Engineering PapersSearch

SEARCH · Engineering Papers

Results for “BUFFER STORAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Low-cost buffer storage for solar industrial steam applications

Motivation and importance: Many industrial process heat consumers operate throughout the day, and deep decarbonization with solar energy requires thermal energy storage. Thermal energy storage provides an additional operational benefit of firm delivery of steam – essential to reducing the risk of costly production interruptions. The group of process heat consumers that use steam for biofuels production for the California transportation fuels market is incentivized through the Low Carbon Fuel Standard (LCFS) to reduce their carbon intensity through the use of solar steam. Examples include ethanol and dimethyl ether production. The production of these and other fuels involves distillation driven by steam reboilers with steam pressures in the range 100-280 psig. These pressures can be delivered from the type of thermal energy storage that has been the focus of this project – a steam accumulator Sunvapor, Inc. (SVI) calls a “Bullet Steam Accumulator” or “BSA TM ”. Our project adds to the understanding of the design and integration of steam accumulators charged by solar thermal energy in a biofuels production facility, and similar facilities that consume process steam. The fuel application requires a demanding level of Process Safety Management not found in other steam applications. The type of steam accumulator SVI engineered and built integrates steam generation and storage in one vessel to reduce cost. Achieving a first of a kind permit to operate such a first device has also added to the understanding of the industrial application of such systems. Goals: The overall goal of the project has been to demonstrate the advantages that a “Bullet Steam Accumulator” (BSA™) can provide to solar steam integration with a manufacturing process. The industrial host has already been convinced of the potential of the available solar steam to lower than carbon intensity score. They have been interviewed for a number of publications such as that tout the advantages SVI’s system brings to their operations. Accomplishments: At the end of 2023 Sunvapor placed in service the country’s first industrial solar boiler with thermal energy storage. At the same time, this placement in service represents the first pilot commercial system to decarbonize biofuels production through the use of solar thermal energy. While the full technical effectiveness will be shown as soon as the customer’s plant is able to consume the available steam, the economic feasibility was indicated early in the project when the combination of costs and steam pricing required to meet investor expectations was determined. The project represents a reference pilot from which a full-scale commercial system may be expanded. This pilot is a necessary first step in providing the full potential benefits to the public, including decarbonization of transportation fuels. The decarbonization of the separation steps in fuels production may be the most cost-effective and nearest term solar fuel. Co-benefits include a reduction of air pollutants such as NOx and particulate matter, and job creation for the construction, operation and maintenance of industrial solar facilities.

14 SOLAR ENERGY

LBNF/DUNE Liquid Argon Roadmap

The Deep Underground Neutrino Experiment (DUNE) is an international flagship venture to unlock the mysteries of neutrinos. Hosted at the Sanford Underground Research Facility (SURF) and supported by the Long-Baseline Neutrino Facility (LBNF), DUNE relies on nearly 75,000 tonnes of ultrapure liquid argon (LAr) housed in state-of-the-art cryostats. Transporting such vast quantities of LAr to its destination a mile underground in Lead, SD, is a logistical and engineering challenge. The process begins with securing large quantities of liquid argon from suppliers located far from the site, with major sources situated near Houston, TX and Chicago, IL. The receiving facility, located atop a mountain with steep, often snow-covered access roads, provides limited maneuverability for trucks and can only handle two deliveries simultaneously. The facility serves as an entry point for argon to the greater LBNF cryogenic system. It is furnished with truck unloading stations, limited buffer storage of some 280 tonnes capacity, and vaporizers. The last are crucial for converting liquid argon into gas for transfer down the Ross Shaft, eliminating the need for cryogens in the vertical pipeline. These constraints, along with other operational factors, cap the delivery rate at 70 tonnes per day. Once underground, the argon is purified and recondensed before filling the cryostats. This roadmap outlines the integrated supply chain and cryogenic systems that enable the delivery of LAr to support DUNE’s groundbreaking physics research.

Maciazka, Matt [Fermilab]

A buffering heat exchanger/thermal energy storage system for desalination applications

A buffering heat exchanger/thermal energy storage (BHXTES) system was designed using a fast-response phase-change material/graphite foam (PCM/GF) medium for desalination and potentially other industrial applications. Unlike a store-now-and-use-later TES system, this study focused on developing a dynamically balanced, continuously used, system that optimized three functions. A lab-scale prototype was designed and fabricated with a PureTemp 151/GF storage medium. The experimental data showed excellent thermal performance repeatability indicating minimal effects of PCM expansion and contraction on the GF as well as negligible PCM redistribution effects. The experimental data also served as a validation of the numerical model of the BHXTES system, after which optimization of the BHXTES system was conducted through numerical simulations for both PureTemp 151/GF and solar salt/GF as the storage medium. The results show that, with a Therminol 55 heat transfer fluid, continuous operation of the system can be realized with a solar energy source through cycles of 8-h changing for desalination and energy storage with the supplied heat followed by 16-h discharging for desalination with the stored energy. As a result, the working fluid outlet temperatures are generally in the ranges of approximately 128–160 °C for a PureTemp 151/GF medium and 198–220 °C for a solar salt/GF medium.

Buffering

Design-Point Techno-Economics of Brayton Cycle PTES for Combined Heat and Power

Pumped thermal energy storage (PTES) systems are grid batteries that use heat pumps to create both hot and cold thermal energy stores when there is excess electricity and then use a power cycle to convert the thermal energy into electricity when there is demand for electricity. In normal operation, Joule–Brayton PTES discharges low-grade heat at temperatures useful for thermal energy consumers like district and industrial heating. Furthermore, PTES designs, like conventional combined heat and power (CHP) technology, can be modified to sacrifice some round-trip efficiency (RTE) to increase the temperature of heat rejection. Here, this paper uses design-point performance and cost models that provide a detailed understanding of the efficiency and cost tradeoffs of rejecting heat at various temperatures in ideal-gas Brayton PTES configurations. First, we keep the heat rejection in its nominal location in the PTES system: in the discharge cycle after the low-pressure exit of the recuperator before the cold-storage heat exchanger. Next, we move the heat rejection to the discharge turbine exit. We define design-point metrics that isolate both the cost and performance penalty associated with the hotter heat rejection and attribute it exclusively to the heat economic metrics. Finally, we estimate the performance of electric heater technology to generate heat at equivalent temperatures. We find that the levelized cost of heat (LCOH), including the cost of thermal energy storage (TES) buffering the PTES and heat off-taker, compares favorably versus electric technologies and is less than the cost of natural gas for low temperature scenarios and competitive with the cost of natural gas in some regions of the contiguous U.S. in high temperature scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION

Electrifying Airport GSE: Monte Carlo Grid Impacts

Airports globally are shifting from ICE-powered to electric Ground Support Equipment (eGSE) to enhance efficiency, reduce operational costs, and improve operator health. Leveraging predictable routes, flat terrain, and low operational speeds, airports provide ideal conditions for electrification. This study evaluates freight GSE electrification at Dallas-Fort Worth International Airport (DFW), USA, using the Agile@ platform, which integrates three analytical methods: Freight Facility Model (FFM), Activity-Structure-Intensity-Fuel (ASIF), and Monte Carlo simulations. Results from 10,000 simulations indicate modest but critical increases in electricity demand and significant variability in GSE energy consumption. These insights emphasize the importance of data-driven scheduling, targeted maintenance, and strategic infrastructure planning. For high-uncertainty scenarios, airports are advised to deploy buffer energy storage systems (battery banks), implement demand-response charging strategies, schedule flexible workforce shifts, and prioritize proactive maintenance-particularly for equipment with higher operational uncertainty, such as tug tractors with trailers. Agile@ thus offers a robust, scalable, and data-driven framework to optimize long-term GSE planning and enhance reliability across diverse airport environments.

Bose, Ranjan [ORNL] (ORCID:0009000791026327)

Design-Point Techno-Economics of Brayton Cycle PTES for Combined Heat and Power

Pumped thermal energy storage (PTES) systems are grid batteries that use heat pumps to create both hot and cold thermal energy stores when there is excess electricity and then use a power cycle to convert the thermal energy into electricity when there is demand for electricity. In normal operation, Joule-Brayton PTES discharges low-grade heat at temperatures useful for thermal energy consumers like district and industrial heating. Furthermore, PTES designs, like conventional combined heat and power (CHP) technology, can be modified to sacrifice some round-trip efficiency RTE to increase the temperature of heat rejection. This paper uses design-point performance and cost models that provide a detailed understanding of the efficiency and cost trade-offs of rejecting heat at various temperatures in ideal-gas Brayton PTES configurations. First, we keep the heat rejection in its nominal location in the PTES system: in the discharge cycle after the low-pressure exit of the recuperator before the cold-storage heat exchanger. Next, we move the heat rejection to the discharge turbine exit. We define design-point metrics that isolate both the cost and performance penalty associated with the hotter heat rejection and attribute it exclusively to the heat economic metrics. Finally, we estimate the performance of electric heater technology to generate heat at equivalent temperatures. We find that the levelized cost of heat, including the cost of thermal energy storage (TES) buffering the PTES and heat off-taker, compares favorable versus electric technologies and is less than the cost of natural gas for low temperature scenarios and competitive with the cost of natural gas in some regions of the contiguous United States in high temperature scenarios.

CHP

HDF5 in the exascale era: Delivering efficient and scalable parallel I/O for exascale applications

Accurately modeling real-world systems requires scientific applications at exascale to generate massive amounts of data and manage data storage efficiently. However, parallel input and output (I/O) faces challenges due to new application workflows and the state-of-the-art memory, interconnect, and storage architectures considered in exascale designs. The storage hierarchy has expanded with node-local persistent memory, solid-state storage, and traditional disk and tape-based storage, thus requiring efficiency at each layer and much more efficient data movement among these layers. This paper discusses how the ExaHDF5 project improved the I/O performance and data management for exascale architectures by enhancing HDF5, a widely used parallel I/O library. The team developed an Asynchronous I/O Virtual Object Layer (VOL) connector that allowed overlapping I/O with computation. They also created a Cache VOL to complement asynchronous I/O by incorporating fast storage layers, such as burst buffer and node-local storage, into the parallel I/O workflow through caching and staging data. Additionally, the team enabled data aggregation and I/O at the node level by using a Subfiling Virtual File Driver (VFD). To demonstrate superior I/O performance with HDF5 at exascale, the ExaHDF5 team collaborated with several exascale applications. In this paper, we show I/O performance improvements for three applications: Cabana (a particle-based simulation library), EQSIM (a regional earthquake simulation software), and E3SM (a climate system modeling library).

Asynchronous I/Ol

Exploring DAOS as a Burst Buffer for a 100 Gbps DAQ Real-Time Streaming System

We present an experimental evaluation of a burst buffer for a real-time DAQ streaming system designed to transmit instrument data to remote data centers. The system is based on EJ-FAT, a load balancing system capable of Nx 100Gbps streams, distributing data from event sources to processing nodes. We explore applying the DAOS system as a burst buffer to serve a number of purposes: improve resiliency, elasticity and add new functions into the processing pipeline. In the evaluation a sender transmits events over a 100Gbps network to a receiver integrated with DAOS to store the reassembled events using DAOS APIs. We evaluate the system for possible bottlenecks and provide end-to-end evaluation with a burst buffer using DAOS storage abstractions. We show that a receiver node can support 38.1 Gbps. This proves the viability of our approach and allows us to extend this work to investigate scale-out properties and new streaming optimizations.

Mei, Xinxin

Divergent trait controls on soluble sugars and starch underlie global strategies of tree carbohydrate storage

Nonstructural carbohydrate (NSC) stores buffer tree metabolism, osmotic regulation, and defense, thereby mediating tolerance and survival under climate extremes. Yet, the functional and evolutionary determinants of interspecific variation in NSC remain elusive, limiting understanding and prediction of forest carbon allocation and mortality under global change. Here, we present a cross-species synthesis of NSC concentrations across multiple organs for 281 woody species from 102 mixed forest communities worldwide, where we quantified species-specific deviations from community means to disentangle intrinsic trait effects from environmental and methodological variation. We found phylogenetic signals in NSC deviations, with coniferous gymnosperms and evergreen species consistently maintaining lower stem soluble sugars and starch concentrations than co-occurring angiosperms and deciduous species, respectively. A global pattern emerged where greater stomatal sensitivity to leaf water potential was associated with declines in the relative concentrations of both sugars and starch. In contrast, xylem hydraulic safety traits showed weak and organ-dependent relationships with NSC concentrations. Sugars increased with photosynthetic capacity and declined with wood density, whereas starch showed the reverse pattern, which aligned with the distinct functional-metabolic roles of sugars and starch. By integrating trait-based ecology with a community-centered framework, our study provides global evidence that stomatal regulation, photosynthetic capacity, specific leaf area, and wood density jointly govern interspecific NSC variation, through contrasting effects on sugars and starch. These are among the most broadly measured traits globally, thus the emergent carbohydrate–trait relationships can have broad applications toward understanding and predicting forest growth and survival under climate change.

tropic system

Enhancing SWAT with mechanistic plant hydraulics: development and application in the Hanjiang River Basin

Plant transpiration plays a critical role in global water and energy cycles, requiring better process understanding as climate change intensifies drought stress and alters plant responses. Most hydrological models such as the widely-used SWAT lack representation of plant hydraulics, the mechanistic processes controlling plant water regulation and transpiration. Here, this study developed SWAT-PHS by integrating a plant hydraulics scheme (PHS) into SWAT hydrological model, enabling explicit simulation of root water uptake, sap flow, storage and transpiration at 30-minute timescales for watershed-scale modeling. In the Hanjiang River Basin, SWAT-PHS mitigated overestimation of runoff during the rainy season and underestimation during the dry season, reducing the overall simulation error by 29% across the entire simulation period. The model can simulate reasonable plant water dynamics, including diurnal transpiration patterns and drought responses showing declining transpiration flux, hydraulic buffering through stem water storage, and depth-dependent root water uptake strategies. Sensitivity analysis shows that SWAT-PHS captured mechanistic relationships between plant hydraulic traits and transpiration, with root distribution and stem capacitance positively affecting annual transpiration while vulnerability parameters showed negative effects. This work provides a pathway for improving hydrologic modeling and water resource management by better representing plant water regulation under climate change and expected intensifying water stress conditions.

China

Resource Adequacy and Capital Cost Considerations Pertaining to Large Electric Grids Powered by Wind, Solar, Storage, Gas, and Nuclear

The capacity and generation of wind, solar, storage, nuclear, and gas are estimated for large, idealized copper-plate electric grids. Wind and solar penetrations of 30% to 80% are considered together with different storage systems such as vanadium and lithium-ion batteries, pumped hydroelectric, compressed air, and hydrogen. In addition to a baseline dispatchable fleet without wind/solar, two bounding cases with wind/solar are analyzed: one without storage and one where the whole wind/solar fleet is connected to the storage system, hence providing a buffer between the wind/solar fleet and the grid. The reality will likely be somewhere between these bounding cases. The viability of a power grid with a large wind/solar penetration and no storage is not guaranteed but was nonetheless considered to provide a lower-bound capital cost estimate. Overall, the options that rely strongly on wind, solar, and storage could be significantly more capital-intensive than those that rely strongly on nuclear, depending on the amount of storage necessary to ensure grid stability. This is especially true in the long run because wind, solar, and storage assets have shorter lifetimes than nuclear plants and, consequently, need to be replaced more frequently. More analyses (e.g., grid stability and public acceptance) are necessary to determine which option is most likely to provide the path of least resistance to powering a clean, affordable, and reliable grid in a timely manner. Depending on the priorities, the path of least resistance may not necessarily be the one that is less capital intensive.

adequacy

Case Study: Seattle Waterfront Networked Microgrid Evaluation - Case Study for Port Electrification Handbook

Many ports and waterfronts are evaluating alternative electrification efforts, including electrification of passenger and vehicle ferries. In Seattle, the Washington State Department of Transportation, in conjunction with Seattle City Light (the local utility) and the Port of Seattle, are working to deploy a hybrid electric ferry and provide charging at Seattle’s Colman dock. As part of this ferry electrification effort, Seattle City Light is considering including a large battery energy storage system (BESS) to help “buffer” the ferry charging. The “buffer” provides energy arbitrage and spreads out the large amount of power needed to recharge the ferry to times when the ferry is out of the dock – rather than one very large peak for 15 minutes, the battery storage allows it to be a smaller power value over a longer duration. This initial BESS concept served as the jumping off point to explore an expanded microgrid concept via a notional test system that incorporates additional distributed energy resources (DER) and infrastructure upgrades to the local distribution infrastructure at the Seattle Waterfront and neighboring Port of Seattle properties. This case study examined the potential for secondary use of the BESS within a networked microgrid during the scenario of a large-scale power outage, such as a natural disaster.

24 POWER TRANSMISSION AND DISTRIBUTION

Quantifying the Potential Atmospheric Leakage Risks Associated With the Geologic Storage of CO 2 in Saline Aquifers for Use in Voluntary Carbon Market Buffer Account Determination

Conference paper presented at 17th International Conference on Greenhouse Gas Control Technologies (GHGT-17), Calgary, Alberta, Canada, October 20–24, 2024. This paper presents the results of a detailed study into the potential atmospheric leakage risks associated with the geologic storage of CO 2 in saline aquifers. This study included a detailed literature review, a re-creation of existing CO 2 leakage models put forth by other authors and, lastly, the development of an enhanced model that can be utilized for assessing the potential losses to the atmosphere of stored CO 2 across a variety of potential project parameters. The results of this study indicate that, across broad ranges of input parameters for mechanisms that have the potential for CO 2 loss from the storage complex to the atmosphere, there is an extremely low risk of CO 2 leakage to the atmosphere, with the median leakage risk estimated to be 0.1% of total injected CO 2 . The risk of leakage from real-world storage projects is likely to be even lower than those estimated through this study.

01 COAL, LIGNITE, AND PEAT

Integrated geological, economic, and risk assessment of underground hydrogen storage

Underground hydrogen storage (UHS) is a promising option to buffer variable renewable power and support the hydrogen economy. Yet this technology is early-stage, and key uncertainties remain about how coupled processes such as geochemical and geomechanical impacts affect long-term storage security. In this paper, we seek to integrate the results from a large, multi-scale research program to quantify core feasibility metrics and situate these studies within ongoing efforts. Through this work, we evaluate hydrogen recoverability during storage by assessing diffusive losses, losses to geochemical interactions and their subsequent impact on geomechanical properties, and losses to residual saturation during injection and withdrawal. Molecular and laboratory studies show that lithologic heterogeneity, pore geometry, and mineral surface chemistry govern hydrogen–rock interactions, controlling loss pathways. High-pressure coreflooding is used to estimate relative permeabilities and measure parameters needed for reservoir-scale sensitivity analyses. These core-scale experiments found early hydrogen breakthrough at low saturations driven by capillary and viscous fingering, which limits pore-space utilization at early times, while repeated injection and withdrawal cycles improve deliverability over time. Technoeconomic factors and purity requirements for end uses are also considered as part of our comprehensive feasibility analysis. Finally, we underscore the importance of geophysical monitoring and tailored injection strategies to maintain integrity and efficiency. Together, these results provide a quantitative foundation for safe, scalable deployment of UHS and highlight priorities for future integrated studies.

08 HYDROGEN

The Role of Bedrock Circulation Depth and Porosity in Mountain Streamflow Response to Prolonged Drought

Quantitative understanding is lacking on how the depth of active groundwater circulation in bedrock affects mountain streamflow response to a multi-year drought. We use an integrated hydrological model to explore the sensitivity of a variety of streamflow metrics to bedrock circulation depth and porosity under a plausible extreme drought scenario lasting up to 5 years. Endmember depth versus hydraulic conductivity relationships and porosity values for fractured crystalline rock are simulated. With drought, a deeper circulation system with higher drainable porosity more effectively buffers minimum flow and significantly limits perennial stream loss in comparison to a shallow circulation system. Streamflow buffering is accomplished through extensive groundwater storage loss. However, deeper circulation systems experience prolonged recovery from drought in comparison to storage-limited shallow systems. Research highlights the importance of characterizing the deeper bedrock hydrogeology in mountainous watersheds to better understand and predict drought impacts on stream ecosystem health and water resource sustainability.

54 ENVIRONMENTAL SCIENCES

Numerical Modeling & Size Optimization of Thermal Energy Storage for Iron & Steel Production

Iron and steel production are responsible for 90 million MtCO2 per year in the United States. Hydrogen direct reduction of iron (H2DRI) is a promising pathway for a more sustainable iron production than commercially deployed technologies which rely on natural gas. The H2DRI process requires hydrogen at a temperature of up to 950 degrees C fed into a reduction furnace to produce pellets or briquettes that are used in the downstream iron and steelmaking process. In this work, we propose to use an electrical thermal energy storage (ETES) system, that can use renewable electricity to store high-temperature heat and dispatch it upon demand. Such a system can buffer the H2DRI plant from the variability of electricity prices by charging during curtailment and running the plant from storage during times of peak electricity price. We have developed heat transfer models for two different ETES systems that can be used to heat up hydrogen to the required temperatures: a particle-based ETES and a firebrick ETES. These models are used to evaluate the performance of such a system and support the sizing and preliminary cost estimation. The preliminary results using both models show that designing ETES systems for an industrial-scale H2DRI furnace is feasible. The firebrick ETES system has limited operational duration, which might limit the price buffering effect unless significantly oversized. The particle ETES system heat exchanger has industry-feasible dimensions, but its storage capacity would be decided upon the number of particle storage silos.

25 ENERGY STORAGE

Impacts of Control, Penetration, and Distribution of Embedded Storage Network in Bulk Power System

The current shift in generation mix from fossil fuel plants towards variable and intermittent renewable energy sources is poised to create a future grid with reduced physical inertia and mismatch between generation and demand. Embedded storage, which is a concept of a coordinated network of storage units sited at the interface between the transmission and distribution system, is proposed as a mechanism to provide a buffer between generation and demand. This paper proposes an automated framework to model and integrate embedded storage in large-scale power systems with industry-grade grid-following (GFL) and grid-forming (GFM) control technologies. More importantly, the developed framework is used to explore the impacts of embedded storage control, penetration, location, and capacity in providing fast frequency response to the grid under contingency events such as generator trips and faults. The framework and study are conducted using the transient-stability simulation tool PSS/E and a realistic model of the Puerto Rico grid as a chosen test system. The simulation results show that GFL and GFM embedded storage, distributed throughout the system, with sufficient penetration and capacity, can effectively improve primary frequency response of the system under the studied contingency events.

Battery Energy Storage, embedded storage, grid-for