Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Body Height”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Adult height, body mass index change, and body shape change in relation to esophageal squamous cell carcinoma risk: A population‐based case‐control study in China

Abstract The relationship between risk of esophageal squamous cell carcinoma (ESCC) and adult height, changes in individual body mass index (BMI) and body shape is not established. We performed a large population‐based case‐control study, which enrolled a total of 1414 ESCC cases and 1989 controls in a high‐incidence area in China. Using face‐to‐face interview with a structured questionnaire, information on participants' heights, weights, and perceived body shapes at 20 years of age was collected. Additionally, data on weight and perceived body shape among the same participants 10 years prior to ascertainment were collected using the same method. Odd ratios (ORs) of ESCC risk in relation to BMI and body shape were estimated using unconditional logistic regression models. The adjusted results indicated that ESCC risk in adults rapidly rose as height increased, plateauing at 170 cm among men and 157 cm among women. Among participants who were underweight, normal weight, or thinner than body shape 4, body weight loss was associated with increased risk of ESCC, and body weight gain was associated with decreased incidence of ESCC (ORs ranging from 0.40 to 0.76). Notably, however, changes in body weight did not significantly affect ESCC risk among participants who were overweight, obese, or larger than body shape 3. Maintaining a fit body shape and a reasonable BMI is advisable and of vital importance to reduce the risk of ESCC, especially in high‐risk areas.

Yang, Xiaorong↗

Accuracy of self‐reported weight, height and body mass index among older people in Japan

Aim Weight and height are usually self‐reported in population‐based epidemiological surveys. While the accuracy of self‐reports has been extensively studied in younger populations, less is known in older populations. We investigated the accuracy of self‐reported weight, height and body mass (BMI) in an older cohort in Japan, where overweight/obesity and underweight coexist. Methods We used data from older Japanese adults (≥65 years) participating in the Japan Gerontological Evaluation Study in 2016 to 2017 (7357 men and 9271 women). Self‐report data were linked to objective data obtained from clinical examinations. Results The mean ± standard deviation (SD) age was 74.5 ± 5.8 years, mean ± SD weight, height and BMI were 55.7 ± 10.1 kg, 156.0 ± 8.9 cm and 22.8 ± 3.1, respectively. Results showed high intraclass correlation coefficients for self‐reported and measured values (0.97 for weight; 0.96 for height). While weight/height were overestimated among men (weight by 0.096 kg; height by 0.27 cm) and women (weight by 0.18 kg; height by 0.27 cm), BMI tended to be slightly underestimated (−0.034 kg/m 2 for men; −0.037 kg/m 2 for women). However, the absolute differences between self‐reported and measured values were not negligible; people had a higher risk for both under‐ and overestimation of their BMI category with increasing age. Lower education predicted BMI overestimation, whereas lower income predicted BMI underestimation. Conclusions Overall accuracy of self‐reported body habitus was higher in this cohort of older Japanese compared with previous reports. Nevertheless, misclassification of BMI due to the misreporting of their weight/height was more common among the oldest‐old, as well as those with lower education and income. Geriatr Gerontol Int 2020; 20: 803–810 .

Yazawa, Aki↗

Functional vs. Traditional Analysis in Biomechanical Gait Data: An Alternative Statistical Approach

In human motion studies, discrete points such as peak or average kinematic values are commonly selected to test hypotheses. The purpose of this study was to describe a functional data analysis and describe the advantages of using functional data analyses when compared with a traditional analysis of variance (ANOVA) approach. Nineteen healthy participants (age: 22 ± 2 yrs, body height: 1.7 ± 0.1 m, body mass: 73 ± 16 kg) walked under two different conditions: control and pain+effusion. Pain+effusion was induced by injection of sterile saline into the joint capsule and hypertonic saline into the infrapatellar fat pad. Sagittal-plane ankle, knee, and hip joint kinematics were recorded and compared following injections using 2×2 mixed model ANOVAs and FANOVAs. The results of ANOVAs detected a condition × time interaction for the peak ankle (F1,18 = 8.56, p = 0.01) and hip joint angle (F1,18 = 5.77, p = 0.03), but did not for the knee joint angle (F1,18 = 0.36, p = 0.56). The functional data analysis, however, found several differences at initial contact (ankle and knee joint), in the mid-stance (each joint) and at toe off (ankle). Although a traditional ANOVA is often appropriate for discrete or summary data, in biomechanical applications, the functional data analysis could be a beneficial alternative. Thus when using the functional data analysis approach, a researcher can (1) evaluate the entire data as a function, and (2) detect the location and magnitude of differences within the evaluated function.

59 BASIC BIOLOGICAL SCIENCES↗

Age affects severity of venous gas emboli on decompression from 14.7 to 4.3 psia

INTRODUCTION: Variables that define who we are, such as age, weight and fitness level influence the risk of decompression sickness (DCS) and venous gas emboli (VGE) from diving and aviation decompressions. We focus on age since astronauts that perform space walks are approximately 10 yr older than our test subjects. Our null hypothesis is that age is not statistically associated with the VGE outcomes from decompression to 4.3 psia. METHODS: Our data are from 7 different NASA tests where 188 men and 50 women performed light exercise at 4.3 psia for planned exposures no less than 4 h. Prebreathe (PB) time on 100% oxygen ranged from 150-270 min, including ascent time, with exercise of different intensity and length being performed during the PB in four of the seven tests with 150 min of PB. Subjects were monitored for VGE in the pulmonary artery using a Doppler ultrasound bubble detector for a 4-min period every 12 min. There were six design variables; the presence or absence of lower body adynamia and five PB variables; plus five concomitant variables on physical characteristics: age, weight height, body mass index, and gender that were available for logistic regression (LR). We used LR models for the probability of DCS and VGE, and multinomial logit (ML) models for the probability of Spencer VGE Grades 0-IV at exposure times of 61, 95, 131, 183 min, and for the entire exposure. RESULTS: Age was significantly associated with VGE in both the LR and ML models, so we reject the null hypothesis. Lower body adynamia was significant for all responses. CONCLUSIONS: Our selection of tests produced a wide range of the explanatory variables, but only age, lower body adynamia, height, and total PB time was helpful in various combinations to model the probability of DCS and VGE.

Clinical Trial↗

The Ice, Cloud, and Land Elevation Satellite-2 Mission: A Global Geolocated Photon Product Derived from the Advanced Topographic Laser Altimeter System

The Ice, Cloud, and land Elevation Satellite – 2 (ICESat-2) observatory was launched on 15 September 2018 to measure ice sheet and glacier elevation change, sea ice freeboard, and enable the determination of the heights of Earth’s forests. ICESat-2’s laser altimeter, the Advanced Topographic Laser Altimeter System (ATLAS) uses green (532 nm) laser light and single-photon sensitive detection to measure time of flight and subsequently surface height along each of its six beams. In this paper, we describe the major components of ATLAS, including the transmitter, the receiver and the components of the timing system. We present the major components of the ICESat-2 observatory, including the Global Positioning System, star trackers and inertial measurement unit. The ICESat-2 Level 1B data product (ATL02) provides the precise photon round-trip time of flight, among other data. The ICESat-2 Level 2A data product (ATL03) combines the photon times of flight with the observatory position and attitude to determine the geodetic location (i.e. the latitude, longitude and height) of the ground bounce point of photons detected by ATLAS. The ATL03 data product is used by higher-level (Level 3A) surface-specific data products to determine glacier and ice sheet height, sea ice freeboard, vegetation canopy height, ocean surface topography, and inland water body height.

ICESat-2↗

Head-Down Tilt with Balanced Traction as a Model for Simulating Spinal Acclimation to Microgravity

Astronauts experience total body height increases of 4 to 7 cm in microgravity. Thus, stretching of the spinal cord, nerve roots, and muscular and ligamentous tissues may be responsible for the hyperreflexia, back pain, and muscular atrophy associated with exposure to microgravity. Axial compression of the spine makes 6 deg. head-down tilt (HDT) an unsuitable model for spinal acclimation to microgravity. However, this axial compression may be counteracted by balanced traction consisting of 10% body weight (sin 6 deg. = 0.1) applied to the legs. Six healthy male subjects underwent 3 days each of 60 HDT with balanced traction and horizontal bed rest (HBR), with a 2 week recovery period between treatments. Total body and spine length, lumbar disc height, back pain, erector spinae intramuscular pressure, and ankle joint torque were measured before, during and after each treatment. Total body and spine (processes of L5 - C7) lengths increased significantly more during HDT with balanced traction (22 +/- 8 mm and 25 +/- 8 mm, respectively) than during HBR (16 +/- 4 mm and 14 +/- 9 mm, respectively). Back and leg pain were significantly greater during HDT with balanced traction than during HBR. The distance between the lower end plate of L4 and the upper endplate of S1, as measured by sonography, increased significantly in both treatments to the same degree (2.9 +/- 1.9 mm, HDT with balanced traction; 3.3 +/- 1.5 mm, HBR). Intramuscular pressure of the erector spinae muscles and maximal ankle joint torque were unaltered with both models. While neither model increased height to the magnitude observed in microgravity, HDT with balanced traction may be a better model for simulating the body lengthening and back pain experienced in microgravity.

Ballard, R. E.↗

Changes in intervertebral disc cross-sectional area with bed rest and space flight

STUDY DESIGN. We measured the cross-sectional area of the intervertebral discs of normal volunteers after an overnight rest; before, during, and after 5 or 17 weeks of bed rest; and before and after 8 days of weightlessness. OBJECTIVES. This study sought to determine the degree of expansion of the lumbar discs resulting from bed rest and space flight. SUMMARY OF BACKGROUND DATA. Weightlessness and bed rest, an analog for weightlessness, reduce the mechanical loading on the musculoskeletal system. When unloaded, intervertebral discs will expand, increasing the nutritional diffusion distance and altering the mechanical properties of the spine. METHODS. Magnetic resonance imaging was used to measure the cross-sectional area and transverse relaxation time (T2) of the intervertebral discs. RESULTS. Overnight or longer bed rest causes expansion of the disc area, which reaches an equilibrium value of about 22% (range 10-40%) above baseline within 4 days. Increases in disc area were associated with modest increases in disc T2. During bed rest, disc height increased approximately 1 mm, about one-half of previous estimates based on body height measurements. After 5 weeks of bed rest, disc area returned to baseline within a few days of ambulation, whereas after 17 weeks, disc area remained above baseline 6 weeks after reambulation. After 8 days of weightlessness, T2, disc area, and lumbar length were not significantly different from baseline values 24 hours after landing. CONCLUSIONS. Significant adaptive changes in the intervertebral discs can be expected during weightlessness. These changes, which are rapidly reversible after short-duration flights, may be an important factor during and after long-duration missions.

Non-NASA Center↗

Back pain during 6 degrees head-down tilt approximates that during actual microgravity

Astronauts often experience back pain during spaceflight. Retrospectively, Wing et al. (14) found that during spaceflight, 14 of 19 Shuttle crewmembers experienced back pain, which they described as dull (62%), localized to the lower back (50%), and with an intensity of 2 on a 5-point scale. Further, the spine lengthens 4-7 cm in microgravity. Our objective was to compare back pain and spinal lengthening (body height increase) during simulated microgravity (6 degrees head-down tilt, HDT) with the same parameters during actual microgravity. Eight male subjects completed a modified McGill pain questionnaire with intensity graded from zero (no pain) to five (intense and incapacitating pain) each day at 7:00 pm during 2 d pre-HDT control, 16 d HDT, and 1 d post-HDT recovery periods. Also, the subjects' heights were measured each day while supine (control and recovery) and during HDT. Back pain increased from zero (pre-tilt control period) to 2.3 +/- 0.4 at days 1 to 3 of HDT, and was categorized as dull and/or burning pain in subjects' lower backs. Only 2 subjects reported any pain after day 9 of HDT and during recovery. Heights increased 2.1 +/- 0.5 cm by day 3 of HDT and remained at that level until the end of the HDT period. Although spinal lengthening in space is greater than that during HDT, the HDT model approximates the level, type, distribution, and time course of back pain associated with actual microgravity. In the HDT model, pain subsides in intensity when spinal lengthening stops.(ABSTRACT TRUNCATED AT 250 WORDS).

Non-NASA Center↗

CIRSE Guidelines on Percutaneous Vertebral Augmentation

Vertebral compression fracture (VCF) is an important cause of severe debilitating back pain, adversely affecting quality of life, physical function, psychosocial performance, mental health and survival. Different vertebral augmentation procedures (VAPs) are used in order to consolidate the VCFs, relief pain,and whenever posible achieve vertebral body height restoration. In the present review we give the indications, contraindications, safety profile and outcomes of the existing percutaneous VAPs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Back Pain During 6 deg Head-Down Tilt Approximates That During Actual Microgravity

Astronauts often experience back pain during spaceflight. It was found that during spaceflight, 14 of 19 Shuttle crewmembers experienced back pain, which they described as dull (62%), localized to the lower back (500/6), and with an intensity of 2 on a 5-point scale. Further, the spine lengthens 4-7 cm in microgravity. Our objective was to compare back pain and spinal lengthening (body height increase) during simulated microgravity (6 deg head-down tilt, HDT) with the some parameters during actual microgravity. Eight male subjects completed a modified McGill pain questionnaire with intensity graded from zero (no pain) to five (intense and incapacitating gain) each day at 7.-OO pm during 2 d pre-HDT control, 16 d HDT, and I d post-HDT recovery periods. Only 2 subjects reported any pain after day 9 of HDT and during recov- ery. Heights increased 2.1 t 0.5 cm by day 3 of HDT and re- mained at that level until the end of the HDT period. Although spinal lengthening in space is greater than that during HDT, the HDT model approximates the level, type, distribution, and time course of back pain associated with actual microgrovity. In the HDT model, pain subsides in intensity when spinal lengthening stops. Therefore, back pain in actual and simulated microgravity may result from stretching of spinal andlor paraspinal tissues until a new spinal length is reached.

Karen J. Hutchinson↗

Left ventricular dimensions and mass using magnetic resonance imaging in female endurance athletes

Few published studies of left ventricular (LV) mass in female endurance athletes have been performed with M-mode echocardiography, which involves assumptions of LV geometry. Therefore, magnetic resonance imaging, a 3-dimensional technique, was used to examine LV mass, LV end-diastolic volume and mean wall thickness in female long distance runners (n = 13; mean age 29 years), cyclists (n = 12; mean age 26 years) and cross-country skiers (n = 11; mean age 24 years), and the findings were compared with sedentary control subjects (n = 10; mean age 27 years) matched for height and body weight. The physical characteristics for all subjects included height (mean 166 cm, and body weight (mean 56 kg). The percent body fat (mean 11.7) and maximal oxygen uptake (VO2max, mean 63 ml.kg-1.min-1) were similar (p greater than 0.05) among all athletic groups, but significantly different from the control group (body fat, mean 22.5%; VO2max, mean 35 ml.kg-1.min-1). LV mass (mean 159 kg), LV end-diastolic volume (mean 122 ml), and mean wall thickness (mean 11.5 mm) were also similar among the athletic groups and significantly larger than the following control values: LV mass (mean 115 g), LV end-diastolic volume (mean 93 ml) and mean wall thickness (mean 9.8 mm). Ratios of LV mass to lean body weight were similar among all athletic groups, although athletic groups had larger ratios (p less than 0.05) than the sedentary control subjects. LV mass/LV end-diastolic volume ratio was similar (p greater than 0.05) among all groups.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Cardiopulmonary↗

The development of a population of 4D pediatric XCAT phantoms for imaging research and optimization

Purpose: We previously developed a set of highly detailed 4D reference pediatric extended cardiac-torso (XCAT) phantoms at ages of newborn, 1, 5, 10, and 15 yr with organ and tissue masses matched to ICRP Publication 89 values. In this work, we extended this reference set to a series of 64 pediatric phantoms of varying age and height and body mass percentiles representative of the public at large. The models will provide a library of pediatric phantoms for optimizing pediatric imaging protocols. Methods: High resolution positron emission tomography-computed tomography data obtained from the Duke University database were reviewed by a practicing experienced radiologist for anatomic regularity. The CT portion of the data was then segmented with manual and semiautomatic methods to form a target model defined using nonuniform rational B-spline surfaces. A multichannel large deformation diffeomorphic metric mapping algorithm was used to calculate the transform from the best age matching pediatric XCAT reference phantom to the patient target. The transform was used to complete the target, filling in the nonsegmented structures and defining models for the cardiac and respiratory motions. The complete phantoms, consisting of thousands of structures, were then manually inspected for anatomical accuracy. The mass for each major tissue was calculated and compared to linearly interpolated ICRP values for different ages. Results: Sixty four new pediatric phantoms were created in this manner. Each model contains the same level of detail as the original XCAT reference phantoms and also includes parameterized models for the cardiac and respiratory motions. For the phantoms that were 10 yr old and younger, we included both sets of reproductive organs. This gave them the capability to simulate both male and female anatomy. With this, the population can be expanded to 92. Wide anatomical variation was clearly seen amongst the phantom models, both in organ shape and size, even for models of the same age and sex. The phantoms can be combined with existing simulation packages to generate realistic pediatric imaging data from different modalities. Conclusions: This work provides a large cohort of highly detailed pediatric phantoms with 4D capabilities of varying age, height, and body mass. The population of phantoms will provide a vital tool with which to optimize 3D and 4D pediatric imaging devices and techniques in terms of image quality and radiation-absorbed dose.

60 APPLIED LIFE SCIENCES↗

Standoff Human Identification Using Body Shape

The ability to identify individuals is a key component of maintaining safety and security in public spaces and around critical infrastructure. Monitoring an open space is challenging because individuals must be identified and re-identified from a standoff distance nonintrusively, making methods like fingerprinting and even facial recognition impractical. We propose using body shape features as a means for identification from standoff sensing, either complementing other identifiers or as an alternative. An important challenge in monitoring open spaces is reconstructing identifying features when only a partial observation is available, because of the view-angle limitations and occlusion or subject pose changes. To address this challenge, we investigated the minimum number of features required for a high probability of correct identification, and we developed models for predicting a key body feature—height—from a limited set of observed features. We found that any set of nine randomly selected body measurements was sufficient to correctly identify an individual in a dataset of 4426 subjects. For predicting height, anthropometric measures were investigated for correlation with height. Their correlation coefficients and associated linear models were reported. These results—a sufficient number of features for identification and height prediction from a single feature—contribute to developing systems for standoff identification when views of a subject are limited.

Matzner, Shari↗

TH-EF-BRB-06: Implementation of a Modulated-Arc Total Body Irradiation (TBI) Technique Using the RayStation Treatment Planning System

Purpose: To develop a clinical workflow for delivering a modulated-arc total body irradiation (TBI) with RayStation scripting. This technique uses arc fields with the patient lying at floor level on a padded table and is validated through measurements taken on a custom-made TBI phantom. Methods: Treatment planning was performed for a retrospective cohort of eight patients with a diverse range of heights and body types. Each was replanned using an open-field dual arc method, with the patient in supine and prone positions on the floor of the vault. All plans were optimized using Raystation Planning 4.7.2.5 (RaySearch Laboratories, Stockholm, Sweden), with 200 cGy prescribed to the 95% of the body contour − 5mm. This results in an open-field beam that sweeps craniocaudally across the length of the patient. The technique is validated with measurements at 10 cm intervals in a custom-milled, 5 cm thick acrylic phantom. A centrally located CC13 ion chamber and a Mobile MOSFET (Best Medical Canada, Ottawa, ON) detector array were used to measure dose. Supine and prone arcs for each patient were consecutively delivered, and the aggregate dose at each point was compared to the planned dose calculated in the phantom. Results: The ion chamber measurements differed from the planned dose by an average of .5%, with a standard deviation of 2.1%. All measured data for the MOSFETS were within 10% of the corresponding planned dose except for two outlying points. The standard deviation of dose differences across the entire cohort was 4.0%. Most significant discrepancies occurred either in inhomogeneous regions with large gradients, or at inferior points where beam angle was steepest. Conclusion: We have confirmed that the planned dose is well matched to our measurements within 10% for this method of planning and delivery. We are currently incorporating this technique into our clinical workflow. This work is supported by RaySearch.

60 APPLIED LIFE SCIENCES↗

Height increase, neuromuscular function, and back pain during 6 degrees head-down tilt with traction

BACKGROUND: Spinal lengthening and back pain are commonly experienced by astronauts exposed to microgravity. METHODS: To develop a ground-based simulation for spinal adaptation to microgravity, we investigated height increase, neuromuscular function and back pain in 6 subjects all of whom underwent two forms of bed rest for 3 d. One form consisted of 6 degrees of head-down tilt (HDT) with balanced traction, while the other was horizontal bed rest (HBR). Subjects had a 2-week recovery period in between the studies. RESULTS: Total body and spinal length increased significantly more and the subjects had significantly more back pain during HDT with balanced traction compared to HBR. The distance between the lower endplate of L4 and upper endplate of S1, as measured by ultrasonography, increased significantly in both treatments to the same degree. Intramuscular pressures in the erector spinae muscles and ankle torque measurements during plantarflexion and dorsiflexion did not change significantly during either treatment. CONCLUSION: Compared to HBR, HDT with balanced traction may be a better method to simulate changes of total body and spinal lengths, as well as back pain seen in microgravity.

NASA Discipline Number 26-10↗