Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Beam Forming”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Systems and methods for laser processing of solid-state batteries

The present disclosure relates to a system for laser processing of a ceramic electrolyte material. The system may include a controller, a laser responsive to the controller for generating a beam, and a beam forming subsystem. The beam forming subsystem controls a parameter of the beam generated by the laser. The beam forming subsystem further controls the beam to provide a laser fluence sufficient to produce densification of the ceramic electrolyte material.

Ye, Jianchao↗

System and method for microwave volumetric additive manufacturing

The present disclosure relates to a volumetric additive manufacturing system for forming a structure from a volume of resin using microwave energy. The system makes use of an electronic controller and at least one beam forming algorithm accessible by the electronic controller for generating information relating to an amplitude and a time delay for forming a microwave signal, where the microwave signal will be used in irradiating a build volume, and where the build volume is formed by the volume of resin. A microwave signal generating subsystem is included which is responsive to the information generated by the beam forming algorithm, and which generates a microwave signal using the amplitude and the time delay determined by the beam forming algorithm. An antenna is used to receive the microwave signal and project the microwave signal as a microwave beam, in accordance with the amplitude and time delay, into the build volume to form the structure.

Mukherjee, Saptarshi↗

Commissioning the H i Observing Mode of the Beam Former for the Cryogenically Cooled Focal L-band Array for the GBT (FLAG)

We present the results of commissioning observations for a new digital beam-forming back end for the Focal plane L-band Array for the Robert C. Byrd Green Bank Telescope (FLAG), a cryogenically cooled Phased Array Feed (PAF) with the lowest measured T {sub sys}/η of any PAF outfitted on a radio telescope to date. We describe the custom software used to apply beam-forming weights to the raw element covariances to create research-quality spectral-line images for the new fine-channel mode, study the stability of the beam weights over time, characterize FLAG’s sensitivity over a frequency range of 150 MHz, and compare the measured noise properties and observed distribution of neutral hydrogen emission from several extragalactic and Galactic sources with data obtained with the current single-pixel L-band receiver. These commissioning runs establish FLAG as the preeminent PAF receiver currently available for spectral-line observations on the world’s major radio telescopes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

The FRB-searching Pipeline of the Tianlai Cylinder Pathfinder Array

This paper presents the design, calibration, and survey strategy of the Fast Radio Burst (FRB) digital backend and its real-time data processing pipeline employed in the Tianlai Cylinder Pathfinder Array. The array, consisting of three parallel cylindrical reflectors and equipped with 96 dual-polarization feeds, is a radio interferometer array designed for conducting drift scans of the northern celestial semi-sphere. The FRB digital backend enables the formation of 96 digital beams, effectively covering an area of approximately 40 square degrees with the 3 dB beam. Our pipeline demonstrates the capability to conduct an automatic search of FRBs, detecting at quasi-real-time and classifying FRB candidates automatically. The current FRB searching pipeline has an overall recall rate of 88%. During the commissioning phase, we successfully detected signals emitted by four well-known pulsars: PSR B0329+54, B2021+51, B0823+26, and B2020+28. We report the first discovery of an FRB by our array, designated as FRB 20220414A. We also investigate the optimal arrangement for the digitally formed beams to achieve maximum detection rate by numerical simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

All-Dielectric Meta-Optics for High-Efficiency Independent Amplitude and Phase Manipulation

Optical metasurfaces, composed of subwavelength scattering elements, demonstrate remarkable control over the transmitted amplitude, phase, and polarization of light. However, manipulating the amplitude upon transmission, without the use of surface waves, requires loss if a single metasurface is used. Herein, high-efficiency independent manipulation of the amplitude and phase of a beam is described using two lossless phase-only metasurfaces separated by a distance. With this configuration, optical components such as combined beam-forming and splitting devices are experimentally demonstrated, as well as those for forming complex-valued, 3D holograms. The compound meta-optic platform provides a promising approach for achieving high-performance holographic displays and compact optical components, while exhibiting a high overall efficiency.

42 ENGINEERING↗

Roadmap for Optical Metasurfaces

Metasurfaces have recently risen to prominence in optical research, providing unique functionalities that can be used for imaging, beam forming, holography, polarimetry, and many more, while keeping device dimensions small. Despite the fact that a vast range of basic metasurface designs has already been thoroughly studied in the literature, the number of metasurface-related papers is still growing at a rapid pace, as metasurface research is now spreading to adjacent fields, including computational imaging, augmented and virtual reality, automotive, display, biosensing, nonlinear, quantum and topological optics, optical computing, and more. At the same time, the ability of metasurfaces to perform optical functions in much more compact optical systems has triggered strong and constantly growing interest from various industries that greatly benefit from the availability of miniaturized, highly functional, and efficient optical components that can be integrated in optoelectronic systems at low cost. This creates a truly unique opportunity for the field of metasurfaces to make both a scientific and an industrial impact. Furthermore, the goal of this Roadmap is to mark this “golden age” of metasurface research and define future directions to encourage scientists and engineers to drive research and development in the field of metasurfaces toward both scientific excellence and broad industrial adoption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fabrication of the Fermilab Pre-Series Cold Mass for the HL-LHC Accelerator Upgrade Project

Fermilab is fabricating ten full length cold masses for the high-luminosity Large Hadron Collider Accelerator Upgrade Project (HL-LHC AUP). One practice assembly and one pre-series assembly have been completed. Here this paper summarizes the construction details. Topics include incoming inspection, bus assembly, component machining, shell forming, beam tube insertion, bus expansion loop installation, instrumentation installation, electrical testing, heat exchanger installation and final assembly welding. In-process surveys, alignment measurements and testing are presented and explained. Problems encountered during construction and their solutions are discussed.

43 PARTICLE ACCELERATORS↗

Science Applications of Phased Array Radars

Phased array radars (PARs) are a promising observing technology, at the cusp of being available to the broader meteorological community. PARs offer near instantaneous sampling of the atmosphere with flexible beam forming, multi-functionality, low operational and maintenance costs, and without mechanical inertia limitations. These PAR features are transformative compared to those offered by our current reflector-based meteorological radars. The integration of PARs into meteorological research has the potential to revolutionize the way we observe the atmosphere. The rate of adoption of PARs in research will depend on many factors including i) the need to continue educating the scientific community on the full technical capabilities and trade-offs of PARs through an engaging dialogue with the science and engineering communities and ii) the need to communicate the breadth of scientific bottlenecks that PARs can overcome in atmospheric measurements and the new research avenues that are now possible using PARs in concert with other measurement systems. The former is the subject of a companion article that focuses on PAR technology while the latter is the objective here.

54 ENVIRONMENTAL SCIENCES↗

Arrays of glass wedges for multi-dimensional optical diagnostics

There is a common need in the advancement of optical diagnostic techniques to increase the dimensionality of measurements. For example, point measurements could be improved to multi-point, line, planar, volumetric, or time-resolved volumetric measurements. In this work, a unique optical element is presented to enable multi-dimensional measurements, namely, an array of glass wedges. A light source is passed through the wedges, and different portions of the illumination are refracted by different amounts depending on the glass wedge angle. Subsequent optics can be used to focus the light to multiple points, lines, or planes. Basic characterization of a glass wedge array is presented. Additional wedge-array configurations are discussed, including the use of a periodic intensity mask for multi-planar measurements via structured illumination. The utility of this optical element is briefly demonstrated in (a) multi-planar flame particulate measurements, (b) multi-point femtosecond-laser electronic excitation tagging for flow velocimetry, and (c) multi-line nitric oxide molecular tagging velocimetry in a hypersonic shock-tunnel. One significant advantage of this optical component is its compatibility with high-energy laser sources, which may be a limiting factor with other beam-splitting or beam-forming elements such as some diffractive optics. Additionally, an array of glass wedges is simple and easily customizable compared to other methods for forming multiple closely spaced illumination patterns. In conclusion, suggestions for further development and applications are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Convergence of Emerging Technologies - OWL Test Results

The OWL GroundAware GA1360 2D radar system with advertised capability of advanced digital beam-forming radar technology, classification intelligence, reconfigurability, and easy integration with other security systems to bring 360° of real-time, all-weather situational awareness for the physical security of perimeters and other sensitive areas for critical infrastructure.

47 OTHER INSTRUMENTATION↗

Notes on Tapered Active Array Antenna Performance

Modern Active Electronically Steerable Array (AESA) antennas offer substantial control over transmit and receive antenna beam forming, including via elemental weighting to achieve a desired tapered aperture. However, these tapers also have the adverse side effect of diminishing total transmitted power and/or raising the system noise figure. This is readily calculated, and must be considered for overall radar performance prediction. Independent tapers for transmit and receive arrays might be play.

42 ENGINEERING↗

Notes on Complex (Including Phase-Only) Tapered Active Array Antenna Performance

Modern Active Electronically Steerable Array (AESA) antennas offer substantial control over transmit and receive antenna beam forming, including via elemental weighting to achieve a desired tapered aperture. Elemental taper weighting may generally be complex, with both amplitude and phase components. This includes phase-only tapers. However, array tapers may also have the adverse side effect of diminishing transmit and/or receive effectiveness. This is readily calculated, and must be ...

Doerry, Armin Walter [Sandia National Laboratories↗

A compact dication source for Ba 2+ tagging and heavy metal ion sensor development

Here, we present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the retention time in the ionization region. Barium, lead, and cadmium samples have been used to test the system, with ion currents identified and quantified using a quadrupole mass analyzer. Realization of a clean Ba 2+ ion beam within a bench-top system represents an important technical advance toward the development and characterization of barium tagging systems for neutrinoless double beta decay searches in xenon gas. This system also provides a testbed for investigation of novel ion sensing methodologies for environmental assay applications, with dication beams of Pb 2+ and Cd 2+ also demonstrated for this purpose.

47 OTHER INSTRUMENTATION↗

System and method for sub micron additive manufacturing

An apparatus is disclosed for performing an additive manufacturing operation to form a structure by processing a photopolymer resist material. The apparatus may incorporate a laser for generating a laser beam, and a tunable mask for receiving the laser beam which has an optically dispersive element. The mask splits the laser beam into a plurality of emergent beams each having a subplurality of beamlets of varying or identical intensity, with each beamlet emerging from a unique subsection of illuminated regions of the mask. A collimator collimates at least one of the emergent beams to form a collimated beam. One or more focusing elements focuses the collimated beam into a focused beam which is projected as a focused image plane on or within the resist material. The focused beam simultaneously illuminates a layer of the resist material to process an entire layer in a parallel fashion.

Saha, Sourabh Kumar↗

Identification and time evolution of thionyl chloride (SOCl 2 ) radiolysis products

In this study, innovative solutions are needed to reduce the amount of high-level waste generated by used nuclear fuel recycling strategies to support the widespread adoption of sustainable nuclear fission energy technologies. To this end, a new sulfur chloride-based process has been developed to recycle zirconium alloy-based materials, which make up a significant fraction of high-level radioactive waste. To support the continued development of this process, we present new data on the potential reaction pathways over time of the products arising from the gamma and electron beam radiolysis of neat thionyl chloride (SOCl 2 ). Interrogation of the gamma irradiated liquid by Raman spectroscopy provided more conclusive identification of the SOCl 2 degradation products, specifically sulfur dichloride (SCl 2 ), molecular chlorine (Cl 2 ), sulfur dioxide (SO 2 ), and sulfuryl chloride (SO 2 Cl 2 ). In comparison, the high dose rate (~10 7 Gy s -1 ) electron beam irradiations formed significantly more degradation products. For both cobalt-60 gamma and electron beam irradiations, the observed degradation products were found to evolve as a function of time post-irradiation via the same reaction pathways, with indication of a solvent regeneration mechanism. These findings are fortuitous for process development, as such a mechanism would be beneficial for process longevity and cost effectiveness.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗