Electron beam diagnostics.

Spectroscopic electron beam diagnostic technique, examining negligible effect elevated vibrational temperatures have on measured rotational temperatures of molecular nitrogen

ELECTRON BEAM↗

A transmitted-beam diagnostic for the wavelength-tunable UV drive beam on OMEGA

A transmitted-beam diagnostic (P9TBD) was developed as part of a new experimental platform used to study laser–plasma interactions on OMEGA. Located in the opposing port to the wavelength-tunable (350 nm to 353 nm) UV drive beam, the P9TBD characterizes the beam after it propagates through an undersense plasma. The instrument consists of a large-aperture window that allows light to exit the target chamber and project onto a thin sheet of semi-transparent diffuser material. Light transmitted through the diffuser is recorded using a time-integrated camera and a fiber-optically coupled streaked spectrometer, providing measurements of the energy, power, fluence, polarization, and spectrum of the transmitted beam. Here, the diagnostic enables direct observation of a variety of cross-beam energy transfer phenomena, such as wavelength detuning, polarization effects, and gain saturation.

47 OTHER INSTRUMENTATION↗

Investigation of ion beam diagnostics final report

Ion beam diagnostics - plasma wind tunnel stream generation and characteristics, mercury optical resonance probe, environment effects on ion stream neutralization, and electric field meters

PLASMA GENERATION↗

AI-driven Neutrino Beam Diagnostics for Next-Generation Neutrino Experiments

The accelerator-driven beam uncertainty limits oscillation measurements in long-baseline neutrino experiments. Spill-resolved beam diagnostics and real-time inference are necessary to address these neutrino flux systematics. As such, we present a machine-learning-based beam monitoring framework developed and validated using data from the T2K experiment. Our approach uses downstream, spill-by-spill muon monitor observables to predict upstream parameters such as proton beam position and width. We achieve high predictive accuracy on nominal runs, demonstrating robust baseline performance whether the model is trained on stable runs or systematically varied conditions. The framework is designed to be robust against domain shifts, allowing the neural network architectures and inference strategies developed with T2K data to be retrained and validated using LBNF simulations, with the goal of eventual deployment under real LBNF/DUNE operating conditions. This scalable approach to real-time beam inference offers a pathway toward reducing flux systematics for next-generation neutrino experiments such as DUNE.

Aney, Noah [Fermilab; U. Chicago (main)]↗

DEVELOPMENT OF A QUANTUM ELECTRON BEAM DIAGNOSTIC APPARATUS

Spatial properties of electron beams are the essential parameters needed in particle physics and accelerator research. Beam characterization using optical detection methods through the interaction between photons and electrons such as Compton scattering, or electro-optic sampling of the electric field of electrons have been extensively explored and successfully implemented as non-invasive diagnostics at various accelerator facilities. However, such methods often suffer from inherently low sensitivity. Here we present the study of a new type of electron beam diagnostic device for direct optical imaging of electron beams at various energy levels. The concept is based on the extremely high sensitivity of atoms, prepared in a specific "dark superposition" quantum state, to the external electric or magnetic perturbations induced by the passing charged particle, which allows atoms to change polarization of the probe light or absorb probe light and to fluoresce, enabling direct 3D imaging of the charged particles with high resolution. We report our recent experiment results and the design effort on a compact apparatus intended to be tested with the relativistic electron beams at Jefferson Laboratory.

Zhang, S.↗

Advanced Laser-driven Plasma Accelerator Electron-beam Diagnostics with COTR Techniques

A significant advance in laser-driven plasma accelerator (LPA) electron-beam diagnostics has recently been demonstrated based on coherent optical transition radiation (COTR) imaging. We find COTR signal strengths from a microbunched subset of beam exiting the LPA to be several orders of magnitude higher than that of incoherent optical transition radiation (OTR). The transverse sizes are only a few microns as deduced from the point-spread-function-related lobe structure. In addition, the far-field COTR interferometric images obtained on the same shot provide beam-size limits plus divergence and pointing information at the sub-mrad level when compared to a modified analytical model. The integrated image intensities can be used to estimate the microbunching fraction and relatable to the LPA process. Initial results in a collaborative LPA experiment will be reported for electron beam energies of about 215 MeV. A revised configuration is proposed to record energy and ene rgy spread via COTR on the same shot with the interferometer.

43 PARTICLE ACCELERATORS↗

Precision beam diagnostics at the NuMI facility using muon monitor observations

The Neutrinos at the Main Injector (NuMI) facility at Fermilab delivers an intense neutrino beam for multiple experiments by producing pions that decay into neutrinos, muons, and other particles. Magnetic horns—the primary pion focusing elements in the NuMI beamline—exhibit predominantly linear optics, enabling a predictable relationship between the proton beam and the resulting pion and muon phase spaces. This study has two primary objectives: first, to evaluate and confirm the linearity of the horn focusing mechanism using analytical models and numerical simulations; and second, to demonstrate that key beam parameters—such as proton beam intensity, beam position on target, and horn current—can be extracted from muon monitor observations within this linear optics framework. Using a machine learning model trained on spill-by-spill muon monitor data, we infer the horn current with a precision of ±0.05%, the beam intensity with ±0.1%, and the beam position on target with ±0.018⁢ mm horizontally and ±0.013⁢ mm vertically. This approach provides a reliable cross-check of beam parameters, helping to reduce systematic uncertainties that are critical for future experiments such as the Deep Underground Neutrino Experiment, which will rely on the neutrino beam produced by the Long-Baseline Neutrino Facility.

Beam control↗

Laser and optical transport line for laser-based ion beam diagnostics and control in the SNS linear accelerator

We report our recent upgrade of the laser and optical transport line for the laser-based ion beam diagnostics (laser wire) system at the linear accelerator (linac) of the Spallation Neutron Source (SNS). A new light source based on diodepumped solid-state laser amplifiers has been developed to provide near diffraction-limited laser beam with a variety of pulse structures. The free-space optical transport line has been modified to include image relay optics with remote control, which greatly improved the laser beam quality and position stability at individual measurement stations. The upgraded system enables novel beam diagnostics/control capabilities including longitudinal profile measurement and high-energy proton beam extraction from the SNS linac.

Liu, Yun↗

On Possibilities of Using Edge Radiation for X-ray and Electron Beam Diagnostics at Bending Magnet Beamlines of NSLS-II

Spectral flux density distributions of long-wavelength Edge Radiation, i.e. radiation generated by relativistic electrons at edges of bending magnets in a storage ring are described, both analytically and numerically. Possibilities of using this radiation for the alignment of optical components of bending magnet beamlines at NSLS-II and for non-destructive X-ray and electron beam diagnostics at these beamlines are discussed.

43 PARTICLE ACCELERATORS↗

Conditional guided generative diffusion for particle accelerator beam diagnostics

Abstract Advanced accelerator-based light sources such as free electron lasers (FEL) accelerate highly relativistic electron beams to generate incredibly short (10s of femtoseconds) coherent flashes of light for dynamic imaging, whose brightness exceeds that of traditional synchrotron-based light sources by orders of magnitude. FEL operation requires precise control of the shape and energy of the extremely short electron bunches whose characteristics directly translate into the properties of the produced light. Control of short intense beams is difficult due to beam characteristics drifting with time and complex collective effects such as space charge and coherent synchrotron radiation. Detailed diagnostics of beam properties are therefore essential for precise beam control. Such measurements typically rely on a destructive approach based on a combination of a transverse deflecting resonant cavity followed by a dipole magnet in order to measure a beam’s 2D time vs energy longitudinal phase-space distribution. In this paper, we develop a non-invasive virtual diagnostic of an electron beam’s longitudinal phase space at megapixel resolution (1024 × 1024) based on a generative conditional diffusion model. We demonstrate the model’s generative ability on experimental data from the European X-ray FEL.

43 PARTICLE ACCELERATORS↗

Deployment and validation of predictive 6-dimensional beam diagnostics through generative reconstruction with standard accelerator elements

Understanding the 6-dimensional phase space distribution of particle beams is essential for optimizing accelerator performance. Conventional diagnostics such as use of transverse deflecting cavities offer detailed characterization but require dedicated hardware and space. Generative phase space reconstruction (GPSR) methods have shown promise in beam diagnostics, yet prior implementations still rely on such components. Here we present the first experimental implementation and validation of the GPSR methodology, realized by the use of standard accelerator elements including accelerating cavities and dipole magnets, to achieve complete 6-dimensional phase space reconstruction. Through simulations and experiments at the Pohang Accelerator Laboratory X-ray Free Electron Laser facility, we successfully reconstruct complex, nonlinear beam structures. Furthermore, we validate the methodology by predicting independent downstream measurements excluded from training, revealing the reconstruction closely resembling ground truth. This advancement establishes a pathway for predictive diagnostics across beamline segments while reducing hardware requirements and expanding applicability to various accelerator facilities.

Kim, Seongyeol [Pohang Univ. of Science and Techno↗

Machine Learning for LBNF Beam Diagnostics

This paper focuses on developing a machine learning model for predicting initial beam parameters for the Long Baseline Neutrino Facility (LBNF) beamline using downstream muon monitor data. Parameters such as proton beam position on target, sigma on target, focusing horn current, and focusing horn tilt are parameters we anticipate to be predictable based on the muon monitors. Uncertainty in initial beam condition measurements are a major contributor to uncertainty in downstream flux, and over operation time beam misalignment can occur [1]. A machine learning model has promise to detect anomalies along the beamline based on discrepancies between predicted configurations and measured configurations, and thus can expedite error detection and handling. A PyTorch neural network is defined, trained, and tested. The developed model currently does not provide reliable predictions, with the lowest loss being 0.09.. Further steps to improve the model’s accuracy are discussed, as well as future plans to detect anomalous beam conditions using a digital twin.

O'Brien, Bridget [Fermilab]↗

Low Energy Muon Beam Diagnostics: Scintillating Fiber Profile Monitor

The MeV Test Area (MTA) houses the 400 MeV H- Beam at the end of the Linac and a secondary beamline of muons and pions created from hitting a Tungsten target. The MTA is in the Irradiation Test Area (ITA), where experiments involve studying the effects of radiation on materials in the MTA beam. There is a need for a retractable detector to monitor the secondary beam’s intensity and coarse profile. The SFPM was chosen when considering factors like ability to measure low rates and handle high intensities. The plan was to test different scintillating fibers & Silicon Photomultiplier (SiPM) models to figure out which combination gives the best signals, and gain familiarity with the detector assembly, operation, and data acquisition software before using with final detectors in beamline. The SiPM circuit has been tested with a LED pulser successfully. The immediate steps that follow will be to set the SiPM up on the monitor with three different types of optical fibers, use the Caen software to configure the best mode of data acquisition, and proceed with an offline source test using Strontium-90. Once the most efficient measurement method is clear, they will be ready for use in the beamline.

Leith, Justin↗

Low Energy Muon Beam Diagnostics - Scintillating Fiber Profile Monitor (SFPM)

The MeV Test Area (MTA) houses the 400 MeV H^− Beam at the end of the Linac and a secondary beamline of muons and pions created from hitting a Tungsten target. The MTA is in the Irradiation Test Area (ITA), where experiments involve studying the effects of radiation on materials in the MTA beam. There is a need for a retractable detector to monitor the secondary beam s intensity and coarse profile. The SFPM was chosen when considering factors like ability to measure low rates and handle high intensities. The plan was to test different scintillating fibers & Silicon Photomultiplier (SiPM) models to figure out which combination gives the best signals, and gain familiarity with the detector assembly, operation, and data acquisition software before using with final detectors in beamline. The SiPM circuit has been tested with a LED pulser successfully. The immediate steps that follow will be to set the SiPM up on the monitor with three different types of optical fibers, use the Caen software to configure the best mode of data acquisition, and proceed with an offline source test using Strontium-90. Once the most efficient measurement method is clear, they will be ready for use in the beamline.

Leith, Justin↗

Recent progress in laser wire-based H- beam diagnostics at the SNS linac

Laser wire has been used for nonintrusive profile and emittance measurements of operational hydrogen ion (H-) beam at the SNS linac. In this talk, we will describe the following recent developments in the laser wire system. 1) An upgraded light source and laser transport line which enables novel measurement capabilities including longitudinal profile measurement and high-energy proton beam extraction over potentially an entire macropulse. 2) A dual-detector emittance measurement scheme that boosted the dynamic range by an order of magnitude. 3) Design and implementation laser-wire-based nonintrusive longitudinal phase space measurement system.

Liu, Yun↗