Cell degradation quantification—a performance metric-based approach

A safe and reliable battery operation needs effective diagnostic tools. A quantitative failure analysis (FA) to enable cell qualification and quantify its effectiveness for reliable and safe operation of rechargeable Li batteries (RLB) is shown here. The method can identify and quantify potential failure based on the state of charge (SOC) under any operating conditions. A precise and accurate electrochemical analytic diagnosis (eCAD) of 14 rechargeable Li || NMC622 cells of the same build are used as an example. The FA by eCAD can quantitatively decipher good, bad and ugly cells in cycle aging. The cell qualification is based on thermodynamic SOC, not experimental conditions. The method provides a quantitative failure mode and effect analysis (FMEA) to reveal diverse “dead Li” formation that affects the reversibility of the Li anode and charge retention in the cell. This cell qualification method highlights the potential to improve cell quality for safe operation, with strong implications for early fault detection, FA, risk mitigation, state estimation and life prediction for reliable and safe RLB operations

25 ENERGY STORAGE↗

Chapter 8: Life-Cycle Testing and Analysis

Prior to a spacecraft launch, program mission assurance standards dictate that the flight battery power system should comply with mission requirements under the intended operating conditions. Ground life cycle testing (LCT) combined with an analysis on the electrical power system (EPS) battery is an empirical method used to demonstrate compliance to satellite service life requirements. The LCT compliance method adopted by the aerospace industry is based on demonstrating a space battery's life expectancy as a part of battery qualification. Real-time cell and lithium-ion battery (LIB) LCT data are commonly used for model inputs to EPS power and energy balance analyses, in LIB reliability analysis estimates, and to support on-orbit spacecraft mission life extension opportunities. This chapter describes the LCT planning steps, process approach, and analysis techniques commonly used to qualify space LIB power systems.

accelerated aging↗

Energy storage cell qualification and related systems, methods, and devices

Energy storage cell qualification and related systems, methods, and devices are disclosed. A method of qualifying rechargeable battery cells includes taking measurements on the rechargeable battery cells, determining specific capacity distributions of the rechargeable battery cells as a function of a number of discharge cycles based on the measurements, determining one or more specific capacity thresholds to separate the specific capacity distributions of the rechargeable battery cells into two or more classifications, and qualifying the rechargeable battery cells into the two or more classifications based, at least in part, on the specific capacity distributions and the one or more specific capacity thresholds. A method of implementing rechargeable battery cells into product manufacturing and qualifying the rechargeable battery cells, and deploying those of the rechargeable battery cells qualified into a first classification of the two or more classifications into the product.

Liaw, Boryann↗

Equipment Qualification Report Environmental Qualification of GNB Absolyte Valve Regulated Lead Acid (VRLA) 1600 Ah100G33 Battery Rack Assembly (24590-QL-POA-EDB0-00001-11-00002_00A)

Greenberry Environmental Qualification Report 550001.001-35.0.5 provides basis for assignment of qualified life for: GNB Absolyte Valve Regulated Lead Acid (VRLA) 1600 Ah 100G33 Battery Rack Assembly in accordance with the requirements specified 24590-WTP-3PS-G000-T0015 (Rev 2) and Environmental Qualification Plan 550001.001-35.0.1 (Rev. 3). The equipment qualification basis represents the most conservative capability of the equipment. The analysis performed for the qualification is not less conservative than the bounding environmental conditions detailed in contract documents issued to Greenberry in contract 24509-QL-POA-EDB0-00001 Rev.0. The qualified life of 10 years has been established based upon an end-condition objective of the equipment condition indicators that correlate to the ability of equipment to perform its safety function. The VRLA Battery Cell Assembly was aged by 10 years (minimum) in accordance with conditions specified by Bechtel Equipment Qualification Datasheet 24590-LAW-EUQ-UPE 00003 Rev. 3 and the process conditions specified by the Instrument Data Sheet 24590-LAW EUD-UPE-00009 Rev. 2. Greenberry Industrial has contracted with GNB Industrial Battery Co located at 4115 S Zero St, Fort Smith, AR 72908 to perform age conditioning, monitoring, and capacity testing in accordance with Environmental Qualification Plan 550001.001-35.0.1 Rev. 1. The required process at the stated conditions set by the parameters established by the plan were completed satisfactorily. The details of the of the test process observed by Greenberry is detailed in the attached Seismic Test Log 550001.001-7.0.3, including examples of the objective evidence collected during the qualification process.

54 ENVIRONMENTAL SCIENCES↗

4D insights into lithium-ion battery sidewall rupture during thermal runaway

Thermal runaway (TR), characterized by rapid exothermic reactions, presents a serious safety risk in lithium-ion batteries (LiBs). External triggers such as high temperatures, mechanical abuse, or internal short circuits (ISCs) can initiate TR, often resulting in sidewall rupture, which may escalate to catastrophic battery pack failure. In this study, we developed and applied high-speed synchrotron imaging techniques to investigate sidewall rupture mechanisms in LiBs subjected to different triggering scenarios. Using in situ 4D tomographic imaging, we visualized the dynamic evolution of sidewall rupture with high spatial and temporal resolution. The results revealed distinct failure behaviors linked to each trigger, underscoring the complex and condition-specific nature of sidewall breach and battery failure. These insights highlight the critical importance of implementing tailored safety strategies across diverse applications. Our findings demonstrate the powerful potential of synchrotron high-speed tomography as a diagnostic tool for advanced safety testing and cell qualification.