Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BRu”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Analysis, design, fabrication and testing of the mini-Brayton rotating unit (Mini-BRU). Volume 1: Text and tables

A 500 to 2100 watt power output Mini-Brayton Rotating Unit (Mini-BRU)was analyzed, designed, fabricated and tested. Performance and test data for the various components is included. Components tested include the 2.12 in. diameter compressor, the 2.86 in. diameter turbine, the Rice alternator and the cantilevered foil-type journal and thrust bearings. Also included are results on the fabrication of a C-103 turbine plenum/nozzle assembly and on offgassing of the organic materials in the alternator stator.

Dobler, F. X.↗

Mini-BRU/BIPS 1300 watt (sub)e dynamic power conversion system development: Executive summary

The status of the Brayton Isotope Power System (BIPS) is summarized. A 1200 watt sub e ground development unit was built and tested in a 0.000010 torr vacuum environment. Peformance mapping and 1000 hours of proof of concept system testing were completed. Specific components, primarily turbocompressor/alternator and recuperator performed according to predictions, thus achieving the design goal of 25 percent net power conversion efficiency. The system was fabricated from superalloy (Hastelloy-X and Waspaloy) thus placing it entirely within current state-of-the-art technology. The system could be flyable in the early 1980's pending flight qualification.

Source record↗

Mini-BRU/BIPS foil bearing development

The analysis revealed the failure agent to be a combination of poor teflon coating adhesion, a decrease in bearing sway space and, possibly, lack of flushing flow through the bearing. A change in Teflon coating vendors provided substantially improved coating quality and surface finish. The sway space was increased and the cooling bleed flow was adjusted to flush the bearing. These changes were included in a test conducted in the WHL from 6 April to 22 May 1978 which resulted in the completion of 1006.9 hours of operation at temperature and load. Post-test inspection revealed the bearings to be in excellent condition and capable of completing a much longer test.

Dobler, F. X.↗

The 2kW Mini-BRU Electrical Controls Concept and Transient Performance

The proposed Jupiter Icy Moon Orbiter, JIMO, mission selected a Brayton power conversion system as its electrical power generator. Although the JIMO mission power conversion system was expected to produce in the order of 100 kW, an available 2 kW Brayton system was used to develop control system strategies for the JIMO mission. This report describes the shunt loading voltage/speed regulation control concept developed for the 2 kW system, and the transient performance of controls. The 2 kW alternator is a permanent magnet alternator as proposed for the JIMO mission, and operates at a similar speed and internal impedance, allowing it to be used as an accurate model for performance of the larger system. The JIMO mission was cancelled in September 2005.

Birchenough, Arthur G.↗

Inspection of two Brayton rotating units after extensive endurance testing

A system was designed to produce 2-10 kW net continuous electric power for at least 5 years. The turbine-alternator-compressor power conversion unit in the system is designated Brayton Rotating Unit (BRU). Four BRU's were fabricated and extensively tested. One BRU has accumulated 11,000 hours of operation, and another has accumulated in excess of 21,000 hours. Testing has demonstrated that the BRU's have met or exceeded performance objectives. Two BRU's were disassembled and given a thorough post-test inspection. The inspection results show that after 21,000 hours of operation there is no apparent wear or failure mode that will prevent the attainment of the 5-year life objective.

Dunn, J. H.↗

Impact of resistance exercise during bed rest on skeletal muscle sarcopenia and myosin isoform distribution

Because resistance exercise (REx) and bed-rest unloading (BRU) are associated with opposing adaptations, our purpose was to test the efficacy of REx against the effects of 14 days of BRU on the knee-extensor muscle group. Sixteen healthy men were randomly assigned to no exercise (NoEx; n = 8) or REx (n = 8). REx performed five sets of leg press exercise with 80-85% of one repetition maximum (1 RM) every other day during BRU. Muscle samples were removed from the vastus lateralis muscle by percutaneous needle biopsy. Myofiber distribution was determined immunohistochemically with three monoclonal antibodies against myosin heavy chain (MHC) isoforms (I, IIa, IIx). MHC distribution was further assessed by quantitative gel electrophoresis. Dynamic 1-RM leg press and unilateral maximum voluntary isometric contraction (MVC) were determined. Maximal neural activation (root mean squared electromyogram) and rate of torque development (RTD) were measured during MVC. Reductions (P < 0.05) in type I (15%) and type II (17%) myofiber cross-sectional areas were found in NoEx but not in REx. Electrophoresis revealed no changes in MHC isoform distribution. The percentage of type IIx myofibers decreased (P < 0.05) in REx from 9 to 2% and did not change in NoEx. 1 RM was reduced (P < 0.05) by 9% in NoEx but was unchanged in REx. MVC fell by 15 and 13% in NoEx and REx, respectively. The agonist-to-antagonist root mean squared electromyogram ratio decreased (P < 0.05) 19% in REx. RTD slowed (P < 0.05) by 54% in NoEx only. Results indicate that REx prevented BRU-induced myofiber atrophy and also maintained training-specific strength. Unlike spaceflight, BRU did not induce shifts in myosin phenotype. The reported benefits of REx may prove useful in prescribing exercise for astronauts in microgravity.

NASA Discipline Musculoskeletal↗

Steady-state temperature distribution within a Brayton rotating unit operating in a power conversion system using helium-xenon gas

The Brayton rotating unit (BRU), consisting of a turbine, an alternator, and a compressor, was tested as part of a Brayton cycle power conversion system over a side range of steady state operating conditions. The working fluid in the system was a mixture of helium-xenon gases. Turbine inlet temperature was varied from 1200 to 1600 F, compressor inlet temperature from 60 to 120 F, compressor discharge pressure from 20 to 45 psia, rotative speed from 32 400 to 39 600 rpm, and alternator liquid-coolant flow rate from 0.01 to 0.27 pound per second. Test results indicated that the BRU internal temperatures were highly sensitive to alternator coolant flow below the design value of 0.12 pound per second but much less so at higher values. The armature winding temperature was not influenced significantly by turbine inlet temperature, but was sensitive, up to 20 F per kVA alternator output, to varying alternator output. When only the rotational speed was changed (+ or - 10% of rated value), the BRU internal temperatures varied directly with the speed.

Johnsen, R. L.↗

Gas-injection-start and shutdown characteristics of a 2-kilowatt to 15-kilowatt Brayton power system

Two methods of starting the Brayton power system have been considered: (1) using the alternator as a motor to spin the Brayton rotating unit (BRU), and (2) spinning the BRU by forced gas injection. The first method requires the use of an auxiliary electrical power source. An alternating voltage is applied to the terminals of the alternator to drive it as an induction motor. Only gas-injection starts are discussed in this report. The gas-injection starting method requires high-pressure gas storage and valves to route the gas flow to provide correct BRU rotation. An analog computer simulation was used to size hardware and to determine safe start and shutdown procedures. The simulation was also used to define the range of conditions for successful startups. Experimental data were also obtained under various test conditions. These data verify the validity of the start and shutdown procedures.

Cantoni, D. A.↗

Design and fabrication of gas bearings for Brayton cycle rotating unit

Analysis, design, and testing of two types of pivoted pad journal bearings and a spiral-grooved thrust bearing suitable for direct installation into the NASA 2 to 15 KW Brayton Cycle Rotating Unit (BRU) have been accomplished. Both types of tilting pad bearing assemblies are of the preloaded type, consisting of three pads with one pad flexibly mounted. One type utilizes a non-conforming pivot, while the other replaces the conventional spherical pivot with a cruciform flexible member. The thrust bearing is flexure mounted to accommodate static machine mislinement. Test results indicate that both types of journal bearings should satisfy the requirements imposed by the BRU. Hydrostatic tests of the spiral-grooved thrust bearing showed it to be free of pneumatic hammer with as many as 24 orifices over the BRU pressure and load range.

Frost, A.↗

Effects of vibration and shock on the performance of gas-bearing space-power Brayton cycle turbomachinery. 2: Sinusoidal and random vibration

The vibration response of a gas-bearing rotor-support system was analyzed experimentally documented for sinusoidal and random vibration environments. The NASA Brayton Rotating Unit (BRU), 36,000 rpm; 10 KWe turbogenerator; was subjected in the laboratory to sinusoidal and random vibrations to evaluate the capability of the BRU to (1) survive the vibration levels expected to be encountered during periods of nonoperation and (2) operate satisfactorily (that is, without detrimental bearing surface contacts) at the vibration levels expected during normal BRU operation. Response power spectral density was calculated for specified input random excitation, with particular emphasis upon the dynamic motions of the thrust bearing runner and stator. A three-mass model with nonlinear representation of the engine isolator mounts was used to calculate axial rotor-bearing shock response.

Tessarzik, J. M.↗

Resistance exercise prevents plantar flexor deconditioning during bed rest

Because resistance exercise (REX) and unloading induce opposing neuromuscular adaptations, we tested the efficacy of REX against the effects of 14 d of bed rest unloading (BRU) on the plantar flexor muscle group. Sixteen men were randomly assigned to no exercise (NOE, N = 8) or REX (N = 8). REX performed 5 sets x 6-10 repetitions to failure of constant resistance concentric/eccentric plantar flexion every other day during BRU. One-repetition maximum (1RM) strength was tested on the training device. The angle-specific torque-velocity relationship across 5 velocities (0, 0.52, 1.05, 1.75, and 2.97 rad.s-1) and the full range-of-motion power-velocity relationship were assessed on a dynamometer. Torque-position analyses identified strength changes at shortened, neutral, and stretched muscle lengths. Concentric and eccentric contractile work were measured across ten repetitions at 1.05 rad.s-1. Maximal neural activation was measured by surface electromyography (EMG). 1RM decreased 9% in NOE and improved 11% in REX (P < 0.05). Concentric (0.52 and 1.05 rad.s-1), eccentric (0.52 and 2.97 rad.s-1), and isometric angle-specific torques decreased (P < 0.05) in NOE, averaging 18%, 17%, and 13%, respectively. Power dropped (P < 0.05) in NOE at three eccentric (21%) and two concentric (14%) velocities. REX protected angle-specific torque and average power at all velocities. Concentric and eccentric strength decreased at stretched (16%) and neutral (17%) muscle lengths (P < 0.05) in NOE while REX maintained or improved strength at all joint positions. Concentric (15%) and eccentric (11%) contractile work fell in NOE (P < 0.05) but not in REX. Maximal plantar flexor EMG did not change in either group. In summary, constant resistance concentric/eccentric REX completely prevented plantar flexor performance deconditioning induced by BRU. The reported benefits of REX should prove useful in prescribing exercise for astronauts in microgravity and for patients susceptible to functional decline during bed- or chair-bound hospital stays.

NASA Discipline Musculoskeletal↗

Design and fabrication of the Brayton rotating unit

The Brayton rotating unit (BRU), operating on a gas bearing system, has been designed, fabricated, and demonstrated for use in a closed Brayton cycle space power conversion system. The BRU uses a binary mixture of xenon and helium (molecular weight, 83.8) as the cycle working fluid and bearing lubricating medium and was designed to produce from 2.25 to 10.5 kw sub e of 1200 Hz three-phase electrical power. The single-shaft rotating assembly operates at a design speed of 36,000 rpm and comprises a radial single-stage compressor, a four-pole Rice alternator rotor, and a radial inflow turbine. Four units, a dynamic simulator and three component research packages, were supplied to the NASA Lewis Research Center for performance testing and further development.

Davis, J. E.↗

Thermal effects on the clearance and stiffness of foil journal bearings for a Brayton cycle turboalternator

An analysis of foil journal bearings for a NASA Brayton Cycle Unit (BRU) is presented. The study represents an extension of previous work in that it includes the effects of thermal expansion of foil-bearing components, as well as an improved model of the influence of foil flexure. The results presented give the bearing film thickness, the bearing stiffness, and the foil tension as functions of the operating temperatures and the elasto-hydrodynamic and geometrical parameters pertinent to the design of BRU foil bearings. A computer program for the evaluation of design data and for parametric studies is included.

Eshel, A.↗

Effects of vibration and shock on the performance of gas-bearing space-power Brayton cycle turbomachinery. Part 3: Sinusoidal and random vibration data reduction and evaluation, and random vibration probability analysis

The random vibration response of a gas bearing rotor support system has been experimentally and analytically investigated in the amplitude and frequency domains. The NASA Brayton Rotating Unit (BRU), a 36,000 rpm, 10 KWe turbogenerator had previously been subjected in the laboratory to external random vibrations, and the response data recorded on magnetic tape. This data has now been experimentally analyzed for amplitude distribution and magnetic tape. This data has now been experimentally analyzed for amplitude distribution and frequency content. The results of the power spectral density analysis indicate strong vibration responses for the major rotor-bearing system components at frequencies which correspond closely to their resonant frequencies obtained under periodic vibration testing. The results of amplitude analysis indicate an increasing shift towards non-Gaussian distributions as the input level of external vibrations is raised. Analysis of axial random vibration response of the BRU was performed by using a linear three-mass model. Power spectral densities, the root-mean-square value of the thrust bearing surface contact were calculated for specified input random excitation.

Tessarzik, J. M.↗

Performance of gas-lubricated nonconforming pivoted-pad journal bearings and a flexibly mounted spiral-groove thrust bearing

A test program was conducted to determine the performance characteristics of gas-lubricated nonconforming pivoted-pad journal bearings and a spiral-groove thrust bearing designed for the Brayton cycle rotating unit (BRU). Hydrostatic, hybrid (simultaneously hydrostatic and hydrodynamic), and hydrodynamic tests were conducted in argon gas at ambient pressure and temperature ranges representative of hydrostatic operation up to the 10.5-kWe BRU power-generating level. Performance of the gas lubricated bearings is presented, including hydrostatic gas flow rates, bearing clearances, bearing temperatures, and transient performance.

Ream, L. W.↗

Summary of gas bearing applications in the field of space electric power systems.

The NASA-Lewis Research Center is investigating the technology of closed Brayton cycle electric power systems for space. The turbine-alternator-compressor power conversion unit for such a system is designated Brayton Rotating Unit (BRU). In parallel to power system testing, a BRU improvement effort was initiated. A major portion of this effort involves the testing and evaluation of different bearing systems. A description of each bearing is presented along with results of the evaluation to date and a comparison of the merits and limitations of each bearing.

Dunn, J. H.↗

Performance of gas-lubricated cruciform-mounted tilting-pad journal bearings and a damped flexibly mounted spiral-groove thrust bearing

A test program was conducted to determine the performance characteristics of gas-lubricated cruciform-mounted tilting-pad journal bearings and a damped spiral-groove thrust bearing designed for the Brayton cycle rotating unit (BRU). Hydrostatic, hybrid (simultaneously hydrostatic and hydrodynamic), and hydrodynamic tests were conducted in argon gas at ambient pressure and temperature ranges representative of operation to the 10.5 kWe BRU power-generating level. Performance of the gas lubricated bearings is presented including hydrostatic gas flow rates, bearing clearances, bearing temperatures, and transient performance.

Ream, L. W.↗