Improved ultrasonic biomedical measuring apparatus

Device for making measurements of organs in living specimens and recording movements of organs is described. System uses series of ultrasonic pulses beamed into body of animal and reflected echo pulses are picked up by transducers and recorded. Diagram of equipment required and method of application is included.

Lee, R. D.↗

Ultrasonic biomedical measuring and recording apparatus

A train of ultrasonic pulses is beamed into the body of an animal. Organs intercepted by the beam reflect echo pulses following each transmitted pulse. An electronic gate with a variable width and a variable time delay relative to the transmitted pulse is utilized for selecting echoes derived from other organs or portions of organs. The integral of the echo signals received within the first half of the gate period is subtracted from a corresponding integral of the echo signal received during the second half of the gate to derive an error signal for controlling the time delay of the gate. In this manner, the selected echo signal is always maintained in the center of the gate.

Lee, R. D.↗

Shuttle era waste management and biowaste monitoring

The acquisition of crew biomedical data has been an important task on manned space missions. The monitoring of biowastes from the crew to support water and mineral balance studies and endocrine studies has been a valuable part of this activity. This paper will present a review of waste management systems used in past programs. This past experience will be cited as to its influence on the Shuttle design. Finally, the Shuttle baseline waste management system and the proposed Shuttle biomedical measurement and sampling systems will be presented.

Sauer, R. L.↗

Skylab medical data evaluation program (SMEDEP)

A day-by-day summary of selected data collected during the experiment is presented. The clinical and environmental data are presented in a mission-day format along with a tabulation of biomedical measurements whose values exceed three standard deviations from the preflight measurements.

Hoffler, G. W.↗

Evaluation of the Accuracy of Astroskin as a Behavioral Health Self-Monitoring System for Spaceflight

In space, there is a need to monitor astronauts' vital signs and assess their readiness to perform specific tasks during a mission. Currently, NASA does not have the capability to noninvasively monitor crew for extended periods of time. The Canadian Space Agency is working with the Psychophysiology Lab at NASA ARC to determine if the Astroskin could be used as a solution to this problem. Astroskin, a commercially available garment with built-in biosensors, can be comfortably worn under clothing or a spacesuit and relay information to the crewman's own mobile device. Data can also be sent wirelessly to the on-board Exploration Medical System. To determine if Astroskin meets requirements for health monitoring, it must first be validated in spaceflight analog environments. In the current study Astroskin data will be compared to traditional biomedical instrument measures of electrocardiography (ECG), respiration rate, and systolic blood pressure. The data will be recorded during Autogenic Feedback Training Exercise (AFTE), which is a type of physiological self-regulation training designed for astronauts. The data will also be recorded during simulations of the Orion spacecraft re-entry. The results to date suggest that Astroskin is a suitable ambulatory monitoring system that allows astronauts to self-diagnose and self-regulate adverse autonomic nervous system responses to sustained exposure to microgravity of spaceflight.

biomedical↗

An improved aesthesiometer

Biomedical tool measures cutaneous sensory perception by allowing consistent application of regular and determinable pressure to skin of the individual. Device is of relatively simple construction, inexpensive to manufacture, and easy to operate.

Wright, D.↗

Experiment support system

The Experiment Support System is a switchboard system with displays and controls. It routes electrical power to experiments M092, M093, and M171 equipment; gaseous nitrogen to the Blood Pressure Measurement System; receives biomedical data from all related equipment; routes the conditioned data signals to the Airlock Module Telemetry System and also displays (in digital or analog from) portions of that data which the crewmen must see to complete the experiment successfully. The Experiment Support System is interfaced to the M131 control panel to transfer conditioned data to the Airlock Module Telemetry System.

Shannon, A. V.↗

Biomedical and Human Factors Requirements for a Manned Earth Orbiting Station

The primary objective of this study is to determine which biomedical and human factors measurements must be made aboard a space station to assure adequate evaluation of the astronaut's health and performance during prolonged space flights. The study has employed, where possible, a medical and engineering systems analysis to define the pertinent life sciences and space station design parameters and their influence on a measurement program. The major areas requiring evaluation in meeting the study objectives include a definition of the space environment, man's response to the environment, selection of measurement and data management techniques, experimental program, space station design requirements, and a trade-off analysis with final recommendations. The space environment factors that are believed to have a significant effect on man were evaluated. This includes those factors characteristic of the space environment (e. g. weightlessness, radiation) as well as those created within the space station (e. g. toxic contaminants, capsule atmosphere). After establishing the general features of the environment, an appraisal was made of the anticipated response of the astronaut to each of these factors. For thoroughness, the major organ systems and functions of the body were delineated, and a determination was made of their anticipated response to each of the environmental categories. A judgment was then made on the medical significance or importance of each response, which enabled a determination of which physiological and psychological effects should be monitored. Concurrently, an extensive list of measurement techniques and methods of data management was evaluated for applicability to the space station program. The various space station configurations and design parameters were defined in terms of the biomedical and human factors requirements to provide the measurements program. Research design of experimental programs for various station configurations, mission durations, and crew sizes were prepared, and, finally, a trade-off analysis of the critical variables in the station planning was completed with recommendations to enhance the confidence in the measurement program.

EARTH ORBIT↗

Flow sensor for biomedical fluids

Electronic sensor accurately measures and controls flow of plasma, whole blood, or drugs in solution. Since sensor does not directly contact fluid, it does not have to be sterilized. It is compatible with disposable bottles, tubes, and hypodermic needles widely used in hospitals. Only modification necessary is in tube, which must contain two small metal inserts, spaced to fit in curved thermistor plates.

Winkler, H. E.↗

Biomedical and Human Factors Requirements for a Manned Earth-Orbiting Station

The study reported here has presented a measurement data pool for the determination of biomedical and behavioral effects of long-term exposure to weightlessness. This includes measures, techniques, equipment, and requirements in terms of weight, power, volume, time, crew activities, subsystem interfaces and experimental programs and designs, and confidence ratings for their effectiveness for determining weightlessness effects.

MANNED ORBITAL SPACE STATION /MOSS/↗

A coated-wire ion-selective electrode for ionic calcium measurements

A coated-wire ion-selective electrode for measuring ionic calcium was developed, in collaboration with Teknektron Sensor Development Corporation (TSDC). This coated wire electrode sensor makes use of advanced, ion-responsive polyvinyl chloride (PVC) membrane technology, whereby the electroactive agent is incorporated into a polymeric film. The technology greatly simplifies conventional ion-selective electrode measurement technology, and is envisioned to be used for real-time measurement of physiological and environment ionic constituents, initially calcium. A primary target biomedical application is the real-time measurement of urinary and blood calcium changes during extended exposure to microgravity, during prolonged hospital or fracture immobilization, and for osteoporosis research. Potential advanced life support applications include monitoring of calcium and other ions, heavy metals, and related parameters in closed-loop water processing and management systems. This technology provides a much simplified ionic calcium measurement capability, suitable for both automated in-vitro, in-vivo, and in-situ measurement applications, which should be of great interest to the medical, scientific, chemical, and space life sciences communities.

Hines, John W.↗

Improved Solid-State Microanemometer

Improved solid-state microanemometer suitable for measuring flows in variety of biomedical, industrial, and other applications. Small size, unique design, and one-piece construction provides combination of short response time, structural rigidity, optimal dissipation of heat, and versatility in application. Device includes four integral sensing resistors exposed to flow measured and serves as hot-film anemometer subunits. Sensing resistors connected to external excitation-and-measurement circuits operating in any of standard hot-film-anemometer modes; constant input voltage, constant input current, or constant resistance with feedback.

Henderson, H. Thurman↗

Polarimetric Glucose Sensing Using Brewster Reflection off of Eye Lens: Theoretical Analysis

An important task of in vivo polarimetric glucose sensing is to find an appropriate way to optically access the aqueous humor of the human eye. In this paper two different approaches are analyzed theoretically and applied to the eye model of Le Grand. First approach is the tangential path of Cote, et al. (G.L. Cot6, M.D. Fox, and R.B. Northrop: Noninvasive Optical Polarimetric Glucose Sensing Using a True Phase Measurement Technique. IEEE Transactions on Biomedical Engineering, vol. 39, no. 7, pp. 752-756, 1992.) and the second is a new scheme of this paper of applying Brewster reflection off the eye lens.

Boeckle, Stefan↗

Maintaining Skeletal Health During the Mission to Mars

Understanding how the effects of long-duration spaceflight (~6-months) might increase fracture risk in the younger-aged, physically-fit astronaut is challenging. Most of our skeletal data have been acquired from long-duration astronauts, crewmembers who typically serve on 120-180 day missions aboard the International Space Station (ISS). Astronaut biomedical data are predominantly 2-d measurements from DXA scans because this is a required clinical test at Johnson Space Center. Data from these clinical tests, and some data from research studies, are what NASA evaluates to define a risk for fracture in astronauts, both during a mission and long-term health. To date, the agency considers the risk for fracture during spaceflight to be of high (severe) consequence but of low probability (<0.1%) while the risk for fracture in during long-term health to be of medium consequence (interventions available) and medium probability (<1%). These risks are considered acceptable. Notably, there are minimal data to suggest that postflight fractures in long-duration astronauts are directly due to spaceflight exposure. Analyses by NASA epidemiologists and by biomedical engineers suggest that postflight fracture incidence in astronauts is consistent with a physically-active terrestrial population with no exposure to spaceflight. The epidemiological data to-date may be considered insufficient (low # and younger-aged subjects, limited follow-up time) to assess a fracture risk with reliability. In the absence of fracture evidence to substantiate a risk, it may be more useful to maintain astronauts at baseline (preflight) level of skeletal health during a mission. This lecture will present data from astronauts that affirms that 1) the maintenance of skeletal health during the future 3-year Mars mission will require an anti-resorptive therapy and 2) the risk for fracture during long-term health cannot be defined by the DXA clinical test alone.

Sibonga, Jean↗

Validation of Radio Frequency Telemetry Concept in the Presence of Biological Tissue-Like Stratified Media

In this paper we discuss a novel radio frequency (RF) telemetry concept for biomedical applications. The concept consists of a miniaturized spiral inductor/antenna for bio-MEMS sensors and an external pick-up antenna integrated into a handheld device. The measured relative signal strength in the presence of biological phantoms ranged from 5.9 to 7.5 dB for antenna separations of 5 and 10 cm. These relative signal strengths are easily measurable, therefore validating the RF telemetry concept for biomedical applications.

Miranda, Felix A.↗

Bone Analyzer

The danger of disuse osteoporosis under weightless condition in space led to extensive research into measurements of bone stiffness and mass by the Biomedical Research Division of Ames and Stanford University. Through its Technology Utilization Program, NASA funded an advanced SOBSA, a microprocessor-controlled bone probe system. SOBSA determines bone stiffness by measuring responses to an electromagnetic shaker. With this information, a physician can identify bone disease, measure deterioration and prescribe necessary therapy. The system is now undergoing further testing.

Source record↗

Preliminary Results from the Joint Russian and US Field Test: Measurement of Sensorimotor and Cardiovascular Responses Immediately Following Landing of the Soyuz Spacecraft

Ongoing collaborative research efforts between NASA's Neuroscience and Cardiovascular Laboratories, and the Institute of Biomedical Problems' (IBMP) Sensory-Motor and Countermeasures Laboratories have been measuring functional sensorimotor, cardiovascular and strength responses following bed rest, dry immersion, short duration (Space Shuttle) and long duration (Mir and International Space Station) space flights. While the unloading paradigms associated with dry immersion and bed rest have do serve as acceptable flight analogs, testing of crew responses following the long duration flights does not begin until a minimum of 24 hours after landing. As a result it is not possible to estimate the nonlinear trend of the early (<24 hr) recovery process nor is it possible to accurately assess the full impact of the decrements associated with long duration flight. To overcome these limitations both the Russian and U.S. sides have implemented testing at the time of landing and before the flight crews have left the landing site. By joint agreement this research effort has been identified as the functional Field Test (FT). For practical reasons the FT has been divided into two phases: the full FT and a preliminary pilot version (PFT) of the FT that is reduced in both length and scope. The primary goal of this research is to determine functional abilities in long duration space flight crews beginning as soon after landing as possible (< 2 hr) with one to three immediate follow-up measurements on the day of landing. This goal has both sensorimotor and cardiovascular elements including an evaluation of NASA's new anti-orthostatic compression garment as compared with the Russian Kentavr garment. Functional sensorimotor measurements will include, but are not limited to, assessment of hand/eye coordination, ability to egress from a seated position, walk normally without falling, measurement of dynamic visual acuity, ability to discriminate different forces generated with both the hands and legs, recovery from a fall, a coordinated walk involving tandem heel-to-toe placement and determination of postural ataxia while standing. The cardiovascular portion of the investigation includes blood pressure and heart rate measurements during a timed stand test in conjunction with postural ataxia testing. In addition to the immediate post-landing collection of data for the full FT, postflight data will be acquired at a minimum of one to three more other times within the 24 hr following landing and continue until functional sensorimotor and cardiovascular responses have returned to preflight normative values. The PFT represents a single trial run comprised of jointly agreed tests from the full FT and relies heavily on IBMP's Sensory-Motor and Countermeasures Laboratories for content, and implementation. The PFT is currently scheduled for the September 2013 landing of the Soyuz spacecraft (34S). Testing will include: (1) a sit-to-stand test, (2) recovery from a fall where the crewmember begins in the prone position on the ground and then stands for 3 min while cardiovascular stability is determined and postural ataxia data are acquired, and (3) a tandem heel-to-toe walk to determine changes in the central locomotor program. Video, cardiovascular parameters (heart rate and blood pressure), data from body-worn inertial sensors and severity of postflight motion sickness will be available for analysis. It is our intent to present, at this celebratory symposium, a summary of these data obtained from two crewmembers. In summary, the level of functional deficit is expected to be most profound during the acquisition of gravity loads immediately after landing when the demands for crew intervention in response to emergency operations will be greatest. Clearly measureable performance parameters such as ability to perform a seat egress, recover from a fall or the ability to see clearly when walking, and related physiological data (orthostatic responses) are required to provide an evidence base for characterizing programmatic risks and the degree of variability among crewmembers. Overall, these early functional and related physiological measurements will allow estimation of nonlinear sensorimotor and cardiovascular recovery trends to an accuracy that has not been previously captured in over 50 years of space flight.

Reschke, M. F.↗

Metabolic response of environmentally isolated microorganisms to industrial effluents: Use of a newly described cell culture assay

An environmental application using a microtiter culture assay to measure the metabolic sensitivity of microorganisms to petrochemical effluents will be tested. The Biomedical Operations and Research Branch at NASA JSC has recently developed a rapid and nondestructive method to measure cell growth and metabolism. Using a colorimetric procedure the uniquely modified assay allows the metabolic kinetics of prokaryotic and eukaryotic cells to be measured. Use of such an assay if adapted for the routine monitoring of waste products, process effluents, and environmentally hazardous substances may prove to be invaluable to the industrial community. The microtiter method as described will be tested using microorganisms isolated from the Galveston Bay aquatic habitat. The microbial isolates will be identified prior to testing using the automated systems available at JSC. Sodium dodecyl sulfate (SDS), cadmium, and lead will provide control toxic chemicals. The toxicity of industrial effluent from two industrial sites will be tested. An effort will be made to test the efficacy of this assay for measuring toxicity in a mixed culture community.

Ferebee, Robert N.↗