Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Bioreactor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Design, Prototyping, and Testing of a Novel Flowpath with an Array of Six 3D Matrix Vitvo Bioreactors for the NASA Bioculture System

The NASA Bioculture System is an advanced cell culture closed-loop system containing highly automated flowpaths designed to conduct long term biology experiments on ISS with earth remote controllable medium flow, temperature, gas composition, medium exchange, cell sampling and fixation. This technology was already demonstrated with successful cardiomyocyte and osteocyte cultures experiments onboard the ISS and is now supporting NASA PI science. The Bioculture System, however, can only support 10 cassettes with disposable flowpaths, each containing a single hollow fiber bioreactor with a culture capacity of about 2ml. This constraint not only severely limits the number of investigators that can conduct experiments in space, but also subjects the experiments to limitations in the number of replicates and conditions that can be studied. To address these limitations, we sought a novel design solution to maximize the number of separate bioreactor cultures and volume that can be conducted simultaneously. To this end we designed, prototyped, and are now testing a six-Vitvo 3D Matrix 2ml bioreactor insert that replaces the conventional Bioculture System hollow fiber bioreactor. This design will allow the Bioculture System to support up to 60 different bioreactors and samples at once. Specifically, the novel gas-tight containment housing insert contains six COTS Rigenerand VITVO bioreactors stacked on each side of a heat sink powered by the existing heating element and pair of temperature sensors. Medium will be distributed into each bioreactor's cell-free chamber via its built-in Luer connector, then across the 3D matrix to the cell chamber, dissipating laminar flow and limiting fluid shear stresses that might mechanostimulate cell cultures. Gas (5% CO2 in air) will be supplied directly to the bioreactor gas-tight housing for exchange via the bioreactor flat-surface gas-permeable membranes, eliminating the need for the existing Bioculture System cassette oxygenator. If successfully implemented on ISS, this new multi-bioreactor insert for the Bioculture System has the potential to make real-time cell science experimentation in space more efficient and accessible to more investigators.

Ma, Kristin R.↗

An Optical Oxygen Sensor for Long-Term Continuous Monitoring of Dissolved Oxygen in Perfused Bioreactors

For long-term growth of man1ITlalian cells in perfused bioreactors, it is essential to monitor the concentration of dissolved oxygen (DO) present in the culture medium to quantitate and control level of DO. Continuous measurement of the amount of DO in the cell culture medium in-line under sterile conditions in NASA's perfused bioreactor requires that the oxygen sensor provide increased sensitivity and be sterilizable and nontoxic. Additionally, long-term cell culture experiments require that the calibration be maintained several weeks or months. Although there are a number of sensors for dissolved oxygen on the market and under development elsewhere, very few meet these stringent conditions. An optical oxygen sensor (BOXY) based on dynamic fluorescent quenching and a pulsed blue LED light source was developed in our laboratory to address these requirements. Tris( 4,7 -diphenyl-l, 1 O-phenanthroline )ruthenium(II) chloride is employed as the fluorescent dye indicator. The sensing element consists of a glass capillary (OD 4.0 mm; ID 2.0 mm) coated internally with a thin layer of the fluorescent dye in silicone matrix and overlayed with a black shielding layer. Irradiation of the sensing element with blue light (blue LED with emission maximum at 475 nm) generates a red fluorescence centered at 626 nm. The fluorescence intensity is correlated to the concentration of DO present in the culture medium, following the modified non-linear Stern-Volmer equation. By using a pulsed irradiating light source, the problem of dye-bleaching, which is often encountered in long-term continuous measurements of tIns type, 'is minimized. To date we achieved sensor resolution of 0.3 mmHg at 50 mmHg p02, and 0.6 mmHg at 100 mmHg p02, with a response time of about one minute. Calibration was accomplished in sterile phosphate-buffered saline with a blood-gas analyzer (BGA) measurement as reference. Stand-alone software was also developed to control the sensor and bioreactor as well as to acquire data. Two HOXY sensors with a single calibration were employed to continuously monitor the DO in GTSF-2 medium during a Baby Hamster Kidney (BHK-21) cell culture in a Rotating Wall Perfused Vessel (RWPV) bioreactor for 90 days. HOXY sensors were located at the inlet to and outlet from the bioreactor. One of the sensors was placed between an oxygenator and the inlet to the bioreactor. The dissolved oxygen concentrations determined by both sensors were compared with those measured regularly with the BGA reference. The cell culture was maintained for 110 days. Sensor output was found to correlate well with the BGA data throughout the experiment, where the DO of the medium ranged between 25 and 50 mmHg at the bioreactor outlet and 90-130 mmHg at the bioreactor inlet. Measuring DO with the HOXY sensors versus the BGA reference indicated bias values of -2 mmHg and -15 mmHg, and precision values of +/-3mmHg and +/-16 mmHg at the bioreactor inlet and outlet, respectively.

Gao, F. G.↗

Bioreactors: Design, Background, and Applications

A bioreactor is any reaction vessel designed to contain a biological reaction with the aims of either growing an organism, producing a biological product, bioremediating waste, or investigating the workings of a biological process within a controlled environment. Bioreactors compose a broad category of useful and ubiquitous technologies present throughout the bioeconomy, which are inherently “dualuse” technologies: holding both immense potential for both benefit and harm to society. Due to this duality, national security professionals must bridge technological understanding and policy acumen to understand how bioreactors are integrated into both, many peaceful applications throughout the global bioeconomy such as in developing or manufacturing life-saving pharmaceuticals, as well as potentially harmful and/or illicit uses, such as producing biowarfare agent. The following document gives a surface-level introduction into this broad category of technology. The first two sections of this document describe the historical origins, then typical contemporary uses of bioreactors as a critical component of the modern bioeconomy providing examples for each use case. The following two sections begin to give a technical description of bioreactor technology introducing the features commonly found in simple bioreactors and providing a non-exhaustive framework for categorizing bioreactors commonly found in wet-microbiology applications. The last two sections present two short discussions on the challenges facing modern bioreactor technology, firstly from a technical standpoint, and then from the non-technical standpoint with special attention to the dual-use dilemma and issue of responsible technological development inherent in most biotechnology.

59 BASIC BIOLOGICAL SCIENCES↗

Design challenges for space bioreactors

The design of bioreactors for operation under conditions of microgravity presents problems and challenges. Absence of a significant body force such as gravity can have profound consequences for interfacial phenomena. Marangoni convection can no longer be overlooked. Many speculations on the advantages and benefits of microgravity can be found in the literature. Initial bioreactor research considerations for space applications had little regard for the suitability of the designs for conditions of microgravity. Bioreactors can be classified in terms of their function and type of operation. The complex interaction of parameters leading to optimal design and operation of a bioreactor is illustrated by the JSC mammalian cell culture system. The design of a bioreactor is strongly dependent upon its intended use as a production unit for cell mass and/or biologicals or as a research reactor for the study of cell growth and function. Therefore a variety of bioreactor configurations are presented in rapid summary. Following this, a rationale is presented for not attempting to derive key design parameters such as the oxygen transfer coefficient from ground-based data. A set of themes/objectives for flight experiments to develop the expertise for design of space bioreactors is then proposed for discussion. These experiments, carried out systematically, will provide a database from which engineering tools for space bioreactor design will be derived.

Seshan, P. K.↗

Anaerobic Dynamic Membrane Bioreactor Development to Facilitate Organic Waste Conversion to Medium-Chain Carboxylic Acids and Their Downstream Recovery

Platform chemicals such as medium-chain carboxylic acids (MCCAs) can be produced from organic waste streams via chain elongation in anaerobic mixed-culture bioreactors. A product recovery system is needed to collect MCCAs from the bioreactor effluent. Membrane-based liquid–liquid extraction, the most commonly used product recovery approach, requires suspended solids removal from the bioreactor effluent to avoid membrane fouling. An anaerobic dynamic membrane bioreactor (AnDMBR) was developed to evaluate MCCA production from brewery and prefermented food waste and to produce a permeate with low suspended solids to facilitate downstream product recovery. The AnDMBR employed an inexpensive stainless-steel mesh as the support material for the development of a biofilm or dynamic membrane, which was responsible for solids–liquid separation. The AnDMBR produced a permeate quality with an average total suspended solids (TSS) concentration of 0.12 g L –1 , while the average bioreactor TSS concentration was two orders of magnitude higher (21.6 g L –1 ). A maximum solids removal efficiency of ≥99% was achieved and good permeate quality was sustained for over 200 days without fouling control or cleaning the support material. In addition to solids–liquid separation, the dynamic membrane was responsible for a substantial fraction of the biological activity of the AnDMBR. The relative activity of Clostridiales, as determined by 16S rRNA sequencing, correlated with MCCA production and was higher in the dynamic membrane (20.0 ± 4.9%) than in the suspended biomass (5.2 ± 2.7%) in the bioreactor. This observation was consistent with MCCA production data as the permeate MCCA concentrations were significantly (p = 8.2 × 10 –5 ) higher than that in the bioreactor, suggesting that the dynamic membrane biofilm contributed to chain elongation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CDC Bioreactor Configuration Method for Volume Level Control with Controlled Inlet and Outlet Flow

Environmental Control Life Support Systems and other microbiological biofilm studies often utilize small scale bioreactors. Among these options are the popular BioSurface CDC bioreactors, currently being utilized by Marshall Space Flight Center groups researching the impact of biofilms on life support systems. After a recent experimental regime, it was determined additional equipment could be added to augment the capabilities of the bioreactors. Previous research configurations such as ASTM E3161 – 18 relied on an outlet stream gravity draining from a side drain port located above sampling coupons. This limited applications to experimental conditions with a controlled inlet and uncontrolled outlet flow. With the introduction of a small single pole single throw (SPST) reed float switch, a peristaltic pump connected to the outlet drain and a chassis controller, the bioreactor is able to maintain a set level. The modification allows additional variables to be tested, including highly adjustable fill and flush cycles, bioreactor volume, draining and filling control. Once the configuration modifications were implemented through the installation of the new equipment, data was collected to ensure the stability of the level measurements. As the level control switch is a float switch, consideration was taken into account for effects of internal stirring speed, along with effects of inlet and outlet flow rate. Data presented in this study will illustrate the stability and effectiveness of the configuration changes in equipment made to the bioreactor. These configuration changes are proving an effective control method to conduct biofilm mitigation techniques for ECLSS hardware research. The controlled level capabilities allow for a constant drip feed flow rate into the bioreactors, a key aspect of the biofilm mitigation testing.

CDC Bioreactor↗

CDC Bioreactor Configuration Method for Volume Level Control with Controlled Inlet and Outlet Flow

Environmental Control Life Support Systems and other microbiological biofilm studies often utilize small scale bioreactors. Among these options are the popular BioSurface CDC bioreactors, currently being utilized by Marshall Space Flight Center groups researching the impact of biofilms on life support systems. After a recent experimental regime, it was determined additional equipment could be added to augment the capabilities of the bioreactors. Previous research configurations such as ASTM E3161-21 relied on an outlet stream gravity draining from a side drain port located above sampling coupons. This limited applications to experimental conditions with a controlled inlet and uncontrolled outlet flow. With the introduction of a small single pole single throw (SPST) reed float switch and a peristaltic pump connected to the outlet drain and a chassis controller, the bioreactor is able to maintain a set level. The modification allows additional variables to be tested, including highly adjustable fill and flush cycles, bioreactor volume, draining and filling control. Once the configuration modifications were implemented through the installation of the new equipment, data was collected to ensure the stability of the level measurements. As the level control switch is a float switch, consideration was taken into account for effects of internal stirring speed, along with effects of inlet and outlet flow rate. Data presented in this study will illustrate the stability and effectiveness of the configuration changes in equipment made to the bioreactor. These configuration changes have demonstrated control method to conduct biofilm mitigation techniques for ECLSS hardware research. The controlled level capabilities allow for a constant drip feed flow rate into the bioreactors, a key aspect of the biofilm mitigation testing.

CDC Bioreactor↗

CDC Bioreactor Configuration Method for Volume Level Control with Controlled Inlet and Outlet Flow

Environmental Control Life Support Systems and other microbiological biofilm studies often utilize small scale bioreactors. Among these options are the popular BioSurface CDC bioreactors, currently being utilized by Marshall Space Flight Center groups researching the impact of biofilms on life support systems. After a recent experimental regime, it was determined additional equipment could be added to augment the capabilities of the bioreactors. Previous research configurations such as ASTM E3161-21 relied on an outlet stream gravity draining from a side drain port located above sampling coupons. This limited applications to experimental conditions with a controlled inlet and uncontrolled outlet flow. With the introduction of a small single pole single throw (SPST) reed float switch and a peristaltic pump connected to the outlet drain and a chassis controller, the bioreactor is able to maintain a set level. The modification allows additional variables to be tested, including highly adjustable fill and flush cycles, bioreactor volume, draining and filling control. Once the configuration modifications were implemented through the installation of the new equipment, data was collected to ensure the stability of the level measurements. As the level control switch is a float switch, consideration was taken into account for effects of internal stirring speed, along with effects of inlet and outlet flow rate. Data presented in this study will illustrate the stability and effectiveness of the configuration changes in equipment made to the bioreactor. These configuration changes have demonstrated control method to conduct biofilm mitigation techniques for ECLSS hardware research. The controlled level capabilities allow for a constant drip feed flow rate into the bioreactors, a key aspect of the biofilm mitigation testing.

CDC Bioreactor↗

CDC Bioreactor Configuration Method for Volume Level Control with Controlled Inlet and Outlet Flow

Environmental Control Life Support Systems and other microbiological biofilm studies often utilize small scale bioreactors. Among these options are the popular BioSurface CDC bioreactors, currently being utilized by Marshall Space Flight Center groups researching the impact of biofilms on life support systems. After a recent experimental regime, it was determined additional equipment could be added to augment the capabilities of the bioreactors. Previous research configurations such as ASTM E3161-21 relied on an outlet stream gravity draining from a side drain port located above sampling coupons. This limited applications to experimental conditions with a controlled inlet and uncontrolled outlet flow. With the introduction of a small single pole single throw (SPST) reed float switch and a peristaltic pump connected to the outlet drain and a chassis controller, the bioreactor is able to maintain a set level. The modification allows additional variables to be tested, including highly adjustable fill and flush cycles, bioreactor volume, draining and filling control. Once the configuration modifications were implemented through the installation of the new equipment, data was collected to ensure the stability of the level measurements. As the level control switch is a float switch, consideration was taken into account for effects of internal stirring speed, along with effects of inlet and outlet flow rate. Data presented in this study will illustrate the stability and effectiveness of the configuration changes in equipment made to the bioreactor. These configuration changes have demonstrated control method to conduct biofilm mitigation techniques for ECLSS hardware research. The controlled level capabilities allow for a constant drip feed flow rate into the bioreactors, a key aspect of the biofilm mitigation testing.

CDC Bioreactor↗

On-line removal of volatile fatty acids from CELSS anaerobic bioreactor via nanofiltration

The CELSS (controlled ecological life support system) resource recovery system, which is a waste processing system, uses aerobic and anaerobic bioreactors to recover plants nutrients and secondary foods from the inedible biomass. The anaerobic degradation of the inedible biomass by means of culture of rumen bacteria,generates organic compounds such as volatile fatty acids (acetic, propionic, butyric, VFA) and ammonia. The presence of VFA in the bioreactor medium at fairly low concentrations decreases the microbial population's metabolic reactions due to end-product inhibition. Technologies to remove VFA continuously from the bioreactor are of high interest. Several candidate technologies were analyzed, such as organic solvent liquid-liquid extraction, adsorption and/or ion exchange, dialysis, electrodialysis, and pressure driven membrane separation processes. The proposed technique for the on-line removal of VFA from the anaerobic bioreactor was a nanofiltration membrane recycle bioreactor. In order to establish the nanofiltration process performance variables before coupling it to the bioreactor, a series of experiments were carried out using a 10,000 MWCO tubular ceramic membrane module. The variables studied were the bioreactor slurry permeation characteristics, such as, the permeate flux, VFA and the nutrient removal rates as a function of applied transmembrane pressure, fluid recirculation velocity, suspended matter concentration, and process operating time. Results indicate that the permeate flux, VFA and nutrients removal rates are directly proportional to the fluid recirculation velocity in the range between 0.6 to 1.0 m/s, applied pressure when these are low than 1.5 bar, and inversely proportional to the total suspended solids concentration in the range between 23,466 to 34,880. At applied pressure higher than 1.5 bar the flux is not more linearly dependent due to concentration polarization and fouling effects over the membrange surface. It was also found that the permeate flux declines rapidly during the first 5 to 8 hours, and then levels off with a diminishing rate of flux decay.

Colon, Guillermo↗

The membrane bioreactor (MBR): A hybrid technology for bioregenerative wastewater treatment and resource recovery in space

Extraplanetary surface habitat life support systems (LSS) on the Moon and Mars, as well as long-duration space travel, will require novel capabilities to withstand anticipated unique, harsh conditions. In order to provide safe, habitable environments for the crew, water purification and waste processing systems will be required to treat all sources of water (condensate, Sabatier, urine, hygiene, fecal, food waste) in order to achieve the necessary levels of recovery needed to sustain life over the long-duration missions. The ability to recycle organic wastes creates an opportunity to recover critical elements (e.g., C, H, O, N, P) for subsequent food production, water purification, and atmospheric regeneration. Bioregenerative systems mimic functions of nature in engineered systems, or bioreactors, utilizing combination of prokaryotes, eukaryotes and archaea. While these systems are commonly used on Earth for wastewater treatment, bioreactors for space travel face additional challenges. Terrestrial bioreactors often rely on gravitational settling of dense flocs and granules for cell retention. For micro- or partial-gravity environments, density differential alone will not be adequate for cell retention; a gravity-independent means for cell retention is crucial. The membrane bioreactor represents the state of the art in wastewater treatment. This hybrid system combines biological processes with membrane filtration to achieve performance beyond what each can accomplish individually. The complete cell retention in an MBR allows for the decoupling of hydraulic retention time (HRT) and solids retention time (SRT), which result in a high-thruput, compact, treatment system. The Bioregenerative Water Technology Team at NASA Kennedy Space Center and the University of South Florida has developed a bioregenerative platform based on the hybrid MBR technology. The overall architecture is compact, modular, flexible, and adaptable to mission evolutions. The main subsystems of the bioregenerative architecture include: 1) Anaerobic membrane bioreactor (AnMBR): Also termed the Organic processor assembly (OPA), the function of the AnMBR is to treat organic wastes such as fecal and food wastes. These wastes are characterized by a concentration of suspended solids comprised of carbohydrates, proteins and lipids. The assigned function of the AnMBR is to break down and covert suspended solids to biogas (methane, hydrogen and carbon dioxide), reduce effluent chemical oxygen demand (COD), liberate organically-bound nutrients, and remove pathogenic organisms. 2) Phototrophic membrane bioreactor (PMBR): The PMBR is comprised of a co-culture of microalgae and bacteria. The assigned function of the PMBR is to polish the permeate of the AnMBR to further remove dissolved organic carbon, manage nutrients (nitrogen transformation, load dampening), and perform air revitalization. 3) Food processor assembly (FPA): The FPA is a food production platform (prokaryotic or eukaryotic), fueled by outputs from the AnMBR, or PMBR. For the presentation, we will describe each step of the bioregenerative architecture, and present performance data from extended trials treating analog and real metabolic wastes.

Bioreactor↗

Cell Separations in Microgravity and Development of a Space Bioreactor

A bioreactor optimized for operations in space is now being developed. The current research is focused on determining the optimum cell-bead ratios, medium content and proper maintenance conditions required to keep living cell specimens alive and healthy for the entire flight. The bioreactor development project has recently added a microprocessor/computer to the JSC prototype for control and data analysis. Appropriate new technology is being combined with the current bioreactor designs and tested to determine what specific features must be included in the fabrication of a bioreactor designed to operate for STS demonstration tests. Considerations include: (1) circulation and resupply of culture media; (2) sensors required to monitor temperature, cell growth, mass transport, and oxygen consumption; and (3) inflight control of shear stress on cells, gas transfer in microgravity, diffusion, and intracellular transport. These data and results from the JSC prototype bioreactor test will be used for the design and construction of a small space bioreactor for the Orbiter middeck.

Morrison, D. R.↗

Effects of Bioreactor Retention Time on Aerobic Microbial Decomposition of CELSS Crop Residues

The focus of resource recovery research at the KSC-CELSS Breadboard Project has been the evaluation of microbiologically mediated biodegradation of crop residues by manipulation of bioreactor process and environmental variables. We will present results from over 3 years of studies that used laboratory- and breadboard-scale (8 and 120 L working volumes, respectively) aerobic, fed-batch, continuous stirred tank reactors (CSTR) for recovery of carbon and minerals from breadboard grown wheat and white potato residues. The paper will focus on the effects of a key process variable, bioreactor retention time, on response variables indicative of bioreactor performance. The goal is to determine the shortest retention time that is feasible for processing CELSS crop residues, thereby reducing bioreactor volume and weight requirements. Pushing the lower limits of bioreactor retention times will provide useful data for engineers who need to compare biological and physicochemical components. Bioreactor retention times were manipulated to range between 0.25 and 48 days. Results indicate that increases in retention time lead to a 4-fold increase in crop residue biodegradation, as measured by both dry weight losses and CO2 production. A similar overall trend was also observed for crop residue fiber (cellulose and hemicellulose), with a noticeable jump in cellulose degradation between the 5.3 day and 10.7 day retention times. Water-soluble organic compounds (measured as soluble TOC) were appreciably reduced by more than 4-fold at all retention times tested. Results from a study of even shorter retention times (down to 0.25 days), in progress, will also be presented.

Strayer, R. F.↗

Stacked membrane bioreactor

Scalable biomaterial-based bioreactors are described. In one embodiment, the bioreactor may comprise perforated plates stacked such that the assembled bioreactor has the necessary manifolds and chambers to transport gas and liquids to a biomaterial contained within the bioreactor, and to remove the reaction products. In another embodiment, single use bioreactors are described. Methods of operating the bioreactors are also described.

Abdullah, Zia↗

A perfused multi-well bioreactor platform to assess tumor organoid response to a chemotherapeutic gradient

There is an urgent need to develop new therapies for colorectal cancer that has metastasized to the liver and, more fundamentally, to develop improved preclinical platforms of colorectal cancer liver metastases (CRCLM) to screen therapies for efficacy. To this end, we developed a multi-well perfusable bioreactor capable of monitoring CRCLM patient-derived organoid response to a chemotherapeutic gradient. CRCLM patient-derived organoids were cultured in the multi-well bioreactor for 7 days and the subsequently established gradient in 5-fluorouracil (5-FU) concentration resulted in a lower IC 50 in the region near the perfusion channel versus the region far from the channel. We compared behaviour of organoids in this platform to two commonly used PDO culture models: organoids in media and organoids in a static (no perfusion) hydrogel. The bioreactor IC 50 values were significantly higher than IC 50 values for organoids cultured in media whereas only the IC 50 for organoids far from the channel were significantly different than organoids cultured in the static hydrogel condition. Using finite element simulations, we showed that the total dose delivered, calculated using area under the curve (AUC) was similar between platforms, however normalized viability was lower for the organoid in media condition than in the static gel and bioreactor. Our results highlight the utility of our multi-well bioreactor for studying organoid response to chemical gradients and demonstrate that comparing drug response across these different platforms is nontrivial.

59 BASIC BIOLOGICAL SCIENCES↗

Shear stress enhances microcin B17 production in a rotating wall bioreactor, but ethanol stress does not

Stress, including that caused by ethanol, has been shown to induce or promote secondary metabolism in a number of microbial systems. Rotating-wall bioreactors provide a low stress and simulated microgravity environment which, however, supports only poor production of microcin B17 by Escherichia coli ZK650, as compared to production in agitated flasks. We wondered whether the poor production is due to the low level of stress and whether increasing stress in the bioreactors would raise the amount of microcin B17 formed. We found that applying shear stress by addition of a single Teflon bead to a rotating wall bioreactor improved microcin B17 production. By contrast, addition of various concentrations of ethanol to such bioreactors (or to shaken flasks) failed to increase microcin B17 production. Ethanol stress merely decreased production and, at higher concentrations, inhibited growth. Interestingly, cells growing in the bioreactor were much more resistant to the growth-inhibitory and production-inhibitory effects of ethanol than cells growing in shaken flasks.

NASA Center JSC↗

Analysis of CDC Bioreactor Internal Thermal Measurements and Sample Coupon Temperatures

The Center for Disease Control and Prevention (CDC) bioreactor is an integral laboratory tool for the Environmental Control and Life Support Systems (ECLSS) biofilm formation and growth research program. Critical to this research is the need to adjust and maintain various surface temperatures of the coupons housed within the CDC Bioreactor. The purpose of this study was to provide quantitative temperature gradient information when the CDC Bioreactor was operating according to several process scenarios. Two primary process parameters were evaluated. For the first set of test parameters, the liquid level was maintained at 350 mL, with an inlet flowrate of 0.1 mL/min, 1 mL/min, 10 mL/min. The liquid was allowed to gravity drain out of the outlet spout. For the second set of test parameters, the liquid level within the reactor was maintained at 550 mL, with an inlet flow of 0.1 mL/min, 1 mL/min, 10 mL/min and draining intermittently controlled to 0.8 mL/min to maintain the 550 mL level. Due to the placement of the thermocouple in the reactor, a difference in temperature occurred between the coupon surfaces and target Bioreactor temperature when operated according to the first set of test parameters. When the reactor was operated according to the second set of parameters, which resulted in the thermocouple being submerged, the temperature gradient was eliminated. The results demonstrated minimal temperature gradient between the top and bottom coupon surfaces for coupons placed in a single rod within the CDC Bioreactor for both sets of test parameters evaluated. The collection of this information helped to explain previous ECLSS biofilm formation test runs, along with providing guidance on best operating practices for future ECLSS experiments. The placement of the thermocouple also helps to explain the challenge of achieving and maintaining bulk liquid temperatures when biofilm is grown according to the standardized test methods.

CDC Bioreactor↗

Bubble Experiments on the Hydrodynamic Focusing Bioreactor-Space (HFB-S)

The Hydrodynamic Focusing Bioreactor-Space (HFB-S) is being developed as a drop-in replacement for the Rotating Wall Perfused Vessel (RWPV) bioreactor currently planned for use on the International Space Station (ISS). Only the vessel itself is proposed for change, the supporting hardware will remain the same. These bioreactors are used for the growth of three-dimensional tissue culture that cannot be done in normal gravity labs. The bioreactors provide a continual supply of oxygen for cell growth, as well as periodic replacement of cell culture media with nutrients. The RWPV has had many successful flights on the space shuttle, but longer duration missions onboard the Mir Space Station resulted in bubbles inside the vessel that were detrimental to the science. It is believed that procedural changes can prevent bubble formation, but the HFB-S must not only provide a mechanism of bubble removal, but must also meet strict requirements for a low-shear environment and uniform oxygen concentration distribution for optimum cell tissue growth. A detailed technical objective (DTO) flight on the space shuttle to fully evaluate the HFB-S is currently in the planning stages. Ground-based activities are also underway to quanitify the characteristics of the HFB-S. Computational studies are being used to predict the internal fluid flow and cell trajectories. These computations will be compared to ground-based flow visualization experiments. Comparative studies of ground-based cell growth between the RWPV and the HFB-S are also in progress. These studies have shown that the HFB-S functions well as a bioreactor in normal gravity. Bubble motion and bubble removal are being studied using computational predictions as well as experimental validation.

Charles Niederhaus↗