Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Bandwidth”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Fundamental bandwidth limits and shaping of frequency-modulated combs

Frequency-modulated (FM) combs based on active cavities like quantum cascade lasers have recently emerged as promising light sources in many spectral regions. Unlike passive modelocking, which generates amplitude modulation using the field’s amplitude, FM comb formation relies on the generation of phase modulation from the field’s phase. They can therefore be regarded as a phase-domain version of passive modelocking. However, while the ultimate scaling laws of passive modelocking have long been known—Haus showed in 1975 that pulses modelocked by a fast saturable absorber have a bandwidth proportional to effective gain bandwidth—the limits of FM combs have been much less clear. Here, we show that FM combs based on fast gain media are governed by the same fundamental limits, producing combs whose bandwidths are linear in the effective gain bandwidth. Not only do we show theoretically that the diffusive effect of gain curvature limits comb bandwidth, but we also show experimentally how this limit can be increased. By adding carefully designed resonant-loss structures that are evanescently coupled to the cavity of a terahertz laser, we reduce the curvature and increase the effective gain bandwidth of the laser, demonstrating bandwidth enhancement. Our results can better enable the creation of active chip-scale combs and be applied to a wide array of cavity geometries.

47 OTHER INSTRUMENTATION

Impact of increased smoothing by spectral dispersion bandwidth on stimulated Brillouin scattering in laser driven Hohlraums

Experiments were conducted at the National Ignition Facility (NIF) to investigate the impact of increased smoothing by spectral dispersion (SSD) bandwidth on the production of stimulated Brillouin scattering (SBS) within an indirect-drive inertial confinement fusion (ICF) Hohlraum. This was done in a subscale gold Hohlraum driven by 192 laser beams depositing 1.1 MJ of energy. The laser bandwidth was increased from 45 to 118 GHz (before frequency tripling) on the 30° and 50° cones, where backscatter could be measured using the Full Aperture Backscatter Station (FABS). It was expected that this 2.6-fold increase in bandwidth would suppress SBS generated within the Hohlraum plasma and lower the backscattered SBS energy on the 50° cones by over a factor of four. Experimental results, however, show that this SSD change only reduced the 50° cone SBS during the main capsule drive by -18±31% and -4.5±7.8% over the entire pulse. This is small compared to expected shot-to-shot SBS reproducibility (∼30%), such that the result can be considered within normal performance fluctuations. New 3D parallel paraxial code (pF3D) simulations, accounting for beam refractive intensification reproduce this result, suggesting that closer to 300 GHz of bandwidth would have been required to mitigate SBS to the expected level. Delivering such a high bandwidth is not feasible at NIF when operating at high peak power and would potentially prevent NIF’s ability to use cross-beam energy transfer (CBET) for implosion symmetry tuning.

Physics

Upgrade of DIII-D radial interferometer–polarimeter for large bandwidth, low noise, and toroidal mode number measurements

Near ion-cyclotron frequency (f ci ) fluctuations, such as those originating from Global and Compressional Alfvén Eigenmodes (GAEs/CAEs), are expected to be present in future fusion reactors but are not well understood due to the limited availability of core measurements in present-day tokamaks. The measurement bandwidth of the Radial Interferometer–Polarimeter (RIP) diagnostic has been upgraded from 1 to 5 MHz to detect these fluctuations in DIII-D. RIP adopts the three-wave technique for simultaneous polarimetric and interferometric measurements. Solid-state microwave sources operating at 650 GHz are used as probe beams and provide 5 MHz bandwidth for both polarimetric and interferometric measurements. Bandwidths of related hardware, including mixer amplifier, signal cable, and digital phase demodulator, are increased correspondingly. Measurement noise is minimized by reducing the time delay between reference and probe signals to nanosecond level and employing correlation-based techniques. Using the upgraded diagnostic, CAE/GAE-like bursting fluctuations are observed in neutral-beam heated plasmas with toroidal magnetic field B φ ≈ 1 T. Current upgrades being undertaken would enable the evaluation of toroidal mode number for these modes. Furthermore, this work opens the possibility of better understanding near ion-cyclotron frequency fluctuations in fusion relevant plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Thermal stress-induced depolarization compensation in wide-bandwidth, high-energy, high-repetition-rate multi-slab laser amplifiers

We present an innovative design for a two-head, gas-cooled multi-slab high-energy, high-repetition-rate amplifier aimed at mitigating thermally induced depolarization in a wide-bandwidth neodymium-doped glass gain medium. This architecture employs two quartz rotators (QRs) with opposite-handedness, strategically positioned within each multi-slab amplifier head, to enhance depolarization compensation. Theoretical modeling of this amplifier configuration demonstrates a 20× reduction in depolarization losses for a 70 mm beam operating at the central wavelength, compared to conventional approaches that utilize a single QR positioned between the amplifier heads. In addition, for a wide bandwidth source, the integration of QRs with opposite-handedness yields a 9× improvement in depolarization losses at the spectral extremes compared to the use of two QRs exhibiting the same optical handedness in both amplifier heads.

47 OTHER INSTRUMENTATION

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION

Improved laser-plasma accelerator stability via high-bandwidth longitudinal focal position stabilization of a 100 TW-class laser system

Laser-plasma accelerators (LPAs) offer an attractive alternative to conventional accelerators for the development of compact electron sources and next-generation light sources. Due to orders-of-magnitude larger accelerating gradients, LPAs enable the acceleration of high-brightness electron beams to ultrarelativistic energies in millimeter- to centimeter-scale distances. However, LPA stability is limited by shot-to-shot fluctuations of the driving laser system. Specifically, fluctuations in the final-focus longitudinal position result in correlated instability in LPA electron beam qualities, including total beam charge, average beam energy, and energy spread. We demonstrate active stabilization of the longitudinal focal position for a 100 TW-class laser system. This repetition-rate scalable stabilization system leverages noninvasive wave front monitoring of a copropagating, unamplified kHz pulse train to guide corrective adjustments to the focal position of a 1 Hz amplified drive laser via an upstream telescope on millisecond timescales. In this demonstration, the approach limits standard deviation fluctuations of the amplified drive beam’s longitudinal focal position to ±0.22⁢ mm (representing at least a 53% reduction), achieved with a correction bandwidth that reaches the Nyquist frequency limit. Consequently, we observe marked improvements in both long-term and shot-to-shot LPA stability in terms of charge and spectrum.

Beam control

Radar transmit bandwidth augmentation

Various technologies pertaining to forming a very high instantaneous bandwidth (IBW) radar signal based upon several radio frequency (RF) signals that have sub-bands of the frequency band of the radar signal are described herein. A radar system is configured to address local oscillator leakage across multiple transmit channels of the radar system, such that the radar signal has a relatively constant or other desired amplitude and phase across frequencies of the radar signal. In addition, the radar system is configured to compute a correction signal that pre-distorts each of the sub-frequency channels such that upon combining enables the generation of desired amplitude and phase response across a transmitted pulse.

Loui, Hung

A novel high frequency, high bandwidth, three phase Mach–Zehnder optical data link

In inertial confinement fusion, hydrogen isotopes are fused together under high pressures and temperatures. Typically, the duration of these experiments is incredibly short, on the order of around 60–150 ps. Due to the high radiation environment, a detector’s signal is typically data linked far distances to a protected location. The diagnostic challenge for fusion reaction history measurements is to measure signals of interest maximizing dynamic range while also maintaining time resolution on the order of 10 ps. In this work, we present a new experimental optical data link used to efficiently transport diagnostic signals over great distances to the recording system while not restricting the dynamic range. The concept of a three phase Mach–Zehnder modulator system is introduced as well as a description of the physical prototype. The initial results from testing at the OMEGA facility show that this system is a viable method for signal transportation.

47 OTHER INSTRUMENTATION

Development of a wide bandwidth heterodyne dispersion interferometer for electron density measurement of atmospheric pressure plasmas

One of the challenges of electron density measurements of an atmospheric pressure plasma (APP) with a laser interferometer is the significant and unwanted phase shift caused by changes in the neutral gas density. These unwanted phase shifts can be mitigated and plasma density measured using an interferometer architecture called a dispersion interferometer (DI). A DI is composed of two nonlinear orientation patterned GaAs crystals for frequency doubling and measures the phase shift induced by a plasma in the interference signal between two second-harmonic beams. Measurement of plasma dynamics or a short plasma pulse in less than a millisecond is enabled with heterodyne detection in a DI using an acousto-optic cell with a frequency of 40 MHz. This heterodyne DI (HDI) is targeted to measure APPs in an electron density range of 10 20 –10 24 m −3 . Finally, the HDI achieves a line-integrated density resolution of 2 × 10 15 m −2 (a phase resolution of 0.005°) with a time constant of 1 μs using ensemble averaging techniques.

atmospheric pressure plasma

Real-time confinement regime detection in fusion plasmas with convolutional neural networks and high-bandwidth edge fluctuation measurements

Abstract A real-time detection of the plasma confinement regime can enable new advanced plasma control capabilities for both the access to and sustainment of enhanced confinement regimes in fusion devices. For example, a real-time indication of the confinement regime can facilitate transition to the high-performing wide-pedestal (WP) quiescent H-mode, or avoid unwanted transitions to lower confinement regimes that may induce plasma termination. To demonstrate real-time confinement regime detection, we use the 2D beam emission spectroscopy (BES) diagnostic system to capture localized density fluctuations of long wavelength turbulent modes in the edge region at a 1 MHz sampling rate. BES data from 330 discharges in either L-mode, H-mode, quiescent H (QH)-mode, or WP QH-mode were collected from the DIII-D tokamak and curated to develop a high-quality database to train a deep-learning classification model for real-time confinement detection. We utilize the 6×8 spatial configuration with a time window of 1024 µ s and recast the input to obtain spectral-like features via fast Fourier transform preprocessing. We employ a shallow 3D convolutional neural network for the multivariate time-series classification task and utilize a softmax in the final dense layer to retrieve a probability distribution over the different confinement regimes. Our model classifies the global confinement state on 44 unseen test discharges with an average F 1 score of 0.94, using only ∼1 ms snippets of BES data at a time. This activity demonstrates the feasibility for real-time data analysis of fluctuation diagnostics in future devices such as ITER, where the need for reliable and advanced plasma control is urgent.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

High-bandwidth Dynamic Load Emulation of Mechanical Systems using Electric Drives

Machine drives are versatile systems that can be programmed to emulate a variety of mechanical loads. In this paper, we walk through the modeling and control framework of a shaft-coupled dual-motor drive system that is programmed to emulate a fictitious mechanical system. We quantitatively evaluate the control performance of such a system and derive a theoretical limit that explains its inaccuracy at high operating frequencies. To overcome this problem, we propose an alternate control structure that achieves the same control objective at high frequencies as well. After suitable adjustments are made to the controller, we validate its performance using simulation results.

machine drives ,load emulation, speed-torque chara

A Miniaturized, High-Bandwidth Optical Fiber Fabry–Perot Cavity Vibration Sensor Demonstrated up to 800 °C

A typical structural health monitoring technique involves measuring the vibrational characteristics of components or systems to detect signs of degradation or damage. Many industrial applications require engineered systems to safely operate under extreme, high-temperature environments that pose challenges not only to materials but also to sensors that would be used for structural health monitoring. Here, in this study, miniaturized optical Fabry-Perot cavities (FPCs) were developed and tested as a means of measuring the resonant frequencies of metal components that are most relevant to extreme-environment applications. Two of the three candidate FPC designs tested up to 800 ° C provided accurate measurements (validated by theoretical models and laser Doppler vibrometry) of the fundamental vibrational mode of the specimen to which each was bonded, although both sensors failed during thermal cycling. An analysis of the reflected optical spectrum from the FPC and X-ray computed tomography revealed two opportunities to improve the sensor reliability. First, the Cu optical fiber coating that was used could either be replaced with a more oxidation-resistant material or protected with commercially available films. Second, the adhesives used to bond the fibers to metal capillaries and establish the FPC could be replaced with a more robust solution, although the Resbond 907TS adhesive appeared to outperform Resbond 907.

Birri, Anthony [Oak Ridge National Laboratory (ORN

Ultra-high Bandwidth, Ultra-high Dynamic Range X-Ray Shock Characterization via Photonic Integrated Circuit

Nuclear weapon component assessment tests at the Z Machine rely on accurate X-ray yield measurements for model validation, design and analysis of component survivability, and source optimization. Yield measurement devices currently used do not provide the requisite certainty to enable accurate and efficient data analysis of test results, which leads to an increase in Z-shots required for evaluation, longer device development times, and higher operation costs. Additionally, current X-ray flux detectors lack high temporal resolution at the tails. Similarly, shock measurement techniques used for component assessment often lack the ability to spatially resolve wave behavior thereby limiting the ability to measure shock propagation dynamics needed to design the next generation of ND components. Here we present the development of a photonic micro-calorimeter and shock sensor consisting of meter-long waveguide spirals that are optomechanically coupled to X-ray absorbing layers to characterize yield and shock propagation at nanosecond timescales.

42 ENGINEERING

Maximizing the Radar Generalized Image Quality Equation for Bistatic SAR Using Waveform Frequency Agility

The radar generalized image quality equation (RGIQE) is a metric used to measure both monostatic and bistatic synthetic aperture radar (BSAR) image quality, it is a function of signal-to-noise ratio (SNR) and 2-D bandwidth. The 2-D bandwidth is equal to the area of the transfer function’s (TF) passband region. With the exception of side-looking monostatic geometries, almost all monostatic and bistatic geometries have skewed passband shapes when waveform frequency parameters remain unchanged from pulse to pulse. Most synthetic aperture radar (SAR) applications require a rectangular-shaped passband region, this is achieved by inscribing a rectangular region within the skewed intrinsic passband region. Increasing skewness results in less inscription area reducing 2-D bandwidth, image SNR, and thus RGIQE capacity. In this article, a waveform with frequency agility is used to rectify the skewness that degrades RGIQE capacity. By changing the waveform’s center frequency and instantaneous bandwidth from pulse to pulse in a particular manner, the intrinsic passband region can be de-skewed. The de-skewed shape maximizes the inscription area thus maximizing 2-D bandwidth, image SNR, and RGIQE capacity. Here, three examples are given in this article, one monostatic geometry, and two bistatic geometries. RGIQE capacity is increased by 52.02%, 44.42%, and 79.09% for the three examples.

47 OTHER INSTRUMENTATION

In-situ relative calibration of Bragg crystals with Monte Carlo line ratio analysis

X-ray line emission spectra can thoroughly characterize hot plasmas, especially when line shapes and ratios convey distinct aspects of plasma conditions. However, the high spectral resolution required for observing line shapes is often at odds with the large bandwidth required to observe many line ratios across a wide spectral range. One strategy to obtain high spectral resolution over a wide bandwidth is to use multiple crystals with calibrated reflectivity so that line intensities across different crystals can be compared. Here, we explore the use of a low-resolution, wide-bandwidth mica survey spectrometer to infer relative reflectivity of two high-resolution, narrow-bandwidth quartz crystals. Finally, a Monte Carlo error analysis determines comparable x-ray line ratios measured from both spectrometers, resulting in an in situ calibration factor and associated uncertainty for the relative reflectivity of the high-resolution crystals.

47 OTHER INSTRUMENTATION

A future of inertial confinement fusion without laser-plasma instabilities

From the beginning of inertial confinement fusion (ICF) research, laser-plasma instabilities excited by narrowband lasers have limited the hydrodynamic design space of all laser-based approaches to inertial fusion energy (IFE). With advances in broadband laser technologies, the next generation of ICF drivers will likely have large bandwidth that is engineered to mitigate laser-plasma instabilities, thereby expanding the hydrodynamic design space to include both robust high yields (>200−MJ) with large-energy laser systems (>4 MJ) and high gains (>10) with moderate-energy laser facilities (<2 MJ). State-of-the-art simulations indicate that laser bandwidths of a few percent are required to mitigate instabilities for IFE-relevant conditions. To test these models and demonstrate that high-bandwidth lasers mitigate laser-plasma instabilities, the Fourth-generation Laser for Ultrabroadband eXperiments will be used with the OMEGA Laser System. The goal is to provide the community with the confidence to invest in a multiple-beam high-bandwidth laser facility that will demonstrate the necessary ablation pressures for robust direct-drive ignition without detrimental levels of hot electrons that degrade the implosion performance. It is important to recognize that the highest performing ICF implosions will likely never be completely LPI free because of the significant advantages to maximizing the laser intensity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

JACC.shared: Leveraging HPC Metaprogramming and Performance Portability for Computations That Use Shared Memory GPUs

In this work, we present JACC.shared, a new feature of Julia for ACCelerators (JACC), which is the performanceportable and metaprogramming model of the just-in-time and LLVM-based Julia language. This new feature allows JACC applications to leverage the high-performance computing (HPC) capabilities of high-bandwidth, on-chip GPU memory. Historically, exploiting high-bandwidth, shared-memory GPUs has not been a priority for high-level programming solutions. JACC.shared covers that gap for the first time, thereby providing a highlevel, portable, and easy-to-use solution for programmers to exploit this memory and supporting all current major accelerator architectures. Well-known HPC and AI workloads, such as multi/hyperspectral imaging and AI convolutions, have been used to evaluate JACC.shared on two exascale GPU architectures hosted by some of the most powerful US Department of Energy supercomputers: Perlmutter (NVIDIA A100) and Frontier (AMD MI250X). The performance evaluation reports speedup of up to 3.5× by adding only one line of code to the base codes, thus providing important accelerators in a simple, portable, and transparent way and elevating the programming productivity and performance-portability capabilities for Julia/JACC HPC, AI, and scientific applications.

Valero Lara, Pedro [ORNL] (ORCID:0000000214794310)

NDVI and Multispectral Images, UAS Flights, Council Road Site, Seward Peninsula, Alaska, June 2022

The dataset contains Normalized Difference Vegetation Index (NDVI) and multispectral images collected on June 18, 2022 using an UAS (Unmanned Aerial System) Yuneec H520, Mapir Survey 3, and Parrot Sequoia cameras. This data was created to accompany the following datasets:- NGEE Arctic CO2, CH4 and Energy Eddy-Covariance (EC) Flux Tower Auxiliary Measurements, Council Road Mile Marker 71, Seward Peninsula, Alaska (https://doi.org/10.5440/1526749)- Sun-induced chlorophyll fluorescence/eddy covariance measurements at NGEE Arctic Council site, Seward Peninsula, Alaska, 2022 (https://doi.org/10.15485/2466175)- NGEE Arctic Meteorological Data from Instrumented PCDC Stations, Council Site, Seward Peninsula, Alaska, 2018 - 2023 (https://doi.org/10.5440/1529604)Survey 3 is RGN (Red, Greeen, Near Infra Red) camera with 87° Horizontal Field of View (HFOV) (19mm) f/2.8 Aperture, 550nm/660nm/850nm (Red+Green+NIR) filter transmission and produced geo referenced jpg and raw format images. Parrot Sequoia is a camera with 16 megapixel RGB (Red, Green, Blue) sensor and 1.2 megapixel monochrome sensors in discrete spectral bands: Green (550nm - 40Nm Bandwidth), Red (660nm - 40nm Bandwidth), Red Edge (735nm - 10nm Bandwidth) and Near Infrared (790nm - 40nm Bandwidth).The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES