Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Body Temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Relationship between alertness, performance, and body temperature in humans

Body temperature has been reported to influence human performance. Performance is reported to be better when body temperature is high/near its circadian peak and worse when body temperature is low/near its circadian minimum. We assessed whether this relationship between performance and body temperature reflects the regulation of both the internal biological timekeeping system and/or the influence of body temperature on performance independent of circadian phase. Fourteen subjects participated in a forced desynchrony protocol allowing assessment of the relationship between body temperature and performance while controlling for circadian phase and hours awake. Most neurobehavioral measures varied as a function of internal biological time and duration of wakefulness. A number of performance measures were better when body temperature was elevated, including working memory, subjective alertness, visual attention, and the slowest 10% of reaction times. These findings demonstrate that an increased body temperature, associated with and independent of internal biological time, is correlated with improved performance and alertness. These results support the hypothesis that body temperature modulates neurobehavioral function in humans.

Non-NASA Center

Primate body temperature and sleep responses to lower body positive pressure

Cephalic fluid shifts, induced by lower body positive pressure (LBPP) are known to influence various physiological systems (i.e., cardiovascular and renal). In earlier experiments, an apparent change in the arousal state of primates in such LBPP conditions was observed. This study was designed to examine the effects of LBPP on arousal state and body temperature level which is normally correlated with sleep. Chair-restrained male squirrel monkeys were exposed to 40 mmHg LBPP for 90-100 minutes between the daytime hours of 13:00-15:00. Each monkey was placed in a specially modified restraint chair to which they were highly trained. Deep body temperature (DBT) was collected from 10 animals. Sleep parameters were obtained from six animals chronically implanted for sleep recording. A video camera was used to observe each animal's apparent state of arousal. LBPP resulted in an approximate 0.9 C decrease in DBT. During video observation, some animals appeared drowsy during LBPP; however, sleep recording revealed no significant changes in the state of arousal. Thus, LBPP is capable of inducing a mild hyperthermia. Further, the mechanisms underlying the observed lowering of body temperature appear to be independent of arousal state.

Edgar, D. M.

Light masking of circadian rhythms of heat production, heat loss, and body temperature in squirrel monkeys

Whole body heat production (HP) and heat loss (HL) were examined to determine their relative contributions to light masking of the circadian rhythm in body temperature (Tb). Squirrel monkey metabolism (n = 6) was monitored by both indirect and direct calorimetry, with telemetered measurement of body temperature and activity. Feeding was also measured. Responses to an entraining light-dark (LD) cycle (LD 12:12) and a masking LD cycle (LD 2:2) were compared. HP and HL contributed to both the daily rhythm and the masking changes in Tb. All variables showed phase-dependent masking responses. Masking transients at L or D transitions were generally greater during subjective day; however, L masking resulted in sustained elevation of Tb, HP, and HL during subjective night. Parallel, apparently compensatory, changes of HL and HP suggest action by both the circadian timing system and light masking on Tb set point. Furthermore, transient HL increases during subjective night suggest that gain change may supplement set point regulation of Tb.

Non-NASA Center

Influence of exposure to a prolonged hyperdynamic field on body temperature in the squirrel monkey

The effect of gravitational loading on the regulation of body temperature is examined. Five adult male squirrel monkeys were exposed to a 2-G environment twice for 48 hours, once beginning in the middle of their light cycle and the second time in the middle of their dark cycle. It is observed that a reduction in body temperature occurs during the light cycle phase and at night there is an insignificant change in body temperature. The rhythmic characteristics of the light and dark cycles are analyzed. The data reveal that the body temperature in animals at 2 G is influenced more during the active phase of the animals 24-hour cycle.

Fuller, C. A.

Body temperature measuring system (M171)

The body temperature probe is used in support of experiment M171 to determine if crewmen are storing heat following exercise and to monitor crew health in case of illness.

Lem, J. D.

Deep-body temperature changes in rats exposed to chronic centrifugation.

Deep-body temperature was monitored continuously by implant biotelemetry in unrestrained rats before, during, and after exposure to prolonged and almost continuous centrifugation. Rats subjected to centrifugation for the first time at various G loads ranging up to 2.5 G show a rapid and significant fall in temperature which is sustained below normal levels for periods as long as 3 days. The magnitude of the temperature fall and the recovery time were generally proportional to the G load imposed. The initial fall and recovery of body temperature closely parallels the decrease in food consumption and to a lesser degree the decrease in body mass experienced by centrifuged rats. After exposure to 2 weeks of centrifugation, rats show either no change or only a small transient increase in temperature when decelerated to a lower G level or when returned to normal gravity. Rats repeatedly exposed to centrifugation consistently showed a smaller temperature response compared to the initial exposure. Implant temperature biotelemetry has been found to be a sensitive, reliable, and extremely useful technique for assessing the initial stress of centrifugation and in monitoring the time course of recovery and acclimation of rats to increase as well as*decrease G.

Oyama, J.

Core Body Temperature Predictions Using Metabolic Energy Expenditure and Heart Rate During Simulated Extravehicular Activity

Long duration spaceflight missions will require crew to become more autonomous in conducting extravehicular activities (EVA) without direct communication with Mission Control for biomedical support. To enable such autonomy, we are developing a Crew State and Risk Model (CSRM) as a collection of key physiology domains that drive EVA crew capabilities and workloads. One model component of CSRM is human thermal regulation. In this paper, customized development of a baseline model to predict core body temperature is presented using physiology inputs of heart rate and metabolic rate. The model development dataset included a baseline study where participants (n=6, equal male and female) performed a 5-hour EVA in a two-part session while wearing a hybrid space suit simulator (HS3). The first session included an end-to-end EVA traversing 1500 meters to a geology site and traversing back to a habitat conducting geology, payload relocation, and maintenance operations every 500 meters. The second session included standalone tasks of a 2000-meter traverse followed by geology tasks. Thermal measures of core body temperature, local skin temperature, liquid cooling garment temperature, heart rate, and metabolic rate were collected through the test duration. Multiple regression was used to build a linear equation to predict core body temperature from inputs of heart rate and metabolic rate. Heat storage was calculated via predicted core body temperature plus LCG and skin temperatures. The model was tested against a dataset from a pressurized suited test (n=6, equal male and female) in the NASA Active Response Gravity Offload System (ARGOS) conducting similar end-to-end EVA and standalone tasks. Predicted error of the model against the raw test cases was 0.2±0.15 °C. The baseline prediction of core body temperature using heart rates and metabolic rates allows for simple real-time tracking from data collected in-flight to monitor crew consumables and thermal flight limits during EVA.

Bradley Hoffmann

Circadian variation of EEG power spectra in NREM and REM sleep in humans: dissociation from body temperature

In humans, EEG power spectra in REM and NREM sleep, as well as characteristics of sleep spindles such as their duration, amplitude, frequency and incidence, vary with circadian phase. Recently it has been hypothesized that circadian variations in EEG spectra in humans are caused by variations in brain or body temperature and may not represent phenomena relevant to sleep regulatory processes. To test this directly, a further analysis of EEG power spectra - collected in a forced desynchrony protocol in which sleep episodes were scheduled to a 28-h period while the rhythms of body temperature and plasma melatonin were oscillating at their near 24-h period - was carried out. EEG power spectra were computed for NREM and REM sleep occurring between 90-120 and 270-300 degrees of the circadian melatonin rhythm, i.e. just after the clearance of melatonin from plasma in the 'morning' and just after the 'evening' increase in melatonin secretion. Average body temperatures during scheduled sleep at these two circadian phases were identical (36.72 degrees C). Despite identical body temperatures, the power spectra in NREM sleep were very different at these two circadian phases. EEG activity in the low frequency spindle range was significantly and markedly enhanced after the evening increase in plasma melatonin as compared to the morning phase. For REM sleep, significant differences in power spectra during these two circadian phases, in particular in the alpha range, were also observed. The results confirm that EEG power spectra in NREM and REM sleep vary with circadian phase, suggesting that the direct contribution of temperature to the circadian variation in EEG power spectra is absent or only minor, and are at variance with the hypothesis that circadian variations in EEG power spectra are caused by variations in temperature.

Non-NASA Center

The timing of the human circadian clock is accurately represented by the core body temperature rhythm following phase shifts to a three-cycle light stimulus near the critical zone

A double-stimulus experiment was conducted to evaluate the phase of the underlying circadian clock following light-induced phase shifts of the human circadian system. Circadian phase was assayed by constant routine from the rhythm in core body temperature before and after a three-cycle bright-light stimulus applied near the estimated minimum of the core body temperature rhythm. An identical, consecutive three-cycle light stimulus was then applied, and phase was reassessed. Phase shifts to these consecutive stimuli were no different from those obtained in a previous study following light stimuli applied under steady-state conditions over a range of circadian phases similar to those at which the consecutive stimuli were applied. These data suggest that circadian phase shifts of the core body temperature rhythm in response to a three-cycle stimulus occur within 24 h following the end of the 3-day light stimulus and that this poststimulus temperature rhythm accurately reflects the timing of the underlying circadian clock.

Non-NASA Center

Environmental stressors during space flight: potential effects on body temperature

1. Organisms may be affected by many environmental factors during space flight, e.g., acceleration, weightlessness, decreased pressure, changes in oxygen tension, radiofrequency radiation and vibration. 2. Previous studies of change in body temperature--one response to these environmental factors--are reviewed. 3. Conditions leading to heat stress and hypothermia are discussed.

Review