Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BOLTED JOINTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A reduced Iwan model that includes pinning for bolted joint mechanics

Bolted joints are prevalent in most assembled structures; however, predictive models for their behavior do not exist. Calibrated models, such as the Iwan model, are able to predict the response of a jointed structure over a range of excitations once calibrated at a nominal load. The Iwan model, though, is not widely adopted due to the high computational expense of implementation. To address this, an analytical solution of the Iwan model is derived under the hypothesis that for an arbitrary load reversal, there is a new distribution of dry friction elements, which are now stuck, that approximately resemble a scaled version of the original distribution of dry friction elements. The dry friction elements internal to the Iwan model do not have a uniform set of parameters and are described by a distribution of parameters, i.e., which internal dry friction elements are stuck or slipping at a given load, that ultimately governs the behavior of the joint as it transitions from microslip to macroslip. This hypothesis allows the model to require no information from previous loading cycles. Additionally, the model is extended to include the pinning behavior inherent in a bolted joint. Modifications of the resulting framework are discussed to highlight how the constitutive model for friction can be changed (in the case of an Iwan–Stribeck formulation) or how the distribution of dry friction elements can be changed (as is the case for the Iwan plasticity model). Finally, the reduced Iwan plus pinning model is then applied to the Brake–Reuß beam in order to discuss methods to deduce model parameters from experimental data.

42 ENGINEERING↗

Mitigation of Galvanic Corrosion in Bolted Joint of AZ31B and Carbon Fiber-Reinforced Composite Using Polymer Insulation

The use of polymer insulation to mitigate galvanic corrosion was examined for bolted joints of AZ31B Mg alloy and carbon fiber-reinforced composite. To assess the corrosion behaviors of bolted joints with and without polymer insulation, solution immersion and salt spray exposure (ASTM B117) tests were conducted, and the corrosion depths and volumes were determined for the joint specimens after the tests. The polymer-insulated bolted joints exhibited much lower corrosion depths and volumes, highlighting the effective mitigation of galvanic corrosion. The reductions of joint strength in the post-corrosion joint specimens were relatively small (up to ~10%) in the polymer-insulated group but greater (up to 90%) in the group with no insulation. Cross-sectional characterization of post-corrosion joints with polymer insulation revealed local pits developed on AZ31B under galvanic influence, indicating that limited galvanic attack (that did not decrease the joining integrity significantly) could still occur during a long salt spray exposure (~1264 h) owing to the permeation of an aqueous corrosive medium.

36 MATERIALS SCIENCE↗

Structural Health Monitoring: Using an Autoencoder to Identify Damage in a Bolted Joint [Capstone Project]

Los Alamos National Laboratory (LANL) is an important fixture in the United States Department of Energy’s (DOE) National Nuclear Security Agency (NNSA) complex. LANL is one of the largest national laboratories in the country, and the laboratory’s primary mission is to support the nation’s nuclear stockpile. The lab functions as a design agencies for the NNSA and performs extensive testing on weapons as part of that mission. The shock and vibration test team at LANL utilizes electrodynamic shaker systems for important qualification testing in support of the laboratory’s mission. Modern engineering relies heavily on bolted joints to connect two objects. During these shaker tests, engineers depend on bolted joints to secure the test article to a fixture and the fixture to the table. The test article may be hazardous and contain high explosives which could create a safety issue if a bolted joint failed. A loss of preload in a bolt will affect the way energy is input to the system and may introduce nonlinearities as the joint opens and closes. The loss of preload can create challenges controlling the test and make acquired signals useless. Being able to monitor preload within bolted joints during testing can improve the quality of the data and keep workers safe.

42 ENGINEERING↗

Observations of modal coupling due to bolted joints in an experimental benchmark structure

The goal of this paper is to present a set of measurements from a benchmark structure containing two bolted joints to support future efforts to predict the damping due to the joints and to model nonlinear coupling between the first two elastic modes. Bolted joints introduce nonlinearities in structures, typically causing a softening in the natural frequency and an increase in damping because of frictional slip between the contact interfaces within the joint. These nonlinearities pose significant challenges when characterizing the response of the structure under a large range of load amplitudes, especially when the modal responses become coupled, causing the effective damping and natural frequency to not only depend on the excitation amplitude of the targeted mode, but also the relative amplitudes of other modes. In this work, two nominally identical benchmark structures, known in some prior works as the S4 beam, are tested to characterize their nonlinear properties for the first two elastic modes. Detailed surface measurements are presented and validated through finite element analysis and reveal distinct contact interactions between the two sets of beams. The free-free test structures are excited with an impact hammer and the transient response is analyzed to extract the damping and frequency backbone curves. A range of impact amplitudes and drive points are used to isolate a single mode or to excite both modes simultaneously. Differences in the nonlinear response correlate with the relative strength of the modes that are excited, allowing one to characterize mode coupling. Each of the beams shows different nonlinear properties for each mode, which is attributed to the different contact pressure distributions between the parts, although the mode coupling relationship is found to be consistent between the two. Lastly, the test data key finding are presented in this paper and the supporting data is available on a public repository for interested researchers.

42 ENGINEERING↗

Majorana Demonstrator Bolted Joint Mechanical and Thermal Analysis

The MAJORANA DEMONSTRATOR is designed to probe for neutrinoless double-beta decay, an extremely rare process with a half-life in the order of 10 26 years. The experiment uses an ultra-low background, high-purity germanium detector array. The germanium crystals are both the source and the detector in this experiment. Operating these crystals as ionizing radiation detectors requires having them under cryogenic conditions (below 90 K). A liquid nitrogen thermosyphon is used to extract the heat from the detectors. The detector channels are arranged in strings and thermally coupled to the thermosyphon through a cold plate. The cold plate is joined to the thermosyphon by a bolted joint. This circular plate is housed inside the cryostat can. This document provides a detailed study of the bolted joint that connects the cold plate and the thermosyphon. An analysis of the mechanical and thermal properties of this bolted joint is presented. The force applied to the joint is derived from the torque applied to each one of the six bolts that form the joint. The thermal conductivity of the joint is measured as a function of applied force. The required heat conductivity for a successful experiment is the combination of the thermal conductivity of the detector string and this joint. The thermal behavior of the joint is experimentally implemented and analyzed in this study.

Aguayo Navarrete, Estanislao↗

Monitoring of bolted joints using piezoelectric active-sensing for aerospace applications

This paper is a report of an initial investigation into tracking and monitoring the integrity of bolted joints using piezoelectric active-sensors. The target application of this study is a fitting lug assembly of unmanned aerial vehicles (UAVs), where a composite wing is mounted to a UAV fuselage. The SHM methods deployed in this study are impedance-based SHM techniques, time-series analysis, and high-frequency response functions measured by piezoelectric active-sensors. Different types of simulated damage are introduced into the structure, and the capability of each technique is examined and compared. Additional considerations encountered in this initial investigation are made to guide further thorough research required for the successful field deployment of this technology.

42 ENGINEERING↗

Fundamentals of Solar PV Bolted Joint Loosening and Prevention

The photovoltaic (PV) industry has long reported anecdotal accounts of systems exhibiting intermittent or chronic fastener loosening, including joints that fail to maintain preload despite multiple re-tightening attempts. These occurrences are frequently, and often incorrectly, attributed to installer errors, vibration, or loading beyond design expectations (e.g., extreme weather events). Loose fasteners have serious implications and can significantly impact solar PV systems’ performance, reliability, and safety. However, effective bolted joint design and proper assembly practices can mitigate or eliminate loosening. Until the US Department of Energy’s Solar Energy Technologies Office (SETO) funded research on fasteners and solar PV structures, there was a notable gap in understanding the causes of loosening in solar PV systems.

14 SOLAR ENERGY↗