Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BRAGG REFLECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Stationary Bragg reflection of laser light in inhomogeneous absorbing plasmas inside inertial confinement fusion Hohlraums

Laser-produced plasma in inertial confinement fusion (ICF) Hohlraums are marked with density non-uniformity whose length scale can go down to micrometers. This scale is of the order of the laser wavelength. The WKB approximation, which is classically used in radiation-hydrodynamic codes to compute the laser trajectory, cannot correctly take into account such small-scale inhomogeneity of the plasma. Going beyond this approximation, we predict a novel mechanism for the laser reflection. Here we show that an electromagnetic plane wave with wave number k resonates with the k B =2 k Fourier component of a multimode perturbation of the background density and generates a reflected wave. It is the first time that this reflection is considered for stationary inhomogeneous ICF plasmas, and the energy absorption is taken into account. This mechanism, which is a form of Bragg reflection, can occur away from the critical surface and generate a drift of the location of the laser absorption. Furthermore, this absorption will be periodically modulated with a k B wave number. The stationary Bragg reflection can explain ongoing discrepancies between experimental and numerical data about laser trajectory and absorption in ICF Hohlraums.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Holographic reflective Bragg gratings of gain and their role in the operation of high-power pulsed lasers

The influence of reflective Bragg gratings that are formed in an active medium due to the spatial periodic modulation of gain on the spectral properties of lasing are investigated by an example of a pulsed Nd : YAG laser. It is shown that, at a certain choice of the formation regime of reflective gratings of gain, the lasing bandwidth can be reduced by a factor of 3 – 5, with a corresponding increase in the pulse energy and significant improvement of spatial beam quality. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oblique diffraction geometry for the observation of several non-coplanar Bragg reflections under identical illumination

A method to determine the strain tensor and local lattice rotation with dark-field X-ray microscopy is presented. Using a set of at least three non-coplanar symmetry-equivalent Bragg reflections, the illuminated volume of the sample can be kept constant for all reflections, facilitating easy registration of the measured lattice variations. This requires an oblique diffraction geometry,i.e.the diffraction plane is neither horizontal nor vertical. We derive a closed analytical expression that allows determination of the strain and lattice rotation from the deviation of experimental observables (e.g.goniometer angles) from their nominal values for an unstrained lattice.

Chemistry↗

Three-dimensional strain imaging of irradiated chromium using multi-reflection Bragg coherent diffraction

Abstract Radiation-induced materials degradation is a key concern in limiting the performance of nuclear materials. The formation of nanoscale void and gas bubble superlattices in metals and alloys under radiation environments can effectively mitigate radiation-induced damage, such as swelling and aid the development of next generation radiation tolerant materials. To effectively manage radiation-induced damage via superlattice formation, it is critical to understand the microstructural changes and strain induced by such superlattices. We utilize multi-reflection Bragg coherent diffraction imaging to quantify the full strain tensor induced by void superlattices in iron irradiated chromium substrate. Our approach provides a quantitative estimation of radiation-induced three-dimensional (3D) strain generated at the microscopic level and predicts the number density of defects with a high degree of sensitivity. Such quantitative evaluation of 3D strain in nuclear materials can have a major impact on predicting materials behavior in radiation environments and can revolutionize design of radiation tolerant materials.

36 MATERIALS SCIENCE↗

Electronic Melting of Silicon in Nanostructures using X-ray Forbidden Bragg Reflections

Abstract We carried out a short beamtime at the Pohang Accelerator Laboratory x-ray Free Electron Laser to perform a pump-probe (PP) laser excitation diffraction experiment on the silicon (222) forbidden Bragg peak. To limit the x-ray penetration, we used a “device layer” silicon film wafer bonded to a silicon substrate. The sample, specially fabricated by MEMC Electronic Materials, had a Si(100) substrate bonded to a 170 nm Si(100) film rotated at 45° for crystallographic isolation. A second sample was reactive-ion-etched down to 52 nm thickness. In the silicon lattice, the covalent bonds are seen exclusively at the 222 reflection. Upon laser excitation, these electrons are expected to be excited to the valence band on femtosecond electronic time scales. The Si(222) reflection is therefore expected to be extinguished on this fast time scale, while the electron–phonon coupled acoustic response is determined by the lattice dynamics. The latter is determined by the speed of sound over the device thickness, which is in the mid-picosecond range.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Simultaneous Multi-Bragg Peak Coherent X-ray Diffraction Imaging

The simultaneous measurement of two Bragg reflections by Bragg coherent X-ray diffraction is demonstrated on a twinned Au crystal, which was prepared by the solid-state dewetting of a 30 nm thin gold film on a sapphire substrate. The crystal was oriented on a goniometer so that two lattice planes fulfill the Bragg condition at the same time. The Au 111 and Au 200 Bragg peaks were measured simultaneously by scanning the energy of the incident X-ray beam and recording the diffraction patterns with two two-dimensional detectors. While the former Bragg reflection is not sensitive to the twin boundary, which is oriented parallel to the crystal–substrate interface, the latter reflection is only sensitive to one part of the crystal. The volume ratio between the two parts of the twinned crystal is about 1:9, which is also confirmed by Laue microdiffraction of the same crystal. The parallel measurement of multiple Bragg reflections is essential for future in situ and operando studies, which are so far limited to either a single Bragg reflection or several in series, to facilitate the precise monitoring of both the strain field and defects during the application of external stimuli.

47 OTHER INSTRUMENTATION↗

K-space algorithmic reconstruction (KAREN): a robust statistical methodology to separate Bragg and diffuse scattering

Diffuse scattering occurring in the Bragg diffraction pattern of a long-range-ordered structure represents local deviation from the governing regular lattice. However, interpreting the real-space structure from the diffraction pattern presents a significant challenge because of the dramatic difference in intensity between the Bragg and diffuse components of the total scattering function. In contrast to the sharp Bragg diffraction, the diffuse signal has generally been considered to be a weak expansive or continuous background signal. In this paper, using 1D and 2D models, it is demonstrated that diffuse scattering in fact consists of a complex array of high-frequency features that must not be averaged into a low-frequency background signal. To evaluate the actual diffuse scattering effectively, an algorithm has been developed that uses robust statistics and traditional signal processing techniques to identify Bragg peaks as signal outliers which can be removed from the overall scattering data and then replaced by statistically valid fill values. This method, described as a 'K-space algorithmic reconstruction' (KAREN), can identify Bragg reflections independent of prior knowledge of a system's unit cell. KAREN does not alter any data other than that in the immediate vicinity of the Bragg reflections, and reconstructs the diffuse component surrounding the Bragg peaks without introducing discontinuities which induce Fourier ripples or artifacts from underfilling `punched' voids. The KAREN algorithm for reconstructing diffuse scattering provides demonstrably better resolution than can be obtained from previously described punch-and-fill methods. The superior structural resolution obtained using the KAREN method is demonstrated by evaluating the complex ordered diffuse scattering observed from the neutron diffraction of a single plastic crystal of CBr 4 using pair distribution function analysis.

36 MATERIALS SCIENCE↗

Combining Laue diffraction with Bragg coherent diffraction imaging at 34-ID-C

Measurement modalities in Bragg coherent diffraction imaging (BCDI) rely on finding a signal from a single nanoscale crystal object which satisfies the Bragg condition among a large number of arbitrarily oriented nanocrystals. However, even when the signal from a single Bragg reflection with ( hkl ) Miller indices is found, the crystallographic axes on the retrieved three-dimensional (3D) image of the crystal remain unknown, and thus localizing in reciprocal space other Bragg reflections becomes time-consuming or requires good knowledge of the orientation of the crystal. Here, the commissioning of a movable double-bounce Si (111) monochromator at the 34-ID-C endstation of the Advanced Photon Source is reported, which aims at delivering multi-reflection BCDI as a standard tool in a single beamline instrument. The new instrument enables, through rapid switching from monochromatic to broadband (pink) beam, the use of Laue diffraction to determine crystal orientation. With a proper orientation matrix determined for the lattice, one can measure coherent diffraction patterns near multiple Bragg peaks, thus providing sufficient information to image the full strain tensor in 3D. The design, concept of operation, the developed procedures for indexing Laue patterns, and automated measuring of Bragg coherent diffraction data from multiple reflections of the same nanocrystal are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Graded Buffer Bragg Reflectors with High Reflectivity and Transparency for Metamorphic Optoelectronics

A graded buffer Bragg reflector (GBBR) is a bifunctional device component that provides the reflection of a distributed Bragg reflector and the adjustable lattice constant of a compositionally graded buffer. Prior work showed that these properties can be combined with low threading dislocation density and high reflectivity. Here, we design and demonstrate complex GBBRs for specific metamorphic solar cell applications. We design buffers that provide (1) high reflectivity over a narrow bandwidth, for quantum well solar cells, (2) reflectivity over a wide bandwidth, for optically thin solar cells, and (3) low sidelobe reflection, for multijunction devices that demand low out-of-band reflection. Apodized and triple GBBRs are demonstrated, and transparency is always considered, requiring designs with carefully engineered material combinations. A GBBR with a reflection of 99% is demonstrated, as well as a triple GBBR that has over 80% reflection for 100?nm of the spectrum around 800?nm. We also analyze potential deviations in a baseline GBBR from that of a perfect DBR using transmission electron microscopy to analyze imperfections in the material and modeling to analyze the impact of imperfect refractive index data for lattice-mismatched AlGaInAs. Minimal crosshatch roughness and unintentional thickness variation occur throughout the buffer, which likely influences reflection slightly. Small deviations between the calculated AlGaInAs and utilized AlGaAs refractive index exist, giving methods for future GBBR improvement. While the GBBR designs are intended for metamorphic solar cells, the broad and high reflection may also be useful for other optoelectronic devices such as light-emitting diodes or lasers.

41 EE - Solar Energy Technologies Office (EE-4S)↗

X-ray optics for the cavity-based X-ray free-electron laser

A cavity-based X-ray free-electron laser (CBXFEL) is a possible future direction in the development of fully coherent X-ray sources. CBXFELs consist of a low-emittance electron source, a magnet system with several undulators and chicanes, and an X-ray cavity. The X-ray cavity stores and circulates X-ray pulses for repeated FEL interactions with electron pulses until the FEL reaches saturation. CBXFEL cavities require low-loss wavefront-preserving optical components: near-100%-reflectivity X-ray diamond Bragg-reflecting crystals, outcoupling devices such as thin diamond membranes or X-ray gratings, and aberration-free focusing elements. In the framework of the collaborative CBXFEL research and development project of Argonne National Laboratory, SLAC National Accelerator Laboratory and SPring-8, we report here the design, manufacturing and characterization of X-ray optical components for the CBXFEL cavity, which include high-reflectivity diamond crystal mirrors, a diamond drumhead crystal with thin membranes, beryllium refractive lenses and channel-cut Si monochromators. All the designed optical components have been fully characterized at the Advanced Photon Source to demonstrate their suitability for the CBXFEL cavity application.

47 OTHER INSTRUMENTATION↗

Massive compression for high data rate macromolecular crystallography (HDRMX): impact on diffraction data and subsequent structural analysis

New higher-count-rate, integrating, large-area X-ray detectors with framing rates as high as 17400 images per second are beginning to be available. These will soon be used for specialized macromolecular crystallography experiments but will require optimal lossy compression algorithms to enable systems to keep up with data throughput. Some information may be lost. Can we minimize this loss with acceptable impact on structural information? To explore this question, we have considered several approaches: summing short sequences of images, binning to create the effect of larger pixels, use of JPEG-2000 lossy wavelet-based compression, and use of Hcompress, which is a Haar-wavelet-based lossy compression borrowed from astronomy. We also explore the effect of the combination of summing, binning, and Hcompress or JPEG-2000. In each of these last two methods one can specify approximately how much one wants the result to be compressed from the starting file size. These provide particularly effective lossy compressions that retain essential information for structure solution from Bragg reflections.

47 OTHER INSTRUMENTATION↗

Integrated polarization-free Bragg filters with subwavelength gratings for photonic sensing

We present polarization-free Bragg filters having subwavelength gratings (SWGs) in the lateral cladding region. This Bragg design expands modal fields toward upper cladding, resulting in enhanced light interaction with sensing analytes. Two device configurations are proposed and examined, one with index-matched coupling between transverse electric (TE) and transverse magnetic (TM) modes and the other one with hybrid-mode (HM) coupling. Both configurations introduce a strong coupling between two orthogonal modes (either TE-TM or HM 1 -HM 2 ) and rotate the polarization of the input wave through Bragg reflection. The arrangements of SWGs help to achieve two configurations with different orthogonal modes, while expanding modal profiles toward the upper cladding region. Our proposed SWG-assisted Bragg gratings with polarization independency eliminate the need for a polarization controller and effectively tailor the modal properties, enhancing the potential of integrated photonic sensing applications.

Optics↗

Concurrent multi-peak Bragg coherent x-ray diffraction imaging of 3D nanocrystal lattice displacement via global optimization

Abstract In this paper we demonstrated a method to reconstruct vector-valued lattice distortion fields within nanoscale crystals by optimization of a forward model of multi-reflection Bragg coherent diffraction imaging (MR-BCDI) data. The method flexibly accounts for geometric factors that arise when making BCDI measurements, is amenable to efficient inversion with modern optimization toolkits, and allows for globally constraining a single image reconstruction to multiple Bragg peak measurements. This is enabled by a forward model that emulates the multiple Bragg peaks of a MR-BCDI experiment from a single estimate of the 3D crystal sample. We present this forward model, we implement it within the stochastic gradient descent optimization framework, and we demonstrate it with simulated and experimental data of nanocrystals with inhomogeneous internal lattice displacement. We find that utilizing a global optimization approach to MR-BCDI affords a reliable path to convergence of data which is otherwise challenging to reconstruct.

36 MATERIALS SCIENCE↗

Toward In Situ Synchrotron Mapping of Crystal Selection Processes during Crystal Growth

In this work, we present an automated and rapid method for non-destructive mapping of crystal grains in a rod-shaped sample. The approach was designed for application to in situ float-zone crystal growth experiments at an x-ray synchrotron source, but could be useful in other applications. The methods have been tested on a TiO 2 boule grown in an optical float zone furnace. The approach applies a statistical filter to polycrystalline diffraction patterns on 2D detectors to rapidly determine the degree of powder-quality 1of the signal. When larger crystals emerge in the growth, their position, size and shape can be tracked using an automated blob-tracking algorithm that follows individual Bragg peaks as a function of position in a grid-scan, even when multiple crystals are contributing spots to diffraction images. This method is found to be robust as the same crystal shape can be independently reconstructed using different sets of Bragg reflections. Image segmentation methods are then used to map out the polycrystalline grains. We also note that other information about crystal quality, such as mosaicity or strain state, may be inferred and mapped from the intensity variation of the Bragg peaks at different locations within the sample.

36 MATERIALS SCIENCE↗

Reuniting crystallography with real space: Ab initio structure elucidation with 4D-STEM

Structure elucidation via single-crystal methods has historically lacked experimental access to real-space information, instead relying exclusively on diffraction-space measurements of Bragg reflections. Here we exploit the dual-space imaging power of 4D scanning transmission electron microscopy to meaningfully integrate real-space information into the crystallographic workflow. We show that virtual apertures assembled by segmentation of high-angle annular dark-field images enable i) pixel-by-pixel separation of coherent Bragg signal from clusters of closely spaced nanocrystals and ii) selective extraction of integrated intensities from thinner subregions of individual specimens, facilitating retroactive tuning of multiple scattering artifacts. This strategy empowers us to simply pick and choose whichever nanoscale regions of interest generate the highest-quality diffraction patterns, allowing us to solve several independent structures of the metal-organic framework UiO-66 from specimens whose agglomerated morphology proved intractable for conventional microcrystal electron diffraction. Our method is compatible with both rotational and serial approaches to data processing, ultimately divulging the first scanning nanobeam electron diffraction structures determined by direct methods at subangstrom resolution.

Saha, Ambarneil↗

Imaging extended single crystal lattice distortion fields with multi-peak Bragg ptychography

Recent advances in phase-retrieval-based x-ray imaging methods have demonstrated the ability to reconstruct 3D distortion vector fields within a nanocrystal by using coherent diffraction information from multiple crystal Bragg reflections. However, these works do not provide a solution to the challenges encountered in imaging lattice distortions in crystals with significant defect content that result in phase wrapping. Moreover, these methods only apply to isolated crystals smaller than the x-ray illumination, and therefore cannot be used for imaging of distortions in extended crystals. We introduce multi-peak Bragg ptychography which addresses both challenges via an optimization framework that combines stochastic gradient descent and phase unwrapping methods for robust image reconstruction of lattice distortions and defects in extended crystals. Our work uses modern automatic differentiation toolsets so that the method is easy to extend to other settings and easy to implement in high-performance computers. This work is particularly timely given the broad interest in using the increased coherent flux in fourth-generation synchrotrons for innovative material research.

36 MATERIALS SCIENCE↗

Experimental demonstration of coupled multi-peak Bragg coherent diffraction imaging with genetic algorithms

Bragg coherent diffraction imaging has the potential to provide significant insight into the structure-properties relationship for crystalline materials by imaging, with nanoscale resolution, three-dimensional strain fields within individual grains and nanoparticles. The capability of present-day synchrotrons to locate and measure a multiplicity of Bragg reflections from a single grain makes it possible to recover the full strain tensor with nanometer resolution. Recent methods for coupling reconstructions from several peaks to determine the strain tensor have been developed and applied to synthetic data, but have not been applied to experimental data. Here, using a coupled genetic reconstruction algorithm, we reconstruct an experimental data set and demonstrate improvements in the ability to resolve vector-valued displacement fields internal to the particle as compared to what is achieved with a noncoupled approach. The coupled approach developed in this work was also validated on simulated data sets. In both simulated and experimental data, reconstructions from our coupled Bragg peak algorithm show improvements over the noncoupled independent reconstruction method of 5% in terms of accuracy and 53% in terms of consistency.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Near total reflection x-ray photoelectron spectroscopy: quantifying chemistry at solid/liquid and solid/solid interfaces

Near total reflection regime has been widely used in x-ray science, specifically in grazing incidence small angle x-ray scattering and in hard x-ray photoelectron spectroscopy (XPS). In this work, we introduce some practical aspects of using near total reflection (NTR) in ambient pressure XPS and apply this technique to study chemical concentration gradients in a substrate/photoresist system. Experimental data are accompanied by x-ray optical and photoemission simulations to quantitatively probe the photoresist and the interface with the depth accuracy of ~1 nm. Together, our calculations and experiments confirm that NTR XPS is a suitable method to extract information from buried interfaces with highest depth-resolution, which can help address open research questions regarding our understanding of concentration profiles, electrical gradients, and charge transfer phenomena at such interfaces. Furthermore, the presented methodology is especially attractive for solid/liquid interface studies, since it provides all the strengths of a Bragg-reflection standing-wave spectroscopy without the need of an artificial multilayer mirror serving as a standing wave generator, thus dramatically simplifying the sample synthesis.

solid/solid interface↗