Adapting quantile mapping to bias correct solar radiation data
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Many data-driven planning methods are trained on data generated by planners. It is well known that many statistical learning methods are sensitive to sampling bias, and yet there has been little or no attention to planning as a sampling method and its role in introducing sampling bias into planner-generated training data. Recently, it has been demonstrated that A**,* in the presence of problems with variable heuristic error, prefers some solutions over other equally cost-optimal solutions. But, as we discuss in this paper, mitigation may not be as simple as resolving arbitrary tie-breaking by sampling from ties uniformly at random. In this paper, we formalize an intuition of planning bias. We focus on problems which output a single solution. Diverse planning only complicates the problem by generalizing it to bias in the set of sets; we show how it is subject to bias in the single solution. We make some useful observations about deterministic algorithms in contrast to non-deterministic algorithms. We explain how information entropy may be a good way to measure planning bias, and discuss some issues in evaluating practical approaches to measurement. We address the intuition that uniform random tiebreaking should mitigate bias; and sketch a novel approach to constructing an appropriate random distribution for duplicate detection during forward search for unbiased A*. Finally, we suggest directions for future work.
An investigation was conducted to determine the fore-and-aft elastic response characteristics of 34 x 9.9, type VII, 14 ply-rating aircraft tires of bias-ply, bias-belted, and radial-belted design. The investigation consisted of static and rolling tests on dry concrete pavements at the Langley aircraft landing loads and traction facility; statistical techniques which related the measured tire elastic characteristics to variations in the vertical load, inflation pressure, braking force and/or tire vertical deflection; and a semiempirical analysis which related the tire elastic behavior to measured wheel slippage during steady-state braking. The bias-belted tire developed the largest spring constant value for most loading conditions; the radial-belted tire, the smallest. The elastic response of the tire free periphery to static braking included both tread stretch and carcass torsional wind-up about the axle for the bias-ply and bias-belted tires and carcass wind-up alone for the radial-belted tire.
At SRON we are studying the performance of a Goddard Space Flight Center single pixel TES microcalorimeter operated in the AC bias configuration. For x-ray photons at 6keV the AC biased pixel shows a best energy resolution of 3.7eV, which is about a factor of 2 worse than the energy resolution observed in identical DC-biased pixels. To better understand the reasons of this discrepancy, we investigated the detector performance as a function of temperature, bias working point and applied magnetic field. A strong periodic dependence of the detector noise on the TES AC bias voltage is measured. We discuss the results in the framework of the recent weak-link behaviour observed inTES microcalorimeters.
A methodology is presented for estimating the urban bias of surface shelter temperatures due to the effect of the urban heat island. Multiple regression techniques were used to predict surface shelter temperatures based on the time period 1986-89 using upper-air data from the European Centre for Medium-Range Weather Forecasts (ECMWF) to represent the background climate, site-specific data to represent the local landscape, and satellite-derived data -- the normalized difference vegetation index (NDVI) and the Defense Meteorological Satellite Program (DMSP) nighttime brightness data -- to represent the urban and rural landscape. Local NDVI and DMSP values were calculated for each station using the mean NDVI and DMSP values from a 3 km x 3 km area centered over the given station. Regional NDVI and DMSP values were calculated to represent a typical rural value for each station using the mean NDVI and DMSP values from a 1 deg x 1 deg latitude-longitude area in which the given station was located. Models for the United States were then developed for monthly maximum, mean, and minimum temperatures using data from over 1000 stations in the U.S. Cooperative (COOP) Network and for monthly mean temperatures with data from over 1150 stations in the Global Historical Climate Network (GHCN). Local biases, or the differences between the model predictions using the observed NDVI and DMSP values, and the predictions using the background regional values were calculated and compared with the results of other research. The local or urban bias of U.S. temperatures, as derived from all U.S. stations (urban and rural) used in the models, averaged near 0.40 C for monthly minimum temperatures, near 0.25 C for monthly mean temperatures, and near 0.10 C for monthly maximum temperatures. The biases of monthly minimum temperatures for individual stations ranged from near -1.1 C for rural stations to 2.4 C for stations from the largest urban areas. The results of this study indicate minimal problems for global application once global NDVI and DMSP data become available.
At SRON we are studying the performance of a Goddard Space Flight Center single pixel TES microcalorimeter operated in an AC bias configuration. For x-ray photons at 6 keV the pixel shows an x-ray energy resolution Delta E(sub FWHM) = 3.7 eV, which is about a factor 2 worse than the energy resolution observed in an identical DC-biased pixel. In order to better understand the reasons for this discrepancy we characterized the detector as a function of temperature, bias working point and applied perpendicular magnetic field. A strong periodic dependency of the detector noise on the TES AC bias voltage is measured. We discuss the results in the framework of the recently observed weak-link behaviour of a TES microcalorimeter.
An investigation was conducted to determine the fore-and-aft elastic response characteristics of aircraft tires of bias ply, bias-belted, and radial-belted design. The investigation consisted of: (1)static and rolling tests, (2)a statistical analysis which related the measured tire elastic characteristics to variations in the vertical load, inflation pressure, braking force and/or tire vertical deflection, and (3) a semi-empirical analysis which related the tire elastic behavior to measured wheel slippage during a steady-state braking. The results of this investigation indicate that the bias-belted tire has the largest spring constant value for most loading conditions and the radial-belted tire has the smallest spring constant value.
MFI zeolites contain ten-membered ring channels (∼0.55 nm diameter) that intersect to form larger voids (∼0.70 nm diameter). The distribution of framework Al sites dictates the void environments that confine active H + sites. MFI synthesized with pentaerythritol (PET) and Na + as structure-directing agents are interrogated using kinetically controlled toluene methylation rates and xylene isomer selectivities. High para-xylene selectivity and low toluene methylation rates indicate that MFI-PET samples contain H + sites predominantly in smaller channels. As-synthesized samples contain more framework Al than Na + , indicating that some charge compensation is provided by protonated PET-solvent complexes that bias Al siting towards these smaller channels.
The emergence of global convective‐permitting models (GCPMs) represents a significant advancement in climate modeling, offering improved representation of deep convection and complex precipitation patterns. In this study, we evaluate the performance of the Simple Cloud‐Resolving E3SM Atmosphere Model (SCREAM) using its doubly periodic configuration (DP‐SCREAM) against large eddy simulations and modern observational data sets from the Atmospheric Radiation Measurement program. We introduce several new transitional cloud regime cases, such as the transition from shallow to deep convection and from stratocumulus to cumulus, as well as cold‐air outbreak scenarios. The results reveal both strengths and limitations of SCREAM, particularly in the accurate simulation of cloud transitions and midlevel convection, with varying degrees of sensitivity to horizontal and vertical resolution. Despite improvements at higher resolutions, key biases remain, including the abrupt transition from shallow to deep convection and the lack of congestus clouds. These findings underscore the need for further refinement in turbulence parameterizations and vertical grid resolution in GCPMs.
The orientation of triaxial galaxy clusters with respect to the line-of-sight is expected to be one of the prime sources of scatter and potential bias in optical observables (e.g., richness and weak-lensing signal) of galaxy clusters. In this work, we use the observed shape of the central Brightest Cluster Galaxy (BCG) as proxy for the orientation along the line-of-sight for clusters selected via the Sunyaev-Zel'dovich (SZ) effect from the South Pole Telescope (SPT) and Atacama Cosmology Telescope (ACT) surveys, matched to optically selected clusters from the Dark Energy Survey Year 3 (DES). We construct two samples of clusters that are designed to be identical in SZ mass estimate and redshift but with the roundest vs. the most elliptical BCGs, which we expect to correspond to BCGs (and clusters) with major axes aligned along the line-of-sight vs. in the plane of the sky, respectively. We find that the optical richness of round-BCG clusters is $\sim 10$% larger than that of elliptical-BCG clusters, in agreement with the expectation from projection effects and presenting the first such detection in data. The density profiles, however, are not in agreement with the expectation from projection effects: the 1-halo term (below $6~h^{-1}\rm{Mpc}$) of both the weak-lensing and galaxy density profiles are the same for the subsamples, contrary to previous studies based on X-ray selected clusters. In the 2-halo regime (above $6~h^{-1}\rm{Mpc}$), we find a significant excess of the elliptical-BCG cluster profiles compared to the round-BCG cluster profiles, which is the opposite of the expectation from numerical simulations. We hypothesize that the intrinsic shape of the BCG reflects not just the orientation angle, but also intrinsic properties of the cluster which can affect both the SZ signal and the amplitude of the 2-halo term.
No abstract available
Explore the source record for details and available documents.
Linear plasma devices (LPDs) are important experimental platforms for investigating plasma–material interactions (PMI). In PMI experiments, it has been found that applying a target bias not only effectively modifies the incident ion energy, but also induces significant changes in the electron density and electron temperature, whereby the evolution of these plasma parameters is primarily governed by plasma transport processes. However, at present, the physical process and mechanism underlying such bias-induced variations remain unclear. In this work, biasing experiments under argon plasma discharge conditions were first carried out on the MPS-LD device. For the corresponding experiments, an electric potential model was newly developed based on the BOUT++ LPD module, enabling self-consistent simulations of plasma transport under biased conditions. Numerical simulations were then performed to reproduce the experimental results and to validate the accuracy of the proposed model. Finally, by combining experimental measurements with numerical simulations, a bias-voltage scan was performed to investigate how the electron density and electron temperature vary with the bias voltage (U bias ). The results show that applying negative bias decreases the target electron density (n e,T ) while increasing the target electron temperature (T e,T ). In contrast, positive bias increases both n e,T and T e,T ; however, at high positive bias, n e,T first reaches a maximum and subsequently decreases with further increases in U bias . The underlying physical mechanisms are analyzed using particle flux, momentum, and energy conservation. It indicates that the applied bias regulates the parallel electric field, thereby changing ion and electron velocities, and consequently affecting the electron density. At high positive bias, the ion velocity is further influenced by ion viscosity, leading to the reversal in n e,T . Meanwhile, the enhanced parallel electric field drives stronger currents, significantly increasing ion–electron frictional work and converting the input bias power into electron energy, which raises the electron temperature. In conclusion, these results contribute to a deeper understanding of the effects and mechanisms of biasing on plasma transport in the MPS-LD device.
A low bias in carbon monoxide compared to observations at high latitudes is a common feature of chemistry climate models. CO bias can both indicate and contribute to a bias in modeled OH and methane lifetime. This study examines possible causes of CO bias in the ACCMIP simulation of the GEOSCCM, and considers how attributing the CO bias to uncertainty in CO emissions versus biases in other constituents impacts the relationship between CO bias and methane lifetime. We use a simplified model of CO tagged by source with specified OH to quantify the sensitivity of the CO bias to changes in CO emissions or OH concentration, comparing the modeled CO to surface and MOPITT observations. The simplified model shows that decreasing OH in the northern hemisphere removes most of the global mean and inter-hemispheric bias in surface CO. We then use results from this analysis to explore how adjusting CO sources in the CCM impacts the concentrations of ozone, OH and methane. The CCM simulation also exhibits biases in ozone and water vapor compared to observations. We use a parameterized CO-OH-CH4 model that takes ozone and water vapor as inputs to the parameterization to examine whether correcting water and ozone biases can alter OH enough to remove the CO bias. Through this analysis, we aim to better quantify the relationship between CO bias and model biases in ozone concentrations and methane lifetime.
Shortwave irradiance biases due to two- and four-stream approximations have been studied for the last couple of decades, but biases in estimating Earth’s radiation budget have not been examined in earlier studies. In order to quantify biases in diurnally-averaged irradiances, we integrate the two- and four-stream biases using realistic diurnal variations of cloud properties from Clouds and the Earth’s Radiant Energy System (CERES) synoptic (SYN) hourly product. Three approximations are examined in this study, delta-two-stream-Eddington (D2strEdd), delta- two-stream-quadrature (D2strQuad), and delta-four-stream-quadrature (D4strQuad). Irradiances computed by the Discrete Ordinates Radiative Transfer (DISORT) and Monte Carlo (MC) methods are used as references. The MC noises are further examined by comparing with DISORT results. When the biases are integrated with a one-day of solar zenith angle variation, regional biases of D2strEdd and D2strQuad reach up to 8 W/sq.m, while biases of D4strQuad reach up to 2 W/sq.m. When the biases are further averaged monthly or annually, regional biases of D2strEdd and D2strQuad can reach –1.5 W/sq.m in SW top-of-atmosphere (TOA) upward irradiances and +3 W/sq.m in surface downward irradiances. In contrast, regional biases of D4strQuad are within +0.9 for TOA irradiances and –1.2 W/sq.m for surface irradiances. Except for polar regions, monthly and annual global mean biases are similar, suggesting that the biases are nearly independent to season. Biases in SW heating rate profiles are up to –0.008 K/d for D2strEdd and –0.016 K/d for D2strQuad, while the biases of the D4strQuad method are negligible.
The majority of solid tantalum capacitors are produced by high-temperature sintering of a fine tantalum powder around a tantalum wire followed by electrolytic anodization that forms a thin amorphous Ta2O5 dielectric layer and pyrolysis of manganese nitrite on the oxide to create a conductive manganese dioxide electrode. A contact to tantalum wire is used as anode terminal and to the manganese layer as a cathode terminal of the device. This process results in formation of an asymmetric Ta -- Ta2O5 -- MnO2 capacitor that has different characteristics at forward (positive bias applied to tantalum) and reverse (positive bias applied to manganese cathode) voltages. Reverse bias currents might be several orders of magnitude larger than forward leakage currents so I-V characteristics of tantalum capacitors resemble characteristics of semiconductor rectifiers. Asymmetric I-V characteristics of Ta -- anodic Ta2O5 systems have been observed at different top electrode materials including metals, electrolytes, conductive polymers, and manganese oxide thus indicating that this phenomenon is likely related to the specifics of the Ta -- Ta2O5 interface. There have been multiple attempts to explain rectifying characteristics of capacitors employing anodic tantalum pentoxide dielectrics. A brief review of works related to reverse bias (RB) behavior of tantalum capacitors shows that the mechanism of conduction in Ta -- Ta2O5 systems is still not clear and more testing and analysis is necessary to understand the processes involved. If tantalum capacitors behave just as rectifiers, then the assessment of the safe reverse bias operating conditions would be a relatively simple task. Unfortunately, these parts can degrade with time under reverse bias significantly, and this further complicates analysis of the I-V characteristics and establishing safe operating areas of the parts. On other hand, time dependence of reverse currents might provide additional information for investigation of the processes under reverse bias conditions. In practice, there were instances when, due to unforeseen events, the system operated at conditions when capacitors experience periodically a relatively small reverse bias for some time followed by normal, forward bias conditions. In such a case an assessment should be made on the degree to which these capacitors are degraded by application of low-voltage reverse bias, and whether this degradation can be reversed by normal operating conditions. In this study, reverse currents in different types of tantalum capacitors were monitored at different reverse voltages below 15%VR and temperatures in the range from room to 145 C for up to 150 hours to get better understanding of the degradation process and determine conditions favorable to the unstable mode of operation. The reversibility of RB degradation has been evaluated after operation of the capacitors at forward bias conditions. The effect of reverse bias stress (RBS) on reliability at normal operating conditions was evaluated using highly accelerated life testing at voltages of 1.5VR and 2 VR and by analysis of changes in distributions of breakdown voltages. Possible mechanisms of RB degradation are discussed.
Detecting climate trends on large spatiotemporal scales requires accurate, stable measurements and stable retrieval algorithms. We strive to estimate how time-variant retrieval algorithm biases may impact trend detection. Here we focus on the 3D cloud optical thickness (τc) bias, which is among the largest in passive cloud retrieval algorithms. If this bias is time dependent, a possibility with potential decadal changes in cloud morphology, it may obscure genuine trends in τc. Although previous studies have evaluated the cloud- and sun-view geometry-dependent 3D τc bias on small spatial scales, before our current study none have evaluated the stability of this well-known bias on climate-relevant large spatiotemporal scales. These studies must estimate large scale distributions of the 3D τc bias by cloud type and estimate how cloud type amount may change between two climate states. We employ a novel approach to estimate large scale distributions of 3D τc using a proxy of the bias that quantifies the departure of clouds from satisfying the 1D radiative transfer assumption used in passive τc retrievals. This existing globally-distributed proxy is an angular consistency metric that was developed using fused Moderate-Resolution Imaging Spectroradiometer (MODIS) and Multi-angle Imaging Spectroradiometer (MISR) measurements. Calculating the 3D τc bias and the proxy, for known cloud fields enables us to establish statistical relationships between these two quantities, which can be used to calculate large-scale distributions of the 3D τc bias. This approach limits the number of 3D radiative transfer simulations required to only those needed to estimate a statistical relationship between the 3D τc bias for known cloud fields and a proxy of the bias. It is likely that future studies will be needed to evaluate retrieval algorithm bias stability for other geophysical variables as the community develops climate data records from satellite observations and their retrievals. This must be done in addition to monitoring and correcting measurement errors and uncertainties and understanding their impact on retrieved essential climate variables.
The electromagnetic (EM) bias epsilon is an error present in radar altimetry of the ocean surface due to nonuniform reflection with surface displacement. The electromagnetic bias is defined as the difference in height between the mean reflecting surface and the mean sea surface. A knowledge of the electromagnetic bias is required for reducing errors in mean sea level measurements by satellite radar altimeters. Direct measurements of the EM bias at 14 GHz (Ku band) and 5 GHz (C band) were made from an oil production platform in the Gulf of Mexico over a 6-month period during 1989 and 1990. A total of 1280 hours of usable data was collected. During the experiment the significant wave height (SWH) varied from 0.6 to 3.2 m; the wind speed at 25 m above the surface varied from 0.1 to 14.3 m/s; the Ku band bias varied from -1.0 to -13.8 cm, or from -1.6% to -5.3% of the SWH; and the C band bias varied from -0.4 to -19.9 cm, or from -0.6% to -6.3% of the SWH. The biases has mean values of -3.7% and -3.6% of SWH with standard deviations of the variability about the mean of 0.7% and 1.0% of the SWH for Ku and C bands, respectively. We found a nonlinear relationship between dimensionless bias (bias/SWH) and wind speed at both low and high wind speeds. For wind speeds less than 3-4 m/s but less than 10 m/s, both biases were found to increase linearly with wind speed. For wind speeds greater than 11-12 m/s, the C band bias reaches a maximum. The Ku band bias reaches a maximum and then begins to decrease for wind speeds greater than 9-10 m/s.