Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Be cavity design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Compact Crab Cavity Design (Final Report)

The goal of this project is to provide an innovative, new crab cavity design relevant to the MEIC. Through this work, we will provide comprehensive modeling of this new cavity design, including electromagnetic, thermal, and microphonic effects. One most likely candidate configuration is the design put forward by JLab and Lancaster University, UK, researchers known as the four-rod configuration. In the Phase I, Tech-X Corporation researchers performed analysis and design optimization and iteration, utilizing their state-of-the art time-domain particle-in-cell software, on a 400 MHz design for the LHC by JLab and Lancaster University, UK, researchers known as the four-rod design.

43 PARTICLE ACCELERATORS↗

Asymmetrical cavity design that bypasses mode mixings in axion haloscope experiments

Microwave cavities used in axion haloscope experiments typically employ a tuning rod as a means to widen the range of resonance frequencies at which it is sensitive to axion-to-photon conversion. A realistic tuning mechanism requires a gap between the cavity end caps and the tuning rod to ensure movement, and causes some modes to hybridize with the resonant mode that is being tracked for the experiment. These so-called mode mixings lead to gaps in the frequency range that practically lose sensitivity to axions. Here, to solve this problem, we present a cavity design which, for two tuning rod configurations corresponding to a lower and higher frequency range, have a dielectric rod inserted at a specific location that makes the cavity asymmetrical. Moving the tuning rod closer to the dielectric insert changes the location and frequency of the mode mixing compared to when it is farther away from it. This design is easily realizable in practical experiments and makes possible an axion dark matter search with minimal loss in sensitivity due to mode mixings. We also show that the same design has the same desired effect when cavity dimensions are scaled down to be smaller and are at higher resonance frequencies.

Axion↗

Progress on a Be Cavity Design

Previous RF experiments with normal-conducting cavities have demonstrated that there is a significant degradation in maximum gradient when the cavity is subjected to a strong axial magnetic field. We have developed a model suggesting that a cavity with beryllium walls may perform better than copper cavities. In this paper we outline the issues that led us to propose fabricating a Be-wall cavity. We also discuss a concept for fabricating such a cavity and mention some of the manufacturing issues we expect to face.

43 PARTICLE ACCELERATORS↗

First Considerations Concerning an Optimized Cavity Design for the Main Linac of BERLinPro

The Berlin Energy Recovery Linac Project (BERLinPro) is designed to develop and demonstrate CW linac technology and expertise required to drive next-generation Energy Recovery Linacs. Strongly HOM-damped multicell 1.3 GHz cavities are required for the main linac. The optimization of the cavities presented here is primarily based on the CEBAF 1.5 GHz 5-cell high-current cavity design, including HOM waveguide couplers. The cavity was scaled to 1.3 GHz and extended to 7 cells. Modifications to the end group design have also been studied. An effort was also made to reduce the ratio Epk/Eacc while still permitting HOMs to propagate.

43 PARTICLE ACCELERATORS↗

DOUBLE QUARTER WAVE DEFLECTOR CAVITY DESIGN & SIMULATION

A Double Quarter Wave (DQW) Cavity has been designed, tested and installed for use in longitudinal measurements as part of a diagnostic beamline. This report will describe the design and testing used to characterize this cavity before its use in the study of a magnetized electron beam.

Stefani, M.↗

Effects of various cavity designs on the performance of a CO2 TEA laser with an unstable resonator

Unstable resonator modeling has been carried out for an injection-seeded CO2 transversely excited atmosphere (TEA) laser in the NOAA/ERL/Wave Propagation Laboratory (WPL) Doppler lidar to examine the effects of various cavity designs on the quality of the output beam. The results show the effects of an injection pinhole, electrode spacing, mirror tilt, and radial reflectivity function of the output coupler. The electrode spacing in this laser has negligible effect. The injection pinhole, however, produces complicated structures in the output patterns. If the pinhole is removed, the output pattern is much smoother, and the frequency jitter is smaller. Misalignment sensitivity is very closely related to the radial reflectivity function. The superparabolic function provides the highest coupling efficiency, largest beam size, and good collimation, but produces a slightly higher misalignment sensitivity compared with a parabolic function. The Gaussian function provides the lowest misalignment sensitivity, but it produces the smallest beam size and the largest beam divergence. Also, the coupling coefficient is 50 percent lower than the optimum value. Methods for using a flat diffraction grating in unstable resonators are also investigated. The best way is to use a flat grating/positive lens combination to replace the back concave mirror.

Zhao, Yanzeng↗

The Influence of Cavity Design on the Linewidth of Near-IR Single-Mode Vertical-Cavity Surface-Emitting Lasers

The studies of the emission linewidth for single-mode near-IR vertical-cavity surface-emitting lasers with an active region based on InGaAs/AlGaAs quantum wells and different optical microcavity design. For low mirror loss, lasers with a 1λ cavity and carrier injection through distributed Bragg reflectors demonstrate a linewidth of 70 MHz and its growth to 110 MHz with increasing mirror loss (corresponding differential of efficiency ∼0.65 W/A). The design of the optical cavity with carrier injection through intracavity contacts and low-Q composition Bragg lattices reduces the linewidth to 40 MHz in spite of high mirror loss (corresponding differential efficiency of ∼0.6 W/A).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High current SRF cavity design for SPL and eRHIC

A high current five-cell Nb superconducting cavity, called BNL3 cavity, was optimized and designed for the SPL and eRHIC. For the fundamental mode, the optimization process aimed at maximizing the R/Q of the fundamental mode and the geometry factor G under an acceptable RF field ratio level of B{sub peak}/E{sub acc} and E{sub peak}/E{sub acc}. For higher order modes, the optimization is to lower (R/Q)Q{sub ext} for dipole and quadrupole modes to suppress the beam-break-up (BBU). To extract the HOM power out of the cavity, the BNL3 cavity employs a larger beam pipe, allowing the propagation of HOMs, but not the fundamental mode. Six HOM couplers (three at each end) are used to extract large HOM power. To avoid the cross-talk between cavities, tapers are employed between the cavities. This paper presents the design of the BNL3 cavity, end groups and BBU simulation results.

43 PARTICLE ACCELERATORS↗

Systematic cavity design approach for a multi-frequency gyrotron for DEMO and study of its RF behavior

High frequency (>230 GHz) megawatt-class gyrotrons are planned as RF sources for electron cyclotron resonance heating and current drive in DEMOnstration fusion power plants (DEMOs). In this paper, for the first time, a feasibility study of a 236 GHz DEMO gyrotron is presented by considering all relevant design goals and the possible technical limitations. A mode-selection procedure is proposed in order to satisfy the multi-frequency and frequency-step tunability requirements. An effective systematic design approach for the optimal design of a gradually tapered cavity is presented. The RF-behavior of the proposed cavity is verified rigorously, supporting 920 kW of stable output power with an interaction efficiency of 36% including the considerations of realistic beam parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and performance of a new induction furnace for heat treatment of superconducting radiofrequency niobium cavities

Superconducting radio frequency (SRF) cavities made of high purity niobium (Nb) are the building blocks of many modern particle accelerators. The fabrication process includes several cycles of chemical and heat treatment at low ({approx}120 Degree-Sign C) and high ({approx}800 Degree-Sign C) temperatures. In this contribution, we describe the design and performance of an ultra-high-vacuum furnace which uses an induction heating system to heat treat SRF cavities. Cavities are heated by radiation from the Nb susceptor. By using an all-niobium hot zone, contamination of the Nb cavity by foreign elements during heat treatment is minimized and allows avoiding subsequent chemical etching. The furnace was operated up to 1400 Degree-Sign C with a maximum pressure of {approx}1 Multiplication-Sign 10{sup -5} Torr and the maximum achievable temperature is estimated to be higher than 2000 Degree-Sign C. Initial results on the performance of a single cell 1.5 GHz cavity made of ingot Nb heat treated at 1200 Degree-Sign C using this new induction furnace and without subsequent chemical etching showed a reduction of the RF losses by a factor of {approx}2 compared to cavities made of fine-grain Nb which underwent standard chemical and heat treatments.

43 PARTICLE ACCELERATORS↗

Superconducting Cavity Design for Short-Pulse X-Rays at the Advanced Photon Source

Superconducting cavities have been analyzed for the short-pulse x-ray (SPX) project at the Advanced Photon Source (APS). Due to the strong damping requirements in the APS storage ring, single-cell superconducting cavities have been designed. The geometry has been optimized for lower-order and higher-order mode damping, reduced peak surface magnetic fields, and compact size. The integration of the cavity assembly, with dampers and waveguide input coupler, into a cryomodule will be discussed.

43 PARTICLE ACCELERATORS↗

Progress on a Be Cavity Design

Previous RF experiments with normal-conducting cavities have demonstrated that there is a significant degradation in maximum gradient when the cavity is subjected to a strong axial magnetic field. We have developed a model suggesting that a cavity with beryllium walls may perform better than copper cavities. In this paper we outline the issues that led us to propose fabricating a Be-wall cavity. We also discuss a concept for fabricating such a cavity and mention some of the manufacturing issues we expect to face.

43 PARTICLE ACCELERATORS↗

802 MHz ERL Cavity Design and Development

In the framework of a collaboration between CERN and JLab, an SRF accelerating cavity for energy recovery linacs operating at 802 MHz was developed in the context of the CERN's Large Hadron electron Collider (LHeC) design study. A single-cell and a five-cell cavity from fine grain high RRR niobium were built at JLab to validate the basic RF design in vertical tests. Two copper single-cell cavities were produced in parallel for R&D purposes at CERN. The cavity design has since been adapted as baseline for the main linac cavities in the proposed Powerful Energy Recovery Linac Experiment facility (PERLE) at Orsay. Details concerning the cavity fabrication and test results for the Nb cavities are presented.

Marhauser, Frank↗

197 MHz Waveguide Loaded Crabbing Cavity Design for the Electron-Ion Collider

The Electron-Ion Collider requires several crabbing sys-tems at both hadron storage ring and electron storage ring in order to reach the desired luminosity goal. The 197 MHz crabbing cavity system is one of the critical rf sys-tems of the collider. The crab cavity based on the rf-dipole design explores the option of waveguide load damping in suppressing the higher order modes and to meet the tight impedance specifications. The cavity is designed with compact dogbone waveguides with transi-tions to rectangular waveguides and waveguide loads. This paper presents the compact 197 MHz crab cavity design with waveguide damping and other ancillaries.

De Silva, S.U.↗

An improvement in blackbody cavity design

Setting the axis of the conical cavity at an angle to the axis of observation removes the imperfection at the apex of the cone from the direct observation area of the radiometer. Fillet no longer behaves as a nonuniformity in the blackbody.

Schmidt, R. M.↗

Folded cavity design for a ruby resonator

A folded cavity laser resonator operating in the TEM(00) mode has been built and tested. The new oscillator configuration leads to an increase in efficiency and to better line narrowing due to the increased number of passes through the laser rod and tuning elements, respectively. The modification is shown to lead to cavity ruggedization.

Arunkumar, K. A.↗

CLIC Crab Cavity Design Optimisation for Maximum Luminosity

The bunch size and crossing angle planned for CERN's compact linear collider CLIC dictate that crab cavities on opposing linacs will be needed to rotate bunches of particles into alignment at the interaction point if the desired luminosity is to be achieved. Wakefield effects, RF phase errors between crab cavities on opposing linacs and unpredictable beam loading can each act to reduce luminosity below that anticipated for bunches colliding in perfect alignment. Unlike acceleration cavities, which are normally optimised for gradient, crab cavities must be optimised primarily for luminosity. Accepting the crab cavity technology choice of a 12 GHz, normal conducting, travelling wave structure as explained in the text, this paper develops an analytical approach to optimise cell number and iris diameter.

43 PARTICLE ACCELERATORS↗