameters reproduced boiling curve and critical heat flux (CHF) values consistent with image-based benchmarks. Furthermore, the model retained reliable performance under moderate variations in bulk temperature, flow rate, and hydrophone placement, confirming its generalizability across practical boundary conditions. These results demonstrate the feasibility of hydroacoustic-based deep learning as a viable path toward real-time, radiation-tolerant boiling diagnostics and predictive thermal safety assessment in inaccessible systems such as the IPF.

42 ENGINEERING↗

Acoustic Bubble Removal from Boiling Surfaces

The object of the study was the investigation of the forces generated by standing acoustic waves on vapor bubbles, both far and near boundaries. In order to accomplish this objective, in view of the scarcity of publications on the topic, it has been necessary to build an edifice of knowledge about vapor bubbles in sound and flow fields from the ground up, as it were. We have addressed problems of gradually greater difficulty as follows: 1. In the first place, the physics of an stationary isolated bubble subject to a sound field in an unbounded liquid was addressed; 2. The case of bubbles translating in a stationary pressure field was then considered; 3. This was followed by a study of the combined effects of sound and translation, 4. And of a neighboring boundary 5. Finally, a new method to deal with nonspherical bubbles was developed- In addition to the work on vapor bubbles, some studies on gas bubbles were conducted in view of NASA's interest in the phenomenon of sonoluminescence.

Prosperetti, Andrea↗

The Dynamics of Vapor Bubbles in Acoustic Pressure Fields

In spite of a superficial similarity with gas bubbles, the intimate coupling between dynamical and thermal processes confers to oscillating vapor bubbles some unique characteristics. This paper examines numerically the validity of some asymptotic-theory predictions such as the existence of two resonant radii and a limit size for a given sound amplitude and frequency. It is found that a small vapor bubble in a sound field of sufficient amplitude grows quickly through resonance and continues to grow thereafter at a very slow rate, seemingly indefinitely. Resonance phenomena therefore play a role for a few cycles at most, and reaching a limit size-if one exists at all-is found to require far more than several tens of thousands of cycles. It is also found that some small bubbles may grow or collapse depending on the phase of the sound field. The model accounts in detail for the thermo-fluid-mechanic processes in the vapor. In the second part of the paper, an approximate formulation valid for bubbles small with respect to the thermal penetration length in the vapor is derived and its accuracy examined, The present findings have implications for acoustically enhanced boiling heat transfer and other special applications such as boiling in microgravity.

Hao, Y.↗

Bubble Dynamics, Two-Phase Flow, and Boiling Heat Transfer in Microgravity

This report contains two independent sections. Part one is titled "Terrestrial and Microgravity Pool Boiling Heat Transfer and Critical heat flux phenomenon in an acoustic standing wave." Terrestrial and microgravity pool boiling heat transfer experiments were performed in the presence of a standing acoustic wave from a platinum wire resistance heater using degassed FC-72 Fluorinert liquid. The sound wave was created by driving a half wavelength resonator at a frequency of 10.15 kHz. Microgravity conditions were created using the 2.1 second drop tower on the campus of Washington State University. Burnout of the heater wire, often encountered with heat flux controlled systems, was avoided by using a constant temperature controller to regulate the heater wire temperature. The amplitude of the acoustic standing wave was increased from 28 kPa to over 70 kPa and these pressure measurements were made using a hydrophone fabricated with a small piezoelectric ceramic. Cavitation incurred during experiments at higher acoustic amplitudes contributed to the vapor bubble dynamics and heat transfer. The heater wire was positioned at three different locations within the acoustic field: the acoustic node, antinode, and halfway between these locations. Complete boiling curves are presented to show how the applied acoustic field enhanced boiling heat transfer and increased critical heat flux in microgravity and terrestrial environments. Video images provide information on the interaction between the vapor bubbles and the acoustic field. Part two is titled, "Design and qualification of a microscale heater array for use in boiling heat transfer." This part is summarized herein. Boiling heat transfer is an efficient means of heat transfer because a large amount of heat can be removed from a surface using a relatively small temperature difference between the surface and the bulk liquid. However, the mechanisms that govern boiling heat transfer are not well understood. Measurements of wall temperature and heat flux near the wall would add to the database of knowledge which is necessary to understand the mechanisms of nucleate boiling. A heater array has been developed which contains 96 heater elements within a 2.5 mm square area. The temperature of each heater element is held constant by an electronic control system similar to a hot-wire anemometer. The voltage that is being applied to each heater element can be measured and digitized using a high-speed Analog to Digital (A/D) converter, and this digital information can be compiled into a series of heat-flux maps. Information for up to 10,000 heat flux maps can be obtained each second. The heater control system, the A/D system and the heater array construction are described in detail. Results are presented which show that this is an effective method of measuring the local heat flux during nucleate and transition boiling. Heat flux maps are obtained for pool boiling in FC-72 on a horizontal surface. Local heat flux variations are shown to be three to six times larger than variations in the spatially averaged heat flux.

Chung, Jacob N.↗

Vaporizable endoskeletal droplets via tunable interfacial melting transitions

Liquid emulsion droplet evaporation is of importance for various sensing and imaging applications. The liquid-to-gas phase transformation is typically triggered thermally or acoustically by low–boiling point liquids, or by inclusion of solid structures that pin the vapor/liquid contact line to facilitate heterogeneous nucleation. However, these approaches lack precise tunability in vaporization behavior. Here, we describe a previously unused approach to control vaporization behavior through an endoskeleton that can melt and blend into the liquid core to either enhance or disrupt cohesive intermolecular forces. This effect is demonstrated using perfluoropentane (C 5 F 12 ) droplets encapsulating a fluorocarbon (FC) or hydrocarbon (HC) endoskeleton. FC skeletons inhibit vaporization, whereas HC skeletons trigger vaporization near the rotator melting transition. Our findings highlight the importance of skeletal interfacial mixing for initiating droplet vaporization. Tuning molecular interactions between the endoskeleton and droplet phase is generalizable for achieving emulsion or other secondary phase transitions, in emulsions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bubble dynamics, two-phase flow, and boiling heat transfer in a microgravity environment

The two-phase bubbly flow and boiling heat transfer in microgravity represents a substantial challenge to scientists and engineers and yet there is an urgent need to seek fundamental understanding in this area for future spacecraft design and space missions. At Washington State University, we have successfully designed, built and tested a 2.1 second drop tower with an innovation airbag deceleration system. Microgravity boiling experiments performed in our 0.6 second Drop Tower produced data flow visualizations that agree with published results and also provide some new understanding concerning flow boiling and microgravity bubble behavior. On the analytical and numerical work, the edge effects of finite divergent electrode plates on the forces experienced by bubbles were investigated. Boiling in a concentric cylinder microgravity and an electric field was numerically predicted. We also completed a feasibility study for microgravity boiling in an acoustic field.

Chung, Jacob N.↗

Acoustic Insights into Flow Condensation Mechanisms

Two-phase thermal management systems, with both boiling and condensation processes, offer great potential and heat transfer coefficients that are orders of magnitude higher than traditional single-phase systems. However, two-phase flows can suffer from a wide range of interfacial instabilities leading to significant thermal performance degradation. In this study, we aim to detect regime transitions and characterize dominating physical mechanisms of flow condensation, such as turbulent diffusion in annular liquid film and interfacial waves, using an integrated system of acoustic, modal, and optical sensing techniques and thermofluidic characterizations. A wideband acoustic emissions sensor and high-sensitivity accelerometer are utilized to capture acoustic and vibrational signatures that signal the onset of liquid film formation and interfacial waves during flow pattern transitions. Compared to optical imaging, wideband acoustic emission sensing allows for higher sampling rates to capture high-frequency interface oscillations critical to the flow regime transitions and works well even for condensation in opaque tubes. Acoustic features (e.g., amplitude, frequency, energy, duration) are correlated with thermofluidic processes (e.g., capillary flows, turbulent flows, boiling, condensation). By relating thermal performance metrics with these dynamic signatures in acoustic and modal regimes, we explore the ability to probe and monitor critical flow regime transitions and transport efficiency in flow condensation.

Acoustic Modal Regimes↗

Bubble Dynamics, Two-Phase Flow, and Boiling Heat Transfer in Microgravity

The objective of the research is to study the feasibility of employing an external force to replace the buoyancy force in order to maintain nucleate boiling in microgravity. We have found that a bulk velocity field, an electric field and an acoustic field could each play the role of the gravity field in microgravity. Nucleate boiling could be maintained by any one of the three external force fields in space.

Chung, Jacob N.↗

Acoustic and Thermal Testing of an Integrated Multilayer Insulation and Broad Area Cooling Shield System

A Multilayer Insulation (MLI) and Broad Area Cooling (BAC) shield thermal control system shows promise for long-duration storage of cryogenic propellant. The NASA Cryogenic Propellant Storage and Transfer (CPST) project is investigating the thermal and structural performance of this tank-applied integrated system. The MLI/BAC Shield Acoustic and Thermal Test was performed to evaluate the MLI/BAC shield's structural performance by subjecting it to worst-case launch acoustic loads. Identical thermal tests using Liquid Nitrogen (LN2) were performed before and after the acoustic test. The data from these tests was compared to determine if any degradation occurred in the thermal performance of the system as a result of exposure to the acoustic loads. The thermal test series consisted of two primary components: a passive boil-off test to evaluate the MLI performance and an active cooling test to evaluate the integrated MLI/BAC shield system with chilled vapor circulating through the BAC shield tubes. The acoustic test used loads closely matching the worst-case envelope of all launch vehicles currently under consideration for CPST. Acoustic test results yielded reasonable responses for the given load. The thermal test matrix was completed prior to the acoustic test and successfully repeated after the acoustic test. Data was compared and yielded near identical results, indicating that the MLI/BAC shield configuration tested in this series is an option for structurally implementing this thermal control system concept.

Wood, J. J.↗

Acoustic and Thermal Testing of an Integrated Multilayer Insulation and Broad Area Cooling Shield System

A Multilayer Insulation (MLI) and Broad Area Cooling (BAC) shield thermal control system shows promise for long-duration storage of cryogenic propellant. The NASA Cryogenic Propellant Storage and Transfer (CPST) project is investigating the thermal and structural performance of this tank-applied integrated system. The MLI/BAC Shield Acoustic and Thermal Test was performed to evaluate the MLI/BAC shield's structural performance by subjecting it to worst-case launch acoustic loads. Identical thermal tests using Liquid Nitrogen (LN2) were performed before and after the acoustic test. The data from these tests was compared to determine if any degradation occurred in the thermal performance of the system as a result of exposure to the acoustic loads. The thermal test series consisted of two primary components: a passive boil-off test to evaluate the MLI performance and an active cooling test to evaluate the integrated MLI/BAC shield system with chilled vapor circulating through the BAC shield tubes. The acoustic test used loads closely matching the worst-case envelope of all launch vehicles currently under consideration for CPST. Acoustic test results yielded reasonable responses for the given load. The thermal test matrix was completed prior to the acoustic test and successfully repeated after the acoustic test. Data was compared and yielded near identical results, indicating that the MLI/BAC shield configuration tested in this series is an option for structurally implementing this thermal control system concept.

Wood, Jessica J.↗

Acoustic Behavior of Vapor Bubbles

In a microgravity environment vapor bubbles generated at a boiling surface tend to remain near it for a long time. This affects the boiling heat transfer and in particular promotes an early transition to the highly inefficient film boiling regime. This paper describes the physical basis underlying attempts to remove the bubbles by means of pressure radiation forces.

Prosperetti, Andrea↗

RECLAIM: Electrochemical Lithium and Nickel Extraction with Concurrent Carbon Dioxide Mineralization

This project aims to develop technologies toward the production of Li and Ni from CO 2 -reactive minerals and rocks that contain Ca and Mg, while sequestering CO 2 . The technologies include acoustic stimulation and electrolytic proton production, which use electricity to liberate valuable metal ions from the surrounding mineral matrix at sub-boiling temperatures (~20-80°C). Feedstocks include Li/Ni/Ca/Mg-rich igneous and sedimentary rocks and minerals such as holmquistite, hectorite, lateritic Ni ores enriched in Mg-rich serpentine. Other examples of feedstocks that could be used include coarse grained orthocumulate, mine tailings, etc. In the first step, the electrolytic breakdown of water to H + and OH – (as well as O 2 and H 2 ) will be induced by applying an electric potential to simultaneously produce acidity and alkalinity. The solid feedstocks will be dissolved in the acidic anolyte under acoustic stimulation. Solubilized species will then undergo separation using our unique Li + -selective membranes driven by electrodialysis, leading to concentration of Li as soluble lithium silicate, from which Li 2 CO 3 can be derived by reaction with CO 2(g) while supplying cathode alkalinity. Also at the cathode, stepwise electrolytic precipitation of metal hydroxides, including Ni(OH) 2 , Ca(OH) 2 , and Mg(OH) 2 is performed along a cascade reactor in which both the applied potential and pH increase downstream, thereby simultaneously extracting and separating the metals. Finally, exposure of Ca(OH) 2 and Mg(OH) 2 to dilute CO 2 will result in CO 2 uptake in the form of Ca and Mg carbonates. The primary accomplishments include sample procurement and characterization. Progress has been made on precursor identification and mapping, establishing protocols for assessing metal extractability under sonication, and preliminary technoeconomic analysis (TEA) and life cycle analysis (LCA).

36 MATERIALS SCIENCE↗

Thermal Acoustic Oscillation: Causes, Detection, Analysis, and Prevention

Thermal Acoustic Oscillations (TAO) can occur in cryogenic systems and produce significant sources of heat. This source of heat can increase the boil off rate of cryogenic propellants in spacecraft storage tanks and reduce mission life. This paper discusses the causes of TAO, how it can be detected, what analyses can be done to predict it, and how to prevent it from occurring.The paper provides practical insight into what can aggravate instability, practical methods for mitigation, and when TAO does not occur. A real life example of a cryogenic system with an unexpected heat source is discussed, along with how TAO was confirmed and eliminated.

Cryogenics↗

Model of a Piezoelectric Transducer

It's difficult to control liquid and gas in propellant tanks in zero gravity. A possible a design would utilize acoustic liquid manipulation (ALM) technology which uses ultrasonic beams conducted through a liquid and solid media, to push gas bubbles in the liquid to desirable locations. We can propel and control the bubble with acoustic radiation pressure by aiming the acoustic waves on the bubble s surface. This allows us to design a so called smart tank in which the ALM devices transfer the gas to the outer wall of the tank and isolating the liquid in the center. Because the heat transfer rate of a gas is lower of that of the liquid it would substantially decrease boil off and provide of for a longer storage life. The ALM beam is composed of little wavelets which are individual waves that constructively interfere with each other to produce a single, combined acoustic wave front. This is accomplished by using a set of synchronized ultrasound transducers arranged in an array. A slight phase offset of these elements allows us to focus and steer the beam. The device that we are using to produce the acoustic beam is called the piezoelectric transducer. This device converts electrical energy to mechanical energy, which appears in the form of acoustic energy. Therefore the behavior of the device is dependent on both the mechanical characteristics, such as its density, cross-sectional area, and its electrical characteristics, such as, electric flux permittivity and coupling factor. These devices can also be set up in a number of modes which are determined by the way the piezoelectric device is arranged, and the shape of the transducer. For this application we are using the longitudinal or thickness mode for our operation. The transducer also vibrates in the lateral mode, and one of the goals of my project is to decrease the amount of energy lost to the lateral mode. To model the behavior of the transducers I will be using Pspice, electric circuit modeling tool, to determine the transducer's electrical characteristics at the frequency of interest. This will also help me determine the characteristics of an impedance matching network to operate the transducer at its optimum efficiency. For this I will use ABMs (analog behavioral modeling) to model dependent current and voltage sources that represent the transducer. I have also been working on the Labview control software for the phased array used to control the bubbles, and will begin testing on that before the end of my internship.

Goodenow, Debra↗

Demonstration of Multilayer Insulation, Vapor Cooling of Structure, and Mass Gauging for Large Scale Upper Stages: Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) Final Report

Testing was completed on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) between August 2019 and January 2020. SHIIVER was designed to be a test bed for the scaling of cryogenic fluid management technologies as applied to large upper stages and long duration in-space stages. The hardware consists of a 4 meter diameter stainless steel tank, structural skirts supporting the tank in the aft direction, and an aluminum forward skirt with vapor cooling channels bolted to it. The initial testing of the SHIIVER hardware was with liquid hydrogen and liquid nitrogen (as a substitute fluid for liquid oxygen and liquid methane) and sought to demonstrate the use of boil-off vapor to intercept heat on a structural skirt, multilayer insulation (MLI) on the tank domes, and the radio frequency mass gauge (RFMG). Testing was completed in four stages: a baseline thermal vacuum test prior to installation of the MLI, a thermal vacuum test after the MLI installation, a reverberant acoustic test, and a subsequent thermal vacuum test to verify that no damage occurred during the reverberant acoustic testing. Each thermal vacuum test with chamber wall at ambient temperature and vacuum level in the 10-6 torr range was conducted continuously between approximately 90% full and 25% full. Test results showed that the vapor cooling reduced the heat load to the tank by approximately 10%, but the boil-off by less than 3% at 50% full with no MLI on the domes. It reduced the heat load to the tank by approximately 10%, but the boil-off was essentially unchanged at 50% full whether or not vapor cooling was operational with MLI on the domes. The MLI reduced the heat load to the tank by approximately 40% at all fill levels, but the boil-off by approximately 25% at 90% full and 45% below 65% full. The RFMG performed well over all fill ranges, and several RF tank modes were used to gauge the mass of fluid in the tank. SHIIVER was then exposed to an acoustic environment of 147 dB OASPL (overall sound pressure level) in a reverberant chamber. The acoustic environment and profile envelopes the upper stage internal acoustic level of several different modern launch vehicles. No structural or thermal performance changes were observed as a result of acoustic testing. Final thermal vacuum testing after the acoustic testing showed no degradation to the MLI due to the acoustic environment as measured via system heat loads.

SHIIVER↗

Summary of Testing Results for the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER)

Testing was completed on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) between August 2019 and January 2020. SHIIVER was designed to be a test bed for the scaling of cryogenic fluid management technologies as applied to large upper stages and long duration in-space stages. The baseline SHIIVER design consists of uninsulated structural skirts attached to a propellant tank insulated with polyurethane Spray-On Foam Insulation (SOFI). The initial testing of the SHIIVER hardware was with liquid hydrogen and sought to demonstrate the use of boil-off vapor to intercept heat on a structural skirt, multilayer insulation (MLI) on the tank domes, and the radio frequency mass gauge (RFMG). Testing was completed in four stages: a baseline thermal vacuum test prior to installation of the MLI on the tank domes, a thermal vacuum test after the MLI installation, a reverberant acoustic test, and a subsequent thermal vacuum test to verify that no damage occurred during the reverberant acoustic testing. Each thermal vacuum test with chamber wall at ambient temperature and vacuum level in the 10-6 torr range was conducted continuously between approximately 90% full and 25% full. Test results showed that the vapor cooling reduced the heat load to the tank by approximately 10%, but the boil-off by less than 3% at 50% full, with and without MLI installed on the domes. The MLI installed on the domes reduced the heat load to the tank by approximately 40% at all fill levels, but the boil-off by approximately 25% at 90% full and 45% below 65% full. The RFMG performed well over all fill ranges, and several RF tank modes were used to gauge the mass of fluid in the tank. SHIIVER was then exposed to an acoustic environment of 147 dB OASPL (overall sound pressure level) in a reverberant chamber. The acoustic environment envelopes the upper stage internal acoustic level of several different modern launch vehicles. No structural or thermal performance changes were observed after exposure to the acoustic environment. Final thermal vacuum testing after the acoustic testing showed no degradation to the MLI due to the acoustic environment as measured via system heat loads

SHIIVER↗

An Overview of Recent Cryogenic Fluid Management Developments

Long-term storage, supply, and transfer of cryogenic fluids are critical capabilities needed to advance the human exploration of space. Technologies and advanced development programs have been pursued to address issues likely to confront the designers and developers of future cryogenic fluid management (CFM) subsystems and propulsion systems. NASA and aerospace industries have continued to conduct research and development for the propulsion applications of cryogenic fluids. From the well known in-space applications, to new applications involving superconducting motors within multiple different aircraft, and a renewed interest in production of oxygen on Mars, NASA continues to probe cryogenic applications within propulsion. This article presents brief reviews of several of the current CFM efforts to support future space missions. NASA GRC is currently focusing on understanding some of the finer points in the application of multilayer insulation. GRC recently finished the activation of a new calorimeter that operates at 20 K with a warm boundary that can operate either around 90 K or at 300 K. Current testing is focused on investigating multiple different seam concepts, initially between temperatures of 300 K and 20 K, and between 20 K and 90 K. One of the larger recent NASA investments has been on the Structural Heat Intercept, Insulation, and Vibration Experiment Rig (SHIIVER). SHIIVER is a 4 m diameter tank that is approximately 1/2 scale of the planned upper stage of the new Space Launch System (SLS) rocket. SHIIVER is focused on demonstrating the thermal benefits of multilayer insulation on the tank domes and boil-off vapor cooling on structural cylinders that hold the tank in-line on the rocket. It will also quantify any damage that may incur during the acoustic environment of over 160 decibels that SLS will experience on its trip to Earth orbit. In support of the possible production of oxygen out of the Mars' atmosphere, a team comprised of four NASA centers (GRC, MSFC, JSC, and KSC) collaborated to investigate multiple different hardware combinations, refrigeration cycles, and integration techniques to minimize power and mass of the storage and liquefaction system. Moreover, high efficiency, high capacity cryocoolers are an element of CFM which is essential for achieving NASA's future long duration missions. Currently in development is a 20W at 20K unit for use with liquid hydrogen. It is scheduled for delivery to NASA in the summer of 2017. Two Phase I SBIRS have recently concluded resulting in the preliminary design of two different 90K units, each having a refrigeration capacity of approximately 150W. Once the development efforts are complete, these high capacity 90K units will be integrated into the design of NASA's Liquid Oxygen (LOX)/Methane applications such as the Lander and Ascent Vehicles, or possibly an in-space stage. CFM technology is critical to the success of missions to Mars, Planetary Exploration, and In-Situ Resource Utilization (ISRU) for cryogenic propellant production. NASA is focusing on the development of CFM technologies needed to provide necessary data and relevant experience to support informed decisions on implementation of design of cryogenic systems for long term space missions. Lessons learned from the described CFM developments would lead to enhanced safety and reliability and enabling technologies which could allow NASA to meet future space exploration goals.

Hedayat, A.↗